 共查询到20条相似文献,搜索用时 15 毫秒
1.
Radial sampling has been demonstrated to be potentially useful in cardiac magnetic resonance imaging because it is less susceptible to motion than Cartesian sampling. Nevertheless, its capability of imaging acceleration remains limited by undersampling-induced streaking artifacts. In this study, a self-calibrated reconstruction method was developed to suppress streaking artifacts for highly accelerated parallel radial acquisitions in cardiac magnetic resonance imaging. Two- (2D) and three-dimensional (3D) radial k-space data were collected from a phantom and healthy volunteers. Images reconstructed using the proposed method and the conventional regridding method were compared based on statistical analysis on a four-point scale imaging scoring. It was demonstrated that the proposed method can effectively remove undersampling streaking artifacts and significantly improve image quality (P<.05). With the use of the proposed method, image score (1–4, 1=poor, 2=good, 3=very good, 4=excellent) was improved from 2.14 to 3.34 with the use of an undersampling factor of 4 and from 1.09 to 2.5 with the use of an undersampling factor of 8. Our study demonstrates that the proposed reconstruction method is effective for highly accelerated cardiac imaging applications using parallel radial acquisitions without calibration data.  相似文献   

2.
Diffusion weighted magnetic resonance imaging (DWI) has been mostly acquired using single-shot echo-planar imaging (ss EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in ss EPI especially for abdominal imaging, even with the advances in parallel imaging. A novel method of reduced Field of View ss EPI (rFOV ss EPI) has achieved high resolution DWI in human carotid artery, spinal cord with reduced blurring and higher spatial resolution than conventional ss EPI, but it has not been used to pancreas imaging. In the work, comparisons between the full FOV ss-DW EPI and rFOV ss-DW EPI in image qualities and ADC values of pancreatic tumors and normal pancreatic tissues were performed to demonstrate the feasibility of pancreatic high resolution rFOV DWI. There were no significant differences in the mean ADC values between full FOV DWI and rFOV DWI for the 17 subjects using b = 600 s/mm2 (P = 0.962). However, subjective scores of image quality was significantly higher at rFOV ss DWI (P = 0.008 and 0.000 for b-value = 0 s/mm2 and 600 s/mm2 respectively). The spatial resolution of DWI for pancreas was increased by a factor of over 2.0 (from almost 3.0 mm/pixel to 1.25 mm/pixel) using rFOV ss EPI technique. Reduced FOV ss EPI can provide good DW images and is promising to benefit applications for pancreatic diseases.  相似文献   

3.

Purpose

Greater spatial resolution in intracranial three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA) is possible at higher field strengths, due to the increased contrast-to-noise ratio (CNR) from the higher signal-to-noise ratio and the improved background suppression. However, at very high fields, spatial resolution is limited in practice by the acquisition time required for sequential phase encoding. In this study, we applied parallel imaging to 7T TOF MRA studies of normal volunteers and patients with vascular disease, in order to obtain very high resolution (0.12 mm3) images within a reasonable scan time.

Materials and Methods

Custom parallel imaging acquisition and reconstruction methods were developed for 7T MRA, based on generalized autocalibrating partially parallel acquisition (GRAPPA). The techniques were compared and applied to studies of seven normal volunteers and three patients with cerebrovascular disease.

Results

The technique produced high resolution studies free from discernible reconstruction artifacts in all subjects and provided excellent depiction of vascular pathology in patients.

Conclusions

7T TOF MRA with parallel imaging is a valuable noninvasive angiographic technique that can attain very high spatial resolution.  相似文献   

4.
Evaluation of motion effects on parallel MR imaging with precalibration   总被引:1,自引:1,他引:0  
Several parallel imaging techniques such as SMASH, SENSE, k-space inherited parallel acquisition (KIPA) and others use reference (calibration) scans to find the parameters required for image reconstruction. Reference data is used to estimate coil sensitivity profiles for image domain techniques such as SENSE or reconstruction coefficients for k-space domain methods such as SMASH and KIPA. Any motion between the reference and accelerated imaging scans can make the reconstruction coefficients determined from the reference scan data suboptimal, resulting in an artifactual reconstruction. This work aims at comparing the effects of motion on the performance of three parallel imaging methods: SENSE, variable-density SENSE and KIPA, which all require one or more reference scans for calibration.  相似文献   

5.
Specialized implants are used for transcatheter closure of septal defects, including atrial and ventricular septal defects, and patent foramen ovale. These metallic devices may pose a risk to patients undergoing magnetic resonance imaging (MRI) procedures especially if performed at 3 T. Therefore, this investigation evaluated MRI safety at 3 T for septal repair implants (CardioSEAL Septal Repair Implant and STARFlex Septal Repair Implant, NMT Medical, Boston, MA, USA) by characterizing magnetic field interactions, heating and artifacts. These implants exhibited minor magnetic field interactions; heating was not excessive (+0.5°C); and artifacts will only create a problem if the area of interest is in the same area as or near these devices. Thus, the findings indicated that it would be safe for a patient with these implants to undergo MRI at 3 T or lower. Importantly, because of the minor magnetic field interactions, MRI may be performed immediately after implantation.  相似文献   

6.
Surface-based functional magnetic resonance imaging (fMRI) analysis is more sensitive and accurate than volume-based analysis for detecting neural activation. However, these advantages are less important in practical fMRI experiments with commonly used 1.5-T magnetic resonance devices because of the resolution gap between the echo planar imaging data and the cortical surface models. We expected high-resolution segmented partial brain echo planar imaging (EPI) data to overcome this problem, and the activation patterns of the high-resolution data could be different from the low-resolution data. For the practical applications of surface-based fMRI analysis using segmented EPI techniques, the effects of some important factors (e.g., activation patterns, registration and local distortions) should be intensively evaluated because the results of surface-based fMRI analyses could be influenced by them. In this study, we demonstrated the difference between activations detected from low-resolution EPI data, which were covering whole brain, and high-resolution segmented EPI data covering partial brain by volume- and surface-based analysis methods. First, we compared the activation maps of low- and high-resolution EPI datasets detected by volume- and surface-based analyses, with the spatial patterns of activation clusters, and analyzed the distributions of activations in occipital lobes. We also analyzed the high-resolution EPI data covering motor areas and fusiform gyri of human brain, and presented the differences of activations detected by volume- and surface-based methods.  相似文献   

7.
Malignant glioma is a rare tumor type characterized by prominent vascular proliferation. Antiangiogenic therapy with the monoclonal antibody bevacizumab is considered as a promising therapeutic strategy, although the effect on tumor vascularization is unclear. High-field susceptibility-weighted imaging (SWI) visualizes the microvasculature and may contribute to the investigation of antiangiogenic therapy responses in gliomas. We prospectively studied five adult malignant glioma patients treated with bevacizumab-containing regimens. In each patient, we performed three 7-T SWI and T1-weighted imaging investigations (baseline and 2 and 4 weeks after the start of bevacizumab treatment). In addition, we imaged a postmortem brain of a patient with glioblastoma using 7-T SWI and performed detailed histopathological analysis. We observed almost total resolution of brain edema in three of five patients after initiation of bevacizumab therapy. In one case with rapid increase of the lesion size despite bevacizumab therapy, SWI showed progressive increase of irregular hypointense structures, most likely corresponding to increasing amounts of pathological microvasculature. In one case with progressive neurological decline, 7-T images showed multiple intratumoral microhemorrhages after the first bevacizumab application. Correlation of postmortem neuroimaging with histopathology confirmed that SWI-positive structures correspond to tumor vasculature. The experience from our case series indicates that longitudinal 7-T SWI seems to be an appropriate method for investigation of changes in brain tumor vascularization over time under antiangiogenic therapy.  相似文献   

8.
9.
The concept of density-weighted imaging and parallel acquisition for effective density-weighted (PLANED) imaging was transferred to saturation recovery (SR) sequences, in order to increase the SNR in first-pass myocardial perfusion imaging. Filtering in combination with density-weighted imaging allows SNR-optimized data weighting and the free choice of the corresponding spatial response function (SRF) simultaneously. This method was evaluated in simulations and applied successfully to phantom and in vivo first-pass myocardial perfusion studies. Unfiltered, Cartesian sampled images were compared to images acquired with SR-PLANED, which has been adjusted to result in an identical SRF as the Cartesian imaging. SNR-optimized SR-PLANED imaging improved the SNR up to 15% without changing acquisition time, the SRF or the field of view (FOV). The presented method provides high image quality and optimized SNR for first-pass myocardial perfusion imaging.  相似文献   

10.
Magnetic resonance imaging (MRI) can now provide maps of human brain function with high spatial and temporal resolution. This noninvasive technique can also map the coritical activation that occurs during focal seizures, as demonstrated here by the results obtained using a conventional 1.5 T clinical MRI system for the investigation of a 4-year-old boy suffering from frequent partial motor seizures of his right side. FLASH images (TE = 60 ms) were acquired every 10 s over a period of 25 min, and activation images derived by subtracting baseline images from images obtained during clinical seizures. Functional MRI revealed sequential activation associated with specific gyri within the left hemisphere with each of five consecutive clinical seizures, and also during a period that was not associated with a detectable clinical seizure. The activated regions included gyri that were structurally abnormal. These results demonstrate (a) that functional MRI can potentially provide new insights into the dynamic events that occur in the epileptic brain and their relationship to brain structure; and (b) that there is the possibility of obtaining similar information in the absence of clinical seizures, suggesting the potential for studies in patients with interictal electrical disturbances.  相似文献   

11.
Joint estimation of coil sensitivities and output image (JSENSE) is a promising approach that improves the reconstruction of parallel magnetic resonance imaging (pMRI). However, when acceleration factor increases, the signal to noise ratio (SNR) of JSENSE reconstruction decreases as quickly as that of the conventional pMRI. Although sparse constraints have been used to improve the JSENSE reconstruction in recent years, these constraints only use the sparsity of the output image, which cannot fully exploit the prior information of pMRI. In this paper, we use the sparsity of coil images, instead of the output image, to exploit more prior information for JSENSE. Numerical simulation, phantom and in vivo experiments demonstrate that the proposed method has better performance than the SparseSENSE method and the constrained JSENSE method using the sparsity of the output image only.  相似文献   

12.
There has been much recent interest in extending the technique of magnetic resonance imaging (MRI) down to the level of single spins with sub-optical wavelength resolution. However, the signal to noise ratio for images of individual spins is usually low and this necessitates long acquisition times and low temperatures to achieve high resolution. An exception to this is the nitrogen-vacancy (NV) color center in diamond whose spin state can be detected optically at room temperature. Here we apply MRI to magnetically equivalent NV spins and demonstrate fully resolved spectra with resolution well below the optical wavelength of the readout light. In addition, using a microwave version of MRI we achieved a resolution that is 1/270 in size of the coplanar striplines, which define the effective wavelength of the microwaves that were used to excite the transition. This technique can eventually be extended to imaging of large numbers of NVs in a confocal spot and possibly to image nearby dark spins via their mutual magnetic interaction with the NV spin.  相似文献   

13.
Magnetic Resonance Spectroscopic Imaging (MRSI) is a technique for imaging spatial variation of metabolites and has been very useful in characterizing biochemical changes associated with disease as well as response to therapy in malignant pathologies. This work presents a self-calibrated undersampling to accelerate 3D elliptical MRSI and an extrapolation-reconstruction algorithm based on the GRAPPA method. The accelerated MRSI technique was tested in three volunteers and five brain tumor patients. Acceleration allowed larger spatial coverage and consequently, less lipid contamination in spectra, compared to fully sampled acquisition within the same scantime. Metabolite concentrations measured from the accelerated acquisitions were in good agreement with measurements obtained from fully sampled MRSI scans.  相似文献   

14.
High-resolution magnetic resonance imaging using dedicated high-field radiofrequency micro-coils at 16.4 T (700 MHz) was investigated. Specific solenoid coils primarily using silver and copper as conductors with enamel and polyurethane coatings were built to establish which coil configuration produces the best image. Image quality was quantified using signal-to-noise ratio and signal variation over regions of interest. Benchmarking was conducted using 5-mm diameter coils, as this size is comparable to an established coil of the same size. Our 1.4-mm-diameter coils were compared directly to each other, from which we deduce performance as a function of conductor material and coating. A variety of materials and conductor coatings allowed us to choose an optimal design, which we used to image a kidney section at 10-micron resolution. We applied zero-fill extrapolation to achieve 5-micron resolution.  相似文献   

15.
Susceptibility-weighted imaging (SWI) is a valuable technique for high-resolution imaging of brain vasculature that greatly benefits from the emergence of higher field strength MR scanners. Autocalibrating partially parallel imaging techniques can be employed to reduce lengthy acquisition times as long as the decrease in signal-to-noise ratio does not significantly affect the contrast between vessels and brain parenchyma. This study assessed the feasibility of a Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA)-based SWI technique at 7 T in both healthy volunteers and brain tumor patients. GRAPPA-based SWI allowed a twofold or more reduction in scan time without compromising vessel contrast and small vessel detection. Postprocessing parameters for the SWI needed to be modified for patients where the tumor causes high-frequency phase wrap artifacts but did not adversely affect vessel contrast. GRAPPA-based SWI at 7 T revealed regions of microvascularity, hemorrhage and calcification within heterogeneous brain tumors that may aid in characterizing active or necrotic tumor and monitoring treatment effects.  相似文献   

16.
17.
马亚军  李莎  高嵩 《中国物理 B》2017,26(11):118701-118701
Controlled aliasing in parallel imaging results in higher acceleration(CAIPIRINHA) for simultaneous multislice imaging has been proposed recently, which combines multiband excitation and phase cycling techniques to reduce scan time and improve subsequent imaging reconstruction. In this work, the total variation(TV) regularization method is used to further improve CAIPIRINHA. The TV regularization uses an edge-preserving prior, which establishes a relationship between neighboring pixels for image reconstruction. It reduces artifacts and suppresses noise amplification simultaneously.The results are presented with a standard eight-channel head coil with an acceleration factor of 4, where the TV-regularized CAIPIRINHA generates an improved reconstruction as compared with a typical nonregularized CAIPIRINHA.  相似文献   

18.
This work investigated macrophages labeled with magnetosomes for the possible detection of inflammations by MR molecular imaging. Pure magnetosomes and macrophages containing magnetosomes were analyzed using a clinical 1.5 T MR-scanner. Relaxivities of magnetosomes and relaxation rates of cells containing magnetosomes were determined. Peritonitis was induced in two mice. T1, T2 and T2* weighted images were acquired following injection of the probes. Pure magnetosomes and labeled cells showed slight effects on T1, but strong effects on T2 and T2* images. Labeled macrophages were located with magnetic resonance imaging (MRI) in the colon area, thus demonstrating the feasibility of the proposed approach.  相似文献   

19.

Purpose

The goal of this study was to implement time efficient data acquisition and reconstruction methods for 3D magnetic resonance spectroscopic imaging (MRSI) of gliomas at a field strength of 3T using parallel imaging techniques.

Methods

The point spread functions, signal to noise ratio (SNR), spatial resolution, metabolite intensity distributions and Cho:NAA ratio of 3D ellipsoidal, 3D sensitivity encoding (SENSE) and 3D combined ellipsoidal and SENSE (e-SENSE) k-space sampling schemes were compared with conventional k-space data acquisition methods.

Results

The 3D SENSE and e-SENSE methods resulted in similar spectral patterns as the conventional MRSI methods. The Cho:NAA ratios were highly correlated (P<.05 for SENSE and P<.001 for e-SENSE) with the ellipsoidal method and all methods exhibited significantly different spectral patterns in tumor regions compared to normal appearing white matter. The geometry factors ranged between 1.2 and 1.3 for both the SENSE and e-SENSE spectra. When corrected for these factors and for differences in data acquisition times, the empirical SNRs were similar to values expected based upon theoretical grounds. The effective spatial resolution of the SENSE spectra was estimated to be same as the corresponding fully sampled k-space data, while the spectra acquired with ellipsoidal and e-SENSE k-space samplings were estimated to have a 2.36–2.47-fold loss in spatial resolution due to the differences in their point spread functions.

Conclusion

The 3D SENSE method retained the same spatial resolution as full k-space sampling but with a 4-fold reduction in scan time and an acquisition time of 9.28 min. The 3D e-SENSE method had a similar spatial resolution as the corresponding ellipsoidal sampling with a scan time of 4:36 min. Both parallel imaging methods provided clinically interpretable spectra with volumetric coverage and adequate SNR for evaluating Cho, Cr and NAA.  相似文献   

20.
Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) studies using parallel imaging to reduce the readout window have reported a loss in temporal signal-to-noise ratio (SNR) that is less than would be expected given a purely thermal noise model. In this study, the impact of parallel imaging on the noise components and functional sensitivity of both BOLD and perfusion-based fMRI data was investigated. Dual-echo arterial spin labeling data were acquired on five subjects using sensitivity encoding (SENSE), at reduction factors (R) of 1, 2 and 3. Direct recording of cardiac and respiratory activity during data acquisition enabled the retrospective removal of physiological noise. The temporal SNR of the perfusion time series closely followed the thermal noise prediction of a √R loss in SNR as the readout window was shortened, with temporal SNR values (relative to the R=1 data) of 0.72 and 0.56 for the R=2 and R=3 data, respectively, after accounting for physiological noise. However, the BOLD temporal SNR decreased more slowly than predicted even after accounting for physiological noise, with relative temporal SNR values of 0.80 and 0.63 for the R=2 and R=3 data, respectively. Spectral analysis revealed that the BOLD trends were dominated by low-frequency fluctuations, which were not dominant in the perfusion data due to signal processing differences. The functional sensitivity, assessed using mean F values over activated regions of interest (ROIs), followed the temporal SNR trends for the BOLD data. However, results for the perfusion data were more dependent on the threshold used for ROI selection, most likely due to the inherently low SNR of functional perfusion data.  相似文献   