首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
1,2环氧丙烷(下面简写成环氧丙烷)分子中含氧三员环具有很大的张力,且杂原子氧上含有未公享的电子对,分子中存在有很强的极性共价键,使其易于发生定向开环反应,常用于制造丙二醇、缩丙二醇、甘油等,是一种重要的有机合成化工原料和合成硝酸纤维脂等高分子材料良好的低沸点溶剂.近年来还发现,在含有的1,2环氧基团的天然产品中,这一结构单元对这些天然产品的生物活性起着十分重要的作用.环氧丙烷这种特殊结构,使其电离和解离过程与其它的杂环化合物(三员环以上)和一般的链状化合物有着明显的不同.这方面的研究工作仅有文献[1,2]报导,其方法是…  相似文献   

2.
The use of isobaric tagging for relative and absolute quantification (iTRAQ) has increased dramatically over the past few years. Many factors can affect the accuracy of quantification. Some of these include the number of biological/technical replicates, sample complexity, instrumentation, method of peptide/protein identification and the statistical techniques used for data analysis. It has been observed that the low collision energies normally used in electrospray ionization quadrupole time-of-flight (ESI QTOF) can result in low iTRAQ reporter ion abundances. We used two-way analysis of variance (ANOVA) to compare the iTRAQ ratios that were generated on an ESI QTOF and a matrix-assisted laser desorption/ionization tandem time-of-flight (MALDI TOF/TOF). It appears that iTRAQ analyses performed on an ESI QTOF without any special modifications to instrumental parameters produce essentially the same protein ratios as those obtained on a MALDI TOF/TOF.  相似文献   

3.
Bacteriophage (phage) proteins have been analyzed previously with matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS). However, analysis of phage major capsid proteins (MCPs) has been limited by the ability to reproducibly generate ions from MCP monomers. While the acidic conditions of MALDI‐TOF MS sample preparation have been shown to aid in disassembly of some phage capsids, many require further treatment to successfully liberate MCP monomers. The findings presented here suggest that β‐mercaptoethanol reduction of the disulfide bonds linking phage MCPs prior to mass spectrometric analysis results in significantly increased MALDI‐TOF MS sensitivity and reproducibility of Yersinia pestis‐specific phage protein profiles. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Until now, time-of-flight (TOF) mass analysers have only been very rarely used in pesticide residue analysis (PRA) of water samples. However, the inherent characteristics of TOF MS make these analysers well-suited to this field, mainly for qualitative purposes. Thus, the high sensitivity obtained from full-scan acquisition in comparison to other MS analysers and the high resolution of TOF MS suggest its suitability for screening purposes; it also increases the multiresidue capabilities of methods based on it and decreases the chance of recording false positives. Although these characteristics can also be helpful for quantification, confirmation and elucidation, some limitations on the use of TOF for these purposes have been observed. These limitations are more noticeable when dealing with samples containing very low analyte concentrations, which is the normal situation for PRA in water. The use of hybrid quadrupole–time-of-flight instruments (QTOF) minimises the limitations of TOF, facilitating the simultaneous detection and unequivocal confirmation of pesticides found in the sample. Additionally, the acquisition of accurate product ion full-scan mass spectra can help to elucidate the structures of unknown compounds. In this paper, the potential of TOF and QTOF hyphenated to liquid chromatography for PRA in water is explored, emphasizing both the advantages and limitations of this approach for screening, quantification, confirmation and elucidation purposes. Emphasis is placed on the determination of polar pesticides and transformation products—the analytes that fit well with LC–API–(Q)TOF MS technology.  相似文献   

5.
In a previous publication a large series of proteins were identified in fetal human brain by the use of two-dimensional electrophoresis (2-DE) with subsequent matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) and MALDI-tandem time-of-flight (TOF/TOF) analysis. Further identification of many more different spots by traditional 2-DE without additional step such as narrow immobilized ph gradient (IPG) strips or prefractionation seems unlikely and we therefore decided to separate extracted brain proteins by ion-exchange chromatography using a TSK gel DEAE-5PW column followed by 2-DE of individual fractions and analysis by MALDI-TOF/TOF with LIFT technology in fetal brain of the early second trimester. About 1880 protein spots corresponding to 543 different gene products were identified. These proteins included housekeeping, signaling, cytoskeletal, metabolic, antioxidant, and neuron/synaptosomal specific proteins. Among these, 314 gene products (314/543, 57.8%), which have never been detected in traditional 2-DE of human fetal brain, were observed by this method. This updated map of fetal brain proteins may serve as data base and reference map for fetal brain proteins, and the methodology applied may be used as a valuable analytical tool for the basis of protein expressional studies in health and disease.  相似文献   

6.
金黄色葡萄球菌及其甲氧苯青霉素耐药性的MALDI-TOF MS鉴定   总被引:7,自引:1,他引:7  
用MALDI-TOS MS细菌指纹图谱鉴定细菌,建立区分金黄色葡萄球菌甲氧苯青霉素耐药株和敏感株的MALDI-TOF MS分析方法,检测了76株从临床标本中分离得到的金黄色葡萄球菌,用软件进行聚类分析,以nuc(耐热核酸酶)基因和mecA(耐药)基因聚合酶链反应(PCR)检测结果为参照,74%的菌株经MALDI-TOF MS给出了正确的鉴定结果;金黄色葡萄球菌甲氧苯青霉素耐药株和敏感株的质谱图有很大差别,各自有其特征峰;经过软件聚类分析,76株实验菌株划敏感群和耐药群;与PCR检测结果对照,有7株菌PCR检测mecA基因为阴性,而经MALDI-TOF MS鉴定为耐药株,表型鉴定表明其中有5株为敏感株;利用细菌指纹图谱和数据库检索对大多数菌株实现了正确鉴定;MALDI-TOF MS分辨率高,甚至可以区分株间的差异,实现了区分金黄色葡萄球菌甲氧苯青霉素耐药株和敏感株;结果表明MALDI-TOF MS提供了一个很有前景的鉴定细菌的快速方法。  相似文献   

7.
Liquid chromatography coupled to orthogonal acceleration time-of-flight mass spectrometry (LC/TOF) provides an attractive alternative to liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS) in the field of multiresidue analysis. The sensitivity and selectivity of LC/TOF approach those of LC/MS/MS. TOF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of commercial TOF instruments ranging from 10 000 to 18 000 full width at half maximum (FWHM) is not, however, sufficient to completely exclude the problem of isobaric interferences (co-elution of analyte ions with matrix compounds of very similar mass). Due to the required data storage capacity, TOF raw data is commonly centroided before being electronically stored. However, centroiding can lead to a loss of data quality. The co-elution of a low intensity analyte peak with an isobaric, high intensity matrix compound can cause problems. Some centroiding algorithms might not be capable of deconvoluting such partially merged signals, leading to incorrect centroids.Co-elution of isobaric compounds has been deliberately simulated by injecting diluted binary mixtures of isobaric model substances at various relative intensities. Depending on the mass differences between the two isobaric compounds and the resolution provided by the TOF instrument, significant deviations in exact mass measurements and signal intensities were observed. The extraction of a reconstructed ion chromatogram based on very narrow mass windows can even result in the complete loss of the analyte signal. Guidelines have been proposed to avoid such problems. The use of sub-2 microm HPLC packing materials is recommended to improve chromatographic resolution and to reduce the risk of co-elution. The width of the extraction mass windows for reconstructed ion chromatograms should be defined according to the resolution of the TOF instrument. Alternative approaches include the spiking of the sample with appropriate analyte concentrations. Furthermore, enhanced software, capable of deconvoluting partially merged mass peaks, may become available.  相似文献   

8.
Time-of-flight (TOF) instruments have recently gained popularity in quantitative analyses. Normally, TOF mass spectrometers are used for accurate mass measurements for empirical formula verification. However, over the past decade, they have been used quantitatively as well. Because of the fast separations and narrow peaks that result from gas chromatography separations, scanning mass spectrometers are not ideal detectors. TOF mass spectrometers, however, have the ability to collect spectra at a faster rate. Two-dimensional gas chromatography has also been introduced to further resolve peaks from complex matrices. Two-dimensional gas chromatography results in a faster separation as well as narrower peaks. This paper reviews the methods currently in the literature for the quantitation of compounds using one- and two-dimensional gas chromatography and TOF mass spectrometry detection.  相似文献   

9.
The simplicity and sensitivity of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry have increased its application in recent years. The most common method of "peptide mass fingerprint" analysis often does not provide robust identification. Additional sequence information, obtained by post-source decay or collision induced dissociation, provides additional constraints for database searches. However, de novo sequencing by mass spectrometry is not yet common practice, most likely because of the difficulties associated with the interpretation of high and low energy CID spectra. Success with this type of sequencing requires full sequence coverage and demands better quality spectra than those typically used for data base searching. In this report we show that full-length de novo sequencing is possible using MALDI TOF/TOF analysis. The interpretation of MS/MS data is facilitated by N-terminal sulfonation after protection of lysine side chains (Keough et al., Proc. Natl. Acad. Sci. U.S.A. 1999, 96, 7131-7136). Reliable de novo sequence analysis has been obtained using sub-picomol quantities of peptides and peptide sequences of up to 16 amino acid residues in length have been determined. The simple, predictable fragmentation pattern allows routine de novo interpretation, either manually or using software. Characterization of the complete primary structure of a peptide is often hindered because of differences in fragmentation efficiencies and in specific fragmentation patterns for different peptides. These differences are controlled by various structural parameters including the nature of the residues present. The influence of the presence of internal Pro, acidic and basic residues on the TOF/TOF fragmentation pattern will be discussed, both for underivatized and guanidinated/sulfonated peptides.  相似文献   

10.
A strategy for the characterization of bacterial lipoprotein-in this case Braun’s lipoprotein (an outer membrane 7-ku lipoprotein) isolated from Escherichia coli—is described by time-of-flight mass spectrometric (TOF/MS) techniques [252Cf plasma desorption (PD) TOF/MS and matrix-assisted laser desorption-ionization (MALDI) TOF/MS]. Covalent linkage of lipid at the N-terminal cysteine (posttranslationally modified to a S-[2,3-bis(acyloxy)-propyl]-N-acylcysteine) and, therefore, strict insolubility in aqueous solution constitute common features for this class of proteins. Relative molecular mass determination of the major molecular species of Braun’s lipoprotein was obtained by selection of an appropriate mixture of organic solvents compatible with matrix/support materials useful for the mass spectrometric techniques applied. Minor components of this lipoprotein that differ only in the fatty acid composition of the lipid anchor were detected by PD TOF/MS after enzymatic release of the extremely hydrophobic N-terminal amino acid followed by selective extraction with chloroform. Part of the primary sequence of this lipoprotein was confirmed based on peptide fragment ions observed in the positive ion PD mass spectra of cyanogen bromide-generated peptide fragments that had been isolated previously by reverse phase high-performance liquid chromatography (HPLC). Peptidoglycan fragments that represent the attachment sites of lipoprotein to peptidoglycan were enzymatically released, separated by reverse phase HPLC, and finally characterized by time-of-flight mass spectrometric techniques (252Cf-PD TOF/MS, MALDI TOF/MS). The results obtained with both techniques differed only in the better sensitivity obtained with MALDI TOF/MS, which consumed a factor of 100 to 1000 less material than with PD TOF/MS.  相似文献   

11.
Structure analyses of underivatized neutral lacto oligosaccharides are systematically performed by ultraviolet matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (UV-MALDI TOF MS) and UV-MALDI ion-trap time-of-flight mass spectrometry (ion-trap/TOF MS) acquired in negative-ion mode. Interestingly, their fragmentation significantly differ each other. In postsource decay (PSD) in UV-MALDI TOF MS, cross-ring cleavage at the reducing terminal predominates. On the other hand, glycosyl bond cleavage (C-type fragmentation) takes place preferentially in collision induced dissociation (CID) in UV-MALDI ion-trap/TOF MS. The cross-ring cleavage in PSD similar to that in in-source decay occurs via a prompt reaction path characteristic of the UV-MALDI process itself. The product ion spectra of UV-MALDI ion-trap/TOF MS are similar to the electrospray ionization (ESI) ion-trap or quadrupole/TOF CID product ion spectra. During ion-trap/TOF MS experiments, the deprotonated molecular ions survive for several tens of milliseconds after CID event because the high internal energy chlorinated precursor ions are cooled by collisional cooling in the ion trap. The results obtained suggest that the PSD from the chlorinated precursor ion in UV-MALDI TOF MS might proceed as a two-step reaction; in the first, a high internal energy deprotonated molecular ion is generated as a reaction intermediate during the flight in the drift tube, and in the second, the rapid decomposition from the deprotonated molecular ion takes place.  相似文献   

12.
Weak signal intensity and poor precursor ion selection are the major difficulties in tandem time-of-flight (TOF) mass spectrometry of ions generated by matrix-assisted laser desorption/ionization (MALDI). Even though the latter can be overcome in photodissociation (PD) tandem TOF mass spectrometry via ion pulse-PD laser pulse synchronization, clean monoisotopic selection of precursor ions of high m/z can often be difficult for various reasons. A considerable enhancement of post-source decay (PSD) and PD tandem mass spectra has been achieved in this work via single-ion detection and post-acquisition reduction of the spectra. Also, an algorithm has been developed to clean up isotopomeric contamination when the resolution for precursor ion selection is less than adequate. A high-quality tandem TOF mass spectrum which results from PD of virtually monoisotopic precursor ions has been obtained.  相似文献   

13.
采用同步辐射光源、飞行时间质谱和分子束方法研究了1.4-二氧六环的光电离解离过程.由光电离效率曲线得出离子产物的出现势,计算了产物的生成焓.若重分析了m/e=28,29.41等离子碎片的解离通道以及离子碎片的可能结构,提出1、4-二氧六环在光电离解离过程中发生了重排反应  相似文献   

14.
Silicon oxynitride has been used as a shallow gate oxide material for microelectronics and its thickness has been reduced over the years to only a few tens of angstroms due to device size scaling. The nitride distribution and density characteristic in the gate oxide thus becomes imperative for the devices. The shallow depth profiling capability using time‐of‐flight secondary ion mass spectrometry (TOF‐SIMS) has huge potential for the nitrogen characterization of the shallow gate oxide film. In this article, both positive and negative spectra of TOF‐SIMS on silicon oxynitride have been extensively studied and it was found that the silicon nitride clusters SixN? (x = 1–4) are able to represent the nitrogen profiles because their ion yields are high enough, especially for the low‐level nitride doping in the oxide, which is formed by the annealing of nitric oxide on SiO2/Si. The gate oxide thickness measured by the TOF‐SIMS profiling method using 18O or CsO profile calibration was found to correlate very well with transmission electron microscope measurement. The nitrogen concentration in the gate oxide measured using the TOF‐SIMS method was consistent with the results obtained using the dynamic SIMS method, which is currently applied to relatively thicker oxynitride films. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
Over the last decade, time-of-flight (TOF) instruments have increasingly been used as quantitation tools. In addition, because of their high resolving power, they can be used for verification of empirical formulas. Historically, TOF instruments have had limited quantitation capabilities because of their narrow dynamic range. However, recent advances have improved these limitations. This review covers the rationale for using TOF for LC detection, and describes the many methods currently in the literature for the quantitation of pharmaceuticals, environmental pollutants, explosives and many phytochemicals.  相似文献   

16.
On-line analysis of compounds from solution has been greatly facilitated by the advent of electrospray ionization mass spectrometry (ESI-MS). Although quadrupole mass analyzers are most commonly used with ESI at present, time-of-flight (TOF) mass spectrometers offer several potential advantages including high data acquisition rates, which are desirable for fast separation techniques. One method of coupling ESI and TOF uses an ion trap for temporary storage and accumulation of the electrosprayed ions prior to TOF mass analysis. Previous studies have not fully addressed the effects of several key variables on the analytical capabilities of this type of instrument. In this study, the characterization of an ion trap/linear TOF instrument for ESI is described. The behavior of various analytes is divided into two separate groups; each one is found to have its own optimal set of operating conditions. The reasons for the observed differences between groups are explored. Issues relevant to mass resolution, sensitivity, mass range, mass-to-charge ratio discrimination, and mass measurement accuracy are addressed. Finally, it is suggested that the analytical capability of this type of instrument could be significantly improved by changing the ion optics from the existing focusing lenses to a rf-only quadrupole lens.  相似文献   

17.
Optimization of mass spectrometers using the adaptive particle swarm algorithm (APSA) is described along with implementations for ion optical simulations and various time-of-flight (TOF) instruments. The need for in situ self optimization is addressed through discussion of the reflectron TOF mass spectrometer (RTOF) on the European Space Agency mission Rosetta. In addition, a tool for optimization of laboratory mass spectrometers is presented and tested on two different instruments. After the application of APSA optimization, a substantial increase in performance for mass spectrometers that have manually been tuned for several weeks or months is demonstrated.  相似文献   

18.
19.
Gold nanoparticles with uniform mean sizes (≈3 nm) loaded onto various supports have been prepared and studied for the oxidant-free dehydrogenation of benzyl alcohol to benzaldehyde and hydrogen. The use of hydrotalcite (HT), which possesses both strong acidity and strong basicity, provides the best catalytic performance. Au/HT catalysts with various mean Au particle sizes (2.1-21 nm) have been successfully prepared by a deposition-precipitation method under controlled conditions. Detailed catalytic reaction studies with these catalysts demonstrate that the Au-catalyzed dehydrogenation of benzyl alcohol is a structure-sensitive reaction. The turnover frequency (TOF) increases with decreasing Au mean particle size (from 12 to 2.1 nm). A steep rise in TOF occurs when the mean Au particle size becomes smaller than 4 nm. Our present work suggests that the acid-base properties of the support and the size of Au nanoparticles are two key factors controlling the alcohol dehydrogenation catalysis. A reaction mechanism is proposed to rationalize these results. It is assumed that the activation of the β-C-H bond of alcohol, which requires the coordinatively unsaturated Au atoms, is the rate-determining step.  相似文献   

20.
Cu/SiO_2 catalysts prepared by different methods have been investigated focusing on the influence of Cu~+on the catalytic performance.The composition,structure and copper valence state were characterized by means of BET,XRD,XPS,FTIR,N_2O-titration.It was found that the Cu/SiO_2 prepared by ammoniaevaporation(AE) method had much higher TOF value than that prepared by wetness-impregnation(WI)with the same THF selectivity.The higher TOF value was attributed to the coexistence of Cu~+ and Cu~0species in the activated AE-Cu/SiO_2.while only Cu° species existing in the activated Wl-Cu/SiO_2.Researches suggest that Cu~+ can adsorb and polarize the C=0 bond of DMM.It is concluded that Cu°could be the main active site and the synergistic effect between Cu~0 and Cu~+ could contribute to hydrogenation of DMM to THF.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号