首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A highly sensitive cathodic stripping voltammetric method for the determination of naringin is presented. It is based on the formation and accumulation of two naringin–mercury complexes at the electrode surface, followed by reduction of the surface species during a differential pulse voltammetric scan. The cathodic stripping responses at −0.25 V and −0.42 V, are evaluated with respect to various experimental conditions, such as composition and pH of the supporting electrolyte, naringin concentration, accumulation potential and preconcentration time. The new method is suitable for the determination of naringin concentrations between 0.1 mg l−1 (1.72×10−7 mol l−1) and 40 mg l−1 (6.88×10−5 mol l−1). A 3σ limit of detection of 32 μg l−1 (55 nmol l−1) can be reached. The relative standard deviation (r.s.d.) is <1.5%. Recovery experiments yielded a mean recovery of 97% (r.s.d.=4.1%). The application of the procedure to the selective determination of naringin in grapefruit juice is demonstrated.  相似文献   

2.
Molybdenum(VI) is determined by anodic stripping voltammetry using a carbon paste electrode modified in situ with cetyltrimethylammonium bromide (CTAB). The preconcentration of molybdenum is performed by adsorption and reduction of ion-pairs of cetyltrimethylammonium and molybdenum(VI) oxalate at a potential of −0.4 V vs. the saturated calomel electrode (SCE). The supporting electrolyte contains 0.01 M oxalic acid and 0.075 mM CTAB. Differential pulse anodic stripping voltammetry exploiting the reoxidation signal is used for the determination of trace levels of molybdenum(VI). Linearity between current and concentration exists for a range of 0.5–500 μg 1−1 Mo with proper preconcentration times; the limit of detection (calculated as 3σ) is 0.04 μg 1−1 with an accumulation period of 10 min.  相似文献   

3.
Zhou CL  Lu Y  Li XL  Luo CN  Zhang ZW  You JM 《Talanta》1998,46(6):1531-1536
A new method is described for the determination of antimony based on the cathodic adsorptive stripping of Sb(III) complexed with 2′,3,4′,5,7-pentahydroxyflavone(morin) at a static mercury drop electrode (SMDE). The reduction current of the adsorbed antimony complex was measured by 1.5th-order derivative linear-sweep adsorption voltammetry. The peak potential is at −0.51 V (vs. SCE). The effects of various parameters on the response are discussed. The optimized analytical conditions were found to be: supporting electrolyte, chloroacetic acid (0.04 mol/l, pH 2.3); concentration of morin, 5×10−6 mol/l; accumulation potential, −0.25 V (vs. SCE); scan rate, 100 mV/s. The limit of detection and the linear range were 7×10−10 mol/l and 1.0×10−93.0×10−7 mol/l Sb(III) for a 2-min accumulation time, respectively. This method has been applied to the determination of Sb(III) in steel and brass samples and satisfactory results were obtained. The adsorptive voltammetric characteristics and composition of the Sb(III)–morin complex were studied.  相似文献   

4.
Zeng B  Yang Y  Ding X  Zhao F 《Talanta》2003,61(6):819-827
A novel method for the determination of perphenazine has been developed. The method is based on the accumulation of perphenazine at a gold electrode modified with decanethiol (DEC) self-assembled monolayer (SAM) and its oxidation at about 0.6 V (vs. saturated calomel electrode (SCE)). Because some coexistent electroactives were blocked and perphenazine was selectively accumulated by the SAM, the electrode exhibited good selectivity and sensitivity. Various conditions were optimized for practical application. Under the selected conditions (i.e. 0.05 M pH 10 sodium borate buffer, accumulation time: 120 s, accumulation potential: −0.4 V, scan rate: 100 mV s−1), the anodic stripping peak current was linear to perphenazine concentration in the ranges of 6×10−9–5×l0−7 and 5×10−7–5×10−6 M with correlation coefficients of 0.998 and 0.995, respectively. For a 1.0×10−6 M perphenazine solution, the relative standard deviation of peak height was 2.3% (n=8). This method was applied to the determination of perphenazine in some drugs and the recovery was 92–101%. In addition, it was found that in the presence of perphenazine, the SAM structure changed a little and more needle holes appeared. However, the SAM could recover the original form when perphenazine and its redox product were removed from the monolayer by repeatedly cycling the electrode in a blank solution for a minute. The modified electrode was characterized by alternating current impedance and electrochemical probe.  相似文献   

5.
The cathodic adsorptive electrochemical behavior of guanine in the presence of some metal ions at the static mercury drop electrode was investigated. A 1.0×10−3 mol l−1 NaOH or a 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 solutions were used as supporting electrolytes. The reduction peak potential for guanine was found to be around −0.15 V, which is very close to the mercury reduction wave. A new peak appears at −0.60 V in the presence of copper or at −1.05 V in the presence of zinc. A square wave voltammetric procedure for electroanalytical determination of guanine in 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 containing 1.6×10−5 mol l−1of copper ions, was developed. An accumulation potential of −0.15 V during 270 s for the prior adsorption of guanine at the electrode surface was used. The response of the system was found to be linear in the range of guanine concentration from 6.62×10−8 to 1.32×10−7 mol l−1 and the detection limit was 7.0×10−9 mol l−1. The influence of DNA bases such as adenine, cytosine and thymine was also examined. Cyclic voltammetry was used to characterize the interfacial and redox mechanism.  相似文献   

6.
Zareh MM  Ghoneim AK  Abd El-Aziz MH 《Talanta》2001,54(6):1049-1057
The lipophilic ammonium salt of 1-pyrrolidine dicarbodithioic acid (PCDT)[I] was introduced as a selective ionophore for a sensitive Pb-ion selective electrode. Also, the effect of immobilization of 18-crown-6 (CW), into the above membrane, on the electrode performance was discussed. The slope of the PCDT-based [I] electrode was (26–30 mV decade−1), while it was (29-30 mV decade−1) for (PCDT+CW)-based [II] electrode according to the doping time. The linear concentration ranges were (1×10−6–1×10−1 M) and (5×10−5–1×10−1 M) for electrode types [I] and [II] after one-day doping. The working pH ranges were (5.0–10.0) and (7.0–10.0) for electrode types [I] and [II], respectively. Most of the common cations were tested for the evaluation of the electrode selectivity with correlation to the ionic radii of the tested cations. Among them only Na+, Ag+ and Fe3+ were the real interference. Application of using the electrode for the determination of lead in lubrication oil samples was performed with RSD (0.86–1.03%). The obtained results were compared to those of an atomic absorption spectrophotometric method.  相似文献   

7.
Ohura H  Imato T  Yamasaki S 《Talanta》1999,49(5):1383-1015
A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3–ClO2 and ClO3–HClO has been developed, using both a redox electrode detector and a Fe(III)–Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2 obtained by the transient potential change were enhanced 700–800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2 is as low as 5×10−8 M with use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3 was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3 was 2×10−6 M with the use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3–ClO2 or ClO3–HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2×10−5–2×10−4 M for ClO3, and 1×10−6–1×10−5 M for HClO and ClO2. The reproducibility of the present method was in the range 1.5–2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3 added to the sample.  相似文献   

8.
Agnihotri NK  Singh VK  Singh HB 《Talanta》1993,40(12):1851-1859
Derivative photometric methods for trace analysis of Th(IV) and UO2(II), and their simultaneous determination in mixtures using 5,8-dihydroxy-1,4-naphthoquinone in a micellar medium are reported. Molar absorptivity and Sandell's sensitivity of 1:2 Th(IV) and 1:1 UO2(II) complexes at their λmax, 614.5 nm and 637.0 nm are, 1.19 × 104 1/mol/cm and 1.12 × 104 1/mol/cm and 1.95 × 10−2 μg/cm2 and 2.13 × 10−2 μg/cm2 μg/cm2, respectively. Calibration graph is linear over the range 9.28 × 10−2−18.56 μg/ml of Th(IV) and 9.52 × 10−2−19.04 μg/ml of UO2(II). Though presence of Th(IV) and UO2(II) causes interference in each others determination, 9.28 × 10−1−9.28 μg/ml Th(IV) and 9.52 × 10−1−9.52 μg/ml UO2(II) when present together, can be simultaneously determined using derivative spectra.  相似文献   

9.
A PVC membrane electrode based on bis-2-thiophenal propanediamine (TPDA) coated directly on graphite is described. The electrode exhibits a Nernstian response for Cu2+ over a very wide concentration range (1.0×10−1 to 6.0×10−8 M) with a detection limit of 3.0×10−8 M (2.56 ng ml−1). It has a fast response time and can be used for at least 2 months without any major deviation. The proposed sensor revealed very good selectivities for Cu2+ over a wide variety of other metal ions and could be used in the pH range of 3.0–7.0. It was successfully used for direct determination of copper in black tea and as an indicator electrode in potentiometric titration of copper ion.  相似文献   

10.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

11.
van Staden JF  Stefan RI 《Talanta》1999,49(5):1472-1022
An on-line automated system for the simultaneous flow injection determination of calcium and fluoride in natural and borehole water with conventional calcium-selective and fluoride-selective membrane electrodes as sensors in series is described. Samples (30 μl) are injected into a TISAB II (pH=5.50) carrier solution as an ionic strength adjustment buffer. The sample-buffer zone formed is first channeled to a fluoride-selective membrane electrode and then via the calcium-selective membrane electrode to the reference electrodes. The system is suitable for the simultaneous on-site monitoring of calcium (linear range 10−5–10−2 mol l−1 detection limit 1.94×10−6 mol l−1 recovery 99.22%, RSD<0.5%) and fluoride (linear range 10−5–10−2 mol l−1 detection limit 4.83×10−6 mol l−1 recovery 98.63%, RSD=0.3%) at a sampling rate of 60 samples h−1.  相似文献   

12.
Flow injection (FI) analysis of copper as the copper diethylthiocarbamate complex (Cu(Et2dtc)2) has been performed in a high resistance toluene carrier stream. The method is based on the oxidation of the copper complex at a platinum microelectrode fabricated to fit a Metrohm wall-jet flow cell. Electrodes of sizes 5 to 25 μm radii were tested in toluene-based carriers containing either 0.03 M tetrahexylammonium perchlorate (Hex4NClO4) or 35% acetonitrile. Detection limits (3 : 1 signal to noise ratio) in the range 1 × 10−7 M (5 μm radius electrode) to 5 × 10−8 M (25 μm radius electrode) were achieved, which are comparable to detection limits reported in lower resistance media under similar conditions. The system was applied to the analysis of copper in water samples after extraction of the metal as its diethyldithiocarbamate into toluene and good agreement was found with data obtained by other voltammetric methods.  相似文献   

13.
Three different mixed aza-thioether crowns containing a 1,10-phenanthroline sub-unit were investigated to characterize their abilities as copper(II) ion carriers in PVC-membrane electrodes. The electrode based on L1 exhibited a Nernstian response for Cu2+ ions over a wide concentration range (2×10−1 to 1×10−5 M) with a limit of detection of 8.0×10−6 M (0.5 p.p.m.). The response time of sensor is 15 s, and the membrane can be used for more than 3 months without observing any deviation. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, transition and heavy metal ions, and could be used in a pH range of 2.5–5.5. It was applied to the direct determination and potentiometric titration of the copper(II) ion.  相似文献   

14.
Pei J  Li XY 《Talanta》2000,51(6):2379-1115
A thin film of mixed-valent CuPtCl6 is deposited on a glassy carbon electrode by continuous cyclic scanning in a solution containing 3×10−3 M CuCl2+3×10−3 M K2PtCl6+1 M KCl in the potential range from 700 to −800 mV. The cyclic voltammetry is used to study the electrochemical behaviors of nitrite on CuPtCl6/GC modified electrode and the electrode displays a good catalytic activity toward the oxidation of nitrite. The effects of the film thickness, pH, the electrode stability and precision have been evaluated. Experiments in flow-injection analysis are performed to characterize the electrode as an amperometric sensor for the detection of nitrite. The modified electrode shows a wide dynamic range, quite a low detection limit and short response time. The linear relationship between the flow-injection peak currents and the concentrations of nitrite is at a range of 1×10−7–2×10−3 M with a detection limit of 5×10−8 M.  相似文献   

15.
An adsorptive stripping voltammetric (AdSV) procedure for simultaneous determination of Ni(II) and Co(II) in the presence of nioxime as a complexing agent at an in situ plated lead film electrode was described. The Co(II) signal was enhanced by exploitation of the catalytic process in the presence of nitrite. Ni(II) and Co(II) signals are better separated than in the case of bismuth film electrodes. Calibration graphs for an accumulation time of 120 s are linear from 1 × 10−9 to 1 × 10−7 mol L−1 and from 1 × 10−10 to 5 × 10−9 mol L−1 for Ni(II) and Co(II), respectively. The proposed procedure was applied for Ni(II) and Co(II) determination in water certified reference materials.  相似文献   

16.
Norfloxacin, 1-ethyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylic acid (NORH), reacts with aluminium(III) ion forming the strongly fluorescent complex [Al(HNOR)]3+, in slightly acidic medium. The complex shows maximum emission at 440 nm with excitation at 320 nm. The fluorescence intensity is enhanced upon addition of 0.5% sodium dodecylsulphate. Fluorescence properties of the Al-NOR complex were used for the direct determination of trace amounts of NOR in serum. The linear dependence of fluorescence intensity on NOR concentration, at a NOR to Al concentration ratio of 1:10, was found in the concentration range 0.001–2 μg/ml NOR with a detection limit of 0.1 ng/ml. The ability of aluminium (III) ion to form complexes with NOR was investigated by titrations in 0.1 M LiCl medium, using a glass electrode, at 298 K, in the concentration range: 2 × 10−4 ≤ [Al] ≤ 8 × 10−4; 5 × 10−4 ≤ [NOR] ≤ 9 × 10−4 mol/dm3; 2.8 ≤ pH ≤ 8.3. The experimental data were explained by the following complexes and their respective stability constants, log(β ± σ): [Al(HNOR)], (14.60 ± 0.05); [Al(NOR)], (8.83 ± 0.08); [A1(OH)3(NOR)], (−14.9 ± 0.1), as well as several pure hydrolytic complexes of A13+. The structure of the [Al(HNOR)] complex is discussed, with respect to its fluorescence properties.  相似文献   

17.
A PVC membrane electrode for lead ions based on 5,5′-dithiobis-(2-nitrobenzoic acid) as membrane carrier was prepared. The electrode exhibits a Nernstian response for Pb2+ over a wide concentration range (1.0×10−2–4.0×10−6 M). It has a relatively fast response time and can be used for at least 3 months without any divergence in potentials. The proposed electrode revealed good selectivities for Pb2+ over a wide variety of other metal ions and could be used in a pH range of 2.0–7.0. It was used as an indicator electrode in potentiometric titration of lead ions and in direct determination of lead in water samples.  相似文献   

18.
Crew A  Cowell DC  Hart JP 《Talanta》2008,75(5):1221-1226
This paper reports on the development of a novel electrochemical assay for Zn2+ in human sweat, which involves the use of disposable screen-printed carbon electrodes (SPCEs). Initially, SPCEs were used in conjunction with cyclic voltammetry to study the redox characteristics of Zn2+ in a selection of supporting electrolytes. The best defined cathodic and anodic peaks were obtained with 0.1 M NaCl/0.1 M acetate buffer pH 6.0. The anodic peak was sharp and symmetrical which is typical for the oxidation of a thin metal film on the electrode surface. This behaviour was exploited in the development of a differential pulse anodic stripping voltammetric (DPASV) assay for zinc. It was shown that a deposition potential of −1.6 V versus Ag/AgCl and deposition time of 60 s with stirring (10 s equilibration) produced a well-defined stripping peak with Epa = −1.2 V versus Ag/AgCl. Using these conditions, the calibration plot was linear over the range 1 × 10−8 to 5 × 10−6 M Zn2+. The precision was examined by carrying out six replicate measurements at a concentration of 2 × 10−6 M; the coefficient of variation was calculated to be 5.6%. The method was applied to the determination of the analyte in sweat from 10 human volunteers. The concentrations were between 0.39 and 1.56 μg/mL, which agrees well with previously reported values. This simple, low-cost sensitive assay should have application in biomedical studies and for stress and fatigue in sports studies.  相似文献   

19.
The photochemical reaction of azide derivatives induced by ultraviolet (UV) laser in matrix-assisted laser desorption/ionization mass spectrometry (MALDI) is reported. A novel synthesized class of azide aromatic derivatives, spin-labeled photoaffinity non-nucleoside adenosine triphosphate (ATP) analogs which are useful probes in study of muscle contraction mechanism, is used in this investigation. In the negative ion MALDI spectra of these ATP analogs, “fingerprint” peaks corresponding to [M − 10 − 1], [M − 12 − 1], [M − 16 − 1], [M − 26 − 1], [M − 28 − 1], [M − 41 − 1], and [M − 42 − 1] were observed with relative intensities depending on the MALDI matrix. Only the [M − 16 − 1] is present in the similar mass spectra of the analog in which the azido group is replaced by a hydrogen. A model is suggested for the photochemical reactions of azide derivatives under UV laser irradiation. The photoreaction fingerprint information is diagnostically useful in characterization of azido compounds, especially for spin-labeled photoaffinity non-nucleoside ATP analogs.  相似文献   

20.
Wang Q  Li N 《Talanta》2001,55(6):243-1225
The thiolactic acid (TLA) self-assembled monolayer modified gold electrode (TLA/Au) is demonstrated to catalyze the electrochemical response of norepinephrine (NE) by cyclic voltammetry. A pair of well-defined redox waves were obtained and the calculated standard rate constant (ks) is 5.11×10−3 cm s−1 at the self-assembled electrode. The electrode reaction is a pseudo-reversible process. The peak current and the concentration of NE are a linear relationship in the range of 4.0×10−5–2.0×10−3 mol l−1. The detection limit is 2.0×10−6 mol l−1. By ac impedance spectroscopy the apparent electron transfer rate constant (kapp) of Fe(CN)3−/Fe(CN)4− at the TLA/Au electrode was obtained as 2.5×10−5 cm s−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号