共查询到20条相似文献,搜索用时 15 毫秒
1.
Fotini N. Bazoti Evangelos Gikas Anthony Tsarbopoulos 《Biomedical chromatography : BMC》2010,24(5):506-515
Oleuropein (OE) is the cardinal bioactive compound derived from Olea europaea and possesses numerous beneficial properties for human health. However, despite the plethora of analytical methods that have studied the biological fate of olive oil‐derived bioactive compounds, no validated methodology has been published to date for the simultaneous determination of OE, along with all its major metabolites. In this study, a liquid chromatography‐electrospray ionization‐tandem mass spectrometry (LC‐ESI MS/MS) method has been developed and validated for the quantification of OE, simultaneously with its main metabolites hydroxytyrosol, 2‐(3,4‐dihydroxyphenyl)acetic acid, 4‐(2‐hydroxyethyl)‐2‐methoxy‐phenol or homovanillyl alcohol, 2‐(4‐hydroxy‐3‐methoxyphenyl)acetic acid or homovanillic acid, and elenolic acid in rat plasma matrix. Samples were analyzed by LC‐ESI MS/MS prior to and after enzymatic treatment. A solid‐phase extraction step with high mean recovery for all compounds was performed as sample pretreatment. Calibration curves were linear for all bioactive compounds over the range studied, while the method exhibited good accuracy, intra‐ and inter‐day precision. The limit of detection was in the picogram range (per milliliterof plasma) for HT and OE and in the nanogram range (per milliliter of plasma) for the other analytes, and the method was simple and rapid. The developed methodology was successfully applied for the simultaneous quantification of OE and its aforementioned metabolites in rat plasma samples, thus demonstrating its suitability for pharmacokinetics, as well as bioavailability and metabolism studies. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
2.
A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5 > 166.1 for itopride and m/z 342.3 > 111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2 = 0.9999) over the studied range (0.5-1000 ng mL−1) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers. 相似文献
3.
Development and validation of a liquid chromatography with tandem mass spectrometry method for the quantification of vitisin B in rat plasma and urine 下载免费PDF全文
Joeng Kee Lee Jung Bae Park Tae‐Hwe Heo Choongho Lee Soo Kyung Bae 《Journal of separation science》2015,38(11):1872-1880
A new, rapid, and sensitive liquid chromatography with tandem mass spectrometry method was developed for the determination of vitisin B and validated in rat plasma and urine using carbamazepine as an internal standard. The plasma (0.05 mL) or urine (0.2 mL) samples were extracted by liquid–liquid extraction with ethyl acetate and separated on an Eclipse Plus C18 column (100 × 4.6 mm, 3.5 μm) with a mobile phase consisting of acetonitrile and 0.1% formic acid water (60:40, v/v) at a flow rate of 0.7 mL/min. Detection and quantification were performed by mass spectrometry in selected reaction‐monitoring mode with positive electrospray ionization. The calibration curves were recovered over the concentration ranges of 10?5000 ng/mL (correlation coefficients, r≥0.9833) in plasma and 5?2500 ng/mL (r≥0.9977) in urine, respectively. All validation data, including the specificity, precision, accuracy, recovery, and stability, conformed to the acceptance requirements. No matrix effects were observed. The developed method was successfully applied to pharmacokinetic studies of vitisin B following intravenous administration of 0.5 and 1 mg/kg and intraperitoneal injection of 5, 10, and 25 mg/kg to rats. This is the first report on the pharmacokinetic properties of vitisin B. The results provide a meaningful basis to evaluate preclinical or clinical applications of vitisin B. 相似文献
4.
Peiyuan Xia 《Journal of separation science》2016,39(15):2890-2895
A sensitive and specific liquid chromatography with tandem mass spectrometry method was firstly developed for the measurement of isomangiferin in rat plasma. Chloramphenicol was selected as the internal standard. Sample preparation was carried out through a simple one‐step protein precipitation procedure with methanol. Negative electrospray ionization was performed using multiple reaction monitoring mode with transitions of m/z 421.1/301.1 for isomangiferin, and 321.1/151.9 for chloramphenicol. The calibration curve was linear over the range of 0.1–600 ng/mL, with a lower limit of quantification at 0.1 ng/mL. The intra‐ and interday precisions (relative standard deviation) were no more than 8.2% and accuracies (relative error) were within the range of –8.4 to 2.2%. The recovery, matrix effect and stability under different conditions were all proved acceptable. The validated method has been successfully applied to a preclinical pharmacokinetic study of isomangiferin in rats for the first time. 相似文献
5.
Xu DH Lou HG Yuan H Jiang B Zhou Q Zhang ZM Ruan ZR 《Biomedical chromatography : BMC》2008,22(4):433-440
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone. 相似文献
6.
Oxana Yu. Kravtsova Sergey A. Paramonov Natalya I. Vasilevich Denis N. Kazyulkin Ekaterina Vlasova Michael Engsig 《Biomedical chromatography : BMC》2013,27(12):1609-1614
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
7.
Laurito TL Santagada V Caliendo G Oliveira CH Barrientos-Astigarraga RE De Nucci G 《Journal of mass spectrometry : JMS》2002,37(4):434-441
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption. 相似文献
8.
Nirogi R Bhyrapuneni G Kandikere V Mudigonda K Ajjala D Mukkanti K 《Biomedical chromatography : BMC》2008,22(10):1043-1055
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma. 相似文献
9.
Mudigonda K Jukanti R Apte SS Kishan V Maurya S Kandikere V Nirogi R 《Biomedical chromatography : BMC》2008,22(1):20-27
A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of zidovudine in rat plasma. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 268/127 for zidovudine and m/z 230/112 for the internal standard. The method exhibited a linear dynamic range of 5-500 ng/mL for zidovudine in rat plasma. The lower limit of quantification was 5 ng/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 1.5 min for each sample made it possible to analyze more than 400 plasma samples per day. The validated method was applied for pharmacokinetic studies of the novel drug delivery systems of zidovudine in rats. 相似文献
10.
Armaghan Shafaei Kevin Croft Jonathan Hodgson Mary C. Boyce 《Journal of separation science》2019,42(18):2909-2921
A diet rich in polyphenolic compounds has recognized health benefits, and as such is routinely monitored as part of dietary intervention studies. A method for the simultaneous determination of 36 phenolic compounds, including phenolic acids and flavonoids, using liquid chromatography and tandem mass spectrometry is described here. The target analytes were quantified based on their specific mass spectral fragments using a selected reaction monitoring approach. A C18 column with embedded aromatic functionality ensured separation of all phenolic compounds studied which included several pairs of isomers. Sample preparation involved the use of β‐glucuronidase to release the phenolic compounds from their conjugated forms. The intra‐day and inter‐day precision and accuracy was less than 7% for all phenolic compounds studied. Recoveries, where plasma was spiked with three different concentrations of the analytes, ranged from 95–115%. The limits of detection and quantification were 0.23–3.89 and 1.15–7.79 nM, respectively. The method was successfully applied to real samples and the range reported for each phenolic compound, with the exception of hydroferulic acid, nordihydroguaiaretic acid, methylgallate, and m‐coumaric acid, was at least an order of magnitude higher than the limit of quantification for the method. 相似文献
11.
Simultaneous quantification of leukotrienes and hydroxyeicosatetraenoic acids in cell culture medium using liquid chromatography/tandem mass spectrometry 下载免费PDF全文
Leukotrienes (LTs) and hydroxyeicosatetraenoic acids (HETEs) are important bioactive lipid mediators that participate in various pathophysiological processes. To advance understanding of the mechanisms that regulate these mediators in physiological and pathological processes, an analytical method using liquid chromatography/tandem mass spectrometry for the simultaneous quantification of LTB4, LTC4, LTD4, LTE4, 5‐HETE, 8‐HETE, 12‐HETE and 15‐HETE in cell culture media was developed. A Supel?‐Select HLB solid‐phase extraction cartridge was used for sample preparation. The compounds were separated on a C18 column using gradient elution with acetonitrile–water–formic acid (20:80:0.1, v/v/v) and acetonitrile–formic acid (100:0.1, v/v). The calibration curves of LTB4, LTD4, LTE4 and HETEs were linear in the range of 0.025–10 ng/mL, and the calibration curve of LTC4 was linear in the range of 0.25–10 ng/mL. Validation assessment showed that the method was highly reliable with good accuracy and precision. The stability of LTs and HETEs was also investigated. Using the developed method, we measured LTs and HETEs in the culture supernatant of the human mast cell line HMC‐1. The present method could facilitate investigations of the mechanisms that regulate the production, release and signaling of LTs and HETEs. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
12.
Quaternary ammonium drugs (QADs) are anticholinergic agents some of which are known to have been abused or misused in equine sports. A recent review of literature shows that the screening methods reported thus far for QADs mainly cover singly-charged QADs. Doubly-charged QADs are extremely polar substances which are difficult to be extracted and poorly retained on reversed-phase columns. It would be ideal if a comprehensive method can be developed which can detect both singly- and doubly-charged QADs. This paper describes an efficient liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous detection and confirmation of 38 singly- and doubly-charged QADs at sub-parts-per-billion (ppb) to low-ppb levels in equine urine after solid-phase extraction. 相似文献
13.
Determination of thymopentin in beagle dog blood by liquid chromatography with tandem mass spectrometry and its application to a preclinical pharmacokinetic study 下载免费PDF全文
Meiyun Shi Yan Yang Xiaotong Zhou Lanlan Cai Chunxue Fang Can Wang Heping Sun Yantong Sun Yin Gao Jingkai Gu J. Paul Fawcett 《Journal of separation science》2015,38(8):1351-1357
The pentapeptide thymopentin (Arg‐Lys‐Asp‐Val‐Tyr, RKDVY) corresponds to amino acids 32–36 of the 49 amino acid immunomodulatory polypeptide, thymopoietin, whose biological activity is partially reproduced. Thymopentin is widely used in the clinic and represents a promising target for drug design but bioanalytical and pharmacokinetic data are limited due to its enzymatic instability. This paper reports a rapid and sensitive method based on liquid chromatography with tandem mass spectrometry for the determination of thymopentin in beagle dog blood. To inactivate peptidases and stabilize thymopentin, acetonitrile was added to blood samples immediately after collection followed by addition of stable isotope‐labeled thymopentin as internal standard and washing with dichloromethane. Chromatography was carried out on an Ascentis Express Peptide ES‐C18 column using gradient elution with methanol and aqueous 0.1% formic acid at a flow rate of 0.6 mL/min. Positive electrospray ionization mass spectrometry with selected reaction monitoring achieved linearity in the range of 1.5–800 ng/mL with good accuracy/precision and minimal matrix effects. The method was successfully applied to a pharmacokinetic study in beagle dogs after intravenous administration of 0.2 mg/kg thymopentin. 相似文献
14.
Nirogi RV Kandikere V Shrivastava W Mudigonda K Maurya S Ajjala D 《Biomedical chromatography : BMC》2007,21(11):1151-1158
A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of pramipexole in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 212/152 for pramipexole and m/z 409/228 for the IS. The method exhibited a linear dynamic range of 200-8000 pg/mL for pramipexole in human plasma. The lower limit of quantification was 200 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 3.5 min for each sample made it possible to analyze more than 200 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. 相似文献
15.
Jaivik V. Shah Daxesh P. Patel Priyanka A. Shah Mallika Sanyal Pranav S. Shrivastav 《Biomedical chromatography : BMC》2016,30(2):208-216
A simple, sensitive and reproducible ultra‐performance liquid chromatography–tandem mass spectrometry method has been developed for the simultaneous determination of atenolol, a β‐adrenergic receptor‐blocker and chlorthalidone, a monosulfonamyl diuretic in human plasma, using atenolol‐d7 and chlorthalidone‐d4 as the internal standards (ISs). Following solid‐phase extraction on Phenomenex Strata‐X cartridges using 100 μL human plasma sample, the analytes and ISs were separated on an Acquity UPLC BEH C18 (50 mm × 2.1 mm, 1.7 µm) column using a mobile phase consisting of 0.1% formic acid–acetonitrile (25:75, v/v). A tandem mass spectrometer equipped with electrospray ionization was used as a detector in the positive ionization mode for both analytes. The linear concentration range was established as 0.50–500 ng/mL for atenolol and 0.25–150 ng/mL for chlorthalidone. Extraction recoveries were within 95–103% and ion suppression/enhancement, expressed as IS‐normalized matrix factors, ranged from 0.95 to 1.06 for both the analytes. Intra‐batch and inter‐batch precision (CV) and accuracy values were 2.37–5.91 and 96.1–103.2%, respectively. Stability of analytes in plasma was evaluated under different conditions, such as bench‐top, freeze–thaw, dry and wet extract and long‐term. The developed method was superior to the existing methods for the simultaneous determination of atenolol and chlorthalidone in human plasma with respect to the sensitivity, chromatographic analysis time and plasma volume for processing. Further, it was successfully applied to support a bioequivalence study of 50 mg atenolol + 12.5 mg chlorthalidone in 28 healthy Indian subjects. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
16.
Keumhan Noh Kwang‐il Kwon Tae Cheon Jeong Wonku Kang 《Biomedical chromatography : BMC》2010,24(11):1199-1202
Sparfloxacin, a fluoroquinolone antibiotic, is used for the treatment of bacterial infection. A quantification method using mass spectrometry was developed for the determination of sparfloxacin in rat plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed‐phase C18 column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma sparfloxacin concentrations after a single oral administration of sparfloxacin in rats. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
17.
Analysis of amicarbazone and its two metabolites in grains and soybeans by liquid chromatography with tandem mass spectrometry 下载免费PDF全文
Maofeng Dong Dongxia Nie Hongxia Tang Qinxiong Rao Mingqing Qu Weimin Wang Lijun Han Weiguo Song Zheng Han 《Journal of separation science》2015,38(13):2245-2252
A sensitive, simple and reliable analytical method based on a modified quick, easy, cheap, effective, rugged, safe sample preparation and liquid chromatography with tandem mass spectrometry detection was developed for the simultaneous determination of amicarbazone and its two major metabolites desamino amicarbazone and isopropyl‐2‐hydroxy‐desamino amicarbazone residues in grains (rice, wheat, corn, buckwheat) and soybean. Several parameters, including liquid chromatography and tandem mass spectrometry conditions, extraction approaches and the adsorbents for clean‐up, which might influence the accuracy of the method, were extensively investigated. The established method was further validated by determining the linearity (R2 > 0.99), fortified recovery (79–118%), precision (1–12%) and sensitivity (limit of quantification, 5 μg/kg for amicarbazone and desamino amicarbazone, and 10 μg/kg for isopropyl‐2‐hydroxy‐desamino amicarbazone). Finally, the established method was successfully applied to determine the residues of amicarbazone and its metabolites in 49 real samples of grain and soybean. 相似文献
18.
Nirogi R Kandikere V Mudigonda K Komarneni P Aleti R Boggavarapu R 《Biomedical chromatography : BMC》2008,22(2):214-222
A sensitive high-performance liquid chromatography-positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of sitagliptin, a DPP-4 inhibitor, in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 408-235 for sitagliptin and m/z 310-148 for the internal standard. The assay exhibited a linear dynamic range of 0.1-250 ng/mL for sitagliptin in human plasma. The lower limit of quantification was 0.1 ng/mL with a relative standard deviation of less than 6%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic studies. 相似文献
19.
Limin He Kaiyong Liu Yijuan Su Jiahui Zhang Yahong Liu Zhenling Zeng Binghu Fang Guijun Zhang 《Journal of separation science》2011,34(15):1755-1762
Cyadox is a novel antimicrobial growth‐promoter of the quinoxalines. For food safety and pharmacokinetic studies, a convenient, sensitive and reproducible LC‐ESI‐MS/MS method was developed for the simultaneous determination of cyadox and its major metabolites, quinoxaline‐2‐carboxylic acid, 1,4‐bisdesoxycyadox, cyadox‐1‐monoxide and cyadox‐4‐monoxide in chicken plasma. Plasma sample was subjected to a simple deproteinisation with acetonitrile. Analysis was performed on a C18 column by detection with mass spectrometry in multiple reaction monitoring mode. A gradient elution program with 0.2% formic acid, methanol and acetonitrile was performed at a flow rate of 0.2 mL/min. The decision limits (CCαs) of five analytes in plasma ranged from 1.0 to 4.0 μg/L, and the detection capabilities (CCβs) were <10 μg/L. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The extraction recoveries of five analytes were between 87.4 and 93.9% in plasma at the spiked levels of 5 (10)–200 μg/L with the relative standard deviations <10% for each analyte. The developed method demonstrated a satisfactory applicability in real plasma samples. 相似文献
20.
Simultaneous enantioselective determination of isocarbophos and its main metabolite isocarbophos oxon in rice,soil, and water by chiral liquid chromatography and tandem mass spectrometry 总被引:2,自引:0,他引:2 下载免费PDF全文
Zhoulin Yao Mei Lin Mingfei Xu Tianyu Wang Xinliang Ping Shaohui Wu Qiang Wang Hu Zhang 《Journal of separation science》2015,38(10):1663-1672
An efficient enantioselective method for the simultaneous determination of isocarbophos and its main metabolite isocarbophos oxon in rice, soil, and water was developed using liquid chromatography with tandem mass spectrometry. The enantioseparation was performed on a Chiralpak AD‐3R column at 30°C using gradient elution. Target compounds were extracted from soil and rice using acetonitrile with omission of a clean‐up procedure, while a C18 solid‐phase extraction column was used for water samples. Quantification was achieved using matrix‐matched calibration. The overall mean recoveries for isocarbophos and isocarbophos oxon enantiomers from the five matrices were 89.7–103 and 90.1–98.7%, with relative standard deviations of 2.1–5.4 and 2.5–4.7%, respectively. Moreover, the absolute configurations of isocarbophos oxon enantiomers were determined by liquid chromatography with tandem mass spectrometry through incubation of each isocarbophos enantiomer in soil, the first eluting enantiomer being confirmed as (R)‐(?)‐isocarbophos oxon. The proposed method was applied to real soil samples and satisfactory results were obtained. 相似文献