首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 9 毫秒
1.
Horseradishperoxidase(HRP)canstronglycatalyzethereactionofH2O2oxidizingophenylenediamine(OPD),thechromaticproductofwhichcanbedetectedinenzymelinkedimmunosorbentassay(ELISA)withspectrophotometry[1].Involtammetricenzymelinkedimmunoassay[2—4],OPDH2O2HRPsystemhasf…  相似文献   

2.
The o-aminophenol (OAP)-H_2O_2-horseradish peroxidase (HRP) voltammetric enzyme-linked immunoassay new system has extremely high sensitivity. HRP can be measured with a detection limit of 6.0×10~-(10) g/L and a linear range of 1.0×10~(-9)—4.0×10~(-6) g/L. The pure product of H_2O_2 oxidizing OAP catalyzed by HRP was prepared with chemical method. The enzyme-catalyzed reaction has been investigated with electroanalytical chemistry, UV/Vis spectrum, IR spectrum, ~(13)C NMR, ~1H NMR, mass spectrum, elemental analysis, etc. Under the selected enzyme-catalyzed reaction conditions, the oxidation product of OAP with H_2_O2 catalyzed by HRP is 2-aminophe-noxazine-3-one. The processes of the enzyme-catalyzed reaction and the electroreduction of the product of the enzymecatalyzed reaction have been described.  相似文献   

3.
A voltammetric enzyme-linked immunoassay based on a new system of ODA-H2O2-HRP has first been developed and used in the detection of HRP and labelled HRP. By this method, the enzyme-catalyzing reaction of H2O2 oxidizing odianisidine (ODA) couples the electrode-reduction reaction of the oxidizing product of odianisidine, which produces a sensitive polarographic wave at potential of -0.56V (SCE) in Britton-Robinson buffer solution. In using this polarographic wave, a detection limit to HRP is 3.7×10-12g/mL and a linear range 1.0×10-11-2.0×10-9g/mL. And the mechanisms of the coupling reaction and the process of electro-reduction in the ODA-H2O2-HRP voltammetric enzyme-linked immunoassay system have also been carefully studied.  相似文献   

4.
OAP-H~2O~2-HRP伏安酶联免疫分析新体系测定人血清铁蛋白   总被引:3,自引:1,他引:2  
张书圣  焦奎  陈洪渊 《化学学报》1999,57(8):914-921
首次提出邻氨基酚(OAP)-H~2O~2-辣根过氧化物酶(HRP)伏安酶联免疫分析新体系并用于人血清中铁蛋白的测定.本方法以线性扫描二阶导数伏安法栓测HRP催化H~2O~2氧化OAP的产物,用于游离HRP和各种HRP标记物的测定,灵敏度均高于经典的ELISA显色光度法.测定游HPR的线性范围为1.0x10^-^1^2-4.0x10^-^9g/mL,检测限达6.0x10^-^1^3g/mL.本法对铁蛋白测定的线性范围为0.2-320ng/mL,用所建立的方法对人血清样品进行了测定,并与现行的ELISA显色光度法进行对照,二者相关性很好.对此伏安酶联免疫分析新体系的电极还原过程也进行了详细的研究.  相似文献   

5.
MAP-H~2O~2-HPR伏安酶联免疫分析新体系和光谱及电化学研究   总被引:5,自引:0,他引:5  
提出了间氨基酸(MAP)-H~2O~2-辣根过氧化物酶(HRP)伏安酶联免疫分析新体系.本方法以线性扫描二阶导数伏安法检测HRP催化H~2O~2氧化MAP的产物,用于游离HRP和各种HRP标记物的测定,灵敏度均高于经典的ELISA显色光度法.测定游离HRP的线性范围为1.0x10^-^8-1.0x10-6/L,检测限达3.8x10^-^9g/L.制备出了HRP催化H~2O~2氧化MAP的产物纯品并应用电化学分析,高效液相色谱,元素分析,紫外-可见光谱,红外光谱,^1H核磁共振谱,^1^3C核磁共振谱及质谱等技术对体系酶促反应进行了深入的研究.在选择的酶促反应条件下,生成的产物为2-氨基-5-[(3-差苯基)]-2,5-环己烯基-1,4-二酮.提出了酶催化反应机理及其产物的电极还原过程。  相似文献   

6.
Jiao K  Zhang S  Wei L  Liu C  Zhang C  Zhang Z  Liu J  Wei P 《Talanta》1998,47(5):47-1137
o-Dianisidine (ODA)-H2O2-horseradish peroxidase (HRP) voltammetric enzyme-linked immunoassay system has firstly been used for the detection of tobacco mosaic virus (TMV). HRP catalyzes strongly the oxidation reaction of ODA by H2O2, the product of which produces a sensitive second order derivative linear sweep voltammetric peak at potential of −0.56 V (versus SCE) in Britton–Robinson (BR) buffer. HRP activity has been measured with this voltammetric peak and TMV detected through immunoreaction. The detection limit for HRP is 9.25×10-7 mU l−1 and the linear range is 2.5×10−6–5.0×10−4 mU l−1. The detection limit for the clarified TMV is 0.25 ng ml−1 and the highest dilution ratio detected for the infected leaf sap is 1:8×105. The sensitivity for TMV detection with this method is higher than that with the enzyme-linked immunosorbent spectrophotometric assay (ELISA) using ODA-H2O2-HRP system. The processes of the enzyme-catalyzed reaction and the electro-reduction of the product of the enzyme-catalyzed reaction have been described.  相似文献   

7.
Immunoassay is one of the biochemical analytical techniques using the specific antigen antibody com-plexation for analytical purposes. It has extensive ap-plication in clinical diagnostics, prevention and cure of diseases, and virus diagnostics. The presentation and progress of immunoassay methodology are one of the greatest achievements of bioanalytical chemistry. It is estimated that several-hundred millions of immuno-analytical determinations are carried out every year all over the world. E…  相似文献   

8.
提出了一种新的辣根过氧化物酶的底物-甲基红,它本身具有电化学活性,能够在静汞电极上发生还原反应,产生灵敏的伏安电流信号.以H2O2为氧化剂,HRP能催化氧化还原反应的发生,使甲基红被氧化分解,其平衡浓度降低,对应的还原峰电流降低,峰电流的降低值与HRP的质量浓度在5.0×10-8~5.0×10-7g/mL之间呈线性关系,对2.0×10-7g/mL HRP进行11次测定的相对标准偏差为4.6%,方法的检出限为1.8×10-8g/mL.应用于IgG-HRP和Avidin-HRP的测定.  相似文献   

9.
磷酸苯酯-碱性磷酸酯酶伏安酶联免疫分析新体系的研究   总被引:1,自引:0,他引:1  
研究了以磷酸苯酯为底物微分脉冲伏安法测定碱性磷酸酯酶 (ALP)的方法。磷酸苯酯在ALP的催化作用下水解生成苯酚 ,苯酚在玻碳电极上 0 .70V(vs.Ag/AgCl)左右产生氧化电流 ,氧化电流随着酶浓度的增大而增大 ,借助此氧化电流可以测定ALP ,并进而可用于以ALP为标记酶的酶免疫分析。对酶催化反应条件和酶催化反应产物的测定条件进行了详细的研究 ,测定游离ALP的线性范围是 0 .0 6U/L~ 1 .0× 1 0 3U/L ,检出限为 0 .0 6U/L  相似文献   

10.
OT-H2O2-HRP伏安酶联免疫分析新体系   总被引:13,自引:0,他引:13  
焦奎  张书圣  韦璐  刘澄凡 《化学学报》1997,55(11):1121-1129
本文首次提出了邻联甲苯胺(OT)-H2O2-辣根过氧化物酶(HRP)伏安酶联免疫分析新体系。本方法以线性扫描二阶导数伏安法检测HRP催化H2O2氧化OT的产物, 用于游离HRP和各种HRP标记物测定, 灵敏度比经典的ELISA光度法分别高两个至四个数量级。测定游离HRP的检测限达到1.8×10^-^1^2 g/mL, 线性范围为5.0×10^-^1^2-1.0×10^-^8 g/mL。对此伏安酶联免疫分析新体系的偶合反应机理及电极还原过程也进行了详细的研究。  相似文献   

11.
Zhang S  Zou J  Yu F 《Talanta》2008,76(1):122-127
By introducing heterocyclic compound to immunoassay system as an electrochemical substrate for the fist time, a new voltammetric enzyme-linked immunoassay system of 3-hydroxyl-2-aminopyridine (HAP)-H(2)O(2)-horseradish peroxidase (HRP) has been developed. HAP was oxidized with H(2)O(2) catalyzed by HRP, and the resulting electroactive product produced a sensitive voltammetric peak at potential of -0.36 V (vs. SCE) in Britton-Robinson (BR) buffer solution. The process of the enzyme-catalyzed reaction and the electro-reduction of the product have been investigated in detail. The linear range for detection of free HRP was from 4.0x10(-13) to 1.0x10(-9) g/mL with a detection limit of 1.2x10(-13) g/mL. The new system has been successfully applied for the assay of alpha-fetoprotein (alphaFP) in human serum ranging from 0.1 to 200 ng/mL with a detection limit of 0.1 ng/mL, which was 10 times lower than that of traditional spectrophotometric enzyme-linked immunosorbent assay (ELISA) method. HAP-H(2)O(2)-HRP voltammetric enzyme-linked immunoassay showed a promising alternative approach in the detection of alphaFP in clinical diagnosis.  相似文献   

12.
An improved enzyme-linked immunosorbent assay (ELISA) for the determination of southern bean mosaic virus (SBMV) with linear sweep voltammetry based on a new system of p-aminophenol (PAP)-H2O2-horseradish peroxidase (HRP) has firstly been developed. The enzymatic product 3-[(4-hydrox-yphenyl) amino]-4-(2-amino-5-hydroxyphenyl)-6-[ (4-hydrox-yphenyl)imino]-2,4-cyclohexadiene-l-one, produced from the oxidation of PAP with H2O2 catalyzed by HRP, yielded a sensitive linear sweep voltammetric response at - 0.45 V ( vs. SCE) in Britton-Robinson (BR) buffer solution. Based on the voltammetric peak, HRP can be measured with a detection limit of 0.4 mU/L and a linear range of 1.0-1.0 × 102 mU/ L. The detection limit for the SBMV is 8.0 ng/mL and the highest dilution ratio for the detection of infected leaf sap is 1: 1.5×105.  相似文献   

13.
A novel class of redox-active molecular tags, poly(o-phenylenediamine)-carried nanogold particles (GPPDs), was first synthesized and functionalized with horseradish peroxidase-anti-prolactin conjugates (HRP-anti-PRL). Thereafter, a specific sandwich-type electrochemical immunoassay was designed for determination of prolactin (PRL) by using GPPD-labeled HRP-anti-PRL conjugates as molecular tags on anti-PRL antibody-modified glassy carbon electrode. Compared with pure gold nanoparticles and poly(o-phenylenediamine) microspheres, the as-prepared GPPDs increased the surface coverage of the nanostructures, and enhanced the immobilization amount of biomolecules. Several labeling protocols compromising GPPD-labeled HRP-anti-PRL, nanogold particles-labeled HRP-anti-PRL and poly(o-phenylenediamine) microspheres-labeled HRP-anti-PRL, were investigated for detection of PRL, and improved analytical features were obtained with the GPPD-based strategy. With the GPPD labeling method, dependence of the electrochemical signals on the incubation time and pH of the assay solution were also studied. The strong attachment of HRP-anti-PRL to the GPPDs resulted in a good repeatability and intermediate reproducibility down to 9.8%. The dynamic concentration range spanned from 0.5 to 180 ng mL−1 PRL with a detection limit of 0.1 ng mL−1 at the 3Sblank level. No significant differences at the 95% confidence level were encountered in the analysis of 10 spiked blank cattle serum samples between the developed immunoassay and enzyme-linked immunosorbent assay method for determination of PRL.  相似文献   

14.
自1938年Tsumaki报道犤1犦氧载体以来,这方面的研究已有很大进展犤2犦,只是理论研究居多。氧载体的氧合常数是氧载体研究中的一个重要参数,它的测定是氧载体研究中的一项重要内容,用pH电位法测定氧载体的氧合常数已有研究报道犤2~4犦,作者在研究中发现,邻苯二胺合钴(o-Phdn-Co)配合物在固相和水溶液中与O2反应时表现出很大差异,其反应产物的组成比分别为液相配合物Co∶O2=2∶1,而固相配合物Co∶O2=1∶2,为究其成因和进行理论探讨,有必要先测定其氧合常数。由于o-Phdn-Co配合物的配位常数也未见文献…  相似文献   

15.
Zhang S  Jiao K  Chen H  Wang M 《Talanta》1999,50(1):95-101
A voltammetric enzyme-linked immunoassay based on new system of m-aminophenol (MAP)-H(2)O(2)-horseradish peroxidase (HRP) has firstly been developed and used for the detection of HRP, labelled HRP and ferritin in human serum. HRP or labelled HRP catalyzes the oxidation reaction of MAP with H(2)O(2), the product of which produces a sensitive voltammetric peak at potential of -0.46 V (vs. SCE) in Britton-Robinson (BR) buffer solution. By using this voltammetric peak, HRP can be measured with a detection limit of 9.5x10(-1) mU/l and a linear range of 2.5-2.5x10(2) mU/l. The detection limit to ferritin is 0.25 ng/ml and the linear range 0.25-320 ng/ml. The processes of the electro-reduction of the product of the enzyme-catalyzed reaction have been investigated in detail.  相似文献   

16.
以变色酸2R为底物测定辣根过氧化物酶的研究   总被引:4,自引:0,他引:4  
焦奎  徐静  孙伟  江宏 《分析化学》2004,32(5):593-597
变色酸 2R(CT2R)是一种具有电化学活性的物质 ,在碱性条件下 ,该物质在滴汞电极上 - 6 6 0mV(vs.SCE)左右产生还原波 ,加入H2 O2 和辣根过氧化物酶 (HRP)后 ,该物质被氧化生成具有非电化学活性的物质 ,导致溶液中游离的CT2R浓度降低 ,相应还原波波高降低 ,HRP在一定含量范围内与伏安峰的降低值具有良好的线性关系。通过测定波高的降低值可测定HRP ,测定游离HRP的线性范围是 4 .0× 10 -5~ 4 .0× 10 -3 g/L。对酶促反应的动力学进行了研究 ,反应的米氏常数Km =1.38mmol/L ,最大反应速率Vmax=5 3.9nA/min。  相似文献   

17.
A new voltammetric enzyme-linked immunoassay system of 3,3'-diaminobenzidine (DAB)-H2O2-horseradish peroxidase (HRP) has been presented and used for the sensitive detection of carcinoembryonic antigen (CEA) in human serum. In this proposed procedure, DAB was firstly used as the electroactive substrate in the HRP catalyzed oxidation reaction in the present of H2O2. The generated product produced a sensitive second-order derivative linear sweep voltammetric peak at potential of -0.62 V (vs. SCE) in Britton-Robinson (BR) buffer solution. The free HRP could be measured in a linear range from 2.5 x 10(-6)-2.5 x 10(-2) unit/ml and a detection limit of about 1.5 x 10(-6) unit/ml. Under the optimal experiment conditions, CEA could be detected in the linear range from 0.50 to 80 ng/ml with a detection limit of 0.5 ng/ml. The proposed electrochemical enzyme-linked immunosorbent assay method is simple, inexpensive, reproducible and sensitive, which shows promising for detecting CEA in the clinical diagnosis.  相似文献   

18.
    
2,3-Dihydro-1H-1,5-benzodiazepine derivatives are synthesized by the condensation of o-phenylenediamine and various ketones in the presence of catalytic amount of LaCl3 under solvent-free condition. Dedicated to Loknete Balasaheb Vikhe Patil on the occasion of his 75th birthday  相似文献   

19.
An easy and convenient synthetic procedure for the preparation of benzodiazepines by coupling microwaves with the solvent technique have been elaborated.  相似文献   

20.
Electrochemical behavior of poly-o-phenylenediamine (PoPhD) films in lithium perchlorate and perchloric acid solutions of different pH and constant ionic strength is studied using cyclic voltammetry, low-amplitude chronoamperometry, chronopotentiometry, and faradaic-impedance spectroscopy. The experimental results point to the diffusion–migration kinetics of charge transfer processes in redox-active PoPhD films and show that two such processes occur during oxidation–reduction of PoPhD. The processes are separated most fully at low concentrations of hydronium ions. Effect of the electrode potential and electrolyte composition on these processes is examined. Different methods yield similar results and permit their more reliable interpretation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号