首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bair MJ  Chen CL  Chiang CK  Huang MF  Hu CC  Chang HT 《Electrophoresis》2008,29(19):3964-3970
Rapid identification of Helicobacter pylori strains is of importance for diagnosis and then treatment of duodenal and gastric ulcers. We developed a CE approach for the analysis of RFLP of the PCR products of urease (UreAB) gene and flagellin A (FlaA) gene fragments. Prior to CE analysis, the 2.4-kbp UreAB and 1.5-kbp FlaA PCR products were digested with the restriction enzymes HaeIII and HhaI, respectively. The DNA fragments were then separated by CE in conjunction with laser-induced fluorescence detection using poly(ethylene oxide) in the presence of electroosmotic flow. The DNA fragments range in sizes 259-1831 bp and 12-827 bp for UreAB and FlaA restriction fragments, respectively. Of 27 samples, the CE approach provided five and ten different RFLP patterns of the HaeIII and HhaI digests. The RFLP of PCR products of the two genes allow great sensitivity of identification of H. pylori strains. When compared with slab gel electrophoresis, the present CE approach provides advantages of rapidity (within 6 min per run), simplicity, and automation. The preliminary results have shown great practicality of the CE approach for screening H. pylori strains.  相似文献   

2.
We are presenting the application of CE technique with dual‐channel LIF detection for the simultaneous separation of DNA fragments labeled with two different fluorescence dyes. The optimal conditions of the analysis were determined for the separation of amplified fragment length polymorphism (AFLP) fragments labeled with 5′‐6‐carboxyfluorescein (6‐FAM) and the DNA size standard labeled with sulfoindocyanine succinimidyl ester (Cy‐5). CE equipped with both argon ion and diode lasers is a good alternative for sequencers and might be applied in analyses of PCR products generated by various fingerprinting methods.  相似文献   

3.
With the complete sequencing of the human genome, there is a growing need for rapid, highly sensitive genetic mutation detection methods suitable for clinical implementation. DNA-based diagnostics such as single-strand conformational polymorphism (SSCP) and heteroduplex analysis (HA) are commonly used in research laboratories to screen for mutations, but the slab gel electrophoresis (SGE) format is ill-suited for routine clinical use. The translation of these assays from SGE to microfluidic chips offers significant speed, cost, and sensitivity advantages; however, numerous parameters must be optimized to provide highly sensitive mutation detection. Here we present a methodical study of system parameters including polymer matrix, wall coating, analysis temperature, and electric field strengths on the effectiveness of mutation detection by tandem SSCP/HA for DNA samples from exons 5-9 of the p53 gene. The effects of polymer matrix concentration and average molar mass were studied for linear polyacrylamide (LPA) solutions. We determined that a matrix of 8% w/v 600 kDa LPA provides the most reliable SSCP/HA mutation detection on chips. The inclusion of a small amount of the dynamic wall-coating polymer poly-N-hydroxyethylacrylamide in the matrix substantially improves the resolution of SSCP conformers and extends the coating lifetime. We investigated electrophoresis temperatures between 17 and 35 degrees C and found that the lowest temperature accessible on our chip electrophoresis system gives the best condition for high sensitivity of the tandem SSCP/HA method, especially for the SSCP conformers. Finally, the use of electrical fields between 350 and 450 V/cm provided rapid separations (<10 min) with well-resolved DNA peaks for both SSCP and HA.  相似文献   

4.
We evaluated a novel strategy for high-sensitivity DNA fragment analysis in a conventional glass double-T microfluidic chip. The microchip allows for a DNA on-channel concentration based on base stacking (BS) with a microchip capillary gel electrophoretic (MCGE) separation step in a poly(vinylpyrrolidone) (PVP) sieving matrix. Depending if low conductivity caused a neutralization reaction between the hydroxide ions and the run buffer component Tris+, the stacking of DNA fragments were processed in the microchip. Compared to a conventional MCGE separation with a normal electrokinetic injection, the peak heights of 50-2650-base pair (bp) DNA fragments on the MCGE-BS separation were increased 3.9-8.0-fold. When we applied the MCGE-BS method to the analysis of a clinical sample of bovine theileria after PCR reaction, the peak height intensity of the amplified 816-bp DNA fragment from the 18S rRNA of T. buffeli was enhanced 7.0-fold compared to that of the normal injection method.  相似文献   

5.
Long Z  Liu D  Ye N  Qin J  Lin B 《Electrophoresis》2006,27(24):4927-4934
Microfluidic devices integrating membrane-based sample preparation with electrophoretic separation are demonstrated. These multilayer devices consist of 10 nm pore diameter membranes sandwiched between two layers of PDMS substrates with embedded microchannels. Because of the membrane isolation, material exchange between two fluidic layers can be precisely controlled by applied voltages. More importantly, since only small molecules can pass through the nanopores, the integrated membrane can serve as a filter or a concentrator prior to microchip electrophoresis under different design and operation modes. As a filter, they can be used for separation and selective injection of small analytes from sample matrix. This has been effectively applied in rapid determination of reduced glutathione in human plasma and red blood cells without any off-chip deproteinization procedure. Alternatively, in the concentrator mode, they can be used for online purification and preconcentration of macromolecules, which was illustrated by removing primers and preconcentrating the product DNA from a PCR product mixture.  相似文献   

6.
A single nucleotide polymorphism (SNP) typing assay is developed and evaluated on a microfabricated capillary array electrophoresis system. Using fluorescently labeled allele-specific primers, the S65C (193A-->T) substitution associated with hereditary haemochromatosis in the HFE gene is genotyped. The covalently labeled polymerase chain reaction (PCR) products are separated on a microfabricated radial capillary array electrophoresis microplate using nondenaturing gel media in under two minutes. Detection is accomplished with a laser-excited rotary confocal scanner. The Rox-labeled A-allele specific amplicon (211 bp) is differentiated from the R110-labeled T-allele specific amplicon (201 bp) by both size and color. This study demonstrates the feasibility of using allele-specific PCR with covalently labeled primers for high speed fluorescent SNP typing on microfabricated radial capillary array electrophoresis microplates.  相似文献   

7.
Beard NP  de Mello AJ 《Electrophoresis》2002,23(11):1722-1730
A polydimethylsiloxane-glass capillary microchip is fabricated for the rapid analysis of a mixture of common biogenic amines using indirect fluorescence detection. Using a running buffer of phosphate and 2-propanol, and Rhodamine 110 as a background fluorophore, both co-ionic and counter-ionic systems are explored. Studies demonstrate the separation and analysis of cations using indirect fluorescence detection for the first time in a chip-based system. Resulting electrophoretic separations are achieved within a few tens of seconds with detection limits of approximately 6 microM. The reduced sample handling and rapid separations afforded by the coupling of indirect fluorescence detection with chip-based capillary electrophoresis provide a highly efficient method for the analysis and detection of molecules not possessing a chromophore or fluorophore. Furthermore, limits of detection are on a par with reported chip-based protocols that incorporate precolumn derivatisation with fluorescence detection. The current device circumvents lengthy sample preparation stages and therefore provides an attractive alternative technique for the analysis biogenic amines.  相似文献   

8.
Electroactive intercalators for DNA analysis on microchip electrophoresis   总被引:1,自引:0,他引:1  
Miniaturized analytical systems, especially microchip CE (MCE), are becoming a promising tool for analytical purposes including DNA analysis. These microdevices require a sensitive and miniaturizable detection system such as electrochemical detection (ED). Several electroactive DNA intercalators, including the organic dye methylene blue (MB), anthraquinone derivatives, and the metal complexes Fe(phen)3 2+ and Ru(phen)3 2+, have been tested for using in combination with thermoplastic olefin polymer of amorphous structure (Topas) CE-microchips and ED. Two end-channel approaches for integration of gold wire electrodes in CE-ED microchip were used. A 250 microm diameter gold wire was manually aligned at the outlet of the separation channel. A new approach based on a guide channel for integration of 100 and 50 microm diameter gold wire has been also developed in order to reduce the background current and the baseline noise level. Modification of gold wire electrodes has been also tested to improve the detector performance. Application of MCE-ED for ssDNA detection has been studied and demonstrated for the first time using the electroactive dye MB. Electrostatic interaction between cationic MB and anionic ssDNA was used for monitoring the DNA on microchips. Thus, reproducible calibration curves for ssDNA were obtained. This study advances the feasibility of direct DNA analysis using CE-microchip with ED.  相似文献   

9.
Wang J  Chen G  Wang M  Chatrathi MP 《The Analyst》2004,129(6):512-515
The preparation of carbon nanotube (CNT)/copper composite electrodes, based on co-mixing CNT and Cu powders within mineral oil, is described. The new composite electrode is used for improved amperometric detection of carbohydrates following their capillary electrophoresis (CE) microchip separations. The CNT/Cu composite electrode detector displays enhanced sensitivity compared to detectors based on copper or CNT alone. The marked catalytic action of the CNT/Cu composite material permits effective low potential (+0.5 V vs. Ag/AgCl) amperometric detection, and is coupled to the renewability, bulk modification and versatility advantages of composite electrodes. The CNT/Cu composite surface also leads to a greater resistance to surface fouling compared to that observed at the copper electrode. Factors affecting the electrocatalytic activity and the CE microchip detection are examined and optimized. The CNT/Cu composite electrode is also shown to be useful for the detection of amino acids as indicated from preliminary results. While the present work has focused on the enhanced CE microchip detection of carbohydrates and amino acids, the CNT/metal-composite electrode route should benefit the detection of other important groups of analytes.  相似文献   

10.
This paper describes the use of epoxy-encapsulated electrodes to integrate microchip-based electrophoresis with electrochemical detection. Devices with various electrode combinations can easily be developed. This includes a palladium decoupler with a downstream working electrode material of either gold, mercury/gold, platinum, glassy carbon, or a carbon fiber bundle. Additional device components such as the platinum wires for the electrophoresis separation and the counter electrode for detection can also be integrated into the epoxy base. The effect of the decoupler configuration was studied in terms of the separation performance, detector noise, and the ability to analyze samples of a high ionic strength. The ability of both glassy carbon and carbon fiber bundle electrodes to analyze a complex mixture was demonstrated. It was also shown that a PDMS-based valving microchip can be used along with the epoxy-embedded electrodes to integrate microdialysis sampling with microchip electrophoresis and electrochemical detection, with the microdialysis tubing also being embedded in the epoxy substrate. This approach enables one to vary the detection electrode material as desired in a manner where the electrodes can be polished and modified as is done with electrochemical flow cells used in liquid chromatography.  相似文献   

11.
A polymerase chain reaction (PCR) was developed to differentiate the thickening agents locust bean gum (LBG) and the cheaper guar gum in finished food products. Universal primers for amplification of the intergenic spacer region between trnL 3' (UAA) exon and trnF (GAA) gene in the chloroplast (cp) genome and subsequent restriction analysis were applied to differentiate guar gum and LBG. The presence of <5% (w/w) guar gum powder added to LBG powder was detectable. Based on data obtained from sequencing this intergenic spacer region, a second PCR method for the specific detection of guar gum DNA was also developed. This assay detected guar gum powder in LBG in amounts as low as 1% (w/w). Both methods successfully detected guar gum and/or LBG in ice cream stabilizers and in foodstuffs, such as dairy products, ice cream, dry seasoning mixes, a finished roasting sauce, and a fruit jelly product, but not in products with highly degraded DNA, such as tomato ketchup and sterilized chocolate cream. Both methods detected guar gum and LBG in ice cream and fresh cheese at levels <0.1%.  相似文献   

12.
We describe an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. A 300-μm-diameter platinum disc working electrode was embedded in a titanium tube which provides an adequate holding for working electrode and acts as counter electrode. We also have designed a simplified detection cell with a guide channel for the electrode. The integrated working-counter electrode can be easily aligned to the outlet of the separation channel through the guide channel. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3). The system was further applied to the determination of chlorpromazine hydrochloride in pharmaceutical formulations. The system is believed to have potential applications in pharmaceutical analysis.
Figure
We described an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3).  相似文献   

13.
Microchip CE coupled with electrochemical detection (MCE-EC) is a good method for the direct detection of many small molecule analytes because the technique is sensitive and readily miniaturized. Polymer materials are being increasingly used with MCE due to their affordability and ease of fabrication. While PDMS has become arguably the most widely used material in MCE-EC due to the simplicity of microelectrode incorporation, it suffers from a lack of separation efficiency, lower surface stability, and a tendency for analyte sorption. Other polymers, such as poly(methylmethacrylate) (PMMA) and poly(carbonate) (PC), have higher separation efficiencies but require more difficult fabrication techniques for electrode incorporation. In this report, thermoset polyester (TPE) was characterized as an alternative material for MCE-EC. TPE microchips were characterized in their native and plasma oxidized forms and after coating with polyelectrolyte multilayers (PEMs). TPE provides higher separation efficiencies when compared to PDMS microchips, while still using simple fabrication protocols. In this work, separation efficiencies as high as 295,000 N/m were seen when using TPE MCE-EC devices. Furthermore, the EOF was higher and more consistent as a function of pH for both native and plasma-treated TPE than PDMS. Finally, TPE is amenable to modification using simple PEM coatings as another way to control surface chemistry and surface charge.  相似文献   

14.
The release of cytochrome C (Cyt C) plays an important role in apoptosis. In this study, selective and sensitive detection of Cyt C based on an aptamer strategy coupled with MCE was developed. Following the binding of a specific aptamer to Cyt C, the aptamer exhibited an irregular state, reducing the binding affinity of a fluorescent probe, and thus preventing the aptamer‐Cyt C complexes from detection within the MCE. The height of the detection peak of the residual aptamer linearly decreased, and therefore, the difference in peak height of residual aptamer compared to that of the initial aptamer was used to quantify the captured protein concentration. Experimental conditions such as incubation time, pH, temperature, and ionic strength were optimized. A measurement of Cyt C concentration by MCE was achieved within 135 s, with a limit of detection as low as 0.4 nM. The proposed method has high selectivity and good stability for the detection of Cyt C. The experimental results demonstrate that this method is quick, consumes only a small quantity of sample, is highly selectivity and exhibits high sensitivity.  相似文献   

15.
A method based on microchip electrophoresis with electrochemical (EC) detection has been developed for the simultaneous determination of Yellow AB, Red 2G, Sunset Yellow, New Coccine, and Amaranth which are azo-dyes frequently added to foodstuffs. Factors affecting both separation and detection processes were examined and optimized, with best performance achieved by using a 10 mM phosphate buffer (pH 11) as BGE solution and applying a voltage of 2500 V both in the separation and in the electrokinetic injection (duration 4 s). Under these optimal conditions, the target dye analytes could be separated and detected within 300 s by applying a detection potential of -1.0 V (vs. Ag/AgCl) to the glassy carbon (GC) working electrode. The recorded peaks were characterized by a good repeatability (RSD=1.8-3.2%), high sensitivity, and a wide linear range. Detection limits of 3.8, 3.4, 3.6, 9.1, 15.1 microM were obtained for Yellow AB, Red 2G, Sunset Yellow, New Coccine, and Amaranth, respectively. Fast, sensitive, and selective response makes the new microchip protocol very attractive for the quantitative analysis of commercial soft drinks and candies.  相似文献   

16.
Jang YC  Jha SK  Chand R  Islam K  Kim YS 《Electrophoresis》2011,32(8):913-919
Detection and quantitation of nucleic acids have gained much importance in the last couple of decades, especially in the post-human genome project era. Such processes are tedious, time consuming and require expensive reagents and equipment. Therefore, in the present study, we demonstrated a simple process for the separation and analysis of small DNA fragments using capillary electrophoretic amperometric detection on an inexpensive disposable glass microchip. The device used polydimethylsiloxane engraved microchannel and Au/Ti in-channel microelectrodes for sample detection. The DNA fragments were separated under low electric field (20 V/cm) for improved detection sensitivity and to retain the biomolecules in their native conformation. With a low sample requirement (as low as 1 μL) and high reproducibility, the proposed microchip device was successful in resolution and detection of DNA fragments of various lengths.  相似文献   

17.
We present the rapid single-strand conformation polymorphism (SSCP) analysis by capillary and microchip electrophoresis to detect the mutations in K-ras gene. Parameters that might affect the analysis of mutation in K-ras gene, such as the polymer and the additive in the sieving matrix, have been studied systematically. Under the optimal conditions, the analysis of seven mutants of K-ras gene could be finished within 10 min by capillary electrophoresis (CE). Furthermore, with the wild-type gene as the inner standard, the analysis accuracy of mutations could be improved. In addition, by studying the properties of polymer solutions, the matrix suitable for microchip electrophoresis was found, and the detection of mutations in K-ras gene could be further shortened to 1 min.  相似文献   

18.
Lin CC  Lee GB  Chen SH 《Electrophoresis》2002,23(20):3550-3557
Automation of electrophoretic microchips for sequential analysis of different samples is demonstrated. This system used an autosampler, which was on-line connected to the microchip and the whole process including sample loading and injection, analysis and data acquisition as well as washing were all automated. Rhodamin B at different concentrations was first loaded into a hydrodynamic flow stream by an autosampler, delivered to the microchip, and then sequentially injected into the electrophoretic microchannel for analysis and detection. Automation was achieved by running two independent programs, one for sample loading by an autosampler and the other one for electrophoretic injection by voltage switching, on the same computer. Using this sampling chip, each loaded volume (0.2-1 microL) can be injected for dozens of electrophoretic analyses (1-10 nL for each injection). The variances caused by the external connections, which did not affect the electrophoretic analysis but would cause band broadening of the loaded sample in the hydrodynamic flow stream, were theoretically deduced. Results indicate that the dead volume (approximately 300 nL) due to the connection fitting on the chip could lead to dilution of the loaded sample by a factor of one when 0.2 microL of sample was loaded. Such a design allows sequential analysis of a series of samples while the running buffer is continuously pumped into the connection capillary as well as microchannels for washing between two loaded samples to minimize cross contamination without human intervention. Using this sampling chip, the required sample amount and handling time can be greatly reduced compared to the manual method.  相似文献   

19.
Microchip electrophoresis for the short-time analysis of amino acids in Japanese green tea was developed. The amino acids in Japanese green tea were derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F). The derivatives were filtered and directly analyzed by electrophoresis on a plastic microchip with a 31-mm long separation channel with fluorescence detection. Amino acid analysis of Japanese green tea was improved by removing polyphenols using a polyvinylpolypyrrolidone pretreatment. Elution profiles of NBD-amino acids were examined under different running buffer conditions, and the sodium dodecyl sulphate in the running buffer exhibited a dramatically high-separation efficiency of amino acids by inhibiting their adsorption on the channel walls. Under the optimized conditions (5 mM phosphate buffer (pH 5.5) containing 0.05 mM sodium dodecylsulfate as running buffer), the main amino acids contained in Japanese green tea were well separated within 2 min, and theanine (1475 mg/100 g tea leaf), Arg (408 mg/100 g tea leaf) and Gln (217 mg/100 g tea leaf) were detected in Japanese green tea.  相似文献   

20.
Microchip electrophoresis for the short-time analysis of amino sugars is described. D-Glucosamine, D-galactosamine and their reduced forms were labeled with 4-nitro-2,1,3-benzoxadiazole 7-fluoride (NBD-F) at pH 6.0 and the fluorescent derivatives were purified on an octadecyl silica (ODS) gel plate. The derivatives were analyzed by electrophoresis on a microfabricated chip with a 33 mm long separation channel with argon laser-induced fluorescence detection. Under the established conditions, these amino sugarderivatives were well separated from each other within 60 s. Amino sugars of as small an amount as 0.5 fmol could be detected with a signal-to-noise (S/N) ratio of 3, and peak response showed good linearity between at least 0.8 and 8 fmol of samples with a relative standard deviation (RSD) of ca. 4%. This method was also applied to the analysis of amino sugar composition of O-linked glycans released from bovine submaxillary mucin with alkali in the presence of borohydride. The result of amino sugar composition analysis for individual O-glycans fractionated by high-performance liquid chromatography was quite useful for their identification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号