首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
This work deals with simultaneous determination of ammonium, calcium, magnesium, sodium and potassium in drinking waters by capillary zone electrophoresis (CZE) on a column-coupling (CC) chip with suppressed hydrodynamic and electroosmotic transports. CZE separations were carried out in a propionate background electrolyte at a low pH (3.2) containing 18-crown-6-ether (18-crown-6) to reach a complete resolution of the cations. In addition, triethylenetetramine (TETA) coated the inner wall surface of the chip channels. The concentration limits of detection (cLOD) for the studied cations ranged from 4.9 to 11.5 μg/l concentrations using a 900 nl volume of the sample injection channel. 93–106% recoveries of the cations in drinking waters indicate a good predisposition of the present method to provide accurate analytical results.  相似文献   

2.
Guan J  Wang H  Ren L  Niu Q 《色谱》2012,30(1):107-110
建立了同时测定乙醛酸和草酸的毛细管区带电泳法。考察了缓冲溶液的种类、浓度和pH以及分离电压等因素对分离结果的影响。在缓冲溶液为20 mmol/L硼砂-5.5 mmol/L邻苯二甲酸氢钾(pH 9.0)、分离电压20 kV、检测波长212 nm的优化条件下,11 min内即可实现对目标物的分离。乙醛酸和草酸分别在0.8~20 g/L和1.2~20 g/L范围内线性关系良好,相关系数分别为0.9993和0.9975;方法的检出限分别为0.2和0.4 g/L(信噪比为3);样品的加标回收率为98.3%~102.5%,相对标准偏差为0.35%~0.61%。该方法操作简便、快速、成本低廉,已应用于实际样品的分析,并获得了令人满意的结果。  相似文献   

3.
4.
Capillary zone electrophoresis is proposed for the determination of magnesium and calcium ions in seawater. A carrier solution containing EDTA was adopted for the complexation of these ions and the effect of sodium chloride concentration in the sample solutions on the results was examined. It was found that magnesium and calcium ions could be determined without any pretreatment by injecting 100-fold diluted seawater samples. Linear calibration graphs were obtained for standard solutions containing up to 10.0 mg/l of calcium ion when both peak area and peak height were used. On the other hand, a linear calibration graph was obtained for standard solutions containing up to 20.0 mg/l of magnesium ion when the peak area was used, while a curved one was obtained when the peak height was used. Relative standard deviations were 0.8 and 1.2% when a standard solution containing 5.0 mg/l of magnesium and 8.0 mg/l of calcium ions was analysed 8 times using the peak area. Limits of detection for magnesium and calcium ions were 0.13 and 0.26 mg/l, respectively. The proposed method was applied to the determination of magnesium and calcium ions in surface and bottom seawater samples.  相似文献   

5.
Yang X  Hu X  Li F  Wang X  Cao Q 《色谱》2012,30(5):501-506
在系统优化了电解质溶液的pH、组成、浓度及仪器条件的基础上,建立了一种测定不同来源血竭中龙血素A和龙血素B的毛细管区带电泳(CZE)方法。采用20 kV的分离电压,25 ℃的毛细管柱温,211 nm的检测波长以及5 s的压力(3447 Pa)进样时间,在20 mmol/L的Na2B4O7缓冲溶液(用NaOH调节pH到9.98,含有10%(v/v,下同)乙腈、5.0%乙二醇和1.0%正丁醇)中,龙血素A和龙血素B在15 min内得到了有效分离与检测。方法的线性范围对于龙血素A和龙血素B分别为1.0~100.0 mg/L和0.5~100.0 mg/L。将该方法用于天然血竭及人工诱导血竭中龙血素A和龙血素B的测定,相对标准偏差在0.6%~3.8%之间,加标回收率在95.1%~105.8%之间。方法具有简单、快速、重现性较好和准确度较高的优点,可以用于血竭样品中龙血素A和龙血素B的测定。  相似文献   

6.
程晓昆  王利娟  杨更亮  程佳  张轶华 《色谱》2010,28(11):1089-1093
建立了匹伐他汀钙对映体的毛细管区带电泳(CZE)拆分方法。分别考察了电泳电压,缓冲溶液种类、浓度及pH值,环糊精种类及浓度,添加剂种类及浓度等参数对实验结果的影响,从而确定了匹伐他汀钙对映体的最佳拆分条件: 电泳电压为18 kV;运行缓冲溶液为80 mmol/L的Tris-HCl缓冲体系,pH值为3.20,其中含有50 mmol/L HP-β-CD(羟丙基-β-环糊精)和5 mmol/L SDS(十二烷基磺酸钠);采用重力进样,进样高度17 cm,进样时间为2 s。在优化的实验条件下,匹伐他汀钙对映体得到了较好的分离,分离度可达2.17。实验结果表明该方法可用于匹伐他汀钙对映体的分离,具有快速、便捷、准确性好等优点。  相似文献   

7.
8.
毛细管区带电泳法同时测定饮料中16种食品添加剂   总被引:1,自引:0,他引:1  
龙巍然  岑怡红  王兴益  白玉  刘虎威 《色谱》2012,30(7):747-751
建立了毛细管区带电泳法测定饮料中酸性红92、专利蓝V、荧光素二钠、酸性红1、靛蓝胭脂红、亮黑、丽春红6R、日落黄、苋菜红、柠檬黄等10种人工合成色素和苯甲酸、山梨酸、对羟基苯甲酸甲酯、对羟基苯甲酸乙酯、对羟基苯甲酸丙酯、对羟基苯甲酸丁酯等6种防腐剂的分析方法。考察了缓冲溶液种类、浓度、pH值及运行电压、温度等对分离的影响,确定最佳电泳条件为: 未涂层弹性石英毛细管柱(46 cm×50 μm),缓冲溶液为70 mmol/L硼酸(pH=9.5)(含体积分数为4%的乙腈),检测波长220 nm,电泳电压30 kV,进样时间5 s,电泳温度25 ℃。该法用于测定市售饮料样品得到满意结果: 在1~250 mg/L范围内线性关系良好,相关系数不小于0.9938,回收率在95.8%与108.7%之间。该法简便、准确,能够满足食品添加剂的常规检测要求。  相似文献   

9.
利用间接紫外毛细管区带电泳方法完成了对爆炸残留物中7种无机离子(K+,NH+4,NO-2,NO-3,SO2-4,ClO-3,ClO-4)的分离检测。阳离子测定采用的缓冲体系为10 mmol/L吡啶(pH 4.5)-3 mmol/L冠醚,K+和NH+4在2.6 min内达到基线分离,检出限分别为0.25 mg/L和0.10 mg/L(S/N=3)。阴离子测定采用的缓冲体系为40 mmol/L硼酸-1.8 mmol/L重铬酸钾-2 mmol/L硼酸钠(pH 8.6),氢氧化四甲铵为电渗流改性剂,5种阴离子在4.6 min内达到基线分离,检出限为0.10~1.85 mg/L。该方法已成功地应用于实际爆炸物样品种类的判定分析,取得了很好的结果。  相似文献   

10.
Analytical platforms that characterize charge heterogeneity in therapeutic proteins, such as mAbs, are important tools that can be used to define quality attributes. CZE separates protein moieties close to their native state and is a valuable physicochemical analytical method that can be used in parallel with other orthogonal methods for characterization and comparability. In this study, custom conditions for the analysis of charge heterogeneity of two mAbs were developed with regard to critical parameters in the BGE, running conditions, and sample treatment. The method application was tested for up to four mAbs and one mAb fragment. The electropherograms showed specific profiles and contrasting levels of basic and acidic isoforms with respect to the main isoform. Issues that surround this method, such as peak tailing and capillary lifetime, are summarized. Using this method, the identities of rituximab and trastuzumab were confirmed, based on the correspondence between the biosimilars and reference products, noninterference of the sample matrix, and the ability to separate spiked samples of related mAbs. The RSD of the isoform content and migration time for the method repeatability were less than 2 and 1%, respectively.  相似文献   

11.
《Electrophoresis》2017,38(13-14):1800-1805
Fast, simple, and accurate CE method enabling determination of lipoic acid (LA) in human urine has been developed and validated. LA is a disulfide‐containing natural compound absorbed from the organism's diet. Due to powerful antioxidant activity, LA has been used for prevention and treatment of various diseases and disorders, e.g. cardiovascular diseases, neurodegenerative disorders, and cancer. The proposed analytical procedure consists of liquid–liquid sample extraction, reduction of LA with tris(2‐carboxyethyl)phosphine, derivatization with 1‐benzyl‐2‐chloropyridinium bromide (BCPB) followed by field amplified sample injection stacking, capillary zone electrophoresis separation, and ultraviolet‐absorbance detection of LA‐BCPB derivative at 322 nm. Effective baseline electrophoretic separation was achieved within 6 min under the separation voltage of 20 kV (∼80 μA) using a standard fused‐silica capillary (effective length 51.5 cm, 75 μm id) and BGE consisted of 0.05 mol/L borate buffer adjusted to pH 9. The experimentally determined limit of detection for LA in urine was 1.2 μmol/L. The calibration curve obtained for LA in urine showed linearity in the range 2.5–80 μmol/L, with R 2 0.9998. The relative standard deviation of the points of the calibration curve was lower than 10%. The analytical procedure was successfully applied to analysis of real urine samples from seven healthy volunteers who received single 100 mg dose of LA.  相似文献   

12.
Summary An on-line flow injection-solid-phase extraction-capillary zone electrophoresis (FI-SPE-CZE) method has been developed for determination of cimetidine in human plasma. Sodium dodecylsulfate (SDS) was used as dynamic chemical modifier for elimination of capillary contamination by biological macromolecules. FI on-line preconcentration and cleaning of the analyte by means of a C18 microcolumn was performed automatically and CZE separation was performed consecutively without interruption of the applied voltage and between-run-washing of the capillary. A detection limit of 8 μgL−1 (3×σ) was achieved at a sample throughput of 12h−1. The approach was successfully used for a pharmacokinetic study of cimetidine.  相似文献   

13.
利用间接紫外毛细管区带电泳方法完成了对爆炸残留物中7种无机离子(K+,NH+4,NO-2,NO-3,SO2-4,ClO-3,ClO-4)的分离检测。阳离子测定采用的缓冲体系为10 mmol/L吡啶(pH 4.5)-3 mmol/L冠醚,K+和NH+4在2.6 min内达到基线分离,检出限分别为0.25 mg/L和0.10 mg/L(S/N=3)。阴离子测定采用的缓冲体系为40 mmol/L硼酸-1.8 mmol/L重铬酸钾-2 mmol/L硼酸钠(pH 8.6),氢氧化四甲铵为电渗流改性剂,5种阴离子在4.6 min内达到基线分离,检出限为0.10~1.85 mg/L。该方法已成功地应用于实际爆炸物样品种类的判定分析,取得了很好的结果。  相似文献   

14.
Jastrzebska A 《Talanta》2006,69(4):1018-1024
The usefulness of zone capillary electrophoresis (CZE) in combination with isotachophoresis (cITP) as on-line preconcentration technique was examined for analysis of tripolyphosphate (STPP) in meat and meat products. The mean concentrations of STPP in different types of meat products varied from 39 mg P2O5/100 g to 219 mg P2O5/100 g, these values are below the legal requirements. The detection (LOD) and quantification (LOQ) limits for STPP in extracted solutions were 0.80 mg P2O5/dm3 and 2.69 mg P2O5/dm3, respectively. Obtained results were compared with the Kjeldahl method. Accuracy (97.4-98.3%) was determined using recovery assay based on standard additions method. Precision was evaluated by within-day R.S.D. (1.40-2.19%), between-days R.S.D. (3.00-3.82%) and demonstrates the benefit of using this procedure for the routine analysis of STPP in meat and their products. The F-Snedecor test was employed to compare the precision of the used methods and calculated F-test values (4.00, 6.13) were less than the theoretical (6.39).  相似文献   

15.
A comprehensive survey of the use of capillary zone electrophoresis for the determination of organic acids in food and beverage samples is presented. The analytes discussed in this paper include low-molecular-mass organic acids, amino acids, vitamin related compounds and free fatty acids.  相似文献   

16.
17.
Ten purine and pyrimidine bases were separated using capillary zone electrophoresis (CZE) with direct UV detection at 254 nm as well as mass spectrometric (MS) detection using an electrospray ionization (ESI) interface. For this purpose a carrier electrolyte composition compatible with both methods of detection containing 300 mM diethylamine (DEA) was selected. Limits of detection were in the range between 0.1 and 0.3 mg l−1 and calibration plots were found to be linear over at least two orders of magnitude. The applicability of the developed method for the analysis of real samples was demonstrated for some beer samples. A series of “Lager” beer samples from different breweries in Europe as well as a number of completely different types of beers were investigated with respect to their content in the selected purine and pyrimidine bases using the developed CE method with UV detection at 254 nm.  相似文献   

18.
A novel preconcentration/separation approach, which online combined CZE with CD‐modified MEKC, was developed for simultaneous enhancing resolving power and detection sensitivity. CZE with cation‐selective exhaustive injection and transient ITP preconcentration was used as the first dimension, from which the effluent fractions were further analyzed by CD‐modified MEKC acting as the second dimension. As the key to successful integration of CZE with MEKC, a new interface was designed and electroaccumulation focusing strategy was employed to avoid analyte band diffusion at the interface. The comprehensive 2‐D system was successfully established with only one high voltage and four electrodes. The grouping of two orthogonal separation techniques, together with analytes preconcentration techniques, significantly enhanced resolution and sensitivity for 2‐D separation of cationic compounds. The resulting electrophoregram was quite different from that of either single CZE or MEKC. Up to 14 000‐ to 35 000‐fold improvement in sensitivity was obtained relative to conventional electrokinetic injection method. The limits of detection (S/N=3) were in the range of 0.03–0.1 μg/L. The number of theoretical plates was in the range of 103 000–184 000. This method was successfully applied to the analysis of trace cationic cardiovascular drugs in wastewater.  相似文献   

19.
陈星  关瑾  王慧泽  李云  史哲 《色谱》2010,28(11):1111-1114
建立了同时测定香兰素和其异构体邻位香兰素的毛细管区带电泳法(CZE)。考察了缓冲溶液的种类、浓度和pH以及分离电压等因素对分离结果的影响。在缓冲溶液为50 mmol/L硼砂-150 mmol/L磷酸氢二钠(pH 7.5)、分离电压15 kV的优化条件下,6 min内即可实现分离。香兰素和邻位香兰素在10~240 mg/L范围内线性关系良好,相关系数分别为0.9999和0.9997;方法的检出限均为1.0 mg/L (信噪比为3);样品的加标回收率为99.4%~101.2%,相对标准偏差为0.19%~0.73%。该方法操作简单、快速,已应用于实际样品的分析,并获得了令人满意的结果。  相似文献   

20.
Capillary zone electrophoresis was employed for the determination of diclofenac sodium using an end-column amperometric detection with a carbon fiber microelectrode, at a constant potential of 0.83 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 4.90 x 10(-3) mol/l Na2HPO4-3.10 x 10(-3) mol/l NaH2PO4 (pH 7.0) for the buffer solution, 10 kV for the separation voltage, 5 kV and 10 s for the injection voltage and the injection time, respectively. The limit of detection is 2.5 x 10(-6) mol/l or 5.2 fmol (S/N=2). The relative standard deviation is 0.8% for the migration time and 4.7% for the electrophoretic peak current. The method was applied to the determination of diclofenac sodium in human urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号