1.
This work investigated the repeatability of column preparation for a reversed-phase C18 monolith, namely stearyl methacrylate-co-ethylene glycol dimethacrylate (SMA-EDMA). The columns were thermally polymerised using three commonly available heating devices (GC oven, hot air oven and water bath) and their chromatographic performance evaluated using micro-liquid chromatography for separation of five test compounds. Precision in terms of %RSD of retention times were 9.0, 6.5, and 12.5 using GC oven, hot air oven and water bath, respectively. Between-batch precision for the hot air oven (n = 3 days) was less than 10.4% for retention time. The SMA-EDMA monolith was applied to the separation of tocopherol homologues by capillary electrochromatography. Usually tocopherol homologues cannot be completely separated by conventional reversed-phase C8- or C18-packed bed or C18-silica based monolithic columns. Polymer monolith has been shown to give remarkable selectivity towards the tocopherols compared to the conventional microparticulate phase and silica based monolith. Successful separation of the tocopherol isomers was achieved on the SMA-EDMA monolith without any column modification.  相似文献   

2.
Analytical scale silica monoliths are commercially limited to three column selectivities (bare silica, C8 and C18). An in situ modification is reported in detail to overcome this barrier and allow for any functionality of choice to be bonded to the silica surface of the monolithic stationary phase support. The modification method was conducted on a commercial bare silica column to bond the C18 moiety to the silica surface through a silylation reaction. The C18 type of stationary phase was chosen, as this is the most commonly bonded functionality for the majority of stationary phases used for high-performance liquid chromatography (HPLC) separations. The C18-modified monolith’s performance was compared to a commercial C18 monolithic and a particle packed column of the same analytical scale column dimensions (100 × 4.6 mm). The modified C18 monolith proved to be of high quality with an efficiency of 73,267 N m?1, fast analysis times (operated at flow rates up to 3 mL min?1 using a conventional 400 bar HPLC system) and improved resolution of a set of polar and non-polar substituted aromatics in comparison to a commercial C18 monolith.  相似文献   

3.
The synthesis and chromatographic behavior of an analytical size mixed‐mode bonded silica monolith was investigated. The monolith was functionalized by an in situ modification process of a bare silica rod with chloro(3‐cyanopropyl)dimethyl silane and chlorodimethyl propyl phenyl silane solutions. These ligands were selected in order to combine both resonance and nonresonance π‐type bonding within a single separation environment. Selectivity studies were undertaken using n‐alkyl benzenes and polycyclic aromatic hydrocarbons in aqueous methanol and acetonitrile mobile phases to assess the methylene and aromatic selectivities of the column. The results fit with the linear solvent strength theory suggesting excellent selectivity of the column was achieved. Comparison studies were performed on monolithic columns that were functionalized separately with cyano and phenyl ligands, suggesting highly conjugated molecules were able to successfully exploit both of the π‐type selectivities afforded by the two different ligands on the mixed‐mode column.  相似文献   

4.
We here report a new type of stationary phase for microcolumns. C18 modified silica monolith particles were prepared by grinding and sieving the silica monolith followed by C18 modification and end-capping, and were used as packing material. Ground silica monolith particles were not spherical but irregular with some residual monolithic network structure. The separation efficiency of the stationary phase made of sieved monolith particles (5-10 microm) was better than that of the stationary phase made of unsieved particles. The microcolumn packed with the sieved C18 ground monolith particles (5-10 microm) showed quite good separation efficiency (height equivalent to theoretical plate, HETP, as low as 15 microm) and it was even superior to the microcolumn packed with a commercial spherical 5 microm C18 stationary phase. The column pressure drop of C18 monolith particles was about two-third of that of the commercial spherical C18 phase. The preparation method of C18 stationary phase with ground and sieved silica monolith particles presumably suggests advantages of simplicity and convenience in modification and washing procedures compared to bulk silica monolith. It also showed both improved separation efficiency and low back pressure.  相似文献   

5.
A 10 cm silica monolith has been modified with iminodiacetic acid (IDA) groups and characterised for its selectivity toward alkali, alkaline earth, and selected transition metal cations. Physical characterisation of the modified monolith found non-homogeneous modification along the length of the monolith, although sufficient capacity was achieved to facilitate significant retention of alkaline earth and transition/heavy metal ions over a range of eluent pH and ionic strength conditions. For alkaline earth and transition/heavy metal ions, selectivity of the 10 cm IDA monolith closely matched that seen with a 25 cm IDA modified silica gel particle packed column, although the separation of alkali metal ions was noticeably poorer on the monolithic column. Peak efficiencies for most metal ions were of a similar order for both column types, except for Zn(II), which showed significant peak broadening on the IDA monolithic column.  相似文献   

6.
Ground porous silica monolith particles with an average particle size of 2.34 μm and large pores (363 Å) exhibiting excellent chromatographic performance have been synthesized on a relatively large scale by a sophisticated sol–gel procedure. The particle size distribution was rather broad, and the d(0.1)/d(0.9) ratio was 0.14. The resultant silica monolith particles were chemically modified with chlorodimethyloctadecylsilane and end‐capped with a mixture of hexamethyldisilazane and chlorotrimethylsilane. Very good separation efficiency (185 000/m) and chromatographic resolution were achieved when the C18‐bound phase was evaluated for a test mixture of five benzene derivatives after packing in a stainless‐steel column (1.0 mm × 150 mm). The optimized elution conditions were found to be 70:30 v/v acetonitrile/water with 0.1% trifluoroacetic acid at a flow rate of 25 μL/min. The column was also evaluated for fast analysis at a flow rate of 100 μL/min, and all the five analytes were eluted within 3.5 min with reasonable efficiency (ca. 60 000/m) and resolution. The strategy of using particles with reduced particle size and large pores (363 Å) combined with C18 modification in addition to partial‐monolithic architecture has resulted in a useful stationary phase (C18‐bound silica monolith particles) of low production cost showing excellent chromatographic performance.  相似文献   

7.
Highly selective molecularly imprinted layer-coated silica nanoparticles for bisphenol A (BPA) were synthesized by molecular imprinting technique with a sol-gel process on the supporter of silica nanoparticles. The BPA-imprinted silica nanoparticles were characterized by fourier transform infrared spectrometer, transmission electron microscope, dynamic adsorption and static adsorption tests. The equilibrium association constant, Ka, and the apparent maximum number of binding sites, Qmax, were estimated to be 1.25 × 105 mL μmol−1 and 16.4 μmol g−1, respectively. The BPA-imprinted silica nanoparticles solid-phase extraction (SPE) column had higher selectivity for BPA than the commercial C18-SPE column. The results of the study indicated that the prepared BPA-imprinted silica nanoparticles exhibited high adsorption capacity and selectivity, and offered a fast kinetics for the rebinding of BPA. The BPA-imprinted silica nanoparticles were successfully used in SPE to selectively enrich and determine BPA from shampoo, bath lotion and cosmetic cream samples.  相似文献   

8.
A silica monolith column (Merck Chromolith, 100 mm x 4.6 mm) has been coated with Dionex AS9-SC latex nanoparticles to convert the column into an anion-exchange stationary phase. For comparison purposes, a reversed-phase silica monolith was also converted into an anion-exchange column by coating with the cationic surfactant didodecyldimethylammonium bromide (DDAB). Separations of common inorganic anions were carried out using 7.5 or 5.0 mM 4-hydroxybenzoic acid at pH 7.0 along with suppressed conductivity detection. Direct comparisons were then made between the two columns in terms of selectivity, efficiency and stability. The latex-coated column was on average 50% more efficient than the DDAB-coated column. A 10% decrease in retention times was observed on the DDAB column over 11 h of continuous eluent flow, while the latex coating exhibited <1% change in retention even after 2.5 months of periodic use.  相似文献   

9.
An affinity monolith based on silica and containing immobilized alpha(1)-acid glycoprotein (AGP) was developed and evaluated in terms of its binding, efficiency and selectivity in chiral separations. The results were compared with data obtained for the same protein when used as a chiral stationary phase with HPLC-grade silica particles or monoliths based on a copolymer of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA). The surface coverage of AGP in the silica monolith was 18% higher than that obtained with silica particles and 61% higher than that measured for a GMA/EDMA monolith. The higher surface area of the silica monolith gave materials that contained 1.5- to 3.6-times more immobilized protein per unit volume when compared to silica particles or a GMA/EDMA monolith. The retention, efficiency and resolving power of the AGP silica monolith were evaluated by injecting two chiral analytes onto this column (i.e., R/S-warfarin and R/S-propranolol). In each case, the AGP silica monolith gave higher retention plus better resolution and efficiency than AGP columns containing silica particles or a GMA/EDMA monolith. The AGP silica monolith also gave lower back pressures and separation impedances than these other materials. It was concluded that silica monoliths can be valuable alternatives to silica particles or GMA/EDMA monoliths when used with AGP as a chiral stationary phase.  相似文献   

10.
A novel type of macroporous molecularly imprinted hybrid silica monolithic column was first developed for recognition of proteins. The macroporous silica-based monolithic skeleton was synthesized in a 4.6 mm i.d. stainless steel column by a mild sol–gel process with methyltrimethoxysilane (MTMS) as a sole precursor, and then vinyl groups were introduced onto the surface of the silica skeleton by chemical modification of γ-methacryloxypropyltrimethoxysilane (γ-MAPS). Subsequently, the molecularly imprinted polymer (MIP) coating was copolymerized and anchored onto the surface of the silica monolith. Bovine serum albumin (BSA) and lysozyme (Lyz), which differ greatly in molecular size, isoelectric point, and charge, were representatively selected for imprinted templates to evaluate recognition property of the hybrid silica-based MIP monolith. Some important factors, such as template–monomer molar ratio, total monomer concentration and crosslinking density, were systematically investigated. Under the optimum conditions, the obtained hybrid silica-based MIP monolith showed higher binding affinity for template than its corresponding non-imprinted (NIP) monolith. The imprinted factor (IF) for BSA and Lyz reached 9.07 and 6.52, respectively. Moreover, the hybrid silica-based MIP monolith displayed favorable binding characteristics for template over competitive protein. Compared with the imprinted silica beads for stationary phase and in situ organic polymer-based hydrogel MIP monolith, the hybrid silica MIP monolith exhibited higher recognition, stability and lifetime.  相似文献   

11.
Xiangli Sun  Yukui Zhang 《Talanta》2010,82(1):404-5307
A simple one-step in situ “click” modification strategy was developed for the preparation of hydrophobic organic monolithic columns for the first time. The column morphology and surface chemistry of the fabricated monolithic columns were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy, respectively. The chromatographic performances of the C8/C18 “click” monoliths were evaluated through the separation of a mixture of five proteins such as ribonuclease A, soybean trypsin inhibitor, cytochrome c, bovine haemoglobin and bovine serum albumin. Compared with the blank column, the higher hydrophobicity stationary phases obtained from the “clicked” modification have longer retention times and higher resolution for the five proteins. The separation of five proteins mixture on click C18 monolith with gradient elution at different flow rates was also investigated, the baseline separation of five proteins could be achieved at three different flow rates.  相似文献   

12.
In this study, the analysis of a peptide set, chosen for their differences in hydrophilicity, and the tryptic digests of bovine cytochrome c and β-lactoglobulin by hydrophilic interaction chromatography–electrospray ionisation mass spectrometry (HILIC–ESI-MS) is demonstrated. Two different types of HILIC phases, i.e., an amide- and an amino-modified silica-based phase, packed into narrow bore or capillary columns, were investigated with separations conducted under either low pH or neutral pH conditions. The separation performance of the two HILIC columns with respect to peak efficiency and selectivity have been documented under these different mobile phase conditions, and the results compared with the performance of a conventional capillary reversed-phase C18 column of similar dimensions. It was found that very good separation of the peptide set could be achieved by using the amide-modified silica column over a broad pH range. Moreover, with the protein digest samples, excellent separation of the tryptic digests was obtained with the amide-modified HILIC column under neutral pH conditions. Compared to the conventional reversed-phase C18 separations, the use of these HILIC columns not only provided complementary separation selectivity, but also offered the capability to identify unique peptides using tandem HILIC–mass spectrometric techniques. These studies therefore highlight the potential of HILIC procedures for future proteomic applications.  相似文献   

13.
A novel precursor monolithic capillary column referred to as “hydroxy monolith” or OHM was prepared by the in situ copolymerization of hydroxyethylmethacrylate (HEMA) with pentaerythritol triacrylate (PETA) yielding the neutral poly(HEMA‐co‐PETA) monolith. The neutral precursor OHM capillary thus obtained was subjected to postpolymerization modifications of the hydroxyl functional groups present on its surface with 1,2‐epoxyalkanes catalyzed by boron trifluoride (BF3) ultimately providing Epoxy OHM C‐m capillary column at varying alkyl chain lengths where m = 8, 12, 14, and 16 for RP‐CEC. Also, the same precursor OHM was grafted with octadecyl isocyanate yielding Isocyanato OHM C‐18 column to provide an insight into the effect of the nature of the linkage to the surface hydroxyl groups of the OHM precursor. While the epoxide reaction leaves on the surface of the OHM precursor hydroxy‐ether linkages, the isocyanato reaction leaves carbamate linkages on the same surface of the OHM precursor. This study revealed that changing the alkyl chain length resulted in changing the column phase ratio (?) and also the solute distribution constant (K). While increasing the surface alkyl chain length increased steeply the solute hydrophobic selectivity, i.e. methylene group selectivity, the nature of the ligand linkage produced different retention for the same solutes and affected the selectivity of slightly polar solutes. The various monoliths proved very useful for RP‐CEC of different small solutes at varying polarity over a wide range of mobile phase composition.  相似文献   

14.
Ionic liquid-modified silica, with functional groups based on imidazole as the cation, was obtained. A molecular imprinting technique was introduced to form the order of functional groups. The selectivity of the obtained ionic liquid-modified silica was successfully used as a special imprinted sorbent in the solid-phase extraction to isolate cryptotanshinone, tanshinone I and tanshinone IIA from Salvia miltiorrhiza Bunge. Several washing and elution solvents with different polarities were evaluated. The ionic liquid-modified silica as the sorbent exhibited a higher selectivity than blank ionic liquid-modified silica, traditional silica and C18 cartridges. A quantitative analysis was conducted by liquid chromatography with a C18 column and methanol/water (75:25, v/v, containing 0.5% acetic acid) as the mobile phase. A good linearity was obtained from 0.5 × 10?4 to 0.1 mg mL?1 (r 2  > 0.99) with relative standard deviations that were less than 4.6%.  相似文献   

15.
This article describes the synthesis, chromatographic characterization, and performance evaluation of analytical (100 x 4.6 mm id) and semipreparative (100 x 10 mm id) monolithic silica columns with mixed-mode RP/weak anion-exchange (RP/WAX) surface modification. The monolithic RP/WAX columns were obtained by immobilization of N-(10-undecenoyl)-3-aminoquinuclidine onto thiol-modified monolithic silica columns (Chromolith) by a radical addition reaction. Their chromatographic characterization by Engelhardt and Tanaka tests revealed slightly lower hydrophobic selectivities than C-8 phases, as well as higher polarity and also improved shape selectivity than RP-18e silica rods. The surface modification enabled separation by both RP and anion-exchange chromatography principles, and thus showed complementary selectivities to the RP-18e monoliths. The mixed-mode monoliths have been tested for the separation of peptides and turned out to be particularly useful for hydrophilic acidic peptides, which are usually insufficiently retained on RP-18e monolithic columns. Compared to a corresponding particulate RP/WAX column (5 microm, 10 nm pore diameter), the analytical RP/WAX monolith caused lower system pressure drops and showed, as expected, higher efficiency (e.g. by a factor of about 2.5 lower C-term for a tetrapeptide). The upscaling from the analytical to semipreparative column dimension was also successful.  相似文献   

16.
《中国化学快报》2021,32(11):3398-3401
A hydrophobic carbon dots (Glc-OCDs) derived from octadecylamine and glucose were successfully synthesized for the first time and then grafted onto the porous silica surface by the “Nano-on-Micro” strategy, which was served as a new stationary phase (Sil-Glc-OCDs) for reversed-phase liquid chromatography. The structure of this stationary phase was carefully verified by laser scanning confocal microscope, Fourier transform infrared spectrometry, elemental analysis, contact angle measurement, etc. Several analytes including seven polycyclic aromatic hydrocarbons, eight alkylbenzenes, eight phenols and seven sulfonamides can be well separated on this stationary phase. Better separation performance for certain analytes over commercial C18 column was obtained. Interestingly, this stationary phase exhibited excellent chromatographic selectivity in the separation of the isomers of tert‑butylbenzene, sec‑butylbenzene, isobutylbenzene and n-butylbenzene. In addition, this new Sil-Glc-OCDs column was also applied for detection of calycosin-7-glucoside, ononin, calycosin, formononetin, genistein and isorhamnetin in the extract of Radix Astragali, which were found that the concentration was 0.15 g/L, 0.088 g/L, 0.14 g/L, 0.086 g/L, 0.18 g/L and 0.29 g/L, respectively. We believe that this CDs-grafted silica materials are promising for chromatographic separation.  相似文献   

17.
A hybrid organic–inorganic silica monolith with hydrophobic and strong cation-exchange functional groups was prepared and used as a sorbent for micro-solid phase extraction (micro-SPE). The hybrid silica monolith functionalized with octyl and thiol groups was conveniently synthesized by hydrolysis and polycondensation of a mixture of tetraethoxysilane (TEOS), n-octyltriethoxysilane (C8-TEOS) and 3-mercaptopropyltrimethoxysilane (MPTMS) via a two-step catalytic sol–gel process. Due to the favorable chemical reactivity of mercapto pendant moieties, the obtained hybrid monolith was oxidized using hydrogen peroxide (30%, w/w) to yield sulfonic acid groups, which provided strong cation-exchange sites. The obtained hybrid monolith was characterized by diffused infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. The results show that the resulting monolith contains much higher carbon (31.6%) and sulfur (4.8%) contents than traditionally bonded silica materials. The extraction performance of the hybrid monolith was evaluated using sulfonamides as testing analytes by micro-SPE on-line coupled to HPLC. The results show that the hybrid monolith with hydrophobic and strong cation-exchange functional groups exhibits high extraction efficiency towards the testing analytes. The column-to-column RSD values were 1.3–9.8% for the extraction of SAs investigated. The extraction performance of the hybrid silica monolith remained practically unchanged after treated with acid (pH 1.0) and basic solutions (pH 10.5). Finally, the application of the hybrid monolith was demonstrated by micro-SPE of sulfonamide residues from milk followed by HPLC–UV analysis. The limits of detection (S/N = 3) for eight SAs were found to be 1.0–3.0 ng/mL in milk. The recoveries of eight SAs spiked in milk sample ranged from 80.2% to 115.6%, with relative standard deviations less than 11.8%.  相似文献   

18.
The overloaded band profiles of the protonated species of propranolol and amitriptyline were recorded under acidic conditions on four classes of stationary phases including a conventional silica/organic hybrid material in reversed‐phase liquid chromatography mode (BEH‐C18), an electrostatic repulsion reversed‐phase liquid chromatography C18 column (BEH‐C18+), a poly(styrene‐divinylbenzene) monolithic column, and a hydrophilic interaction chromatography stationary phase (underivatized BEH). The same amounts of protonated bases per unit volume of stationary phase were injected in each column (16, 47, and 141 μg/cm3). The performance of the propranolol/amitriptyline purification was assessed on the basis of the asymmetry of the recorded band profiles and on the selectivity factor achieved. The results show that the separation performed under reversed‐phase liquid chromatography like conditions (with BEH‐C18, BEH‐C18+, and polymer monolith materials) provide the largest selectivity factors due to the difference in the hydrophobic character of the two compounds. However, they also provide the most distorted overloaded band profiles due to a too small loading capacity. Remarkably, symmetric band profiles were observed with the hydrophilic interaction chromatography column. The larger loading capacity of the hydrophilic interaction chromatography column is due to the accumulation of the protonated bases into the diffuse water layer formed at the surface of the polar adsorbent. This work encourages purifying ionizable compounds on hydrophilic interaction chromatography columns rather than on reversed‐phase liquid chromatography columns.  相似文献   

19.
于欢  杨辉  姚睿  郭兴忠 《物理化学学报》2001,30(7):1384-1390
以溶胶-凝胶伴随相分离法制备的阶层多孔二氧化硅作为载体,3-氨丙基三乙氧基硅烷(APTES)为改性剂,乙醇为还原剂,在阶层多孔二氧化硅固体骨架上进行银纳米颗粒均匀负载. 利用扫描电镜(SEM)、透射电镜(TEM)、X射线衍射(XRD)、汞压、N2吸附/脱附、X射线光电子能谱(XPS)等测试技术对银纳米颗粒负载阶层多孔二氧化硅进行了表征,探讨了APTES表面改性、乙醇还原机理以及银纳米颗粒负载块体的孔结构特征变化规律. 结果表明:APTES表面改性将氨基接枝于阶层骨架上,氨基与银离子形成银氨离子,银氨离子经乙醇还原后将平均粒径约16 nm的银纳米颗粒成功负载于二氧化硅的大孔及介孔内部;负载后的阶层多孔块体的大孔骨架未受到破坏,但其比表面积由418 m2·g-1下降到254 m2·g-1,两次还原负载能提高银纳米颗粒的负载量.  相似文献   

20.
Various recent wide-pore reversed-phase stationary phases were studied for the analysis of intact monoclonal antibodies (mAbs) of 150 kDa and their fragments possessing sizes between 25 and 50 kDa. Different types of column technology were evaluated, namely, a prototype silica-based inorganic monolith containing mesopores of ~250 Å and macropores of ~?1.1 μm, a column packed with 3.6 μm wide-pore core-shell particles possessing a wide pore size distribution with an average around 200 Å and a column packed with fully porous 1.7 μm particles having pore size of ~300 Å. The performance of these wide-pore materials was compared with that of a poly(styrene–divinyl benzene) organic monolithic column, with a macropore size of approximately 1 μm but without mesopores (stagnant pores). A systematic investigation was carried out using model IgG1 and IgG2 mAbs, namely rituximab, panitumumab, and bevacizumab. Firstly, the recoveries of intact and reduced mAbs were compared on the two monolithic phases, and it appeared that adsorption was less pronounced on the organic monolith, probably due to the difference in chemistry (C18 versus phenyl) and the absence of mesopores (stagnant zones). Secondly, the kinetic performance was investigated in gradient elution mode for all columns. For this purpose, peak capacities per meter as well as peak capacities per time unit and per pressure unit (PPT) were calculated at various flow rates, to compare performance of columns with different dimensions. In terms of peak capacity per meter, the core-shell 3.6 μm and fully porous 1.7 μm columns outperformed the two monolithic phases, at a temperature of 60 °C. However, when considering the PPT values, the core-shell 3.6 μm column remained the best phase while the prototype silica-based monoliths became very interesting, mostly due to a very high permeability compared with the organic monolith. Therefore, these core-shell and silica-based monolith provided the fastest achievable separation. Finally, at the maximal working temperature of each column, the core-shell 3.6 μm column was far better than the other one, because it is the only one stable up to 90 °C. Lastly, the loading capacity was also measured on these four different phases. It appeared that the organic monolith was the less interesting and rapidly overloaded, due to the absence of mesopores. On the other hand, the loading capacity of prototype silica-based monolith was indeed reasonable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏