首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
One problem of matrix-assisted laser desorption ionization coupled to time-of-flight mass spectrometry is the moderate mass accuracy that typically can be obtained in routine applications, Here we report improved mass accuracy for peptides, even when low amounts and complex peptide mixtures are used. A new procedure for preparing matrix surfaces is used, and there is no need to mix the matrix with the sample or to add internal standards. Examples are shown with a mass accuracy better than 50 ppm in a peptide mixture. Peptide mapping as well as sequencing by creating “ragged ends” or “ladder sequencing” should benefit especially from the improved mass accuracy.  相似文献   

2.
Octyl‐functionalized hybrid magnetic mesoporous (Fe3O4·nSiO2·meso‐hybrid‐C8) microspheres were synthesized and applied in the isolation and pre‐concentration of low‐concentration peptides prior to direct analysis by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS). Such microspheres possess high surface area (324 m2/g), hydrophobic group (C8), relatively large pore volume (0.304 cm3/g), uniform pore diameter (~3.7 nm), and magnetic responsivity, which make them a simple and efficient kind of adsorbent for the enrichment of low‐concentration peptides. For bovine serum albumin (BSA, 15 fmol μL–1) digest, after concentration by Fe3O4·nSiO2·meso‐hybrid‐C8 microspheres, the enrichment performance was evidently better than those obtained by solvent evaporation and C8‐functionalized magnetic particles, and comparable to those obtained by commercial Anchor chip target and ZipTipC18 pipette tip. Such microspheres were further applied in the enrichment of the tryptic digests of rat cerebellum proteins and endogenous peptides of crude human serum, and more peaks with higher signal‐to‐noise (S/N) ratio were obtained than before pre‐concentration. Furthermore, the pre‐concentration reproducibility of magnetic microspheres for biological samples was good, and the limit of detection (LOD) for BSA digests by MALDI‐TOF MS was decreased by at least one order of magnitude compared with that obtained without pre‐concentration. All the above‐mentioned results indicate that the synthesized Fe3O4·nSiO2·meso‐hybrid‐C8 microspheres are promising for the enrichment of low‐concentration peptides from complex biosamples. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
Direct tandem mass spectrometric (MS/MS) analysis of small, singly charged protein ions by tandem time-of-flight mass spectrometry (TOFMS) is demonstrated for proteins up to a molecular mass of 12 kDa. The MALDI-generated singly charged precursor ions predominantly yield product ions resulting from metastable fragmentation at aspartyl and prolyl residues. Additional series of C-terminal sequence ions provide in some cases sufficient information for protein identification. The amount of sample required to obtain good quality spectra is in the high femtomolar to low picomolar range. Within this range, MALDI-MS/MS using TOF/TOF trade mark ion optics now provides the opportunity for direct protein identification and partial characterization without prior enzymatic hydrolysis.  相似文献   

4.
In-source decay (ISD) of peptides, coupled with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, has been examined to determine the influence of the matrix, the susceptibility of amino-acid residues to ISD, and the effect of extraction delay times. Out of nine di- and tri-hydroxybenzoic acids and three cinnamic derivatives tested, the most suitable matrix for ISD was 2,5-dihydroxybenzoic acid. The amine bond at Xxx-Gly and Xxx-Val residues was less susceptible than other amino-acid residues to ISD; however, the more sensitive residue(s) were not as clear. Using a peptide that gave the y(n)- and (z(n) + 2)-series product ions, it was confirmed that amide-bond cleavage (formation of the y(n)-series ions) accompanied metastable peaks, whereas metastable peaks were never observed with amine-bond cleavage [formation of the (z(n) + 2)-series ions]. Furthermore, abundant c(n)-series ions, which originate from amine-bond cleavage on the peptide backbone, were observed whenever a minimum delay time of 38 ns or continuous extraction was used to obtain spectra. These data indicate that amine-bond cleavage in ISD takes place on the ionization time scale before the energy randomization is completed.  相似文献   

5.
Tyrosinase-induced oxidation of tyrosine is known to lead to melanin by cross-linking of 5,6-dihydroxyindole (DHI) and indole-5,6-quinone intermediates. However, tyrosinase-induced cross-linking of tyrosine-containing peptides has not been reported. We observed tyrosinase-induced adducts of tyrosine-containing peptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). MALDI-TOFMS was also used to observe tyrosine adducts at various levels of oxidation derived from acid hydrolysis of the peptide adducts. The rate of tyrosinase-induced browning of lys-tyr-lys was about half of that of tyrosine. These results indicate that tyrosinase-induced browning of tyrosine-containing peptides via direct oxidation and cross-linking of the benzene ring of the tyrosine residue occurs at a significant rate and needs to be considered in melanogenesis.  相似文献   

6.
A novel method for acquisition and numerical analysis of matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectral data is described. The digitized ion current transient from each consecutive laser shot is first acquired and stored independently. Subsequently, statistical correlation parameters between all stored transients are computed. We illustrate the uses of this event-by-event analysis method for studies of sample surface heterogeneity as well as for elucidating the mechanisms of ion formation in MALDI. Other potential applications of the method are also outlined.  相似文献   

7.
Metastable decomposition of ions generated in matrix-assisted laser desorption/ionization (MALDI) mass spectrometers complicates analysis of biological samples that have labile bonds. Recently, several academic laboratories and manufacturers of commercial instruments have designed instruments that introduce a cooling gas into the ion source during the MALDI event and have shown that the resulting vibrational cooling stabilizes these labile bonds. In this study, we compared stabilization and detection of desorbed gangliosides on a commercial orthogonal time-of-flight (oTOF) instrument with results we reported previously that had been obtained on a home-built Fourier transform mass spectrometer. Decoupling of the desorption/ionization from the detection steps resulted in an opportunity for desorbing thin-layer chromatography (TLC)-separated gangliosides directly from a TLC plate without compromising mass spectral accuracy and resolution of the ganglioside analysis, thus coupling TLC and oTOF mass spectrometry. The application of a declustering potential allowed control of the matrix cluster and matrix adduct formation, and, thus, enhanced the detection of the gangliosides.  相似文献   

8.
Direct matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis of solutions of edible fats/oils yielded spectra useful for their rapid differentiation and classification. Results also reflected the individual fatty acid components and their degree of unsaturation. After dissolution in hexane, MALDI-MS analysis revealed spectra showing characteristic triacylglycerols (TAGs), the main fat/oil components, as sodium adduct ions. The Euclidean distances calculated using the mass and intensity values for 20 TAGs were used to evaluate and compare spectra. With cluster analysis, animal fats grouped together differently than vegetable oils and the individual oils grouped together by type. The ion abundances for the individual TAGs and their presumed compositions were used to approximate the overall fatty acid composition of canola, soybean, corn, olive and peanut oil, as well as lard. Using this approach the calculated fatty acid compositions and degree of unsaturation generally fell within about 4% of literature values. When the degree of saturation was compared with values calculated from the package labeling the differences were about 7%.  相似文献   

9.
Specific capture of phosphopeptides from protein digests is a critical step for identification of phosphoproteins by mass spectrometry. In this study, we report a novel phosphopeptide-capture approach based on the specific interaction of phosphopeptides with a stainless steel target modified with magnetic affinity nanoparticles. The modification which was carried out by loading the suspension of nanoparticles into sample wells of the target did not require any pretreatment procedure to the target and did not involve chemical binding reactions. To isolate phosphopeptides, digests were loaded into the wells of the modified target for 10 min incubation, followed by rinsing with washing buffer to remove unbound species; matrix was then added to the captured phosphopeptides prior to analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Capturing the phosphopeptides on the modified target simplified significantly analytical operations and reduced sample loss. This approach has been applied to solution digests of alpha-casein, beta-casein, and a mixture of five proteins; a number of phosphopeptides were confidently detected. Phosphopeptides from digests of 10 fmol beta-casein could be isolated and detected by MALDI-TOFMS with this method. In addition, this approach has been applied successfully to the isolation of phosphopeptides from in-gel digestive products of sub-pmol phosphoproteins after separation by sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE).  相似文献   

10.
The use of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) for the quantitative determination of phospholipid (PL) molecular species has been problematic, due primarily to the formation of multiple signals (corresponding to the molecular ion and other adducts) for some classes of PL. For example, analysis of phosphatidylcholine (PC) yielded signals that corresponded to protonated and sodiated molecules in the MALDI spectrum. The resulting spectral overlap among various molecular species (e.g. [PC(16:0/18:2) + Na] and [PC(18:2/18:3)]) made it impossible to ascertain their relative amounts using this technique. Other spectral ambiguities existed among different structural isomers, such as PC(18:1/18:1) and PC(18:0/18:2). We determined that molecular species could be resolved by MALDI-TOFMS by first removing the polar head (e.g. phosphocholine) from the phospholipid to effect production of only the sodiated molecules of the corresponding diacylglycerols (DAGs). Analysis of the resulting spectrum allowed unequivocal determination of the molecular species profile of PC from potato tuber and soybean. Estimation of fatty acid composition based on the molecular species determined by MALDI-TOFMS analysis agreed with that from GC-FID analysis. Post-source decay (PSD) was used to resolve standard isomers of PC (e.g. 18:1/18:1 vs. 18:0/18:2). Our results indicated that PSD is a useful approach for resolving structural isomers of PL molecular species.  相似文献   

11.
This study presents matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) as a powerful tool to analyze and characterize oligonucleotides covalently linked to a solid support during their synthesis. The analysis of the fragment ions generated either in negative or positive mode allows direct and easy access to the nucleotide sequence and identification of the internucleosidic linkage. The mechanisms of the fragmentation of the solid-supported oligonucleotides induced by MALDI-TOFMS are discussed. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

12.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and laser desorption/ionization (LDI-)TOFMS have been used to characterize Suwannee River humic substances, obtained from the International Humic Substances Society (IHSS), and Armadale soil fulvic acid (ASFA). An array of MALDI matrices were tested for use with humic substances, including alpha-cyano-4-hydroxycinammic acid (CHCA), 2-(4-hydroxyphenylazo)benzoic acid (HABA), 2,5-dihydroxybenzoic acid (DHBA), sinapinic acid, dithranol and norharmane. DHBA yielded the best results, exhibiting superior ionization efficiency, low noise, broad applicability to the analytes of interest, and most importantly producing an abundance of high mass ions, the highest observed being m/z 1848. A number of sample preparation modes were investigated; the overlayer method improved sample/matrix homogeneity and hence shot-to-shot reproducibility. The choice of the matrix, mass ratio of analyte to matrix, and the sample preparation protocol, were found to be the most critical factors governing the quality of the mass spectra. Matrix suppression was greatly enhanced by ensuring good mixing of matrix and analyte in the solid phase, proper optimization of the matrix/analyte ratio, and optimizing delayed extraction to ensure complete matrix-analyte reaction in the plume before ions are moved to the flight tube. A number of common features, in particular specific ions which could not be attributed to the matrices or to contaminants, were present in the spectra of all the humic substances, regardless of origin or operational definition. Additionally, a prominent repeating pattern of peaks separated by 55, 114 and 169 Da was clearly observed in both LDI and MALDI, suggesting that the humic compounds studied here may have quasi-polymeric or oligomeric features.  相似文献   

13.
An automated sample preparation for high throughput accurate mass determinations by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed. Sample preparation was performed with an automated workstation and automated mass analyses were performed with a commercial MALDI-TOF mass spectrometer. The method was tested with a 41-sample library. MALDI-TOFMS was found to give the needed sensitivity, accurate mass measurement, and soft ionization necessary for structure confirmation, even of mixtures. A mass accuracy of 5 ppm or less was obtained in over 80% of known compound measurements. A mass accuracy better than 10 ppm was obtained for all measurements of known compounds. Analyses of parallel synthesis products resulted in 77% of the measurements with a mass accuracy of 5 ppm or better.  相似文献   

14.
15.
We evaluated several aqueous-based sample preparation protocols for the analysis of poly(methacrylic acid) (PMAA) by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The sample contained a pentaerythritol tetra(3-mercaptopropionate) end-group, and was characterized in positive and negative ion modes using 2,5-dihydroxybenzoic acid (DHB) and 2,4,6-trihydroxyacetophenone (THAP) matrices. The major series observed were the [M + Na](+) species, in positive ion mode, and the [M - H](-) species, in negative ion mode. The performance of DHB and THAP matrices was comparable in positive ion mode, but THAP outperformed DHB in negative ion mode. The use of ion-exchange beads (IXB) benefited the analysis, while the addition of sodium acetate (NaOAc) or trifluoroacetic acid (TFA) proved disadvantageous in positive ion mode.  相似文献   

16.
The intact fungal spores of several strains of four Aspergillus species, Aspergillus flavus, A. oryzae, A. parasiticus, and A. sojae, were directly analyzed by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Very simple MALDI mass spectra are obtained by directly mixing spores with a matrix such as alpha-cyano-4-hydroxycinnamic acid or sinapinic acid. The mass spectra are obtained from the ablation of cell walls of spores owing to the acidity of the matrix solution. The MALDI results show that aflatoxigenic strains and non-aflatoxigenic strains have different mass peak profiles. Furthermore, the MALDI results of non-aflatoxigenic A. flavus and A. parasiticus spores resemble those of the closely related A. oryzae and A. sojae spores, respectively.  相似文献   

17.
The utility of post-source decay (PSD) matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was investigated for the structural analysis of phosphatidylcholine (PC). PC did not produce detectable negative molecular ion from MALDI, but positive ions were observed as both [PC+H](+) and [PC+Na](+). The PSD spectra of the protonated PC species contained only one fragment corresponding to the head group (m/z 184), while the sodiated precursors produced many fragment ions, including those derived from the loss of fatty acids. The loss of fatty acid from the C-1 position (sn-1) of the glycerol backbone was favored over the loss of fatty acid from the C-2 position (sn-2). Ions emanating from the fragmentation of the head group (phosphocholine) included [PC+Na-59](+), [PC+Na-183](+) and [PC+Na-205](+), which corresponded to the loss of trimethylamine (TMA), non-sodiated choline phosphate and sodiated choline phosphate, respectively. Other fragments reflecting the structure of the head group were observed at m/z 183, 146 and 86. The difference in the fragmentation patterns for the PSD of [PC+Na](+) compared to [PC+H](+) is attributed to difference in the binding of Na(+) and H(+). While the proton binds to a negatively charged oxygen of the phosphate group, the sodium ion can be associated with several regions of the PC molecule. Hence, in the sodiated PC, intermolecular interaction of the negatively charged oxygen of the phosphate group, along with sodium association at multiple sites, can lead to a complex and characteristic ion fragmentation pattern. The preferential loss of sn-1 fatty acid group could be explained by the formation of an energetically favorable six-member ring intermediate, as apposed to the five-member ring intermediate formed prior to the loss of sn-2 fatty acid group.  相似文献   

18.
A method for the detection of BPDE-d guanosine adducts using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described and illustrated. The results indicate that MALDI is capable of detecting two other DNA benzopyrene adducts, which are trace products formed during the synthesis of BPDE-d guanosine. This MALDI-TOFMS method offers the potential for the detection of DNA adducts in human tissue using very limited sample purification and preparation.  相似文献   

19.
Simple, rapid and inexpensive one-step reverse micellar microextraction (RMME) procedures were combined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) for the determination of thiol-containing peptides and amino acids. In this investigation, a thiol-containing peptide (HW6) was chosen as model compound to understand the mechanism of RMME. The electrostatic interactions between the thiol-containing peptide and reverse micelles were proposed to be reason for the transfer of analytes from the aqueous phase to the organic phase. Reverse micelles were formed by the cationic surfactant, methyltrioctylammonium chloride (MTOAC). The best extraction efficiency of HW6 was obtained under the following conditions: pH 11.0, ionic strength 5.0 mM of KCl and micelle concentration 7.0 mM of MTOAC. The limits of detection (LODs) obtained for HW6 in water, urine and plasma samples were 0.15, 0.19 and 0.28 microM, respectively, with relative standard deviation (RSD) values in the range +/-8.8-10.5%. The sensitivity obtained in water by the present method was 45-fold higher than that of the conventional use of atmospheric-pressure (AP)-MALDI MS. Furthermore, the applicability of the proposed approach was extended for the determination of thiol-containing amino acids in sample solutions by using MALDI time-of-flight (TOF) MS.  相似文献   

20.
The use of an atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) source was employed with an atmospheric pressure ion mobility spectrometer (APIMS) and an orthogonal acceleration reflector time-of-flight mass spectrometer (TOFMS) to analyze dipeptide and biogenic amine mixtures from a liquid glycerol 2,5-dihydroxybenzoic acid (DHB) matrix. Improved sensitivities were obtained by the addition of a localized electrical (corona) discharge in conjunction with the AP-MALDI source. Enhanced sample ionization efficiency created by this combination provided an overall elevation in signal intensity of approximately 1.3 orders in magnitude. Combinations of three dipeptides (Gly-Lys, Ala-Lys, and Val-Lys) and nine biogenic amines (dopamine, serotonin, B-phenylethylamine, tyramine, octopamine, histamine, tryptamine, spermidine, and spermine) were resolved in less than 18 ms. In many cases, reduced mobility constants (K(o)) were determined for these analytes for the first time. Ion mobility drift times, flight times, arbitrary signal intensities, and collision-induced dissociation (CID) fragmentation product signatures are reported for each of the samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏