首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Results of TDPAC investigations with111In(111Cd) in CdS, CdSe, and CdTe are presented. There is an easy annealing of radiation damage after recoil implantation. The quadrupole coupling constants of AIIBVI compounds with wurtzite structure are correlated with the axis ratioc/a. An electric field gradient produced by monopoles and anion dipoles indicates the same structure dependence.  相似文献   

2.
Accurate knowledge of the neutron energy spectra is useful in basic research and applications. The overall procedure of measuring and unfolding the fast neutron energy spectra with BC501A liquid scintillation detector is described. The recoil proton spectrum of 241Am-Be neutrons was obtained experimentally. With the NRESP7 code, the response matrix of detector was simulated. Combining the recoil proton spectrum and response matrix, the unfolding of neutron spectra was performed by GRAVEL iterative algorithm. A MatLab program based on the GRAVEL method was developed. The continuous neutron spectrum of 241Am-Be source and monoenergetic neutron spectrum of D-T source have been unfolded successfully and are in good agreement with their standard reference spectra. The unfolded 241Am-Be spectrum are more accurate than the spectra unfolded by artificial neural networks in recent years.  相似文献   

3.
言杰  李澄  刘荣  蒋励  鹿心鑫  王玫 《物理学报》2011,60(3):32901-032901
本文利用252Cf快裂变室和多参数数据采集系统,逐事例的同时记录了自发裂变中子和瞬发伽马的飞行时间(TOF),脉冲形状甄别(PSD)和反冲能量(RE,裂变中子是通过测量反冲质子;瞬发伽马是通过测量康普顿反冲电子)三维信息.详细介绍了通过离线数据分析完全扣除三维信息中的伽马事例贡献,以获得Φ50.8 mm×50.8 mm的BC501A液闪探测器的相对探测效率和响应函数的方法.在不通过探测器响应函数进行数据转换的条件下,利用中子的能量直接确定了中子的有效测量阈值.得到的中子 关键词: 252Cf快裂变室')" href="#">252Cf快裂变室 BC501A液闪探测器 相对探测效率 响应函数  相似文献   

4.
This work focusses on the estimation of induced photoneutrons energy, fluence, and strength using nuclear track detector (NTD) (CR-39). Photoneutron energy was estimated for three different linear accelerators, LINACs as an example for the commonly used accelerators. For high-energy linear accelerators, neutrons are produced as a consequence of photonuclear reactions in the target nuclei, accelerator head, field-flattening filters and beam collimators, and other irradiated objects. NTD (CR-39) is used to evaluate energy and fluence of the fast neutron. Track length is used to estimate fast photoneutrons energy for linear accelerators (Elekta 10 MV, Elekta 15 MV, and Varian 15 MV). Results show that the estimated neutron energies for the three chosen examples of LINACs reveals neutron energies in the range of 1–2 MeV for 10 and 15 MV X-ray beams. The fluence of neutrons at the isocenter (Φtotal) is found to be (4×106 n cm2 Gy?1) for Elekta machine 10 MV. The neutron source strengths Q are calculated. It was found to be 0.2×1012 n Gy?1 X-ray at the isocenter. This work represents simple, low cost, and accurate methods of measuring fast neutrons dose and energies.  相似文献   

5.
The epithermal neutron beam of the Tsing Hua Open-pool Reactor (THOR) was constructed for the study of boron neutron capture therapy (BNCT). The THOR epithermal neutron beam was mainly composed of thermal neutrons, fast neutrons, and photons. For fast neutrons and photons, the absorbed dose and the relative biological effectiveness (RBE) were used to characterize radiation dose and radiation quality. The short-ranged alpha particles and lithium ions produced from 10B(n,α)7Li reactions in the BNCT required cellular- and micro-dosimetry characterizations. Due to the non-uniform microdistribution of boron in cells, these characterizations should depend on the source–target geometry. In this case, the geometry-dependent specific cellular dose and lineal energy could be used to describe radiation dose and radiation quality. In the present work, cellular- and micro-dosimetry were studied for the THOR epithermal neutron beam. The specific cellular dose and lineal energy were calculated for thermal neutron-induced α-particles and 7Li-ions with different source–target geometry and various cell sizes. Applying the linear energy dependent-biological weighting function, the geometry-dependent RBE of thermal neutron-induced heavy particles was determined. Finally, the effective RBE of the THOR epithermal neutron beam was estimated for tumors and normal tissues of specified 10B concentrations. This effective RBE should be multiplied by the total absorbed dose to determine the corresponding biological dose required in the treatment planning.  相似文献   

6.
The neutrons from a Po-α-Be source were detected via the recoil protons in a stilbene scintillator. The pulse height spectrum of the scintillations produced in the stilbene crystal by the recoil protons is analysed to yield the incident neutron energy distribution. Theγ-ray background was eliminated through pulse shape discrimination. Separately the spectrum of neutrons coincident withγ-rays, i.e. of neutrons from the Be9(α,n)C12* reaction, has been determined. The resulting spectra are compared to previous measurements. The structure of the spectra is not compatible with an isotropic angular distribution of the neutrons relative to theα-direction. Furthermore it could be shown that the fraction of reactions leading to the 7,65 MeV state of C12 is only about 10?3.  相似文献   

7.
A neutron personal dosemeter using CR-39 as a detector and hydrogenated materials as proton converters for fast neutron detection plus an air layer for thermal neutron detection is being developed in our laboratory. To increase the CR-39 response to thermal neutrons, the air converter was substituted with Nylon in some dosemeters. Several dosemeters with these two configurations were mounted on a water-filled phantom and exposed under different incidence angles (0, 30 and 60) to: (i) Three ISO neutron sources (241Am–Be, bare 252Cf and moderated 252Cf with Cd shielding), and (ii) two realistic neutron sources (SIGMA and moderated 252Cf) at the IRSN (Cadarache) facilities. The irradiated detectors were electrochemically etched and evaluated in order to determine their dose equivalent response in terms of Hp(10,α). The results obtained are compared to those obtained from Monte Carlo simulations using the MCNPX code.  相似文献   

8.
The energy spectrum of neutrons emitted after ω-capture in 40Ca has been measured up to the kinematical endpoint of 92 MeV using two recoil telescopes. The neutron energy was deduced from the energy and angle of recoiling protons which originate from interactions of neutrons in a liquid scintillator. The neutron spectrum above 30 MeV is reproduced fairly well by a simple calculation based upon a reaction mechanism in which the muon is adsorbed, like in pion capture, by a pair of nucleons.  相似文献   

9.
A series of experiments has been conducted at the Frank Laboratory of Neutron Physics (FLNP) of the Joint Institute for Nuclear Research (JINR) in order to study the possibility of determining the moisture content of coke using a standard neutron source. The proposed method is based on a measurement of the spectrum of prompt γ rays emitted when samples are irradiated by fast and/or thermal neutrons. The moisture content is determined from the area of the peaks of characteristic γ rays produced in the radiative capture of thermal neutrons by the proton (Eγ = 2.223 MeV) and inelastic scattering of fast neutrons by 16O (Eγ = 6.109 MeV). The 239Pu–Be neutron source (〈E n 〉 ~ 4.5 MeV) with an intensity of ~5 × 106 n/s was used to irradiate the samples under study. A scintillation detector based on a BGO crystal was used to register the characteristic γ radiation from the inelastic fast neutron scattering and slow (thermal) neutron capture. This paper presents the results of humidity measurement in the range of 2–50% [1, 2].  相似文献   

10.
Selective quenching of luminescence of quantum dots (QDs) by Cu2+ ions vis-à-vis other physiologically relevant cations has been reexamined. In view of the contradiction regarding the mechanism, we have attempted to show why Cu2+ ions quench QD-luminescence by taking CdS and CdTe QDs with varying surface groups. A detailed study of the solvent effect and also size dependence on the observed luminescence has been carried out. For a 13% decrease in particle diameter (4.3 nm →3.7 nm), the quenching constant increased by a factor of 20. It is established that instead of surface ligands of QDs, conduction band potential of the core facilitates the photo-induced reduction of Cu (II) to Cu (I) thereby quenching the photoluminescence. Taking the advantage of biocompatibility of dendrimer and its high affinity towards Cu2+ ions, we have followed interaction of Cu2+-PAMAM and also dendrimer with the CdTe QDs. Nanomolar concentration of PAMAM dendrimer was found to quench the luminescence of CdTe QDs. In contrast, Cu2+-PAMAM enhanced the fluorescence of CdTe QDs and the effect has been attributed to the binding of Cu2+-PAMAM complex to the CdTe particle surface. The linear portion of the enhancement plot due to Cu2+-PAMAM can be used for determination of Cu2+ ions with detection limit of 70 nM.  相似文献   

11.
The working principle of the Boron Neutron Capture Therapy (BNCT) is the selective delivery of a greater amount of boron to the tumor cells than to the healthy ones, followed by the neutron irradiation that will induce the emission of α-particles and recoil 7Li nuclei through the 10B(n,α)7Li reaction. The objective of this work is to present a setup composed of a boron thin film coupled with CR-39. Alpha and 7Li particle coming from the boron films are used to quantify neutron boron reaction and are detected by CR-39. The nuclei compounding of this detector, H, C and O, will undergo fast neutrons reactions, which will be detected in the CR-39 itself. In this way, the 10B(n,α)7Li reaction and the contribution of fast neutrons to the flux can be determined at the same time. These measurements are essential for treatment planning as well as for studies of the biodistribution of 10B-carrier drugs and tissue microdosimetry. The boron films were deposited on stainless steel substrates through the sputtering technique and irradiated with thermal neutrons at the reactor IEA-R1 located at IPEN, São Paulo/SP, Brazil. Here we show the first results on the characterization of these thin films and calibration of the proposed setup.  相似文献   

12.
A simple additive formula is given which, for neutron energies in the range 10-4 < E<10 eV, permits calculation of the nuclear capture, thermal diffuse and Bragg scattering cross-sections of a crystalline material as a function of its crystal constants and temperature. Computer codes PUO and SUO were developed to calculate the total attenuation of reactor neutrons through poly- and mono-crystalline samples, respectively. The codes were applied to calculate the total cross-section of polycrystalline uranium and thorium dioxides in the energy range from 4 meV to 1 eV. The obtained agreement between the calculated values and available experimental values justifies the applicability of the used formula and the computer codes. A feasibility study on using depleted polycrystalline uranium dioxide as a cold neutron filter and the single crystal as a thermal neutron filter is given. The optimum crystal parameters and thickness for efficiently transmitting the thermal reactor neutrons while strongly attenuating both fast neutrons and -rays accompanying the thermal ones is also given.  相似文献   

13.
厚闪烁体内次级中子对快中子图像质量的影响研究   总被引:1,自引:0,他引:1       下载免费PDF全文
利用编制的快中子照相数值模拟程序(FNRSC)模拟计算了入射中子能量为14 MeV时,厚度5—300 mm闪烁体内次级中子对快中子图像质量的影响,结果表明闪烁体厚度d<50mm时,次级中子对图像的影响强烈依赖于闪烁体厚度,而当d>50 mm时,次级中子对图像的影响趋于饱和.将文献中利用蒙特卡罗中子-光子输运程序(MCNP)计算的次级中子对图像影响和文中计算结果进行了对比,给出了二者存在差异的主要原因:次级中子分布对入射中子空间分布的强烈依赖性;能量沉积和荧光输出这两种计算方法对 关键词: 14 MeV中子 快中子照相 次级中子 Monte Carlo模拟  相似文献   

14.
ST-401薄塑料闪烁体中子能量响应测量技术研究   总被引:2,自引:0,他引:2       下载免费PDF全文
利用中国原子能科学研究院核工业放射性计量测试中心的5SDH-2串列加速器进行了ST-401薄塑料闪烁体的能量响应实验.选用T(p,n)3He反应和D(d,n)3He反应作为中子源,子源,中子束流采用复合屏蔽体进行准直,源强采用正比计数管和半导体望远镜进行监测,实验测量了厚度从0.16mm到2.00mm的八种规格薄闪烁体的能量响应曲线,对实验的结果的不确定度进行了分析.结果表明探测器的灵敏度随着晶体厚度的增加而增加,对于一定厚度的薄闪烁体,随着中子能量的增加,探测器的能量响应曲线坡度不大. 关键词: 塑料闪烁体 能量响应 正比计数器 半导体反冲质子望远镜  相似文献   

15.
We have developed a thermal neutron calibration method using a reactor produced neutron beam in JRR-3M of the Japan Atomic Energy Agency. Neutron-induced prompt gamma ray analysis has usually been performed in this beam line. Neutron energy distributions with negligible contributions from epithermal neutrons were measured by a time-of-flight method with a chopper made of 6LiF powder. The thermal neutron flux was determined by a gold foil activation method. We found that the thermal neutron beam in JRR-3M was well suited for calibration, neutron detector development or neutron dosimetry.  相似文献   

16.
A set of five 241Am–Be neutron sources are utilized in research and teaching at King Fahd University of Petroleum and Minerals (KFUPM). Three of these sources have an activity of 16 Ci each and the other two are of 5 Ci each. A well-shielded storage area was designed for these sources. The aim of the study is to check the effectiveness of shielding of the KFUPM neutron source storage area. Poly allyl diglycol carbonate (PADC) Nuclear track detectors (NTDs) based fast and thermal neutron area passive dosimeters have been utilized side by side for 33 days to assess accumulated low ambient dose equivalents of fast and thermal neutrons at 30 different locations around the source storage area and adjacent rooms. Fast neutron measurements have been carried out using bare NTDs, which register fast neutrons through recoils of protons, in the detector material. NTDs were mounted with lithium tetra borate (Li2B4O7) converters on their surfaces for thermal neutron detection via and nuclear reactions. The calibration factors of NTD both for fast and thermal neutron area passive dosimeters were determined using thermoluminescent dosimeters (TLD) with and without a polyethylene moderator. The calibration factors for fast and thermal neutron area passive dosimeters were found to be 1.33 proton tracks and 31.5 alpha tracks , respectively. The results show variations of accumulated dose with the locations around the storage area. The fast neutron dose equivalents rates varied from as low as up to whereas those for thermal neutron ranged from as low as up to . The study indicates that the area passive neutron dosimeter was able to detect dose rates as low as 7 and from accumulated dose for thermal and fast neutrons, respectively, which were not possible to detect with the available active neutron dosimeters.  相似文献   

17.
The emission spectra of prompt fission neutrons from mass and kinetic energy selected fission fragments have been measured in235U(n th,f). Neutron energies were determined from the measurement of the neutron time of flight using a NE213 scintillation detector. The fragment energies were measured by a pair of surface barrier detectors in one set of measurements and by a back-to-back gridded ionization chamber in the second set of measurements. The data were analysed event by event to deduce neutron energy in the rest frame of the emitting fragment for the determination of neutron emission spectra and multiplicities as a function of the fragment mass and total kinetic energy. The results are compared with statistical model calculations using shell and excitation energy dependent level density formulations to deduce the level density parameters of the neutron rich fragment nuclei over a large range of fragment masses.  相似文献   

18.
According to stationary X-ray-excited luminescence spectra and thermally stimulated luminescence spectra of CaF2:Eu nanophosphors, it was found that Eu3+?→?Eu2+ conversion can occur during thermal annealing of fine-grained (d?=?25?nm) nanoparticles in the 200–800°C range, which is accompanied by an increase in their size within 40–189?nm. An important role of the exciton mechanism of Eu2+ luminescence excitation was revealed according to the temperature dependence of X-ray-excited luminescence spectra of CaF2:Eu nanoparticles of 114?nm size. The maximum of the X-ray-excited luminescence light output of CaF2:Eu nanophosphors in the Eu2+ ions’ emission band was traced out at 400–500°C annealing temperature and at the size of nanoparticles of 114–180?nm. The subsequent growth of the annealing temperatures, particularly in the 800–1000°C range, causes the reduction of X-ray-excited luminescence light output because of the increment of lattice defects’ concentration due to a sharp increase in the size of nanoparticles and their agglomeration.  相似文献   

19.
The structural phase transformations of Cd chalcogenide compounds (CdS, CdSe, and CdTe) under high pressure are studied using the local approximation to the density functional theory, and the one-electron equations are solved by means of the full potential linear muffin-tin-orbital method. CdS, CdSe, and CdTe are found to have nearly similar behaviour of the structural properties under high pressure. In the CdS compound, thePmmn phase is predicted to be thermodynamically stable after the rock-salt structure, and theCmcm structure is found to be thermodynamically stable before the rock-salt structure in both CdSe and CdTe. The resulting structural properties of the zinc-blende, wurtzite, cinnabar, rock-salt,Pmmn, CsCl,Cmcm, and β-Sn phases for these considered compounds are found to be in agreement with the existing experimental data.  相似文献   

20.
It is known that CdTe solar cells are often degraded under solar illumination. But the degradation mechanism is not fully proved because it does not appear consistently. The junction degradation in CdS/CdTe solar cells was investigated using a CdTe layer with Cd deficient composition, where Cd vacancy concentration is high. It was found that the Cu atoms easily filled the Cd vacancies in CdTe and transport to junction area from Cu back contact. PL measurement and spectral quantum efficiency measurement showed that the incorporation of Cu atoms in CdS forms a defect energy level at 1.55 eV below the conduction band in CdS. As a result, the junction built-in potential is decreased and light penetration into CdTe absorber is shielded. For reliable and stable CdTe cells, the formation of Cd vacancy in CdTe should be avoided by careful control of CdTe.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号