首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The high-performance liquid chromatographic (HPLC) behaviour of two different styrene-divinyl-benzene-based reversed-phase (RP) columns was evaluated using crude acetic acid extracts from normal and diabetic human pancreata as samples. Acetic acid gradients in water and acetonitrile gradients in triethylammonium phosphate (TEAP) and trifluoroacetic acid (TFA) were used as mobile phases, and comparisons were made with a silica-based C4 column. When two different polymeric RP columns were eluted with acetic acid gradients in water, surprisingly similar HPLC profiles of the pancreatic extracts were obtained. Elution of the polymer-based columns with acetonitrile gradients in TFA or TEAP resulted in changes in the polypeptide selectivity of these columns, in parallel with that of a silica-based C4 column eluted under similar conditions, indicating the general usability of polymeric columns for RP-HPLC of peptides and proteins. The pronounced difference in composition between normal and diabetic samples, which also was demonstrated after size-exclusion chromatography (SEC) on a silica-based and an agarose-based high-performance SEC column, was found to be related to the different ischaemia times for the two types of pancreata.  相似文献   

2.
The use of a high content of acetic acid as mobile phase additive for the reversed-phase high-performance liquid chromatography (RP-HPLC) of several proteins and extracts of biological tissues was evaluated for a divinylbenzene (DVB)-based stationary phase, and the separations obtained with acetic acid gradients in acetonitrile, isopropanol or water were compared with classical polypeptide RP-HPLC on silica C4 with trifluoroacetic acid (TFA)-acetonitrile. The separation patterns for recombinant derived interleukin-1 beta (IL-1 beta) on the C4 column eluted with TFA-acetonitrile and the DVB column eluted with acetic acid-acetonitrile were similar, but only the polymeric column was able to separate the components present in an iodinated IL-1 beta preparation. Neither eluent had any harmful effect on the biological activity of IL-1 beta isolated after RP-HPLC. Several standard proteins could be separated when the polymeric column was eluted with acetic acid gradients in acetonitrile, isopropanol or water and, although the separation efficiency with acetic acid in water was lower than that in combination with classical organic modifiers, insulin, glucagon and human growth hormone (hGH) were eluted as sharp, symmetrical peaks. The recoveries of insulin and hGH were comparable for all three mobile phases (80-90%). The separation patterns obtained from a crude acetic acid extract of a normal and a diabetic, human pancreas analysed using acetic acid gradients with or without organic modifiers were found to be similar and comparable to those obtained on a silica C4 column eluted with an acetonitrile gradient in TFA. The principal differences resulted from the use of different UV wavelengths (215 nm for TFA-acetonitrile, 280 nm for acetic acid). Acetic acid extracts of recombinant derived hGH-producing Escherichia coli were separated on the DVB column eluted with an acetic acid gradient in water. Although the starting material was a highly complex mixture, the hGH isolated after this single-step purification was surprisingly pure (as judged by sodium dodecyl sulphate-polyacrylamide gel electrophoresis). Consequently several (pure) polypeptides and complex biological samples were separated on a polymeric stationary phase eluted with acetic acid gradients in water without the use of organic modifiers.  相似文献   

3.
The potential value of eight commercial available polymer-based reversed-phase (RP) columns for peptide and protein separations was evaluated using crude acetic acid extracts of normal and diabetic human pancreata and mixtures of pure polypeptides as samples. All columns were characterized with acetic acid gradients in water as mobile phase, and different chromatographic profiles were obtained depending on the type of polymer column (bare or derivatized) and the type of ligand. Some of the columns were virtually free from effects related to the polymer skeleton whereas in others the separation was influenced by both the ligand and the polymeric backbone. Two selected polymeric RP columns were, together with a silica-based C4 column, further characterized with acetonitrile gradients in trifluoroacetic acid (TFA), and the separation temperature was found to have a drastic effect on the separation efficiency for proteins with mol. wt. greater than 6000 dalton. No such effect was seen for polypeptides with mol. wt. less than 6000 dalton. Mixtures of pure peptides and proteins were separated using acetic acid gradients in water, acetonitrile or isopropanol, and normally the highest efficiency was found with the use of acetonitrile as mobile phase modifier. Isopropanol was less suitable as an organic modifier. The separation of the beta-lactoglobulin A- and B-chains may be used to give a rapid estimate of the chromatographic usability of polymer-based RP-columns for peptide and protein separations in acetic acid gradients in water and in acetonitrile gradients. Recoveries for insulin, proinsulin, growth hormone, ovalbumin and human serum albumin were measured for several polymer-based RP columns eluted with acetic acid gradients in water and with acetonitrile-based mobile phases. The highest recoveries of serum albumin and ovalbumin were found after elution with acetic acid gradients in water.  相似文献   

4.
We have developed a one-step facile, flexible and readily scalable purification method for a recombinant protein, TM 1-99 (113 amino acid residues; 12,837 Da) based on reversed-phase high-performance liquid chromatography (RP-HPLC) from an E. coli cell lysate. Following cell lysis, the cell contents were extracted with 0.1% aqueous trifluoroacetic acid (TFA), applied directly under conditions of high sample load to a narrow bore RP-HPLC C(8) column (150 mm x 2.1 mm I.D.) and eluted by a shallow gradient of acetonitrile (0.1%/min). Loads of 23 and 48 mg of lyophilized crude cell extract produced 2.4 and 4.2mg of purified product (>94% pure), respectively, at >94% recovery. Our results show the excellent potential of one-step RP-HPLC for purification of recombinant proteins from cell lysates, where high yields of purified product and greater purity are achieved compared to affinity chromatography. Such an approach was also successful in purifying just trace levels (<0.1% of total contents of crude sample) of TM 1-99 from a cell lysate.  相似文献   

5.
Two reversed-phase high-performance liquid chromatographic (RP-HPLC) systems were developed for the separation of human insulin, proinsulin and the major proinsulin intermediates. The individual components were quantified using two enzyme-linked immunosorbent assays for insulin and proinsulin immunore-active material (PIM) after (passive) evaporation of the organic modifier. Serum samples from normal subjects and patients with non-insulin-dependent diabetes mellitus were immunopurified and analysed in one of the RP-HPLC systems. The proportion of PIM relative to insulin immunoreactive material was higher in the diabetic patient compared with that in the normal subject. In both, PIM was heterogeneous, consisting of intact proinsulin and des-proinsulin intermediates.  相似文献   

6.
RP-HPLC is the main method for the analysis of alkaloids. However, peak tailing is a problem that commonly occurs in the separation of alkaloids. In order to overcome this, three kinds of RP columns were compared for the analysis of protoberberine alkaloids in Coptidis Rhizoma and Phellodendri Cortex in this work. XTerra MS C18 column was the best one which gave the best symmetry factor under the same conditions. With this column, a good separation of the crude extracts of C. Rhizoma and P. Cortex was achieved using 0.1% v/v formic acid buffer and methanol as mobile phase. At the same time, the crude extracts of C. Rhizoma and P. Cortex were analyzed by the LC-ESI-MSn and LC-atmospheric pressure chemical ionization (APCI)-MSn methods. In the analysis of HPLC-ESI/MSn, structures of five protoberberine alkaloids were elucidated, compared to authentic standards, and data from the literature. At the same time, the structure of a novel compound was elucidated. In the HPLC-APCI/ MSn analysis, there was an interesting phenomenon that the relative abundance of the ions M+ and [M + 2]+ was different for different alkaloids. The possible fragmentation pathways of protoberberine alkaloids in APCI/MS analysis were studied for the first time in the present work.  相似文献   

7.
Two methods for the determination of cloricromene acid in biological samples are described. Cloricromene acid is a catabolite of cloricromene, a coumarin derivative which is active in the cardiovascular system. After oral administration of cloricromene to a rabbit, plasma and platelets were taken at different times and cloricromene acid was then isolated by solid-phase extraction with Sep-Pak C18 cartridges using acetonitrile-tetrahydrofuran-20% aqueous acetic acid (15:11:74, v/v/v) as eluent. The analyses were performed by reversed-phase high-performance liquid chromatography (RP-HPLC) combined with fluorescence detection with excitation at 310 nm and emission at 390 nm. The limit of quantification by RP-HPLC was about 50 pg. The catabolite in the plasma was identified by continuous-flow fast atom bombardment mass spectrometry (CF-FAB-MS), also used as a complementary means of RP-HPLC determination. The results obtained by RP-HPLC and CF-FAB-MS showed good agreement.  相似文献   

8.
A small, semi-preparative C(4) RP-HPLC column was used to set up the conclusive laboratory-scale purification of Chinese hamster ovary-derived human thyrotropin (hTSH), after a preliminary concentration-purification of an extremely dilute and poorly ( approximately 0.6 microg hTSH/mL; mass fraction=0.35%) conditioned medium on a cation exchanger. Several fractions of this eluate were repeatedly injected on the semi-preparative column, obtaining, in a single run (<1h chromatographic time), a concentrated pool ( approximately 1.2 mg/mL) of highly purified hTSH that could be further concentrated to >3 mg/mL and then efficiently lyophilized. The overall recovery in the rapid RP-HPLC purification step, including concentration and lyophilization, was of the order of 80%. The final product, when tested via a precise, single-dose in vivo bioassay, confirmed that it did not suffer any loss of bioactivity. This same methodology can be easily adapted to the small-scale purification of other recombinant products, even when obtained from genetically modified organisms at extremely low concentrations and mass fractions.  相似文献   

9.
Oral delivery of insulin is convenient and physiologically desirable in the treatment of diabetes. However, this route of administration has presented substantial challenges as insulin is degraded enzymatically in the gut, resulting in low bioavailability. We have developed a conjugated insulin product (IN-105) that has high bioavailability and is currently undergoing clinical trials for the treatment of diabetes. A process for the manufacture of IN-105 was developed. Initially, recombinant human insulin was conjugated covalently with a monodisperse, short-chain methoxypolyethylene glycol derivative. The desired product, IN-105, was purified from its closely related species using RP-HPLC and cation exchange chromatography to a purity of 98.5%. The elution pool from cation exchange chromatography was crystallized and lyophilized into the dry active pharmaceutical ingredient.  相似文献   

10.
Elution of a commercial sample of bovine serum albumin (BSA) in a reversed-phase (RP) HPLC system at room temperature gives a distorted peak. If a shallow gradient is used during elution a split peak is observed. The nature of the several parts of this multiple peak is studied using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), size-exclusion chromatography (SEC), amino acid analysis, re-elution in RP-HPLC of collected fractions, capillary electrophoresis (CE), and matrix assisted laser desorption ionization-mass spectrometry (MALDI-MS). This study demonstrates that the split peak of BSA observed in these chromatographic conditions is due to the monomer, dimer and other aggregates existing in the commercial sample of the BSA used. Moreover, it is proved that typical RP-chromatographic conditions do not cause aggregation of BSA.  相似文献   

11.
M. Gu  Z. -G. Su  J. -C. Janson 《Chromatographia》2006,64(11-12):701-704
Resveratrol and polydatin (piceid), the major active components of the traditional Chinese medicinal herb Polygonum cuspidatum (Sieb. & Zucc.), have been separated and purified from crude root extracts in one step by isocratic hydrogen bond adsorption chromatography on cross-linked 12% agarose (Superose? 12 HR 10/30). Separation was achieved by step-wise elution with mobile phases composed of mixtures of ethanol and acetic acid: 0–75 mL, 10% ethanol, 10% acetic acid; 75–150 mL, 20% ethanol, 20% acetic acid; 150–250 mL, 30% ethanol, 30% acetic acid. At a sample load of 40 mg crude extract dissolved in 0.5 mL mobile phase (corresponding to a load of 1.7 mg mL?1 gel) a resveratrol purity of about 96% with a recovery of 61% was obtained by proper peak cutting.  相似文献   

12.
Foetal rat pancreatic rudiments explanted on day 14 of gestation were grown in organ culture in medium enriched with amino acids. The size of the insulin granules was increased, resulting in an insulin granule volume fraction greater than the volume fraction measured in pancreas grown in vivo. The pancreas was extracted and the insulin compared. Serial dilution curves of extracts of adult pancreas and pancreas grown in vitro are parallel in the insulin radioimmunoassay, whereas extracts of pancreas of foetus developing in utero appear immunologically different. Adult and foetal rat insulin (in utero) were purified using chromatography on OPTI UP C12, cellulose thin-layer chromatography plates, cellulose acetate foil electrophoresis and finally high-performance liquid chromatography. The ratio of insulin I to insulin II was found to be 1.5 for the adult and 2.7 for the foetus. These results show that there is an unequal expression of the two non-allelic genes controlling insulin biosynthesis in foetal and adult rat pancreas.  相似文献   

13.
A simple and fast method was developed using RP-HPLC for separation and quantitative determination of vanillin and related phenolic compounds in ethanolic extract of pods of Vanilla planifolia. Ten phenolic compounds, namely 4-hydroxybenzyl alcohol, vanillyl alcohol, 3,4-dihydroxybenzaldehyde, 4-hydroxybenzoic acid, vanillic acid, 4-hydroxybenzaldehyde, vanillin, p-coumaric acid, ferulic acid, and piperonal were quantitatively determined using ACN, methanol, and 0.2% acetic acid in water as a mobile phase with a gradient elution mode. The method showed good linearity, high precision, and good recovery of compounds of interest. The present method would be useful for analytical research and for routine analysis of vanilla extracts for their quality control.  相似文献   

14.
An interface has been developed which permits the on-line coupling of size-exclusion chromatography in tetrahydrofuran with aqueous reversed-phase high-performance liquid chromatography. The interface isolates the required size exclusion chromatography fraction and dilutes it with water to ensure reconcentration of analytes on the reversed-phase column prior to gradient elution. Operational parameters and the influence of analyte polarity have been examined in detail. A predictive system is presented for determining the applicability of the system to any analyte, based on solute retention times on an ODS phase eluted with a methanol-water gradient. The method is illustrated with examples of direct analyses of crude lipid extracts from a snack product for 2,6-di-tert.-4-methylphenol and from chocolate for dibutyl phthalate. Detection limits of ca. 0.5 mg/kg have been achieved.  相似文献   

15.
The combination of sol–gel methodology with rapid prototyping (RP) produces functionalized 3D structures with potential applications in various fields. However, this combination has been little explored. In this paper, we used the sol–gel method to deposit vanadium isopropoxide onto polyamide (PA12) constructed by RP and pretreated with acetic acid, to obtain a functionalized substrate with new thermal, physical, and chemical properties. Vanadium isopropoxide (one, five, or ten layers) was deposited onto the PA12 piece by dip-coating. We characterized the coated PA12 by thermal analyses, X-ray diffraction, and infrared spectroscopy, which revealed that V=O and Si–O–Si groups exist on the PA12 surface. PA12 coating with vanadium isopropoxide enhanced the decomposition temperature. Differential scanning calorimetry revealed increased fusion and decomposition enthalpy as a function of the PA12 coating. Therefore, deposition of vanadium isopropoxide onto PA12 pretreated with acetic acid improves the thermal stability of PA12 prepared by RP.  相似文献   

16.
Abstract

Top round, bovine semimembranosus and adductor muscle was selected as a model for isolation of presumptive, low molecular mass (Mr) flavor peptides. The isolation and purification of these peptides (<5,000 Mr) from ‘cooked’ and ‘cooked-stored-recooked’ meat was developed by combining various chromatographic techniques. Peptide samples were initially made by preparing acetic acid extracts of meat followed by the removal of organic soluble lipids and carbohydrates by phase partition extraction. The lipid-free extracted material was subsequently subjected to size exclusion chromatography using Sephadex G-25 resulting in two major polypeptide groups with Mr of 1500 to 3000. This material was now available for further purification by both semipreparative and analytical reverse phase (RP) - high performance liquid chromatography (HPLC) for separation of hydrophilic and hydrophobic peptides. Separation of the peptides into these two groups is particularly important since the perception of sweet taste is usually associated with hydrophilic peptides while bitter (and often sour) taste is associated with hydrophobic peptides. Semipreparative RP-HPLC of peptides from the low Mr material revealed highly significant differences in the hydropilic and hydrophobic peptide composition of ‘cooked’ versus ‘cooked-stored-recooked’ samples i.e., the former appeared to have equal amounts of the two classes of peptides while the latter appeared to contain predominantly hydrophobic peptides. Peptides prepared semipreparatively were readily available for further examination by analytical RP-HPLC and analyzed by diode array detection. The latter method revealed major differences in the hydrophobic peptide components found in the two meat groups.  相似文献   

17.
建立了反相高效液相色谱((RP-HPLC))同时测定化妆品中7种萘二酚类物质的分析方法。膏霜类、乳液类和水类样品用95%(v/v)乙醇提取,粉类样品用95%乙醇-0.1%乙酸(3:2, v/v)溶液提取,经离心、过滤后,用C18柱,以甲醇-0.1%乙酸溶液为流动相梯度洗脱分离,使用二极管阵列检测器检测,以保留时间定性,并以紫外吸收光谱图辅助定性,外标法定量。结果表明,萘二酚类物质在线性范围内线性关系良好,相关系数均不低于0.999 0,方法的定量限(以信噪比为10计)为0.5~1.2 mg/kg,添加水平为5.0~50 mg/kg时回收率为84.0%~102%,相对标准偏差(n=6)为1.3%~5.7%。该法前处理简单、回收率高、精密度好,适用于非蜡基类化妆品中萘二酚类物质的测定。  相似文献   

18.
Two factors were separated from rat liver particulate fraction treated with insulin, one of them having a stimulating effect on low-Km adenosine 3',5' cyclic monophosphate (cAMP) phosphodiesterase activity of crude microsomal fraction (P-2 fraction) and the other having an inhibiting effect on the activity of low-Km cAMP phosphodiesterase solubilized with 0.3% Brij 58 from P-2 fraction. Trypsin and heat treatments had essentially no effect on these two factors. The stimulating factor did not significantly change the apparent Km value of enzyme in P-2 fraction but increased the maximal velocity of the reaction. The inhibiting factor raised the Km value of solubilized enzyme without affecting the maximal velocity of the reaction. The stimulating factor level in diabetic rat was larger than that in normal rat while the inhibiting factor level in diabetic rat was smaller than that in normal rat. Possible participation of both factors in insulin action is discussed.  相似文献   

19.
The structure and adsorption properties (with respect to water vapor and nickel cations) of chitosan samples dehydrated by either lyophilization after precipitation with NaOH or Na2CO3 or drying in air are investigated. IR spectroscopy and X-ray diffraction data testify that the lyophilization causes both changes in the conformation of chitosan macromolecules and a substantial rise in the crystallinity of the polymer to compare with the air dried one. Chitosan structure ordering resultant from the lyophilization noticeably increases its sorption ability with respect to both water vapor and nickel cations. For example, the sorption capacity of the lyophilized chitosan with respect to nickel cations is as high as 4.5 mmol/g and, thus, is threefold higher than that of air-dried chitosan. The comparative analysis of water adsorption isotherms in the region of low degrees of filling indicates that chitosan structure ordering resultant from the lyophilization changes the number and the energy of primary adsorption sites.  相似文献   

20.
《Electroanalysis》2017,29(2):358-366
Flavonoids are natural phenolic derivatives that, in low concentration, can provide health benefits by preventing biomolecules (proteins, nucleic acids, lipids, sugars) oxidative damage through free radical mediated reactions. The flavonoids, in selected Mediterranean seasonal fruits: apricot, sour cherry, plum, pomegranate, date, prickly pear (cactus fruit), and nectarine, by RP‐HPLC, coupled with photodiode array and electrochemical detectors, after microwave‐ultrasound assisted extraction, using flavonoid standards, were detected. The total antioxidant capacity in the lyophilized fruit extracts, by differential pulse voltammetry, (electrochemical index‐EI), integrated peak area, and chronoamperometry, was evaluated. In the lyophilized fruit extracts, and the catechin standard, the free radical scavenger efficient concentration (EC50), using DPPH. assay, was determined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号