首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ammonium perchlorate, a key ingredient in solid rocket propellants, has been found in ground and surface waters in a number of U.S. states, and perchlorate contamination of public drinking water wells is now a serious problem in California. Perchlorate poses a health risk and preliminary data from the U.S. EPA reports that exposure to less than 4-18 microg/l provides adequate human health protection. An improved ion chromatographic method was developed for the determination of low microg/l levels of perchlorate in ground and drinking waters based on a Dionex IonPac AS16 column, an hydroxide eluent generated using an EG40 automated eluent generator, large loop (1000 microl) injection, and suppressed conductivity detection. The method is free of interferences from common inorganic anions, linear over the range of 2-100 microg/l perchlorate, and quantitative recoveries are obtained for low microg/l levels of perchlorate in spiked ground and drinking water samples. The MDL of 150 ng/l permits quantification of perchlorate below the levels that ensure adequate health protection.  相似文献   

2.
On the basis of the chromogenic reaction of chromium(VI) with 1,5-diphenylcarbohydrazide (DPC) on the surface of Polysorb C-18 beads and the sequential injection renewable surface technique (SI-RST), a highly sensitive reflect spectrophotometric method for the determination of chromium(III) and chromium(VI) was proposed. Considerations of system and flow cell design, and factors that influence the determination performance were discussed. With 300 microl of sample loaded and 0.6 mg of beads trapped, the linear response range was 0.02 - 0.5 mg l(-1) Cr(VI) with a detection limit (3 sigma) of 2.4 microg l(-1) Cr(VI). The method achieves a precision of 1.3% RSD (n = 11) and a throughput of 53 samples per hour. The determination of Cr(III) was based on the same reaction for the determination of Cr(VI) after being oxidized by (NH4)2S2O8. The precision of the oxidation method was evaluated using a 0.2 mg l(-1) Cr(III) standard, yielding an RSD of 2.5% (n = 11). The average recovery of Cr(III) oxidized was tested to be 99.1%. The proposed method was used in the simultaneous determination of Cr(VI) and Cr(III) in water samples, and the error was less than 3%.  相似文献   

3.
An ion chromatographic method for the rapid and direct determination of iodide in seawater is reported. Poly(ethylene glycol) (PEG) groups were chemically bonded onto silica gel or C30-bonded silica gel via diol groups. PEG-bonded C30 binary phases allowed determination of iodide in seawater samples without any interference. Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention of analyte anions. The retention time of anions increased with increasing eluent concentration. The detection limit for iodide obtained by injecting 0.2 microl of sample was 13 microg l(-1) (S/N=3) while the limit of quantitation was 43 microg l(-1) (S/N=10). The present method was successfully applied to the rapid and direct determination of iodide in seawater with long-term durability.  相似文献   

4.
The construction and performance characteristics of a novel chromate ion-selective membrane sensor are described and used for determining chromium(III) and chromium(VI) ions. The sensor is based on the use of a rhodamine-B chromate ion-associate complex as an electroactive material in a poly(vinyl chloride) membrane plasticized with o-nitrophenyloctyl ether as a solvent mediator. In a phosphate buffer solution of pH 6 - 7, the sensor displays a stable, reproducible and linear potential response over the concentration range of 1 x 10(-1) - 5 x 10(-6) mol l(-1) with an anionic Nernstian slope of 30.8 +/- 0.5 mV decade(-1) and a detection limit of 1 x 10(-6) mol l(-1) Cr(VI). High selectivity for Cr(VI) is offered over many common anions (e.g., I-, Br-, Cl-, IO4-, CN-, acetate, oxalate, citrate, sulfate, phosphate, thiosulfate, selenite, nitrate) and cations (e.g., Ag+, Ca2+, Sr2+, Co2+, Ni2+, Cu2+, Mn2+, Fe2+, Zn2+, Cd2+, Al3+, Cr3+). The sensor is used for determining Cr(VI) and/or Cr(III) ions in separate or mixed solutions after the oxidation of Cr(III) into Cr(VI) with H2O2. As low as 0.2 microg ml(-1) of chromium is determined with a precision of +/-1.2%. The chromium contents of some wastewater samples were accurately assessed, and the results agreed fairly well with data obtained by atomic absorption spectrometry.  相似文献   

5.
Hagendorfer H  Goessler W 《Talanta》2008,76(3):656-661
Due to its extensive use in industrial processes, large quantities of chromium compounds are discharged into the environment. Common approaches for the speciation of Cr employ the determination of Cr(VI) and total Cr. The focus of the present work was a separation of Cr(III) and Cr(VI) species, with a minimum of sample preparation, by keeping an eye on the more relevant and toxic Cr(VI). For the successful simultaneous separation of both chromium species we implemented a RSpak NN-814 4DP (PEEK, 4 mm x 150 mm) multi-mode column using an eluent containing 90 mM ammonium sulfate and 10 mM ammonium nitrate, adjusted to pH 3.5. At a flow of 0.3 mL min(-1) the separation of both Cr species was possible within 8 min. Further the octopole reaction system of the inductively coupled plasma mass spectrometer was systematically studied and optimised to reduce the influence of polyatomic interferences. The major advantage of the developed method compared to published methods is that a derivatisation of the Cr(III) species--an invasion in the speciation--is not required. With the used multi-mode column both chromium species are retained. Furthermore the pH of the mobile phase (pH 3.5) prevents reduction of Cr(VI) as well as precipitation of Cr(III) during the analysis. A limit of determination of approximately 0.5 microg L(-1) for both chromium species with an injection volume of 25 microL was obtained. The optimised method was successfully applied to the determination of Cr(VI) in cement samples as well as chromium speciation analysis in homeopathic drugs.  相似文献   

6.
An ion chromatography method for rapid and direct determination of iodide in seawater and edible salt is reported. Separation was achieved using a laboratory-made C30 packed column (100 mm x 0.32 mm i.d.) modified with poly(ethylene glycol) (PEG). Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention of analyte anions. The retention time of anions increased with increasing eluent concentration when lithium chloride, sodium chloride, potassium chloride, sodium sulfate, magnesium sulfate were used as the eluent, while it decreased with increasing eluent concentration when ammonium sulfate was used as the eluent. The detection limit for iodide obtained by injecting 0.2 microl of sample was 9 microg/l (S/N = 3). The present method was successfully applied to the rapid and direct determination of iodide in seawater and edible salt samples. Partition may be involved in the present separation mode.  相似文献   

7.
Summary Chromium(VI) is one of the major pollutants of waters and unfortunately, at the present time, it cannot be determined with a simple and fast method. The use of the ultraviolet multiwavelength absorptiometry (UVMA) for chromium determination is very convenient for that purpose because of the well known absorption properties of chromium. Two methods are proposed which lead to different sensitivity. The first one needs hydroxide sodium addition for the measurement of the chromate form and has a detection limit of 4 g/l. The second does not use any reagent and determines directly both dichromate and chromate forms, whose sum gives the concentration of chromium(VI). This last procedure is faster but the characteristics are slightly less precise. These proposed methods have been compared with a reference method, for natural waters and treated wastewaters, with good agreement. These procedures can be used for water quality monitoring.  相似文献   

8.
Mehra HC  Frankenberger WT 《Talanta》1989,36(9):889-892
Single-column ion-chromatography (SCIC) was investigated as a routine, rapid, precise and selective analytical method for the determination of chromium(VI) in aqueous extracts of soil and sewage sludge. Chromatographic parameters were optimized for determination of Cr(VI), NO(-)(3) and SO(2-)(4). A low-capacity resin-based column was used for the separation and the anions were determined by conductometric detection. p-Hydroxybenzoic acid (5mM) at pH 8.5 was used as the eluent. The limit of detection, defined as S/N = 3, was 92 mug/l. The resolution between Cr(VI) and SO(2-)(4) was 2.8, the precision ranged from 0.9% for NO(-)(3) to 2.0% for Cr(VI) with a 500-mul injection. The SCIC results for Cr(VI) agreed closely with those obtained by inductively coupled argon-plasma emission and spectrophotometry.  相似文献   

9.
An implementation of the Dionex IonPac AS12A analytical column with an element-specific ICP-MS detection is described for the simultaneous determination of halogen and oxyhalogen anions, sulfate, phosphate, selenite, selenate and arsenate. The chromatographic separation was achieved in less than 4 min with an aqueous 11 mM (NH4)2CO3 (pH 11.2, adjusted with aqueous ammonia) as eluent. Special emphasis was given to optimize the ICP-MS detection conditions for the reliable detection (RSD<5%) of bromate and bromide at a bromine concentration level of 1.0 microg l(-1) with 50 microl sample injection volume. In order to achieve the highest detector response for bromine species an ultrasonic nebulizer equipped with a membrane desolvator had to be employed. The detection limits (S/N=3, sample injection volume 50 microl) obtained with the IC-ICP-MS after the optimization were 0.67 microg l(-1) for BrO3-, 0.47 microg l(-1) for Br-, 69 microg l(-1) for ClO2-, 4 microg l(-1) for Cl-, 47 microg l(-1) for ClO3-, 13 microg l(-1) for SO4(2-), 36 microg l(-1) for PO4(3-), 0.4 microg l(-1) for SeO3(2-), 0.3 microg l(-1) for SeO4(2-), and 0.4 microg l(-1) for AsO4(3-).  相似文献   

10.
A method for the pre-treatment of acid samples prior to ion chromatography is described. In a strong acid medium, Cr(VI) oxidizes diphenylcarbazide, the resulting products forming a stable complex which can be transferred in a methanolic medium by solid-phase extraction using polyethylene as sorbent. This methanolic sample solution can be injected directly into a chromatographic system with a silica-based column. The separation and determination of the chromium complex can be performed by HPLC-using a mobile phase of 15% (v/v) acetonitrile containing 1 mmol/L tetrabutyl ammonium hydroxide (TBAH). The detection limit is estimated to be 2 microg/L chromate and the linear range is at least 0.05-2 mg/L chromate.  相似文献   

11.
The European Union has banned chromium(VI) compounds in electrical and electronic equipment (EEE), such as chromate conversion coating films. Chromium(III) compounds are not banned. Using Raman spectroscopy without any preparation, we distinguished chromium(VI) oxide from chromium(III) oxide and chromium(III) hydroxide in chromate conversion coating films. Raman bands of chromium(VI) oxide were detected in films at around 1000 and 500 cm(-1), while chromium(III) compounds generated no bands in the region between 2000 and 200 cm(-1). The analysis took about 1 min, whereas the usual diphenylcarbazide-colorimetric method for analyzing chromium(VI) compounds takes about 10 h.  相似文献   

12.
Hoshi S  Konuma K  Sugawara K  Uto M  Akatsuka K 《Talanta》1998,47(3):659-663
Preconcentration method with collection of metal complexes on a chitin has been applied to the spectrophotometric determination of chromium(VI) in water. The chromium(VI) is collected as its 1,5-diphenylcarbazide(DPC) complex on a column of chitin in the presence of dodecyl sulfate as counter-ion. The Cr-DPC complex retained on the chitin is eluted with a methanol-1 M acetic acid mixture (7:3, v/v), and the absorbance of the eluent is measured at 541 nm. Beer's law is obeyed over the concentration range of 0.05-0.6 mug of chromium(VI) in 1 ml of the eluent. The apparent molar absorptivity is 3.5x10(4) dm(3) mol(-1) cm(-1). The tolerance limits for Fe(III) is low, i.e. ten times that of chromium(VI), but some metal ions and common inorganic anions do not interfere in concentration range of 100-10 000 times that of chromium(VI). The present method can be applied to the determination of chromium(VI) in natural water samples.  相似文献   

13.
A method for the simultaneous determination of chromium(III) and chromium(VI) by capillary electrophoresis (CE) has been developed. The chromium(III) has been chelated with 1,2-cyclohexanediaminetetraacetic acid (CDTA) in order to impart a negative charge and similar mobility to both the chromium(III) and the chromium(VI) species. The effects of the amount of the reagent, pH and heating time required to complete the complexation have been studied. Factors affecting the CE behaviour such as the polarity of electrodes and the pH of electrophoretic buffer have been investigated. The separated species have been monitored by direct UV measurements at 214 nm. The detection limits achieved are 10 microg/l for Cr(VI) and 5 microg/l for Cr(III) and linear detector response is observed up to 100 mg/l. The procedure has been applied to the determination of both chromium species in industrial electroplating samples and its accuracy was checked by comparing the results (as total chromium) with those of atomic absorption spectrometry. No interference occurred from transition metal impurities under optimized separation conditions. The method is also shown to be feasible for determining Cr(III) as well as other metal ions capable to form complexes with CDTA (like iron(III), copper(II), zinc(II) and manganese(II)) in pharmaceutical preparations of essential trace elements.  相似文献   

14.
Simultaneous analysis of ascorbic acid and chromium (VI) in soluble fractions and bronchoalveolar lavage fluids of rat lungs treated with sodium chromate in vitro and in vivo was performed by anion-exchange high-performance liquid chromatography coupled to a photodiode-array detector. Absorbances at 265 and 370 nm were used for the determination of ascorbic acid and chromium (VI), respectively. The calibration graphs of standard solutions were linear in the test ranges of ascorbic acid an chromium (VI) (below 10 and 8 ppm, respectively). The detection limits of ascorbic acid and chromium (VI) were 1 and 0.5 ng, respectively. The recovery of ascorbic acid from lung tissues homogenized at pH 7.4 was 99%, and that of chromium (VI) was 96%, when tissues were homogenized under alkaline conditions (pH 11.4). Using this method, ascorbic acid levels in the soluble fractions and lavage fluids of normal rat lungs were determined. In the lung of a rat intratracheally injected with a saline solution of sodium chromate, ascorbic acid decreased to 80% of the normal level, and ca. 90% of the chromium (VI) was reduced within 4 min after injection, indicating that the ascorbic acid-related reduction of chromium (VI) is very rapid. The present method will be useful for studies of the reduction of chromium (VI) by ascorbic acid in biological systems.  相似文献   

15.
Determination of trace concentrations of hexavalent chromium   总被引:1,自引:0,他引:1  
Gardner M  Comber S 《The Analyst》2002,127(1):153-156
A simple and sensitive solvent extraction-atomic spectrometric technique has been developed for the determination of hexavalent chromium in fresh and saline waters. The technique is based on the reaction of chromium with diphenylcarbazide. The method has been tested on a variety of water samples over an analytical range of 0-2 microg l(-1). A limit of detection of 0.024 microg l(-1) was achieved. Spiking recoveries in the range 87-115% were achieved in river water, drinking water and marine waters.  相似文献   

16.
A procedure to accurately quantitate chromium(V) in environmental and medicinal chemistry samples was developed using electron paramagnetic resonance spectroscopy (EPRS) as the method of detection. It was found to have an error in the order of +/-10% and a detection limit of 0.010 mM (0.5 mg l(-1)) chromium(V). The method has been used to quantitate the formation of chromium(V) in the interaction of chromium(VI) with fulvic acid and a simple model of this acid, viz, 1.2-dihydroxybenzene. Analysis of solutions obtained from the reaction of 1,2-dihydroxybenzene with chromium(VI) demonstrated that even when the organic substrate was present in a 182-fold excess, the maximum chromium(V) concentration attained represented just 1.44% of the initial chromium(VI). Reactions between chromium(VI) and fulvic acid yielded similar results. It was therefore concluded that at background environmental concentrations of chromium and fulvic acid, the production of chromium(V) is insignificant, however, its possible importance in contaminated systems cannot be disregarded on this basis alone. The method for quantitative analysis reported in this paper should be an invaluable tool for investigations into the significance of chromium(V) in the toxicological mechanism of chromium(VI) and its role as a mutagenic agent.  相似文献   

17.
The determination of free sulfide and cyanide by pulsed amperometric detection (PAD) at a silver-working electrode was improved through a deep de-oxygenation (at least 10 min) of both standard and real solutions containing the two analytes and adopting a two-potential waveform able to eliminate Ag working electrode fouling. The waveform stepped around the oxidation of Ag in the presence of 0.1-0.4 M hydroxyl ion, from -0.1 to 0.1 V versus saturated calomel electrode (SCE). The eluent composition (0.4 M NaOH plus 7.5 mM oxalate solution) allowed a very good column efficiency and selectivity. The presence of a polysulfide species was hypothesized in sulfide solutions that had not been de-oxygenated and aged. The polysulfide eluted just before sulfide and was confirmed by a chemical test with SO3(2-) producing the elimination of the polysulfide peak. Detection limits, according to the Hubaux-Vos method, were 1.0 and 2.0 microg/l for S2- and CN , respectively. We demonstrated good performance of the optimized method by repeatedly injecting standard solutions and by analyzing different real matrices. The method exhibited very good accuracy and repeatability (10 microg/l and a 500 microl injection loop, had a repeatability better than 3% for sulfide and 100 microg/l had a repeatability better than 1% for cyanide). The two-potential waveform ensured long-term stability of the electrode surface that required no manual polishing procedure for at least 1 month (20 analysis per day).  相似文献   

18.
The International Agency for Research on Cancer determined that bromate is a potential human carcinogen, even at low micro/l levels in drinking water. Bromate is commonly produced from the ozonation of source water containing naturally occurring bromide. Traditionally, trace concentrations of bromate and other oxyhalides in environmental waters have been determined by anion exchange chromatography with an IonPac AS9-HC column using a carbonate eluent and suppressed conductivity detection, as described in EPA Method 300.1 B. However, a hydroxide eluent has lower suppressed background conductivity and lower noise compared to a carbonate eluent and this can reduce the detection limit and practical quantitation limit for bromate. In this paper, we examine the effect of using an electrolytically generated hydroxide eluent combined with a novel hydroxide-selective anion exchange column for the determination of disinfection byproduct anions and bromide in municipal and bottled drinking water samples. EPA Methods 300.1 B and 317.0 were used as test criteria to evaluate the new anion exchange column. The combination of a hydroxide eluent with a high capacity hydroxide-selective column allowed sub-microg/l detection limits for chlorite, bromate, chlorate, and bromide with a practical quantitation limit of 1 microg/l bromate using suppressed conductivity detection and 0.5 microg/l using postcolumn addition of o-dianisidine followed by visible detection. The linearity, method detection limits, robustness, and accuracy of the methods for spiked municipal and bottled water samples will be discussed.  相似文献   

19.
Bromate deriving from ozonation treatment of bromide containing waters are analyzed by ion-exchange chromatography with spectrophotometric detection after post-column reaction with fuchsin in low pH medium. An anion-exchange column was used with 2.7 mM carbonate-0.3 mM hydrogencarbonate eluent. The eluent from the column was then allowed to react with a SO2-reduced fuchsin solution and then with a diluted HCl solution at 65 degrees C. The developed colour of the final product was measured spectrophotometrically at 530 nm. Linearity was checked up to 50 micrograms/l with a 200-microliter injection loop (r2 = 0.9997) and up to 100 micrograms/l of bromate with 100 microliters loop (r2 = 0.9939). Nitrate, sulfate, bromide, phosphate, fluoride did not interfere at 100 mg/l concentration level; only nitrite at concentration levels greater than 3 mg/l caused partial overlapping with bromate peak, but this value is not likely to occur in common drinking water. The detection limit (3 sigma) is 0.1 microgram/l (1 microgram/l propagation error approach).  相似文献   

20.
A new rapid and sensitive FI method is reported for spectrophotometric determination of trace chromium(VI) in electroplating waste water. The method is based on the reaction of Cr(VI) with sodium diphenylamine sulfonate (DPH) in acidic medium to form a purple complex (lambda(max) = 550 nm). Under the optimized conditions, the calibration curve is linear in the range 0.04-3.8 microg ml(-1) at a sampling rate of 30 h(-1). The detection limit of the method is 0.0217 microg ml(-1), and the relative standard deviation is 1.1% for eight determinations of 2 microg ml(-1) Cr(VI). The proposed method was applied to the determination of chromium in electroplating waste water with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号