首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, a new system for analysis using a dual comprehensive two-dimensional gas chromatography/targeted multidimensional gas chromatography (switchable GC × GC/targeted MDGC) analysis was developed. The configuration of this system not only permits the independent operation of GC, GC × GC and targeted MDGC analyses in separate analyses, but also allows the mode to be switched from GC × GC to targeted MDGC any number of times through a single analysis. By incorporating a Deans switch microfluidics transfer module prior to a cryotrapping device, the flow stream from the first dimension column can be directed to either one of two second dimension columns in a classical heart-cutting operation. Both second columns pass through the cryotrap to allow solute bands to be focused and then rapidly remobilized to the respective second columns. A short second column enables GC × GC operation, whilst a longer column is used for targeted MDGC. Validation of the system was performed using a standard mixture of compounds relevant to essential oil analysis, and then using compounds present at different abundances in lavender essential oil. Reproducibility of retention times and peak area responses demonstrated that there was negligible variation in the system over the course of multiple heart-cuts, and proved the reliable operation of the system. An application of the system to lavender oil, as a more complex sample, was carried out to affirm system feasibility, and demonstrate the ability of the system to target multiple components in the oil. The system was proposed to be useful for study of aroma-impact compounds where GC × GC can be incorporated with MDGC to permit precise identification of aroma-active compounds, where heart-cut multidimensional GC-olfactometry detection (MDGC-O) is a more appropriate technology for odour assessment.  相似文献   

2.
Three commercially available chiral capillary columns, Chirasil-Dex, BGB-176SE, and BGB-172, have been evaluated for the separation into enantiomers of the 19 chiral polychlorinated biphenyls (PCB) congeners stable at room temperature. The enantiomers of 15 chiral PCBs were, at least to some extent, separated using these beta-cyclodextrin based columns. Multidimensional techniques, such as heart-cut multi-dimensional gas chromatography (heart-cut MDGC) and comprehensive two-dimensional gas chromatography (GC x GC), were investigated for their ability to solve coelution problems with other PCBs present in commercial mixtures and real-life samples. Heart-cut MDGC improved the separation as compared to one-dimensional GC, and enantiomeric fractions of the investigated chiral PCBs could be determined free from interferences. However, limitations on the number of target compounds that can be transferred to the second column in a single run and, therefore, the time consumption, have led to the evaluation of GC x GC as an alternative for this type of analysis. With GC x GC, two column set-ups were tested, both having a chiral column as first-dimension column, and two different polar stationary phase columns in the second dimension. On using both column combinations, congeners 84, 91, 95, 132, 135, 136, 149, 174, and 176 could be determined free from coelutions with other PCBs. Results on the application of heart-cut MDGC to food samples such as milk and cheese are given, as well as the first results on the application of GC x GC to this type of samples.  相似文献   

3.
Comprehensive two-dimensional gas chromatography (GC x GC) is based on a coupling of two GC columns of different characteristics by means of a device that allows portions of the effluent from the primary column to be injected onto the second dimension column for an additional separation. The time available for the separation in the second-dimension column is very short. Thus, this separation should be very efficient. The vast majority of GC x GC practitioners use very narrow bore columns for the second dimension. While this approach is justified in principle, if peaks in the second dimension overload this column, its peak capacity is severely reduced. A series of second-dimension columns of varying internal diameters, but similar phase ratios, were used to study these effects. The results indicate that 250 microm columns often provide comparable second dimension peak widths to 100 microm columns, while at the same time being less prone to overloading, indicating that they may often be a better choice than smaller diameter columns in the second dimension of GC x GC systems.  相似文献   

4.
Two approaches are described and compared for the analysis of suspected allergens (SAs) in fragrance products, which are defined by the Scientific Committee of Cosmetics and Non-Food Products (SCCNFP). The first consists of a comprehensive two-dimensional gas chromatography (GCxGC) experiment using both a "conventional" non-polar/polar column combination and an "inverse" polar/non-polar column set. The second approach uses a targeted multidimensional gas chromatography (MDGC) system employing a Deans type pneumatic switch and a longitudinally modulated cryogenic system (LMCS). It was found that the conventional and inverse column sets complement each other well, providing identification of SAs present. Compounds well retained on the second dimension of one column set were the first to be eluted from the other. In some instances SAs co-eluting with matrix components on the second dimension for a given column set were clearly resolved on the other, although this has the disadvantage of requiring two analytical runs. Targeted MDGC with a non-polar/polar column set, successfully separated all SAs identified within a fragrance product. The instrument is set up in a similar fashion to a GCxGC system though with longer second dimension ((2)D) column, a cryogenic trap at the beginning of the second column, and a pneumatic switch coupling both columns. The data are easier to process than for a GCxGC experiment. The targeted MDGC method has the capacity to deliver far greater efficiency to targeted regions of a primary separation than a GCxGC experiment, whilst still maintaining overall run times similar to those of a conventional one-dimensional (1D) GC experiment. Cryogenic focussing at the beginning of the (2)D column delivers enhanced sensitivity, accurate (2)D retention times and narrow peak widths; these are responsible for an increased resolution obtained from the fast, relatively short ( approximately 5m) (2)D column. The two column set GCxGC analysis provided a quick and effective means to qualitatively determine the presence of six SAs in a commercially available air freshener, however all were not adequately resolved from matrix components. In contrast, quantitation was straightforward using the targeted MDGC method.  相似文献   

5.
Historically, hardware and method-related concerns have limited the use of multidimensional gas chromatography in the routine laboratory. This paper presents a new approach that offers the potential to significantly alter the manner in which multidimensional gas chromatography is conducted, based on the use of a modulated cryogenic trap which can be moved longitudinally along the column. Two columns are directly coupled, and no switching valves are used. It is demonstrated that a heartcut section can be cryofocused and zone-compressed, and then rapidly remobilized at the prevailing column oven temperature without any supplementary heating. A short second dimension column is used, giving fast second dimension analysis. This allows a large number of heartcuts to be programmed for any one analysis. The 'ultimate' manifestation of multidimensional gas chromatography is the comprehensive GC technique (GC X GC). This is now simply effected by performing very rapid heartcuts at intervals on the order of 1/5th of the peak width of primary dimension peaks, and requires that the second dimension be able to complete the analysis of each collected zone on a similar timeframe. This paper uses a semi-volatile aromatic mixture to demonstrate these selected operational modes, that can be achieved with the longitudinal modulation method. The flexibility that arises from this approach is shown by the ability to swap between selected whole-peak enhancement and comprehensive modes during the one analytical run. The increased sensitivity that follows from peak compression is a further advantage, which would be beneficial for trace analysis.  相似文献   

6.
7.
In rural parts of South Africa the organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control where traditional dwellings are sprayed on the inside with small quantities of technical DDT. Since o,p′-DDT may show enantioselective oestrogenicity and biodegradability, it is important to analyse enantiomers of o,p′-DDT and its chiral degradation product, o,p′-DDD, for both health and environmental-forensic considerations. Generally, chiral analysis is performed using heart-cut multidimensional gas chromatography (MDGC) and, more recently, comprehensive two-dimensional gas chromatography (GC × GC). We developed an off-line gas chromatographic fraction collection (heart-cut) procedure for the selective capturing of the appropriate isomers from a first apolar column, followed by reinjection and separation on a second chiral column. Only the o,p′-isomers of DDT and DDD fractions from the first dimension complex chromatogram (achiral apolar GC column separation) were selectively collected onto a polydimethylsiloxane (PDMS) multichannel open tubular silicone rubber trap by simply placing the latter device on the flame tip of an inactivated flame ionisation detector (FID). The multichannel trap containing the o,p′-heart-cuts was then thermally desorbed into a GC with time-of-flight mass spectrometry detection (GC–TOFMS) for second dimension enantioselective separation on a chiral column (β-cyclodextrin-based). By selectively capturing only the o,p′-isomers from the complex sample chromatogram, 1D separation of ultra-trace level enantiomers could be achieved on the second chiral column without matrix interference. Here, we present solventless concentration techniques for extraction of DDT from contaminated soil and air, and report enantiomeric fraction (EF) values of o,p′-DDT and o,p′-DDD obtained by a new multidimensional approach for heart-cut gas chromatographic fraction collection for off-line second dimension enantiomeric separation by 1D GC–TOFMS of selected isomers. This multidimensional method is compared to the complementary technique of comprehensive GC × GC–TOFMS using the same enantioselective column, this time as the first dimension of separation.  相似文献   

8.
Comprehensive gas chromatography is the realization of true continuous multidimensional (dual column) gas chromatography. The key requirement in the comprehensive GC experiment is that the second dimension analysis is completed in a rapid time‐frame compared to the elution of components in the first dimension, and that the two coupled dimensions represent ‘orthogonal’ analyses towards the analytes to be separated. The former normally necessitates pulsing of contiguous segments of each chromatographic band from the first to the second dimensions. The two dimensions should be in fluid communication. The comprehensive GC×GC experiment passes all the column flow from the first column to the second column, leading to no sample loss, but this also requires a suitable method for time‐ or zone‐compression of the band to be pulsed to the second column. The final pulse should be narrow, and should be delivered to the second column quickly. A simple procedure can achieve this using the cryogenic modulator that has been recently described by this group. The system uses a cryogenic trap which can be moved away from the cooled zone of the column faster than 10 ms. A fast‐acting pneumatic ram achieves this performance. The cooled column heats up to the prevailing oven temperature within 10–15 ms. Molecules as volatile as C5 alkanes or small aromatics will be fully retained by the trap within the period of modulation used for GC×GC. The technique is simple to implement and requires no special column connections. Using a gas chromatograph which allows control of external events and can acquire from a detector at 50 Hz or faster, and a timing controller for modulation, the comprehensive result can easily and effectively be achieved.  相似文献   

9.
A comprehensive two-dimensional capillary supercritical fluid chromatography method was developed. The interface consisted of a ten-port valve, a capillary trap and two fused silica restrictors. The primary column was operated in stop-flow mode: the flow in the primary column was stopped during the separation of the second dimension. The pressure of the system was controlled with a single pump. The pressure program was synchronized with the sampling: the pressure was only ramped up during the sampling time, when the primary column effluent was transferred from the first dimension to the trap, and was maintained constant during the second-dimension separation. All of the operations were automated using in-house software. The separation characteristics of the present system can be readily regulated by changing the size of the restrictors and/or the programmed pressure rate. The use of synchronized pressure programming allowed the sampling duration and/or the second-dimension separation time (and therefore, the total analysis time) to be changed without affecting the separation pattern. Widely different selectivities were attained depending on the combination of the three columns with different polarities (such as the nonpolar DB-1, the medium-polarity DB-17 and the polar DB-WAX columns) used. The present system afforded improved separation and identification capabilities for analytes in complex mixtures.  相似文献   

10.
Multidimensional gas chromatography (MDGC), and especially its latest incarnation—comprehensive two-dimensional gas chromatography (GC × GC)—have proved advantageous over and above classic one-dimensional gas chromatography (1D GC) in many areas of analysis by offering improved peak capacity, often enhanced sensitivity and, especially in the case of GC × GC, the unique feature of ‘structured’ chromatograms. This article reviews recent advances in MDGC and GC × GC in drug analysis with special focus on ecstasy, heroin and cocaine profiling. Although 1D GC is still the method of choice for drug profiling in most laboratories because of its simplicity and instrument availability, GC × GC is a tempting proposition for this purpose because of its ability to generate a higher net information content. Effluent refocusing due to the modulation (compression) process, combined with the separation on two ‘orthogonal’ columns, results in more components being well resolved and therefore being analytically and statistically useful to the profile. The spread of the components in the two-dimensional plots is strongly dependent on the extent of retention ‘orthogonality’ (i.e. the extent to which the two phases possess different or independent retention mechanisms towards sample constituents) between the two columns. The benefits of ‘information-driven’ drug profiling, where more points of reference are usually required for sample differentiation, are discussed. In addition, several limitations in application of MDGC in drug profiling, including data acquisition rate, column temperature limit, column phase orthogonality and chiral separation, are considered and discussed. Although the review focuses on the articles published in the last decade, a brief chronological preview of the profiling methods used throughout the last three decades is given.  相似文献   

11.
二维液相色谱接口的改进及其在蛋白质组学研究中的应用   总被引:1,自引:0,他引:1  
李笃信  张凌怡  李彤  杜一平  张维冰 《色谱》2010,28(2):163-167
随着蛋白质组学、本草物质组学等组学概念的提出,所需分析的样品的成分越来越复杂,因此具有强大分离能力的多维液相色谱技术受到人们越来越多的关注。二维液相色谱中第二维的分离性能和速度是整个分离系统性能的关键。基于捕集柱模式,我们采用经特殊设计的流路系统,使得双捕集柱型接口具有预分离的功能。样品从第一维流出以后被富集在捕集柱1的柱头,经过脱盐后,正冲捕集柱,捕集柱1与第二维色谱柱联用对富集的样品进行分离,增加了第二维分离效率。当捕集柱上的样品全部被洗脱到第二维色谱柱上时,捕集柱2已经完成对第一维洗脱液中样品的捕集和脱盐,此时将阀进行切换,捕集柱2与第二维色谱柱直接相连进行洗脱。循环切换捕集柱1和捕集柱2,维持较高的阀切换频率,实现了第二维色谱柱的连续洗脱。因此保证了第二维分离具有较快速度,同时具有较高的分离效率。使用35 mm长捕集柱和十通阀为接口,以弱阴离子交换(WAX)色谱为第一维分离模式,以反相(RP)色谱为第二维分离模式,构建了WAX-RP二维液相色谱系统(2D-LC system)。以小鼠血清为样品对系统进行了初步评价。色谱流出曲线出现了明显的界面现象,这是由于捕集柱流动相中含有的较多盐分流出时的背景吸收造成的。同时,由于界面两侧的流动相黏度不同产生了黏性指进(VF)现象。当第二维色谱柱长度为50 mm时,理论上可将第二维分离效能提高70%。该接口可以应用于多种二维液相色谱模式,适用于蛋白质组学和本草物质组学研究中对于复杂样品的分离分析。  相似文献   

12.
In the present work, an orthogonal two-dimensional (2D) capillary liquid chromatography (LC) method for fractionation and separation of proteins using wide range pH gradient ion exchange chromatography (IEC) in the first dimension and reversed phase (RP) in the second dimension, is demonstrated. In the first dimension a strong anion exchange (SAX) column subjected to a wide range (10.5-3.5) descending pH gradient was employed, while in the second dimension, a large pore (4,000 A) polystyrene-divinylbenzene (PS-DVB) RP analytical column was used for separation of the protein pH-fractions from the first dimension. The separation power of the off-line 2D method was demonstrated by fractionation and separation of human plasma proteins. Seventeen pH-fractions were manually collected and immediately separated in the second dimension using a column switching capillary RP-LC system. Totally, more than 200 protein peaks were observed in the RP chromatograms of the pH-fractions. On-line 2D analysis was performed for fractionation and separation of ten standard proteins. Two pH-fractions (basic and acidic) from the first dimension were trapped on PS-DVB RP trap columns prior to back-flushed elution onto the analytical RP column for fast separation of the proteins with UV/MS detection.  相似文献   

13.
Murahashi T 《The Analyst》2003,128(6):611-615
A comprehensive two-dimensional HPLC system for the separation of polycyclic aromatic hydrocarbons was developed using a pentabromobenzyl column as the first dimension and two short monolithic C18 columns as the second dimension. The primary column and two secondary columns were coupled by a 10-port 2-position valve. The effluent from the first dimension was repetitively injected into the second dimension every 12 s. Due to its resolution, this technique is a powerful tool for the separation of polycyclic aromatic hydrocarbons in a complex matrix such as environmental samples.  相似文献   

14.
Highly efficient and sophisticated separation techniques are available to analyze complex compound mixtures with superior sensitivities and selectivities often enhanced by a 2nd dimension, e.g. a separation technique or spectroscopic and spectrometric techniques. For enantioselective separations numerous chiral stationary phases (CSPs) exist to cover a broad range of chiral compounds. Despite these advances enantioselective separations can become very challenging for mixtures of stereolabile constitutional isomers, because the on-column interconversion can lead to completely overlapping peak profiles. Typically, multidimensional separation techniques, e.g. multidimensional GC (MDGC), using an achiral 1st separation dimension and transferring selected analytes to a chiral 2nd separation are the method of choice to approach such problems. However, this procedure is very time consuming and only predefined sections of peaks can be transferred by column switching to the second dimension. Here we demonstrate for stereolabile 1,2-dialkylated diaziridines a technique to experimentally deconvolute overlapping gas chromatographic elution profiles of constitutional isomers based on multiple-reaction-monitoring MS (MRM-MS). The here presented technique takes advantage of different fragmentation probabilities and pathways to isolate the elution profile of configurational isomers.  相似文献   

15.
Pulsed flow modulation (PFM) is based on higher flow rate time compression of the first GC column effluent, which prior to the injection into the second column is stored for a few seconds in a standard fused silica wide bore transfer line. We constructed the PFM device with two standard 1/16 in. brass compression fittings with the insertion of the two columns inside the wide bore 0.53 mm i.d. fused silica storage transfer line for the elimination of dead volumes. This simple arrangement provides a combination of flexibility in the length of the sample storage transfer line hence comprehensive two-dimensional gas chromatography (GC x GC) cycle time, inert sample path and full elimination of cooling gas consumption. A record short second column injection time of 20 ms is demonstrated. Practical injection times are the sample collection time (such as 4s) divided by the second to first column flow rate ratio (such as 20/0.7), which is typically around 150 ms. Due to the low cost of the device it can also be considered for use with non comprehensive time segmented GC x GC to remove a few accidental coelutions. PFM-GCxGC excels with high second column capacity due to the use of 0.32 mm i.d. columns with high flow rates as the second dimension GC x GC column. As a result, PFM-GCxGC can have up to two orders of magnitude higher second column sample capacity and linear dynamic range for improved reduction of adverse matrix interference effects due to column overloading.  相似文献   

16.
For a technology little over a decade old, comprehensive two-dimensional gas chromatography (GC x GC) has quickly reached the status of one of the most powerful analytical tools for volatile organic compounds. At the heart of any GC x GC system is an interface, which physically connects the primary and the secondary columns and acts to preserve the separation obtained in the first dimension (first column) while allowing additional separation in the second dimension. The paper presents a review of the technology, including fundamental principles of the technique, data processing and interpretation and a timeline of inventive contributions to interface design. In addition, applications of the technique are presented, with a more detailed discussion of selected examples.  相似文献   

17.
Two‐dimensional liquid chromatography largely increases the number of separated compounds in a single run, theoretically up to the product of the peaks separated in each dimension on the columns with different selectivities. On‐line coupling of a reversed‐phase column with an aqueous normal‐phase (hydrophilic interaction liquid chromatography) column yields orthogonal systems with high peak capacities. Fast on‐line two‐dimensional liquid chromatography needs a capillary or micro‐bore column providing low‐volume effluent fractions transferred to a short efficient second‐dimension column for separation at a high mobile phase flow rate. We prepared polymethacrylate zwitterionic monolithic micro‐columns in fused silica capillaries with structurally different dimethacrylate cross‐linkers. The columns provide dual retention mechanism (hydrophilic interaction and reversed‐phase). Setting the mobile phase composition allows adjusting the separation selectivity for various polar substance classes. Coupling on‐line an organic polymer monolithic capillary column in the first dimension with a short silica‐based monolithic column in the second dimension provides two‐dimensional liquid chromatography systems with high peak capacities. The silica monolithic C18 columns provide higher separation efficiency than the particle‐packed columns at the flow rates as high as 5 mL/min used in the second dimension. Decreasing the diameter of the silica monolithic columns allows using a higher flow rate at the maximum operation pressure and lower fraction volumes transferred from the first, hydrophilic interaction dimension, into the second, reversed‐phase mode, avoiding the mobile phase compatibility issues, improving the resolution, increasing the peak capacity, and the peak production rate.  相似文献   

18.
The present research is focussed on the evaluation of a recently developed high performance multidimensional gas chromatographic (MDGC) system employed in the fast analysis of a series of chiral compounds contained in rosemary essential oil. The heart of the MDGC system consists in a simple transfer device for the rapid sequential re-injection of analyte "heart-cuts" from the first to the second dimension. The transfer system has no temperature restrictions, presents very low dead volumes and achieves multidimensional analysis through a pressure-balance mechanism. The MDGC set-up is characterized by two GC ovens (enabling independent temperature programming) and the possibility of mass spectrometric (MS) and/or flame ionization detection (FID). Multiple-cut conventional and fast MDGC-FID methods were developed and the results obtained compared, in order to evaluate the effectiveness of the system. In this respect, the rapid method provided the same analytical result in a greatly reduced time (approximately five times less). Furthermore, quali/quantitative data reproducibilty was very good. Fast MDGC was achieved by using micro-bore (0.1mm I.D.) columns in both dimensions.  相似文献   

19.
A major challenge in metabolomics analysis is the accurate quantification of metabolites in the presence of (extremely) high abundant metabolites. Quantification of metabolites at low concentrations can be complicated by co-elution and/or peak distortion when these metabolites elute close to high abundant metabolites. To increase the separation efficiency a comprehensive two-dimensional gas chromatographic-mass spectrometric method (GC x GC-MS) was set up, in which a polar first dimension column and an apolar second dimension column were used to maximize the peak capacity. The feasibility of using wider bore, thicker film columns in the second dimension to improve the mass loadability and inertness of the analytical system was investigated. Several column combinations with varying second dimension column dimensions were compared with a setup with a narrow bore column (0.1mm I.D.) in the second dimension. With a wider bore column (0.32 mm I.D.) in the second dimension the mass loadability was improved 10-fold, and the more inert column surface of the thicker film second dimension column resulted in a more accurate (automated) quantification and improved linearity in the presence of high concentrations of matrix compounds or metabolites. These benefits amply compensated the observed decrease in peak capacity of 40% compared to the narrow bore (0.1mm I.D.) thin film second dimension column. Compared to GC-MS and conventional GC x GC-MS, better performance for quantification of metabolites for typical metabolomics samples was achieved.  相似文献   

20.
Summary A large volume injection system for preparative supercritical fluid chromatography is described. The method which is based on the solvent venting technique coupled with dilution of the sample solution consists of three steps. The first step is continuous dilution of the sample solution with liquid carbon dioxide at a controlled flow rate. The second step is solvent removal and solute trapping in a packed trap column. Combination of these two steps results in efficient solvent removal and the volume of sample which can be injected in a single injection becomes virtually unlimited. The third step is transfer and re-concentration of the solutes from the trap column on to the separation column with the pressures of both columns controlled independently; the final step is the separation. With this method, mass overloading behavior has been investigated and preparative separations performed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号