首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The applicability of open-tubular trapping columns for on-line extraction–capillary GC analysis is evaluated. The extraction step involves sorption of the analytes from water into the stationary phase of an open-tubular column, removal of the water by purging the trap with nitrogen, and desorption of the analytes with an organic solvent. The effect of swelling of the stationary phase with organic solvents on the retention power of the trap is studied. When using pentane or hexane as swelling agent breakthrough volumes of at least 10 ml can easily be obtained for non-polar compounds. For a number of medium polarity compounds breakthrough volumes of 5 ml can be achieved when chloroform is used as the swelling agent. The required drying time is less than 1 minute. Quantitative desorption requires only 75 μl of organic solvent. Solvent elimination prior to transfer to the GC column is carried out using a PTV injector and a multidimensional GC system. The system is applied for the analyses of river water, urine, and serum samples.  相似文献   

2.
Pyle SM  Sovocool GW  Riddick LA 《Talanta》2006,69(2):494-499
A new technique to analyze aqueous samples for nanograms per liter levels of volatile and semivolatile compounds using microextraction and thermal desorption into a gas chromatograph/ion trap mass spectrometer (GC/MS) is described. This method is inherently sensitive (50 mL of aqueous sample is extracted prior to each desorption), uses no solvents, and detects volatiles and semivolatiles in the same analysis. Aqueous standards and environmental samples are pumped through a length of porous-layer open-tubular capillary column, which is then thermally desorbed onto a 30 m × 0.25 mm i.d. analytical column interfaced to an ion trap mass spectrometer for subsequent separation and detection. Sharp chromatographic peaks and reproducible retention times (RT) were observed. Replicate injections of surrogates (n = 6) averaged 32.6% R.S.D. Analysis of domestic tap water detected 55 analytes, some at the low-nanograms per liter level, and detected 3 halogenated ethenes, not previously reported in drinking water. Analysis of an aqueous sample from a municipal ground water source detected the presence of numerous semivolatile compounds at trace-levels.  相似文献   

3.
The feasibility of using ethyl acetate for the desorption of trace pollutants from a liquid chromatographic precolumn on-line into a diphenyltetramethyldisilazane-deactivated retention gap and, subsequently analysis by means of capillary gas chromatography has been demonstrated. First 5% of methanol are added to the water sample to prevent sorption of analytes onto parts of the preconcentration system. About 1 ml of this aqueous sample is injected onto a precolumn containing a polymeric stationary phase, using water–methanol (95:5, v/v) for transport and clean-up. The precolumn is desorbed with ethyl acetate and a fraction of 75 μl is injected on-line into the retention gap; separation is then achieved on a capillary CP Sil 19 column. No breakthrough of the test compounds was observed in the preconcentration step. The recovery was quantitative and the response obtained with flame ionization detection was linear in the range 0.1–100 ng/ml. The effect of varying the sorption flow rate on the recovery was studied. The system was applied to the analysis of river water.  相似文献   

4.
A new chiral stationary phase (CSP) was prepared by reacting MDL 63,246 (Hepta-Tyr), a glycopeptide antibiotic belonging to the teicoplanin family, with 5-μm diol-silica particles. The CSP mixed with 5-μm amino silica particles (3:1) was packed into 75-μm fused-silica capillaries for only 6.6 cm and used for electrochromatographic experiments analyzing several hydroxy acid enantiomers. A reversed electroosmotic flow carried both analytes and mobile phase towards the anode in a short time (1–3 min), being baseline resolved all the studied analytes. In order to achieve the fastest enantiomeric resolution of the studied hydroxy acids, the effect of several experimental parameters such as mobile phase composition (organic modifier type and concentration, pH of the buffer and ionic strength), capillary temperature and applied voltage on enantioresolution factor, retention time, enantioselectivity were evaluated. The packed capillary column allowed the separation of mandelic acid enantiomers in less than 72 s with resolution factor Rs=2.18 applying a voltage of 30 kV and eluting with a mobile phase composed by 50 mM ammonium acetate (pH 6)–water–acetonitrile (1:4:5, v/v). The CSP was also tested in the capillary liquid chromatography mode resolving all the studied enantiomers applying 12 bar pressure to the mobile phase [50 mM ammonium acetate (pH 6)–water–methanol–acetonitrile, 1:4:2:3, v/v)], however, relatively long analysis times were observed (12–20 min).  相似文献   

5.
A multibed on-line sorption trap is used to preconcentrate organic vapors from air samples and inject the analytes into a GC separation column. Injection plug widths depend on the boiling point for the lipophilic compounds and on the polarity and boiling point for the polar compounds. Injection plug widths are sufficiently small (0.7-0.8 s) as to allow the direct injection of the most volatile compounds into the GC column without the need for a second focusing device. The presence of water in the samples has an effect on the retention of polar compounds by the trap. However, this effect is reproducible for a fixed water content and so can be overcome by using calibration standards under the same conditions of humidity as the samples. The thermal decomposition of many volatile organic compounds in an on-line sorption trap during the GC analysis of air samples is examined. The results show that degradation of unstable compounds is governed by the amount of heat transferred to the compounds during desorption (i.e., applied temperature and pulse duration). The use of an on-line trap results in the immediate transfer of desorbed compounds to the analytical column, which can reduce the formation of artifacts.  相似文献   

6.
A fully automated at-line solid-phase extraction-gas chromatography procedure has been developed for the analysis of aqueous samples using the PrepStation. The sample extract is transferred from the sample preparation module to the gas chromatograph via an autosampler vial. With flame-ionization detection, limits of determination (S/N=10) of 0.05–0.13 μg/l were obtained for the analysis of HPLC-grade water when modifying the PrepStation by: (i) increasing the sample volume to 50 ml, (ii) increasing the injection volume up to 50 μl, and (iii) decreasing the desorption volume to 300 μl. The HP autosampler had to be modified to enable the automated “at-once” on-column injection of up to 50 μl of sample extract. The amount of packing material in the original cartridge had to be reduced to effect the decrease of the desorption volume. The total set-up did not require any further optimization after having set up the method once. The analytical characteristics of the organonitrogen and organophosphorus test analytes, i.e. recoveries (typically 75–105%), repeatability (2–8%) and linearity (0.09–3.0 μg/l) were satisfactory. The potential of the system was demonstrated by determining triazines and organophosphorus pesticides in river Rhine water at the 0.6 μg/l level using flame-ionization and mass-selective detection. No practical problems were observed during the analysis of more than 100 river water samples.  相似文献   

7.
Supercritical fluid extraction was coupled on-line with reversed-phase high-performance liquid chromatography (HPLC). An open-tubular column with a 95% methyl-5% phenyl stationary phase was utilized as an interface between the two systems. This phase allowed for good analyte focusing onto the packed analytical column and exhibited low reactivity. Due to the non-polar nature of this phase there was a low tendency for analytes to be prematurely rinsed off the interface by condensed modifier. Using this approach, it was possible to transfer the extracted analytes quantitatively to the HPLC column in the presence of as much as 10% (v/v) methanol. By placing a 10 m guard column at the head of the interface, the same could be accomplished with ethanol as the modifier: allowing the extraction to be conducted entirely with non-toxic fluids. The method also allowed the use of very practical extraction parameters in terms of amount extracted, extraction flow-rate, extraction vessel volume, and extraction time.  相似文献   

8.
Summary An open-tubular trap with a very thick film was studied for “full on-line” headspace capillary gas chromatography, and was used as an enrichment trap for headspace sampling. The preparation of the open-tubular column with up to an 80 μm thick film, by combining both static and dynamic coating, is described in detail. The break-through volume for the open-tubular trap of different film thickness, as the loading capacity for HS sampling, does not increase linearly in proportion to the film thickness. A study of the difference between a packed adsorbent trap and an open-tubular trap shows that HS capillary GC with open-tubular trap loses less of the retention capacity, has better resolution ability and higher recovery. By independently and rapidly heating the open-tubular trap, the GC peaks may have higher resolution. Examples of successful analyses, by the opentubular trap with “full on-line” HS capillary GC, include trace aromatic hydrocarbon (1 ppm-100 ppm) in polybutadiene-styrene rubber and trace alcohol and acrylic esters (10 ppm–1000 ppm) in polyacrylate hydrous emulsion.  相似文献   

9.
An analytical methodology for nifedipine quantitation in plasma by on-line solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) is described. The SPE cartridges contain C2 and the analytes nifedipine and nitrendipine (internal standard) are separated on a C18 column with a mobile phase consisting of acetonitrile–13 mM phosphate buffer pH 7 (65:35, v/v) followed by UV detection at 338 nm. Validation of the method demonstrated good recoveries (>90%), sensitivity (limit of quantification, 2 ng/ml), based on a 500 μl sample volume, accuracy and precision (<5.5% in concentrations greater than the limit of quantitation). This methodology has been used for bioequivalence studies.  相似文献   

10.
A novel chiral stationary phase (CSP) of Zr-based metal-organic framework, l -Cys-PCN-224, was prepared by one-pot method and applied for the enantioseparation by capillary electrochromatography. The CSP was characterized by X-ray diffraction, thermogravimetric analysis, X-ray photoelectron spectroscopy, Fourier-transform infrared spectra, nitrogen adsorption/desorption, circular dichroism spectrum, zeta-potential, and so on. The results revealed that the CSP had good crystallinity, high specific surface area (2580 m2/g), and good thermal stability. Meanwhile, the cross-section of l -Cys-PCN-224-bonded open-tubular (OT) column was observed by a scanning electron microscope, which proved the successful bonding of l -Cys-PCN-224 particles to the inner wall. Relative standard deviations of the column efficiencies were 3.87%–9.14%, and not obviously changed after 200 runs, which indicated that l -Cys-PCN-224-bonded OT column had the better stability and reproducibility. Excellent chiral separation performance was verified with nine kinds of natural amino acids including acidic, neutral, and basic as the analytes. All amino acids studied achieved good separation with the resolution of 1.38–13.9 and selector factor of 1.11–3.71. These results demonstrated that the CSP had an excellent potential in the chiral separation field.  相似文献   

11.
A flow injection procedure for the separation and pre-concentration of inorganic arsenic based on the complexation with ammonium diethyl dithiophosphate (DDTP) and sorption on a C-18 bonded silica gel minicolumn is proposed. During the sample injection by a time-based fashion, the As3+-DDTP complex is stripped from the solution and retained in the column. Arsenic(V) and other ions that do not form complexes are discarded. After reduction to the trivalent state by using potassium iodide plus ascorbic acid, total arsenic is determined by electrothermal atomic absorption spectrometry (ETAAS). Arsenic(V) concentration can be calculated by difference. After processing 6 ml sample volume, the As3+-DDTP complexes were eluted directly into the autosampler cup (120 μl). Ethanol was used for column rinsing. Influence of pH, reagent concentration, pre-concentration and elution time and column size were investigated. When 30 μl of eluate plus 10 μl of 0.1% (w/v) Pd(NO3)2 were dispensed into the graphite tube, analytical curve in the 0.3–3 μg As l−1 range was obtained (r=0.9991). The accuracy was checked for arsenic determination in a certified water, spiked tap water and synthetic mixtures of arsenite and arsenate. Good recoveries (97–108%) of spiked samples were found. Results are precise (RSD 7.5 and 6% for 0.5 and 2.5 μg l−1, n=10) and in agreement with the certified value of reference material at 95% confidence level.  相似文献   

12.
A drying cartridge was used and optimized for the in-line elimination of water from the desorption eluent in on-line solid phase extraction–gas chromatography (SPE–GC). The cartridge is essentially a small stainless-steel precolumn packed with a drying agent which can be regenerated by simultaneous heating and purging with a moisture-free gas. The drying cartridge was mounted on an additional valve instead of between the SPE–GC transfer valve and the on-column injector to enable regeneration of the cartridge during the GC run and, thus, to increase sample throughput. Three drying agents were tested, viz. sodium sulfate, silica, and molecular sieves. Although molecular sieves have the highest capacity, silica was preferred because of practical considerations. Large-volume injections were performed through the in-line drying cartridge using a mixture of 23 microcontaminants ranging widely in polarity and volatility. Four solvents were tested. With pentane and hexane, the more polar analytes were retained by the drying cartridge. Ethyl acetate and methyl acetate gave much better (and closely similar) recoveries for all analytes. Because water elimination on the silica cartridge proved to be less critical than with ethyl acetate, this solvent was finally selected. The entire SPE–drying cartridge–GC set-up was combined with mass spectrometric (MS) detection for the determination of a mixture of micropollutants in real-life water samples. With 10-ml tap water samples spiked at the 0.5 μg/l level, for the majority of the test compounds the analyte recoveries generally were 60–106%, and (full-scan) detection limits typically were 0.01–0.03 μg/l. Some very polar analytes such as, e.g. dimethoate, were (partially) sorbed onto the silica packing of the drying cartridge.  相似文献   

13.
Graphene oxide(GO) has attracted extensive attention due to its unique properties and potential applications.Here,we report the investigation of GO nanosheets as a stationary phase for capillary gas chromatographic(GC) separations.The GO column,fabricated by a new one-step coating approach,showed average McReynolds constants of 308,suggesting the medium polar nature of the GC stationary phase.The GO stationary phase achieves good separation for analytes of different types with good peak shapes,especially for H-bonding analytes,such as alcohols and amines.The different retention behaviors of GO stationary phase from the conventional stationary phase may originate from its multiple interactions with analytes,involving H-bonding,dipole-dipole,π-π stacking and dispersive interactions.Moreover,GO column showed good separation reproducibility with relative standard deviation(RSD%) less than 0.24%(n = 5) on retention times of analytes.  相似文献   

14.
Enhancing the specific surface area of stationary phase is important in chromatographic science, especially in open-tubular column in which the coating only exists on the inner surface. In this work, a porous layer open-tubular (PLOT) column with stationary phase of styrene and itaconic acid-copolymerized polymer was developed. Thermal-initiated polymerization method with strategies like controlling the ratio of reaction reagents to solvents and reaction time, confinement by the narrow inner diameter of capillary were used for preparing the stationary phase with uniform structure and relatively thick layer. Due to the high separation efficiency and capacity, the PLOT column was used for capillary electrochromatography (CEC) separation of multiple groups of analytes like alkylbenzenes, phenyl amines, phenols, vanillins, and sulfonamides with theoretical plates (N) up to 1,54,845 N/m. In addition, due to high permeability of the CEC column and large electroosmotic flow mobility generated by abundant carboxyl groups in the coating material, the PLOT-CEC column was successfully coupled with mass spectrometry (MS) through a sheath flow interface. The developed PLOT-CEC-MS method was used for the analysis of antiseptics like parabens and herbicides like pyridines.  相似文献   

15.
Non-suppressed and suppressed ion chromatography in combination with atmospheric pressure ionization mass spectrometry are compared with special respect to sensitivity for the analysis of low-molecular-mass anions. Iodate, bromate, bromide, sulfate, thiosulfate and bromide could be separated by non-suppressed ion chromatography using a low-capacity anion-exchange column and ammonium citrate as mobile phase. Absolute detection limits between 0.4 and 0.7 ng could be achieved; employing a column requiring a flow-rate of 1 ml/min for optimum performance, splitting was necessary so that only 120 μl/min entered the interface of the mass spectrometer resulting in detection limits between 0.03 and 0.06 mg/l. The same stationary phase (packed into a narrow-bore column which allowed operation without splitting) was suitable for the separation of oxyhalides in the suppressed mode with detection limits of 0.5 μg/l (50 pg) with sodium carbonate as eluent. The method was applied to the analysis of drinking water for oxyhalides. The sample pretreatment for the removal of matrix anions (sulfate, chloride and hydrogencarbonate) is described.  相似文献   

16.
Column technology for capillary electrochromatography   总被引:4,自引:0,他引:4  
Column technologies for capillary electrochromatography (CEC) are reviewed. To achieve high efficiency, the inner diameters of open-tubular and packed columns should be less than 25 and 200 μm, respectively. To obtain acceptable separation speed under typical CEC conditions (e.g. 30 kV, 1 mm s−1 electroosmotic flow velocity, and 2–4×10−8 m2 V−1 s−1 electroosmotic mobility) the column lengths for open-tubular and packed columns should be less than 120 and 60 cm, respectively. Capillary CEC columns are generally classified into three types: packed, open-tubular, and continuous-bed or monolithic. The various column preparation procedures and the advantages and disadvantages of each column type are discussed in detail.  相似文献   

17.
Trace enrichment for the GC analysis of a series of chlorinated pesticides and polychlorinated biphenyls (PCBs) in aqueous samples has been achieved through a simple on-line technique involving sorption on an LC micro-precolumn followed by direct elution into a gas chromatograph with hexane. A 5-m retention gap coupled to the capillary GC column served as the recipient of a relatively large sample volume (ca. 100 μl) introduced into the GC. Partially concurrent solvent evaporation during sample introduction allowed a large sample capacity. Recoveries of more than 95% were observed for the majority of the compounds studied. Using 1.0 ml aqueous samples, detection limits of less than 1 ppt were found. The applicability of the developed method was demonstrated for a river water sample.  相似文献   

18.
A method is described for determining methylphosphonic acid, ethyl methylphosphonic acid and isopropyl methylphosphonic acid, which are hydrolysis products of the nerve agents VX (S-2-diisopropylaminoethyl O-ethyl methylphosphonothiolate) and GB (sarin, isopropylmethyl phosphonofluoridate). The analytes are extracted from 50 ml groundwater using a solid-phase extraction column packed with 500 mg of silica with a bonded quaternary amine phase, and are eluted and derivatized with methanolic trimethylphenylammonium hydroxide. Separation and quantitation are achieved using a capillary column gas chromatograph equipped with a flame photometric detector operated in its phosphorus-selective mode. Two independent statistically-unbiased procedures were employed to determine the detection limits, which ranged between 3 and 9 μg/l, for the three analytes.  相似文献   

19.
A modification of a packed GC injector to a capillary injector is presented using a simple device which is connected to the GC column by an adsorption-free connector. It permits injections of large sample volumes up to 500 μl hexane solutions on normal 0.3 mm i.d. capillary columns. No special requirements for the stationary phase are necessary. Involatile residues remain inside the device which can be exchanged easily. High performance of separation and quantification is achieved.  相似文献   

20.
Reversed-phase liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was employed to analyze brevetoxin compounds associated with naturally occurring red tide blooms collected from Sarasota Bay, FL, USA. The LC-ESI-MS method utilizes a C18 microbore column with a mobile phase consisting of methanol-water (85:15, v/v), a flow-rate of 8 μl/min and a post-column split ratio of 3:1 (UV-absorbance detector-mass spectrometer). Three known brevetoxins Btx-2, Btx-1 and Btx-3 were detected at 60 μg/l, 10 μg/l and 5.7 μg/l levels, respectively, in the natrual red tide bloom samples. This distribution differed quantitatively from that found in red tide culture extract samples. Btx-9 was not detected either in natural red tide bloom extracts or in red tide culture extracts, possibly due to the instability of this compound. An unknown component with a molecular mass of 941 found in the natural bloom extract was postulated to have the structure of a reduced form (hydrogenation of two double bonds in the alkyl side chain) of Btx-5.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号