首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
张含智  李凤  康经武 《色谱》2023,41(2):160-167
毛细管电泳-质谱联用技术具有分离效率高、检测灵敏度高、样品消耗量少,可同时提供样品的结构信息等优点,成为复杂样品分离分析的强有力工具。但是,毛细管电泳与质谱联用的接口技术依然未能很好的解决。为了拓展我们发展的金箔包裹的毛细管电泳分离柱尖端直接作为喷雾电极和无鞘流质谱接口的应用,本文报道了用无鞘流接口毛细管电泳-电喷雾质谱联用(CE-ESI-MS)分析5种酪氨酸激酶抑制剂(舒尼替尼、甲磺酸伊马替尼、吉非替尼、达沙替尼、埃罗替尼)的研究结果。这种接口集分离与电喷雾离子化于一根毛细管中,制作简单,成本低廉,且可批量制作。实验发现采用非水毛细管电泳分离模式不仅可以对5种酪氨酸激酶抑制剂实现基线分离,而且可以获得稳定的质谱信号。考察了电解质溶液组成对分离效果的影响,得到优化的背景电解质组成,即含2%(v/v)乙酸及5 mmol/L乙酸铵的乙腈-甲醇(80∶20, v/v)混合溶剂。在优化的条件下,5种激酶抑制剂可以得到基线分离,无鞘接口也可以长时间保持稳定的电喷雾,分析物的保留时间日内、日间重复性(RSD值)分别小于0.5%和0.8%,接口批次间的RSD值小于2.6%。与水相分离条件下的CE-MS对比,非水相条件下的5种酪氨酸激酶抑制剂的分离柱效更高,检测灵敏度更高,绝对检出限达到amol级。此外,采用无鞘流CE-MS分析了各类有机酸(千层纸素A、丹酚酸C和迷迭香酸)和脂溶性的大环内酯类抗生素(阿奇霉素、红霉素和环孢素A),均可以获得良好的分离效果和质谱检测结果。  相似文献   

2.
The concept of interfacing a large-size column for capillary electrophoresis (CE) to electrospray ionization mass spectrometry (ESI-MS) for robust and automatic CE-MS operation is reported. Both standard ionspray interface and microionspray interface have been modified to operate in a sheath flow pattern to overcome the common stability problem in CE-MS coupling. To make the interface sensitive, a step-down stainless steel tube with smaller inner diameter and tapered tip was incorporated onto a larger tube embracing the CE column via cold soldering. The devices were evaluated for quantitative analysis of nucleotides at femtomole level and stable analytical performance in peptide profiling.  相似文献   

3.
A liquid-junction-type interface where a thin spraying capillary is inserted inside the separation capillary was constructed for coupling nonaqueous wide-bore capillary electrophoresis (CE) to mass spectrometry (MS). The robust structure of the interface provided fairly easy capillary handling. The study was carried out with uncoated CE capillaries of 200 and 320 microm inner diameter (ID). 1-Propanol-acetonitrile (80:20 v/v) with acetate electrolyte provided a low conducting medium for CE and good spraying conditions for electrospray ionization (ESI) without sheath-flow and drying gas. Methamphetamine, alprenolol, and levorphanol served as model compounds. Approximate detection limits with the 200 microm ID capillary were 35-265 ng/mL.  相似文献   

4.
Online coupling of capillary electrophoresis (CE) to electrospray ionization mass spectrometry (MS) has shown considerable potential, however, technical challenges have limited its use. In this study, we have developed a simple and sensitive sheathless CE-MS interface based on the novel concept of forming a sub-micrometer fracture directly in the capillary. The simple interface design allowed the generation of a stable ESI spray capable of ionization at low nanoliter flow-rates (45–90 nL/min) for high sensitivity MS analysis of challenging samples like those containing proteins and peptides. By analysis of a model peptide (leucine enkephalin), a limit of detection (LOD) of 0.045 pmol/μL (corresponding to 67 attomol in a sample volume of ∼15 nL) was obtained. The merit of the CE-MS approach was demonstrated by analysis of bovine serum albumin (BSA) tryptic peptides. A well-resolved separation profile was achieved and comparable sequence coverage was obtained by the CE-MS method (73%) compared to a representative UPLC-MS method (77%). The CE-MS interface was subsequently used to analyse a more complex sample of pharmaceutically relevant human proteins including insulin, tissue factor and α-synuclein. Efficient separation and protein ESI mass spectra of adequate quality could be achieved using only a small amount of sample (30 fmol). In addition, analysis of ubiquitin samples under both native and denatured conditions, indicate that the CE-MS setup can facilitate native MS applications to probe the conformational properties of proteins. Thus, the described CE-MS setup should be useful for a wide range of high-sensitivity applications in protein research.  相似文献   

5.
Stutz H 《Electrophoresis》2005,26(7-8):1254-1290
High throughput, outstanding certainty in peptide/protein identification, exceptional resolution, and quantitative information are essential pillars in proteome research. Capillary electrophoresis (CE) coupled to mass spectrometry (MS) has proven to meet these requirements. Soft ionization techniques, such as matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), have paved the way for the story of success of CE-MS in the analysis of biomolecules and both approaches are subject of discussion in this article. Meanwhile, CE-MS is far away from representing a homogeneous field. Therefore the review will cover a vast area including the coupling of different modes of CE (capillary zone electrophoresis, capillary isoelectric foscusing, capillary electrochromatography, micellar electrokinetic chromatography, nonaqueous capillary electrophoresis) to MS as well as on-line preconcentration techniques (transient capillary isotachophoresis, solid-phase extraction, membrane preconcentration) applied to compensate for restricted detection sensitivity. Special attention is given to improvements in interfacing, namely addressing nanospray and coaxial sheath liquid design. Peptide mapping, collision-induced dissociation with subsequent tandem MS, and amendments in mass accuracy of instruments improve information validity gained from MS data. With 2-D on-line coupling of liquid chromatography (LC) and CE a further topic will be discussed. A special section is dedicated to recent attempts in establishing CE-ESI-MS in proteomics, in the clinical and diagnostic field, and in the food sector.  相似文献   

6.
A pressurized liquid junction nanoelectrospray interface was designed and optimized for reliable on-line CE-MS coupling. The system was constructed as an integrated device for highly sensitive and selective analyses of proteins and peptides with the separation and spray capillaries fixed in a pressurized spray liquid reservoir equipped with the electrode for connection of the electrospray potential. The electrode chamber on the injection side of the separation capillary and the spray liquid reservoir were pneumatically connected by a Teflon tube filled with pressurized nitrogen. This arrangement provided precisely counterbalanced pressures at the inlet and outlet of the separation capillary. The pressure control system was driven by an electrically operated valve and maintained the optimum flow rate for the electrospray stability. All parts of the interface being in contact with the CEBGE, spray liquid and/or sample were made of glass or Teflon. The use of these materials minimized the electrospray chemical noise often caused by plastic softeners or material degradation. During optimization, the transfer of the separated zones between the separation and electrospray capillaries was monitored by UV absorbance and contactless conductivity detectors placed at the outlet of the separation capillary and inlet of the electrospray tip, respectively. This arrangement allowed independent monitoring of the effects of pressure, CE voltage and geometry of the liquid junction on the spreading and dilution of the separated zones after passage through the interface.  相似文献   

7.
A nonaqueous CE‐IT MS with a nanospray ionization interface method was developed for the identification and quantification of tetrandrine (TET), fangchinoline (FAN), and sinomenine (SIN) using berberine as internal standard. The TET, FAN, and SIN standard solutions were directly infused into IT‐MS for collecting MS1–3 spectra. The major fragment ions of analytes were confirmed and possible main cleavage pathways of fragment ions were studied. A bare fused‐silica capillary was used for separation of the analytes. A sheath liquid (50% aqueous methanol containing 0.2% acetic acid) to the capillary effluent with a nanoelectrospray ionization interface was added. Separation buffer comprised 80 mM solution of ammonium acetate, in a mixture of 70% methanol, 20% ACN, and 10% water, which also contained 1% acetic acid. The CE‐MS method was validated for linearity, sensitivity, accuracy, and precision, and then used to determine the content of the above components. The detection limits of TET, FAN, and SIN are 0.05, 0.08, and 0.15μg/mL, respectively. The precision was no more than 4.67% and the mean recovery of the analytes were 95.36–99.24%. This method was successfully applied to determine TET, FAN, and SIN in real samples radix Stephaniae tetrandrae and rhizomes of Menispermum dauricum.  相似文献   

8.
The combination of capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) via a triaxial interface was studied as a potential means for the characterization of intact proteins. To evaluate the possibility to use a nonvolatile electrolyte for CE, the effect of sodium phosphate and ammonium borate on the MS signal of the proteins insulin, myoglobin, and bovine serum albumin (BSA) was investigated by employing infusion experiments, and compared to the effect of ammonium formate and formic acid. The study shows that with formic acid (50 mM, pH 2.4) the most intense protein signals were obtained, while the use of sodium phosphate buffer (5 and 10 mM, pH 7.5) almost completely diminished the MS response. Ammonium formate and ammonium borate (up to 100 mM, pH 8.5) also caused protein ion suppression, but especially with the borate buffer significant MS intensity remained. MS analysis of myoglobin revealed the loss of the heme group when an acidic CE electrolyte was used. Using a background electrolyte containing 25 mM ammonium borate (pH 8.5), it is demonstrated that a CE separation of a protein test mixture can be monitored with ESI-MS without degrading the MS performance allowing molecular weight determinations of the separated compounds. In the presence of borate, detection limits were estimated to be 5-10 microM (ca. 100 fmol injected). The usefulness of the CE-MS system employing a borate buffer is indicated by the analysis of a stored sample of BSA revealing several degradation products. A sample of placental alkaline phosphatase (PLAP), a potential therapeutic agent, was also analyzed by CE-MS indicating the presence of a protein impurity. Probably due to insufficient ionization of the PLAP (a complex glycoprotein), no MS signals of the intact protein were observed.  相似文献   

9.
Developments in the fields of protein chemistry, proteomics and biotechnology have increased the demand for suitable analytical techniques for the analysis of intact proteins. In 1989, capillary electrophoresis (CE) was combined with mass spectrometry (MS) for the first time and its potential usefulness for the analysis of intact (i.e. non-digested) proteins was shown. This article provides an overview of the applications of CE-MS within the field of intact protein analysis. The principles of the applied CE modes and ionization techniques used for CE-MS of intact proteins are shortly described. It is shown that separations are predominantly carried out by capillary zone electrophoresis and capillary isoelectric focusing, whereas electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are the most popular ionization techniques used for interfacing. The combination of CE with inductively coupled plasma (ICP) MS for the analysis of metalloproteins is also discussed. The various CE-MS combinations are systematically outlined and tables provide extensive overviews of the applications of each technique for intact protein analysis. Selected examples are given to illustrate the usefulness of the CE-MS techniques. Examples include protein isoform assignment, single cell analysis, metalloprotein characterization, proteomics and biomarker screening. Finally, chip-based electrophoresis combined with MS is shortly treated and some of its applications are described. It is concluded that CE-MS represents a powerful tool for the analysis of intact proteins yielding unique separations and information.  相似文献   

10.
Methods for the determination of drug residues in water have been developed based on the combination of liquid chromatography (LC) or capillary electrophoresis (CE) with mass spectrometry (MS). For HPLC-MS two types of interfaces (pneumatically assisted electrospray ionization interface or an atmospheric pressure chemical ionization interface, respectively) were employed and compared in terms of detection limits. 2 mM Ammonium acetate at pH 5.5 and a methanol gradient was used for the HPLC-MS allowing the separation of a number of drugs such as paracetamol, clofibric acid, penicillin V, naproxen, bezafibrate, carbamazepine, diclofenac, ibuprofen and mefenamic acid. A 20 mM ammonium acetate solution, pH 5.1 was employed for the separation of clofibric acid, naproxen, bezafibrate, diclofenac, ibuprofen and mefenamic acid by CE-MS. Sample pretreatment was performed by solid-phase extraction (SPE) for HPLC-MS or by a combination of liquid-liquid extraction and SPE for CE-MS. The applicability of both the HPLC-MS and CE-MS method was demonstrated for several river water samples.  相似文献   

11.
Antithrombin (AT) is a plasma glycoprotein which possesses anticoagulant and anti-inflammatory properties. AT exhibits various forms, among which are native, latent and heterodimeric ones. We studied the potential of capillary electrophoresis-mass spectrometry (CE-MS) using a sheath liquid interface, electrospray ionization (ESI), and a quadrupole-time-of-flight (Q-TOF) mass spectrometer to separate and quantify the different AT forms. For CE separation, a neutral polyvinyl alcohol (PVA) coated capillary was employed. The protein conformation was preserved by using a background electrolyte (BGE) at physiological pH. A sheath liquid of isopropanol-water 50:50 (v/v) with 14 mM ammonium acetate delivered at a flow rate of 120 μL h−1 resulted in optimal signal intensities. Each AT form exhibited a specific mass spectrum, allowing unambiguous distinction. Several co-injection experiments proved that latent AT had a higher electrophoretic mobility (μep) than native AT, and that these conformers could associate to form a heterodimer during the CE analysis. The developed CE-MS method enabled the detection and quantitation of latent and heterodimeric forms in a commercial AT preparation stored at room temperature for three weeks.  相似文献   

12.
Souaïd E  Cottet H 《Electrophoresis》2005,26(17):3300-3306
The complexity in the mechanisms of polymerization of N-carboxyanhydrides requires the development of new analytical techniques able to separate mixtures of synthetic polypeptides. This work focuses on the separation of poly(N(epsilon)-trifluoroacetyl-L-lysine) (PTLL) mixtures by nonaqueous capillary electrophoresis (CE). The main goal of this work was to find electrophoretic conditions that permit the separation and the quantification of the dead polymer families that were previously identified in the samples. The influence of the pH of the electrolyte on the selectivity of the separation was carefully investigated. The mechanisms of separation of the PTTLs are discussed as a function of their ionization state. The separations obtained on a noncovalently coated capillary were compared with those obtained on a fused-silica capillary. Finally, using two different electrolytes, it is possible to quantify the three families of PTLLs, namely, the living PTLLs, the dead PTLLs with N-formyl end group and the dead PTLLs with a carboxylic end group. These results confirm the importance of CE for the separation of synthetic organic polymers in nonaqueous electrolytes.  相似文献   

13.
梁玉  张丽华  张玉奎 《色谱》2020,38(10):1117-1124
蛋白质组学研究在生物学、精准医学等方面发挥着重要的作用。然而研究面临的巨大挑战来自生物样品的复杂性,因此在质谱(MS)鉴定技术不断革新的同时,发展分离技术以降低样品复杂度尤为重要。毛细管电泳(CE)技术具有上样体积小、分离效率高、分离速度快等优势,其与质谱的联用在蛋白质组学研究中越来越受到关注。低流速鞘流液和无鞘流液接口的发展及商品化推动了CE-MS技术的发展。目前毛细管区带电泳(CZE)、毛细管等电聚焦(CIEF)、毛细管电色谱(CEC)等分离模式已与质谱联用,其中CZE-MS应用最广泛。目前被广泛采用的蛋白质组学研究策略主要是基于酶解肽段分离鉴定的"自下而上(bottom-up)"策略。首先,CE-MS技术对酶解肽段的检测灵敏度高达1 zmol,已成功应用于单细胞蛋白质组学;其次,毛细管电泳技术与反相液相色谱互补,为疏水性质相近的肽段(尤其是翻译后修饰肽段)的分离鉴定提供了新的途径。基于整体蛋白质分离鉴定的自上而下"top-down"策略可以直接获得更精准、更完整的蛋白质信息。CE技术在蛋白质大分子的分离方面具有分离效率高、回收率高的优势,其与质谱的联用提高了整体蛋白质的鉴定灵敏度和覆盖度。非变性质谱(native MS)是一种在近生理条件下从完整蛋白质复合物水平上进行分析的质谱技术。CE与非变性质谱联用已被尝试用于蛋白质复合体的分离鉴定。该文引用了与CE-MS和蛋白质组学应用相关的93篇文献,综述了以上介绍的CE-MS的研究进展以及在蛋白质组学分析中的应用优势,并总结和展望了其应用前景。  相似文献   

14.
A CE method utilizing triple quadrupole electrospray (ES) MS (MS/MS) detection was developed and validated for the simultaneous measurement of nucleoside 5'-triphosphate and 5'-monophosphate anabolites of the anti-HIV (human immunodeficiency virus) didanosine (ddAMP, ddATP) and stavudine (d4TMP, d4TTP), among a pool of 14 endogenous 5'-mono-, di-, and triphosphate nucleosides. These compounds were spiked and extracted from peripheral blood mononuclear cells (PBMCs) which are the sites of HIV replication and drug action. An acetic acid/ammonia buffer (pH 10, ionic strength of 40 mM) was selected as running electrolyte, and the separation was performed by the simultaneous application of a CE voltage of +30 kV and an overimposed pressure of 28 mbar (0.4 psi). The application of pressure assistance was needed to provide stable ES conditions for successful coupling. The coupling was carried out with a modified sheath-flow interface, with one uninterrupted capillary (80 cmx 50 microm id; 192 microm od) in a dimension that fits into the ESI needle to get a stable ion spray. Some CE-MS parameters such as overimposed pressure, sheath-liquid composition, sheath-liquid and sheath-gas flow rates, ES voltage, and the CE capillary position were optimized in order to obtain an optimal sensitivity. The use of perfluorinated alcohols and acids in the coaxial sheath-liquid make-up (2,2,2-trifluoroethanol + 0.2 mM tridecafluoroheptanoic acid) appeared to provide the best MS sensitivity and improve the stability of spray. The linearity of the CE-MS and CE-MS/MS methods was checked under these conditions. Validation parameters such as accuracy, intraday and interday precision, and LOQs were determined in CE-MS/MS mode. Finally, the quantitation of d4T-TP and ddA-TP was validated in this CE-MS/MS system.  相似文献   

15.
The effect of the electrospray ionization (ESI) needle voltage on the electroosmotic flow (EOF) in capillary electrophoresis (CE)-mass spectrometry (MS) was investigated. The radial electric field that penetrates across the CE capillary wall imposed by the ESI needle voltage modifies the typical EOF. This effect was investigated for buffers commonly used in CE-MS. Variations as high as ±30% were observed.  相似文献   

16.
The application of capillary electrophoresis-mass spectrometry (CE-MS) to the analysis of compounds of concern to the aquaculture industry is reported. Two different approaches to coupling the CE column to an IonSpray atmospheric pressure ionization (API) interface, viz., a liquid-junction and a coaxial arrangement, are describe and compared with regard to ruggedness, ease of use, sensitivity and electrophoretic performance. The different injection modes used in three commercial capillary electrophoresis systems were also evaluated for their applicability to CE-MS. The use of CE-MS for the analysis of a variety of classes of antibiotics used in the fish aquaculture industry, such as the sulfonamides and their potentiators (e.g., trimethoprim), is demonstrated and was used to confirm the presence of these components in shellfish extracts at the low ppm level. CE-MS was also applied to the analysis of marine toxins such as saxitoxin and its analogues which are associated with paralytic shellfish poisoning, and also the toxins responsible for amnesic and diarrheic shellfish poisoning. Tandem mass spectrometry (MS-MS) was used to provide structural information on these analytes, and the ability to distinguish isomeric compounds based on their different migration and fragmentation characteristics using CE-MS-MS is demonstrated.  相似文献   

17.
魏波  马遥  田文哲  赵新颖  屈锋 《色谱》2021,39(6):559-566
该文为2020年毛细管电泳(capillary electrophoresis,CE)技术年度回顾.归纳总结了以"capillary electro-phoresis-mass spectrometry"或"capillary isoelectric focusing"或"micellar electrokinetic...  相似文献   

18.
To simplify capillary electrophoresis-mass spectrometry (CE-MS) operation, a background electrolyte (BGE) containing a polymer additive is introduced that allows the analysis of peptides and protein mixtures in underivatized fused-silica capillaries without any pretreatment, thereby increasing throughput. The most important characteristic of these polymer additives is that they do not significantly suppress the signals of the proteins and peptides under electrospray ionization, thereby allowing them to be used as an additive to common BGEs that are used for CE-MS analysis of peptide and protein mixtures. In addition, because the fused-silica capillary inner wall is continuously coated with the polymer additive, migration irreproducibility, due to the degradation of the capillary inner wall coating, under CE-MS is minimized. High sensitivity of detection, migration reproducibility, and ease of fabrication allow CE-MS analyses that require long analysis time, such as (CE-MS/MS)n, to be performed with ease. The utility of this background electrolyte has been demonstrated for the analysis of complex protein digests and intact proteins.  相似文献   

19.
The use of CE coupled with MS (CE-MS) has evolved as a useful tool to analyze charged species in small sample volumes. Because of its sensitivity, versatility and ease of implementation, the ESI interface is currently the method of choice to hyphenate CE to MS. An alternative can be the atmospheric pressure photoionization (APPI) source, however, numerous parameters must be optimized for its coupling to CE. After evaluation of the sheath liquid composition and the CE capillary outlet position, an experimental design methodology was assessed for optimizing other ionization source parameters, such as sheath liquid flow rate, drying gas flow rate and temperature, nebulizing gas pressure, vaporizer temperature, and capillary voltage. For this purpose, a fractional factorial design (FFD) was selected as a screening procedure to identify factors which significantly influence sensitivity and efficiency. A face-centered central composite design (CCD) was then used to predict and optimize sensitivity, taking into account the most relevant variables. Sensitivity was finally evaluated with the optimized conditions and height-to-noise ratios (H/N) around 10 were achieved for an injection of 200 ng/mL of each analyte.  相似文献   

20.
Capillary electrophoresis (CE) mass spectrometry (MS), with its ability to separate compounds present in extremely small volume samples rapidly, with high separation efficiency, and with compound identification capability based on molecular weight, is an extremely valuable analytical technique for the analysis of complex biological mixtures. The highest sensitivities and separation efficiencies are usually achieved by using narrow capillaries (5-50 micro m i.d.) and by using sheathless CE-to-MS interfaces. The difficulties in CE-to-MS interfacing and the limited loadability of these narrow columns, however, have prevented CE-MS from becoming a widely used analytical technique. To remedy these limitations, several CE-MS interfacing techniques have recently been introduced. While electrospray ionization is the most commonly used ionization technique for interfacing CE-to-MS, matrix assisted laser desorption ionization has also been used, using both on-line and off-line techniques. Moreover, the high concentration detection limit of CE has been addressed by development of several sample concentration and sample focusing methods. In addition, a wide variety of techniques such as capillary zone electrophoresis, capillary isoelectric focusing, and on-column transient isotachophoresis have now been interfaced to MS. These advances have resulted in a rapid increase in the use of CE-MS in the analysis of complex biological mixtures. CE-MS has now been successfully applied to the analysis of a wide variety of compounds including amino acids, protein digests, protein mixtures, single cells, oligonucleotides, and various small molecules relevant to the pharmaceutical industry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号