首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The potential of the manganese-enhanced MRI (MEI) technique in labeling the intact neuronal circuitry of rat spinal cord was examined. Experiments were conducted on normal and injured cords at 9.4-T magnetic field strength using an implantable rf coil. The contrast agent manganese (Mn) was locally delivered within the parenchyma at a dose of 25 mmol/L in 10 nL. The transport, uptake and accumulation of Mn in tissue were then followed remotely on T1-weighted images that were acquired serially from the cord. In MEIs of normal cord, Mn was observed to be transported in directions both rostral and caudal to the site of injection. In the cord that was subjected to hemisection, signal enhancement was on the contralesional side of the cord, but not at the ipsilesional side. The sensitivity and specificity of the MEI technique in labeling the neurons that are functional were also validated with a traditional track-tracing method using biotinylated dextran amine.  相似文献   

2.
In vivo diffusion characteristics of rat spinal cord.   总被引:2,自引:0,他引:2  
Complete apparent diffusion tensor (ADTs) of spinal cord was measured in vivo in nine rats at 2.0 T. Two rotationally invariant parameters, the trace, which is a measure of the mean diffusivity, and the lattice index (LI), which reflects the degree of orientation coherence of tissue, have been estimated from the ADT. The mean white matter (WM) trace value (3.05 +/- 0.26 mm2/sec) was found to be substantially higher than the gray matter (GM) trace (2.36 +/- 0.39 mm2/sec), in contrast with the published results on fixed, excised cord. Statistically significant anisotropic diffusion was observed in both WM and GM, with greater anisotropy in the WM (LI = 0.67 +/- 0.06) than in the GM (LI = 0.51 +/- 0.05).  相似文献   

3.
In this study, we explore the effect of the lack of myelin on the diffusion characteristics and diffusion anisotropy obtained from high b-value q-space diffusion-weighted MRI (q-space DWI) in excised rat spinal cords. Twenty-one-day-old myelin-deficient (md) mutant (N=6) and control rats (N=6) were used in this study. The MRI protocol included multi-slice T(1), T(2), proton density (PD) MR images and high b-value q-space diffusion MRI measured perpendicular and parallel to the fibers of the spine. q-Space displacement and probability maps, in both directions, as well as displacement anisotropy maps, were computed from the diffusion data. At the end of the MRI protocol, representative spinal cords from both groups were subjected to electron microscopy (EM). The md spinal cords show different gray/white matter contrast in the T(1), T(2) and PD MR images as compared with controls. In addition, the mean displacement extracted from the high b-value q-space diffusion data was found to be dramatically higher in the white matter (WM) of the md spinal cords than the controls when diffusion was measured perpendicular and parallel to the fibers of the spine. However, interestingly, at the diffusion time used in the present study, the difference in the WM displacement anisotropies of the two groups was not found to be statistically significant. Myelin was found to have a pronounced effect on the diffusion characteristics of water in WM but less so on the diffusion anisotropy observed at the diffusion time used in the present study.  相似文献   

4.
Robust voxelwise analysis using tract-based spatial statistics (TBSS) together with permutation statistical method is standardly used in analyzing diffusion tensor imaging (DTI) of brain. A similar analytical method could be useful when studying DTI of cervical spinal cord.Based on anatomical data of sixty-four healthy volunteers, white (WM) and gray matter (GM) masks were created and subsequently registered into DTI space. Using TBSS, two skeleton types were created (single line and dilated for WM as well as GM). From anatomical data, percentage rates of overlap were calculated for all skeletons in relation to WM and GM masks.Voxelwise analysis of fractional anisotropy values depending on age and sex was conducted. Correlation of fraction anisotropy values with age of subjects was also evaluated. The two WM skeleton types showed a high overlap rate with WM masks (~94%); GM skeletons showed lower rates (56% and 42%, respectively, for single line and dilated). WM and GM areas where fraction anisotropy values differ between sexes were identified (p < .05). Furthermore, using voxelwise analysis such WM voxels were identified where fraction anisotropy values differ depending on age (p < .05) and in these voxels linear dependence of fraction anisotropy and age (r = −0.57, p < .001) was confirmed by regression analysis. This dependence was not proven when using WM anatomical masks (r = −0.21, p = .10).The analytical approach presented shown to be useful for group analysis of DTI data for cervical spinal cord.  相似文献   

5.
The signal-to-noise ratio (SNR) performance and practicality issues of a four-element phased-array coil and an implantable coil system were compared for rat spinal cord magnetic resonance imaging (MRI) at 7 T. MRI scans of the rat spinal cord at T10 were acquired from eight rats over a 3 week period using both coil systems, with and without laminectomy. The results demonstrate that both the phased array and the implantable coil systems are feasible options for rat spinal cord imaging at 7 T, with both systems providing adequate SNR for 100-mum spatial resolution at reasonable imaging times. The implantable coils provided significantly higher SNR, as compared to the phased array (average SNR gain of 5.3x between the laminectomy groups and 2.5x between the nonlaminectomy groups). The implantable coil system should be used if maximal SNR is critical, whereas the phased array is a good choice for its ease of use and lesser invasiveness.  相似文献   

6.
In vivo diffusion tensor imaging of rat spinal cord at 7 T   总被引:3,自引:0,他引:3  
In vivo diffusion tensor imaging of normal rat spinal cord was performed using a multi-segmented, blipped EPI sequence at 7 T field strength. At high diffusion weighting, the signal exhibited a non-monoexponential decay that was fitted to a biexponential function, associated with the fast and slow components of diffusion in the cord tissue, using a nonlinear regression analysis along with a constrained optimization procedure. From the measured tensors, the eigenvalues and the maps of invariant scalar measures (fractional anisotropy, relative anisotropy, volume ratio, and trace) were calculated and analyzed statistically. The results were combined to quantitatively characterize the anisotropic properties of the fast and slow diffusions in white- and gray matter of live spinal cords.  相似文献   

7.
In vivo diffusion tensor imaging (DTI) of rat cervical and thoracic spinal cord was performed using a three-element phased array coil at 7 T. The magnetic field was shimmed over the spinal cord in real time using an in-house developed automatic algorithm. Echo planar imaging (EPI)-based diffusion-weighted images (DWIs) were acquired with 21 gradient encoding directions. The DWIs were tensor encoded, and diffusion tensor metrics, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ0) and transverse diffusivity (λ) were determined for both white matter (WM) and gray matter (GM). The results on six normal rats indicated no significant differences in the diffusion tensor metrics between thoracic and cervical regions. However, the DTI-derived metrics in cervical spinal cord from our study are somewhat different from the published results in rats. The possible reasons for these differences are suggested.  相似文献   

8.
Diffusion in the extracellular and intracellular spaces (ECS and ICS, respectively) was evaluated in excised spinal cords, before and after cell swelling induced by glutamate, by high b-value q-space diffusion MR of specific markers and water. The signal decays of deuterated tetramethylammonium (TMA-d(12)) chloride, an exogenous marker of the ECS, and N-acetyl aspartate (NAA), an endogenous marker of the ICS, were found to be non-mono-exponential at all diffusion times. The signal decays of these markers were found to depend on the diffusion time and the cell swelling induced by the glutamate. It was found, for example, that the mean displacements of the apparent fast and slow diffusion components of TMA-d(12) are 7.21 +/- 0.11 and 1.16 +/- 0.05 microm, respectively at a diffusion time of 496 ms. After exposure of the spinal cords to 10 mM of glutamate, these values decreased to 6.62 +/- 0.13 and 1.01 +/- 0.05 microm, respectively. The mean displacement of NAA, however, showed a less pronounced opposite trend and increased after cell swelling induced by exposure to glutamate. q-Space diffusion MR of water was found to be sensitive to exposure to glutamate, and q-space diffusion MRI showed that a more pronounced decrease in the apparent diffusion coefficient and the mean displacement of water is observed in the gray matter (GM) of the spinal cord. All these changes demonstrate that diffusion MR is indeed sensitive to structural changes caused by cell swelling induced by glutamate. Multiparametric high b-value q-space diffusion MR is useful for obtaining microstructural information in neuronal tissues.  相似文献   

9.
Functional MRI of motor and sensory activation in the human spinal cord   总被引:6,自引:0,他引:6  
MR imaging of the cervical spinal cord was carried out on volunteers during alternated rest and either motor or sensory stimulation of one hand, in order to detect image intensity changes arising concomitant to neuronal activity. We employed both spin-echo and gradient-echo echo-planar imaging, on the right and left hands, with both symmetric and asymmetric temporal patterns of rest and stimulation. Intensity changes correlated with the time course of stimulation were consistently detected, and the magnitude of the intensity changes depended on the duration of stimulation. The activated regions in the spinal cord extended along a column on the side of the body being stimulated and included localized regions on the contralateral side, in agreement with the neural anatomy.  相似文献   

10.
Patterns of neuronal activity in the spinal cord using functional magnetic resonance imaging during noxious (48 degrees C) and innocuous (40 degrees C) thermal stimulation of the rat forepaw were examined. The patterns of functional activity elicited by thermal stimuli were compared in alpha-chloralose- and halothane-anesthetized rats. Although the locations of active pixels were similar during both types of stimulation, the mean percentage signal change was higher during noxious stimulation in both anesthetic groups. Ipsilateral dorsal horn activity was evident during both noxious and innocuous stimulation in all animals. The greatest consistency of ipsilateral dorsal horn activity occurred at the C3 to C5 spinal cord segments in all groups. Consistent contralateral dorsal horn activity appeared in segments C6 to C8 in all groups. C-fos immunohistochemical staining confirmed the presence of neural activity in the spinal cords of all animals.  相似文献   

11.
In vivo echo-planar imaging of rat spinal cord   总被引:1,自引:0,他引:1  
An integrated approach to echo-planar imaging of rat spinal cord in vivo with a small field of view (FOV) is presented. This protocol is based on a multishot interleaved echo-planar imaging (EPI) sequence and includes: 1) use of an inductively coupled implantable coil for improved signal-to-noise ratio (SNR); 2) three-dimensional (3D) automatic shimming of the magnetic field over the spinal cord; and 3) post-acquisition data processing using a multireference scan for minimizing image artifacts. Some of the practical issues in implementing this protocol are discussed. This imaging protocol will be useful in characterizing the spinal cord pathology using techniques that are otherwise time-consuming, such as diffusion tensor imaging.  相似文献   

12.
We compared the sensitivity of single and triple dose Gd-DTPA magnetic resonance imaging (MRI) in detecting enhancing lesions in the spinal cord (SC) from 15 patients with multiple sclerosis (MS). The patients were examined monthly on four occasions. We detected two enhancing lesions in two of 15 (13%) patients when a single dose of Gd-DTPA was used. No additional lesions were detected when a triple dose of Gd-DTPA was used. These results 1) confirm that enhanced spinal cord imaging does not significantly increase the detection of active lesions in MS, 2) they do not support the general application of triple dose Gd-DTPA when examining the SC but 3) suggest that further studies taking into account SC symptoms are necessary.  相似文献   

13.
Serial in vivo dynamic contrast enhanced (DCE) MRI studies were performed on spinal cord injured rats on post-injury Days 0, 10, 20 and 30 to determine the distribution of gadopentetate-dimeglumine (Gd) concentration in injured cord tissue. A two-compartment pharmacokinetic model was fitted to the time course of the concentration data at the epicenter of injury for each post-injury day. From these fits, the rates of the Gd transport between plasma and injured cord tissue were determined as a measure of blood-spinal cord barrier (BSCB) permeability. The results indicated that Gd transport rates decrease steadily with a concomitant improvement in motor functions of the rats with post-injury time. Specifically, the rates of Gd accumulation in injured SC tissue and its clearance correlated with the neurobehavioral scores with correlation coefficients of rho = -0.96 and -0.79, respectively, suggesting a significant link between the neurobehavioral function and the restoration of BSCB integrity as a result of the ongoing repair and recovery processes within the injured cords.  相似文献   

14.
15.
Contrast changes observed in functional magnetic resonance imaging in the human spinal cord were investigated with both motor and sensory tasks over a range of echo times. Data were acquired using a single-shot fast spin-echo sequence at 1.5 Tesla. Data were analyzed with two different correlation thresholds and the effects of altering the order of repeated experiments was also investigated. Plots of the fractional signal change as a function of echo time yielded linear functions with slopes corresponding to relaxation rate changes of -0.30 sec(-1) with sensory stimulation and approximately -0.50 sec(-1) with a motor task. However, the fractional signal change extrapolated to an echo time of zero was significantly greater than zero in each case and was roughly 2.5%. This suggests that in addition to the BOLD effect there is a baseline signal change which occurs concomitant to neuronal activation in the spinal cord.  相似文献   

16.
Diffusion tensor imaging (DTI) of in-vivo human brain provides insights into white matter anatomical connectivity, but little is known about measurement difference biases and reliability of data obtained with last generation high field scanners (> 3 T) as function of MRI acquisition and analyses variables. Here we assess the impact of acquisition (voxel size: 1.8 × 1.8 × 1.8, 2 × 2 × 2 and 2.5 × 2.5 × 2.5 mm3, b-value: 700, 1000 and 1300 s/mm2) and analysis variables (within-session averaging and co-registration methods) on biases and test-retest reproducibility of some common tensor derived quantities like fractional anisotropy (FA), mean diffusivity (MD), axial and radial diffusivity in a group of healthy subjects at 4 T in three regions: arcuate fasciculus, corpus callosum and cingulum. Averaging effects are also evaluated on a full-brain voxel based approach. The main results are: i) group FA and MD reproducibility errors across scan sessions are on average double of those found in within-session repetitions (≈ 1.3 %), regardless of acquisition protocol and region; ii) within-session averaging of two DTI acquisitions does not improve reproducibility of any of the quantities across sessions at the group level, regardless of acquisition protocol; iii) increasing voxel size biased MD, axial and radial diffusivities to higher values and FA to lower values; iv) increasing b-value biased all quantities to lower values, axial diffusivity showing the strongest effects; v) the two co-registration methods evaluated gave similar bias and reproducibility results. Altogether these results show that reproducibility of FA and MD is comparable to that found at lower fields, not significantly dependent on pre-processing and acquisition protocol manipulations, but that the specific choice of acquisition parameters can significantly bias the group measures of FA, MD, axial and radial diffusivities.  相似文献   

17.
A conventional spin-echo NMR imaging pulse sequence was used to obtain high-resolution images of excised normal rat spinal cord at 7 and 14 T. It was observed that the large pulsed-field gradients necessary for high-resolution imaging caused a diffusion weighting that dominated the image contrast and that could be used to infer microscopic structural organization beyond that defined by the resolution of the image matrix (i.e., fiber orientation could be assigned based on diffusion anisotropy). Anisotropic diffusion coefficients were therefore measured using apparent diffusion tensor (ADT) imaging to assess more accurately fiber orientations in the spinal cord; structural anisotropy information is portrayed in the six unique images of the complete ADT. To reduce the dimensionality of the data, a trace image was generated using a separate color scale for each of the three diagonal element images of the ADT. This new image retains much of the invariance of the trace to the relative orientations of laboratory and sample axes (inherent to a greyscale trace image) but provides, by the use of color, contrast reflecting diffusion anisotropy. The colored trace image yields a pseudo-three-dimensional view of the rat spinal cord, from which it is possible to deduce fiber orientations.  相似文献   

18.
Functional magnetic resonance imaging (fMRI) is a non-invasive neuroimaging tool that indirectly identifies areas of neural activity in the brain and more recently has been applied to the adult spinal cord (spinal fMRI). Spinal fMRI could clearly benefit pediatric populations as well. The purpose of this work was to characterize the response observed with spinal fMRI in the brainstem and cervical (C) spinal cord of awake, healthy children during thermal stimulation (17°C and 27°C) applied to the right hand. Functional MRI detected neuronal activity in the expected region of the spinal cord (C6 and C7) as well as in the brainstem and thalamus. The observed magnitudes of signal change of the responses to 17°C and 27°C were similar; however, the spatial distribution of active pixels was greater during 17°C stimulation. The results of this study indicate that fMRI can be used to assess activity in the spinal cords of children, with good sensitivity and reliability.  相似文献   

19.
We have numerically evaluated the current-current correlations for three-band models of the CuO planes in high-T(c) superconductors at hole doping x = 1/8. The results show no evidence for the orbital current patterns proposed by Varma. If such patterns exist, the associated energy is estimated to be smaller than 5 meV per link even if [formula: see text]. Assuming that the three-band models are adequate, quantum critical fluctuations of such patterns hence cannot be responsible for phenomena occurring at significantly higher energies, such as superconductivity or the anomalous properties of the strange metal phase.  相似文献   

20.
PurposeLonger latency of postural response in multiple sclerosis (MS) may be linked to imbalance and increased likelihood of falls. It may be caused by the compromised microstructural integrity in the spinal cord, as evidenced by slowed somatosensory conduction in the spinal cord. Thus, the purpose of this study is to investigate the correlation between latency of postural responses and microstructural integrity of the cervical spinal cord, the region particularly related to the disease severity in MS, using diffusion tensor imaging (DTI) metrics.MethodsSeventeen persons with MS with mild-to-moderate disease severity were enrolled in this study. Postural response latencies of each patient were measured using electromyography of the tibialis anterior muscle (TA) and gastrocnemius muscle (GN) in response to surface perturbations. Cervical spinal cord DTI images were obtained from each patient. DTI mean, radial, axial diffusivity, and fractional anisotropy (FA) were measured between segments C4 and C6. Correlations of DTI metrics with postural response latencies, expanded disability status scale (EDSS) scores, and 25-foot walk (T25FW) were assessed using the Spearman's rank correlation coefficient at α = 0.05.ResultsLower FA was significantly correlated with longer latencies measured on right TA in response to forward postural perturbations (r = −0.51, p = .04). DTI metrics showed no significant correlations with EDSS scores (r = −0.06–0.09, p = .73–0.95) or T25FW (r = −0.1–0.14, p = .6–0.94). DTI metrics showed no significant differences between subjects with and without spinal cord lesions (p = .2–0.7).ConclusionsOur results showed a significant correlation between lower FA in the cervical spinal cord and longer latencies measured on right TA in response to forward postural perturbations in persons with MS, suggesting that impaired cervical spinal cord microstructure assessed by DTI may be associated with the delayed postural responses.  相似文献   