首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Atmospheric polycyclic aromatic hydrocarbons are ubiquitous environmental pollutants, which may be present both in the gaseous phase and adsorbed onto the surface of particles. Denuders are sampling devices which have been effectively employed in such partitioning applications. Here we describe and characterise a novel miniature denuder consisting of two multi-channel silicone rubber traps (each 178 mm long, 6 mm o.d. containing 22 silicone tubes), separated by a quartz fibre filter for particle phase collection. The denuder only requires a small portable personal sampling pump to provide sampling flow rates of ∼0.5 L min−1. Theoretical considerations indicated that the air flow through the denuder was expected to be laminar, and the linear velocity arising from longitudinal diffusion was found to be negligible. The calculated particle transmission efficiency through the denuder was found to be essentially 100% for particles > 50 nm, whilst the experimental overall efficiency, as determined by CPC and SMPS measurements, was 92 ± 4%. The size resolved transmission efficiency was <60% for particles below 20 nm and 100% for particles larger than 200 nm. Losses could have been due to diffusion and electrostatic effects. Semi-volatile gaseous analytes are pre-concentrated in the silicone of the trap and may be thermally desorbed using a commercially available desorber, allowing for total transfer and detection of the collected analytes by GC–MS. This enhances detection limits and allows for lower sampling flow rates and shorter sampling times, which are advantageous for studies requiring high temporal resolution.  相似文献   

2.
We provide an extensive review of the common methodologies employed in the analysis of airborne polycyclic aromatic hydrocarbons (PAHs). The review focuses on gas-chromatography-based approaches, in the light of their universal application with excellent separation, resolution, and sensitivity.We first describe collection methods for airborne PAHs in the gas and particle phases. We then evaluate the efficiency of extraction techniques employed for separating target PAHs from sampling media, using conventional solvent-based and emerging thermal-desorption approaches.We also describe commonly employed analytical methods with respect to their applicability to PAHs in gas and particle phases, collected from diverse environmental settings. As an essential part of basic quality assurance, we examine each method with special emphasis on key parameters (e.g., limit of detection and reproducibility).Finally, we address the likely directions of methodological developments, their limitations, and the future prospects for PAH analysis.  相似文献   

3.
4.
Müller J  Rohbock E 《Talanta》1980,27(8):673-675
A method for measuring polycyclic aromatic hydrocarbons (PAHs) in ambient air is described. The particulate matter is collected on fibre-glass filters. The loaded filters are placed in tetrahydrofuran and the PAHs dissolved with the aid of ultrasonics and analysed by high-performance liquid chromatography on a reversed-phase column with a methanol-water mixture as mobile phase. The PAHs are detected by use of a UV-detector and the 254-nm mercury emission line. The method is rapid and adequate for measuring about 15 PAH-components in ambient air.  相似文献   

5.
In repetitive determinations of polycyclic aromatic hydrocarbons in combustion products the use of incompletely separated Chromatographic fractions is often an advantage favouring rapid work. Such fractions may be submitted to an approximate quantitative analysis by using tables of absorption peak heights measured from a base-line drawn between theminima on each side of the peak. Convenient tables for this method are provided in this paper.  相似文献   

6.
The size distribution of polycyclic aromatic hydrocarbons (PAH) was determined for airborne particles from a large city with high vehicular traffic. The analytical method was optimised and validated using NIST standard reference material (SRM 1649a Urban Dust). The 16 priority PAH listed in the US-EPA were Soxhlet-extracted from filtered particulate matter and then fractionated using on-column chromatography. The aromatic fraction was quantified by gas chromatography-mass spectrometry. Real samples of particles collected in Seville (Spain) were analysed using the validated method. Values for the total concentration of PAH in the air, as well as the concentrations of each PAH in six particle-size ranges were obtained. Values of the PAH in TSP, PM10, PM2.5 and PM1 were assessed.  相似文献   

7.
Paolo Bruno  Maria Tutino 《Talanta》2007,72(4):1357-1361
The determination of polycyclic aromatic hydrocarbons (PAHs) contained in samples of particulate matter (PM), collected with low volume pumps, were carried out with an high sensitivity method that comes from several revisions of a previous method. The present work describes how, by using programmable temperature vaporization (PTV) and a mass selective detector with inert ionic source for the GC-MS analysis and the modifications of microwave-assisted extraction (MAE), the sensitivity of the method can be increased.The PAHs chosen for testing the method are: benzo[a]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), benzo[a]pyrene (BaP), indeno[1,2,3-cd]pyrene (Ip) and dibenzo[a,h]anthracene (DbA). They, in fact, belong to that group of substances that are the most harmful for human health for their carcinogenicity.PAHs recoveries for spiked standard solutions at different concentrations were between 95 and 100% with relative standard deviation ranging from 1 to 3%. The revised method was validated using a 1649a urban dust standard reference material (SRM). The results obtained were in good agreement with certified values. The high sensitivity of the method allows to carry out analyses using only a half of the sampled filter (usually 47 mm diameter membranes). In this way, the other half can be used for the characterization of the other components of PM (heavy metals, organic carbon, ions, etc). The last step has been constituted by application of the optimized method on real samples collected in two cities located in Southern Italy (Bari and Taranto).  相似文献   

8.
Samples of Ottawa drinking water, collected in January and February 1978 were analysed by Gas Chromatography/Mass Spectrometry (GC/MS) for fifty polycyclic aromatic hydrocarbons (PAH) and five oxygenated polycyclic aromatic hydrocarbons (O-PAH), following extraction of the organic species using Amberlite XAD-2 macroreticular resin. In the January sample, thirty PAHs, ranging in concentration from 0.05 to 14 ng/L with a mean value of 3.8 ng/L and a total weight of 114 ng/L and four O-PAHs, ranging in concentration from 0.10 to 1.8 ng/L with a mean value of 0.91 ng/L and a total weight of 3.7 ng/L, were detected. In the February sample, thirty-six PAHs, ranging in concentration from 0.05 to 8.1 ng/L with a mean value of 1.4 ng/L and a total weight of 50.4 ng/L and five O-PAHs, ranging in concentration from 0.20 to 2.4 ng/L with a mean value of 1.0 ng/L and a total weight of 5.2 ng/L, were detected. Twenty-eight PAHs and four O-pahs were common to the two samples. The use of Amberlite XAD-2 macroreticular resin to extract PAHs from drinking water is shown to be effective, although the recovery of individual PAHs from artificially loaded XAD-2 resin varied from 57 to 100%.  相似文献   

9.
《Comptes Rendus Chimie》2016,19(6):754-765
Rosemary (Rosmarinus officinalis L.) is a perennial herb with an intensive aromatic flavor. Its most important chemical constituents are essential oils (e.g., 1,8-cineole and camphor) and antioxidants (e.g., carnosic acid and rosmarinic acid). The common methods to extract the essential oil of rosemary are steam or hydro distillation. The aim of this work is to investigate the residual antioxidants after hydro distillation, especially rosmarinic acid and carnosic acid. For this purpose, the hydro distillation water residues were analyzed by HPLC-UV. Moreover, the influence of the extraction duration on the concentration of the antioxidants was investigated. Also, the residual amount of these compounds in the leaves was examined. The total antioxidant activity of the extracts and of the pure compounds was determined by DPPH assays. It is shown that after 2.5 h of hydro distillation the amount of rosmarinic acid and the antioxidant activity in the water residue reaches a maximum value. In addition, the yield and the quality of the essential oil were investigated to draw a comparison between steam and hydro distillations of Moroccan rosemary leaves.  相似文献   

10.
Summary Elution strengths of 11 common HPLC solvents on a polymeric C18 phase were compared using a marker set of polycyclic aromatic hydrocarbons. Naphthalene, pyrene, benzo[ghi]perylene, and three larger naphthologues of 8, 10, and 12 rings (constituting a naphthalene zigzag series) were chosen because they span the solvent strength range up to and including the strongest solvents, tetrahydrofuran (THF) and chlorobenzene. Four pairs of similarly shaped isomers were used to probe solvent selectivity. With the exception of THF, HPLC solvent strength correlated with observed red shifts of fluorescence band maxima in each solvent. For THF, the pure solvent and blended mixtures behaved quite differently.  相似文献   

11.
Zhu L  Takahashi Y  Amagai T  Matsushita H 《Talanta》1997,45(1):113-118
A method for the quantitation of polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air by high-performance liquid chromatography (HPLC) with a spectrofluorometric detection and programmed excitation and emission wavelength pairs is proposed. The mobile phase is a linear gradient of methanol-water. The relative standard deviations (n = 5) are in the range 0.38-1.7% at concentration levels of 0.69-11.40 ng ml(-1). The determination limits (S N = 10 ) are 0.5-15.9 pg. The proposed method was successfully applied to quantitate 12 PAHs in gas phase and particulates in indoor and outdoor air. The recoveries of PAHs from gas phase and particulates were 95.7-117.5 and 94.8-112.4%, respectively. This highly sensitive automatic HPLC analysis for PAHs both in gas phase and particulates can be applied to indoor and outdoor survey.  相似文献   

12.
多环芳烃水中溶解度的理论计算   总被引:1,自引:0,他引:1  
建立了计算多环芳烃水中溶解度的数学表达式,用量子化学方法计算了7个多环芳烃的水中溶解度,计算结果与实验测定结果相符合.多环芳烃处于水体内体系状态能量愈高,其溶解度愈小,多环芳烃中的碳氢基团越多,溶解度越小.此时体系中的溶质呈单分子态,而不是聚集态.  相似文献   

13.
Particle-associated polycyclic aromatic hydrocarbons (PAHs) collected in urban air of Beijing were studied using a gas chromatograph mass spectrometer (GC/MS). The average concentration of particle-associated PAHs measured in this work was in the range from 28.53 to 362.15 ng/m3, which suggested a serious pollution level of PAHs in Beijing. The results also showed that the concentration of PAHs in the winter was distinctly higher than that in summer and spring. Benzo(a)pyrene (BaP) and benzo(a)pyrene-equivalent carcinogenic power (BaPE) were adopted to evaluate the PAHs pollution state at the sampling site. Through some diagnostic ratios, it can be concluded that traffic exhaust, especially vehicles with diesel engines, and domestic coal-burning heaters might have a prominent contribution to the PAHs concentration.  相似文献   

14.
A low-pressure gas chromatography-ion trap mass spectrometry (LPGC-ITMS) method was investigated to shorten the analysis time for 18 US Environmental Protection Agency priority listed polycyclic aromatic hydrocarbons (PAHs). Their elution was optimised with a short, wide-bore column coupled to a deactivated capillary at the inlet end and with a long, conventional column to compare their analytical performance. The analytical figures of merit under optimal LPGC-ITMS conditions were determined with respect to chromatographic separation, S/N ratio, limit of detection and precision. The peak width at half height of 1.5s matched the ITMS duty cycle. Up to 16 PAHs in the molecular weight (MW) range of 128-278 Da could be separated in a very short time, i.e. less than 13 min using LPGC-ITMS, whereas with conventional GC-MS, it took approximately 40 min. However, LPGC-ITMS has a limited loss of separation power compared to that of conventional GC-MS due to the occurrence of three critical pairs for high-MW PAHs. For a practical evaluation, the LPGC-ITMS approach was applied to the determination of PAHs in gas and aerosol phase samples collected in the ambient air of Hasselt, Belgium.  相似文献   

15.
Summary Since 1980 a number of Standard Reference Materials (SRM's) have been issued by the National Bureau of Standards (NBS) to assist in validating measurements for the determination of polycyclic aromatic hydrocarbons (PAH) and other polycyclic aromatic compounds (PAC). These SRM's are certified for selected PAC and range in analytical difficulty from calibration solutions to complex natural matrix materials, such as air and diesel particulate matter, shale oil, and crude oil. In the past year three new SRM's have been introduced: (1) SRM 1647a Priority Pollutant PAH in Acetonitrile, (2) SRM 1491 Aromatic Hydrocarbons in Hexane/Toluene, and SRM 1597 Complex Mixture of PAH from Coal Tar. The SRM's available from NBS for use in the determination of PAC are described and the concentrations of PAC determined in the natural matrix SRM's are summarized and compared. The primary analytical techniques used for the measurement of PAC in these SRM's were gas chromatography, liquid chromatography, and gas chromatography/mass spectrometry.
Standardreferenzmaterialien für die Bestimmung von polycyclischen aromatischen Kohlenwasserstoffen
  相似文献   

16.
This work describes the applicability of magnetic ionic liquids (MILs) in the analytical determination of a group of heavy polycyclic aromatic hydrocarbons. Three different MILs, namely, benzyltrioctylammonium bromotrichloroferrate (III) (MIL A), methoxybenzyltrioctylammonium bromotrichloroferrate (III) (MIL B), and 1,12-di(3-benzylbenzimidazolium) dodecane bis[(trifluoromethyl)sulfonyl)]imide bromotrichloroferrate (III) (MIL C), were designed to exhibit hydrophobic properties, and their performance examined in a microextraction method for hydrophobic analytes. The magnet-assisted approach with these MILs was performed in combination with high performance liquid chromatography and fluorescence detection. The study of the extraction performance showed that MIL A was the most suitable solvent for the extraction of polycyclic aromatic hydrocarbons and under optimum conditions the fast extraction step required ∼20 μL of MIL A for 10 mL of aqueous sample, 24 mmol L−1 NaOH, high ionic strength content of NaCl (25% (w/v)), 500 μL of acetone as dispersive solvent, and 5 min of vortex. The desorption step required the aid of an external magnetic field with a strong NdFeB magnet (the separation requires few seconds), two back-extraction steps for polycyclic aromatic hydrocarbons retained in the MIL droplet with n-hexane, evaporation and reconstitution with acetonitrile. The overall method presented limits of detection down to 5 ng L−1, relative recoveries ranging from 91.5 to 119%, and inter-day reproducibility values (expressed as relative standard derivation) lower than 16.4% for a spiked level of 0.4 μg L−1 (n = 9). The method was also applied for the analysis of real samples, including tap water, wastewater, and tea infusion.  相似文献   

17.
建立了气相色谱-三重四极杆串联质谱检测环境空气中多环芳烃的方法,并利用同位素稀释法对多环芳烃进行了测定。将该方法应用于华南地区某大型石化企业周边环境空气中多环芳烃的检测,并与气相色谱-质谱方法进行了对比。结果表明,该方法的仪器检出限(0.01~0.15 μg/L)和定量限(0.03~1.5 μg/L)均优于气相色谱-质谱法(0.1~0.8 μg/L和0.3~3.5 μg/L),并有更好的灵敏度与选择性。当利用气相色谱-质谱作为检测手段时,回收率指示物氘代菲和进样内标六甲基苯均受到了杂质的严重干扰,影响了定量结果的准确性,而三重四极杆串联质谱很好地解决了这些问题。实际样品分析时,标准曲线中16种多环芳烃相对响应因子的相对标准偏差为2.60%~15.6%,氘代化合物的回收率为55.2%~82.3%,空白加标样品的回收率为98.9%~111%,平行样品的相对标准偏差为6.50%~18.4%,采样空白含量范围为未检出~44.3 pg/m3,实验室空白含量范围为未检出~36.5 pg/m3。上述研究表明,分析环境空气中的多环芳烃时,气相色谱-三重四极杆串联质谱方法值得推广。  相似文献   

18.
Summary In the gas chromatographic determination of polycyclic aromatic hydrocarbons (PAHs), internal standards (ISs) are frequently used in order to correct for losses and fluctuating experimental parameters. In this study eight monofluorinated PAHs (F-PAHs) are used to this end. Analysis was by means of large-volume injection-gas chromatography with mass spectrometric detection (LVI-GC-MS). Relevant experimental results and performance data are presented, and it is demonstrated that the use of at least one F-PAH as IS improves the repeatability dramatically. As a brief application, F-PAHs were used as ISs for the trace-level determination of PAHs in soil, after extraction by means of pressurized liquid extraction (PLE) and liquid partitioning (LP). The suitability of the approach was demonstrated with naphthalene and pyrene as test compounds.  相似文献   

19.
Polycyclic aromatic hydrocarbons (PAHs) are widely distributed in the environment and are often implicated as potential carcinogens. It is generally believed that the carcinogenic potential of polycyclic aromatic hydrocarbons is linked to the formation of ultimate carcinogens generated by metabolic biotransformations. In this paper we propose a methodology that consists of using both quantum chemical properties and structural features of the reaction sites to predict PAH metabolism. Two essential questions have been answered: at which sites will the reaction take place and does the transformation consist of epoxidation or hydroxylation? This methodology has been successfully implemented into an expert system, META, for the evaluation of metabolic transformations of new chemicals. Received: 3 April 1998 / Accepted: 6 July 1998 / Published online: 7 October 1998  相似文献   

20.
A novel partitioning collection device comprising a glass cartridge packed with poly(dimethylsiloxane)‐coated macroporous silica particles was developed for the precise quantification of polycyclic aromatic hydrocarbons in air. The analyte collection and elution performances achieved using different amounts of poly(dimethylsiloxane) coating were quantitatively evaluated. The sample retention power increased with increasing the coating, and more than 250 L of air could be collected without analyte breakthrough at a sampling temperature of 35°C. During the air collection, the moisture in the air was not retained on the particles due to the hydrophobic surface of the sorbent. A complete and rapid elution of the collected analytes from the device was accomplished by the passage of only 10 mL of acetone with ultrasonication for 1 min. The proposed method was successfully applied for the determination of airborne polycyclic aromatic hydrocarbons in tunnel air.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号