首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive method for the determination of alkylphenols in water samples has been developed using gas chromatography-mass spectrometry. Alkylphenols were determined after the extractive derivatization with pentafluoropyridine. The derivatization of alkylphenols efficiently proceeded to give the corresponding 4-tetrafluoropyridyl derivatives under the biphasic reaction system. The derivatization conditions including the phase-transfer catalyst, the amount of pentafluoropyridine, the reaction time, the concentration of NaOH and organic solvent were optimized. On the mass spectra of these derivatives, intense specific ion peaks were observed: m/z 256 for 4-n-alkylphenols and m/z 284 for 4-tert.-alkylphenols. Calibration curves were linear in the range of 20-1000 ng/l (200-10,000 ng/l for nonylphenol), and the detection limits varied between 6.93 and 15.7 ng/l (85.2 ng/l for nonylphenol). The average recoveries of the alkylphenols in a fortified river water sample (100 ng/l except for nonylphenol: 1000 ng/l) ranged from 91.1 to 112%. The relative standard deviations were found to be between 5.6 and 16%. This method was successfully applied to the determination of alkylphenols in river water.  相似文献   

2.
A simple method was developed to detect four stilbene-type disulfonate and one distyrylbiphenyl-type fluorescent whitening agents (FWAs) in household laundry detergents and surface waters by ion-pair high-performance liquid chromatography. The FWA concentrations in detergents were measured directly. The contents of FWAs in water samples were extracted by solid-phase extraction (C18-SPE) with ion-pairing reagent, and were then determined by an isocratic ion-pair chromatography (IPC) using a C18 column, applying tetrabutylammonium hydrogensulfate (TBA) as the ion-pairing reagent in mobile phase, and equipped with fluorescence detection. Water samples at various pH conditions for SPE were evaluated. Experimental results indicate that the proposed method is precise and sensitive in analyzing FWAs, and enables quantitation of 0.01-0.1 microg/l in 100 ml water samples. The recovery rates of FWAs in spiked water samples were between 73 and 89%, and the precision (RSD) ranged from 2.6 to 8.9%. Over 7200 microg/g of 4,4'-bis(2-sulfostryl)-biphenyl (DSBP) and 2320 microg/g of 4,4'-bis[(4-anilino-6-morpholino-1,3,5-triazine-2-yl)-amino]stilbene-2,2'-disulfonate (DAS1) were detected in household laundry detergents. Trace amounts of DSBP were detected in surface water samples ranging from 0.2 to 3.7 microg/l.  相似文献   

3.
A simple, low cost, fast and sensitive method is reported for the determination of the four endocrine disrupting chemicals (EDCs) 4-tert-butylphenol, 4-tert-octylphenol, bisphenol A and 17β-estradiol using pentafluoropyridine as the derivatizing reagent. These EDCs were determined by simultaneous extraction and derivatization in a solid phase analytical derivatization (SPAD) technique without the aid of any phase transfer catalyst (PTC) or an ion-pair mechanism. Recoveries of analytes as their tetrafluoropyridyl derivatives from water ranged from 71% for 4-tert-butylphenol to 106% for 17β-estradiol; from urine they ranged from 61% for 17β-estradiol to 91% for 4-tert-octylphenol; and from humic acids solution the ranged from 59% for 17β-estradiol to 104% for 4-tert-octylphenol in humic acid solutions. Calibration curves were constructed from a matrix of human male urine in the range 1-40 ng/mL and had coefficients of correlation greater than 0.99. For 4-tert-butylphenol, bisphenol A and 17β-estradiol the limits of quantitation were 5 ng/mL and for 4-tert-octylphenol it was 1 ng/mL. This method was applied to determine EDCs and detected 4-tert-octylphenol, bisphenol A and 17β-estradiol in concentrations comparable to those found in the literature. The method offers advantages in speed of analysis, reduced reagent and specificity of derivatization.  相似文献   

4.
This study presents a modified method to analyze nonylphenol polyethoxycarboxylates (NPEC) and their related metabolites (carboxyalkylphenol ethoxycarboxylates (CNPEC)) in water samples. The method involves extraction of samples by a graphitized carbon black (GCB) cartridge, and direct derivatization in the GC injection-port using a large-volume (10-20 microl) direct sample introduction (DSI) device with tetraalkylammonium (TAA) salts. The analytes are identified and quantitated by ion-trap GC-MS. The large-volume DSI injection-port derivatization technique provides sensitivity, fast and reproducible results for NPEC and their metabolites, to quantitation at 0.1 microg/l in 200 ml of water samples. The retention effect of TAA salts in the injection-port is not detected. In addition, the significant [M-29]+ ions and molecular ions of butylated NPEC and CNPEC residues are observed. Recovery of NP1EC in spiked water samples ranges from 90 to 108%. Moreover, relative standard deviations of replicate analyses ranges from 1 to 9%. However, unsatisfactory on-line derivatization of CNPEC residues is observed. This finding maybe owing to their lesser dissociation with the ion-pair reagent in chloroform.  相似文献   

5.
Ching-Lin Hsu 《Talanta》2009,80(2):1025-4425
A rapid and environmental-friendly injection-port derivatization with gas chromatography-mass spectrometry (GC-MS) method was developed to determine selected low-molecular weight (LMW) dicarboxylic acids (from C2 to C10) in atmospheric aerosol samples. The parameters related to the derivatization process (i.e., type of ion-pair reagent, injection-port temperature and concentration of ion-pair reagent) were optimized. Tetrabutylammonium hydroxide (TBA-OH) 20 mM in methanol gave excellent yield for di-butyl ester dicarboxylate derivatives at injection-port temperature at 300 °C. Solid-phase extraction (SPE) method instead of rotary evaporation was used to concentrate analytes from filter extracts. The recovery from filter extracts ranged from 78 to 95% with relative standard deviation (RSD) less than 12%. Limits of quantitation (LOQs) ranged from 25 to 250 pg/m3. The concentrations of di-carboxylated C2-C5 and total C6-C10 in particles of atmospheric aerosols ranged from 91.9 to 240, 11.3 to 56.7, 9.2 to 49.2, 8.7 to 35.3 and n.d. to 37.8 ng/m3, respectively. Oxalic acid (C2) was the dominant LMW-dicarboxylic acids detected in aerosol samples. The quantitative results were comparable to the results obtained by the off-line derivatization.  相似文献   

6.
气相色谱-质谱法测定水体中5种典型有机紫外防晒剂   总被引:1,自引:0,他引:1  
丁怡然  黄云  赵婷婷  蔡倩  罗玉  黄斌  张榆霞  潘学军 《色谱》2014,32(6):629-634
建立了水体中5种典型有机紫外防晒剂甲氧基肉桂酸乙基己酯(ethylhexyl methoxycinnamate,EHMC)、二苯酮-3(benzophenone-3,BP-3)、4-甲基苄亚基樟脑(4-methylbenzylidene camphor,4-MBC)、奥克立林(octocrylene,OC)和胡莫柳酯(homosalate,HMS)的气相色谱-质谱检测方法。对HMS、BP-3衍生化条件进行了系统的优化。以100 μL双(三甲基硅烷基)三氟乙酰胺(N,O-bis(trimethylsilyl) trifluoroacetamide,BSTFA)为衍生化试剂,在100 ℃下反应100 min。水样固相萃取选用Oasis HLB萃取柱(0.5 g),洗脱溶剂为乙酸乙酯-二氯甲烷(1:1,v/v),水样pH 3~5。该方法对5种化合物的检出限范围为0.5~1.2 ng/L,定量限范围为1.4~4.0 ng/L。最佳实验条件下,加标水样回收率为87.85%~102.34%,相对标准偏差(n=3)均小于5%。该方法成功地应用于昆明市第一污水厂进出口水样中目标物质的分析。  相似文献   

7.
An efficient method for the simultaneous determination of the degradation products of nonylphenol polyethoxylates (NPnEOs, n = number of ethoxy units), i.e., nonylphenol (NP), NPnEOs (n = 1-3), nonylphenoxy carboxylic acids (NPnECs, n = 1-2, number of ethoxy units plus an acetate) and their halogenated derivatives (XNP, XNP1EO and XNP1EC; X = Br or Cl), in water samples were developed. After trimethylsilylation with N,O-bis(trimethysilyl)acetamide, all the analytes were determined by gas chromatography-tandem mass spectrometry (GC-MS-MS) with electron ionization (EI). The ion peaks of [M - 85]+ of the derivatives were selected as precursor ions and their product ions showing the highest intensities were used for the quantitative analysis. The instrumental detection limits were in the range from 2.1 to 11 pg. The recoveries of the analytes from the water samples were optimized by using solid-phase extraction (SPE). The deuterated reagents of octylphenol, octylphenol monoethoxylate and octylphenoxyacetic acid were used as the surrogates. The method detection limits (500 ml water sample) using C18 SPE were from 2.5 to 18 ng/l. The recoveries from spiked pure water and the environmental water samples were greater than 78%. The method was successfully applied to environmental samples. Remarkably, the concentrations of the halogenated compounds (CINP, CINP1EO and BrNP1EO) were detected at the hundreds of ng/l levels in the Neya river.  相似文献   

8.
A simple, highly selective and sensitive method for the determination of 14 representative alkylphenols from phenol (C0) to nonylphenol (C9) in produced water is described. Solid-phase extraction (SPE) by anion-exchange sorbent is used to extract alkylphenols from produced water. The samples are then derivatised by pentafluorobenzoyl chloride and analysed on GC-MS (negative ion chemical ionisation, NCI). The derivatisation procedure has been validated by means of two-level factorial design (2(7-4)) experiments. Quantification is done with isotope dilution of five internal standards of different alkyl chain length. The detection limits were at low ng/l levels. A comparison with GC-MS analysis of non-derivatised alkylphenol samples revealed the advantage of derivatisation as described in the method.  相似文献   

9.
Alonso MC  Barceló D 《The Analyst》2002,127(4):472-479
Seven benzene- and naphthalenesulfonates (3-nitrobenzenesulfonate, 4-methylbenzenesulfonate, 1-hydroxy-4-naphthalenesulfonate, 1-amino-7-naphthalenesulfonate, 4-chlorobenzenesulfonate, 1-naphthalenesulfonate and 2-naphthalenesulfonate) were studied. A rapid method for quantifying aromatic sulfonated compounds from waste water samples was developed. This method consists in on-line in-field sampling and monitoring based on ion-pair solid-phase extraction with PLRP-S sorbent, using the new programmable field extraction system and ion-pair liquid chromatography with UV diode-array and electrospray mass spectrometry. Limits of detection for the studied compounds, using the SIM acquisition mode, ranged from 0.01 to 0.33 ng ml(-1). The influence of the aqueous matrix on the on-line SPE was checked by spiking ground and waste waters. Recoveries varied from 70 to 99% when 10 ml of water sample were enriched. The method was applied to the analysis of some environmental sewage samples. This study confirmed that high concentration levels of aromatic sulfonated compounds can be found in sewage samples. In addition, the stability of the seven studied sulfonated benzene and naphthalene compounds was investigated using on-line polymeric SPE pre-columns, based on the styrene-divinylbenzene polymer PLRP-S. Different storage conditions were tested to carry out the stability survey, which included storage at room temperature, at 4 degrees C and at -20 degrees C, during a period of up to 2 weeks. This study showed that the stability of aromatic sulfonic acids on disposable on-line SPE polymeric pre-columns is related to temperature and that the target compounds are more stable at lower temperatures.  相似文献   

10.
Haloacetic acids (HAAs) were determined in different water samples by a new, fast and simple analysis method based on enrichment of 50-ml water samples at pH 1.8 by solid-phase extraction (SPE) followed by liquid chromatography (LC) separation and electrospray ionization mass spectrometric detection in the negative ionization mode. Deprotonated (M-H)-haloacetates and decarboxylated (M-COOH)- ions were detected. Different polymeric SPE sorbents were tested, and LiChrolut EN was found to be the best material for the extraction. Complete LC separation of all compounds could only be achieved by ion-pair chromatography using triethylamine as volatile ion-pairing reagent. The detection limits were in the low microg/l range. High microg/l concentration levels for the chlorinated and brominated haloacetates were found in drinking water from a drinking water treatment plant in Barcelona, and the corresponding tap water. In swimming pool water samples from Catalonia mg/l levels and in surface river water from Portugal microg/l values were detected. These results confirm other recent reports on the ubiquitous occurrence of HAAs in aqueous environments.  相似文献   

11.
The combined gas chromatographic determination of a number of hydroxyl-group containing endocrine disruptors, including 4-octylphenol, 4-nonylphenol, 2,4-dichlorophenol, pentachlorophenol, 4-tert.-butylbenzoic acid, bisphenol-A, 17beta-estradiol and 17alpha-ethynylestradiol, was investigated. Derivatization, required for sensitive determination of these compounds, was carried out using N-methyl-N-(tert.-butyldimethyltrifluoroacetamide). A number of parameters affecting the derivatization reaction, like temperature, time, matrix, solvent, and amount of reagent were studied in detail. Quantitative yields were obtained for real-life extracts after optimization, but the hormones were only mono-substituted. Both solid-phase extraction (SPE) and liquid-liquid extraction were studied as extraction methods, with emphasis on SPE material and effect of pH. Recoveries and RSD for analysis of surface water samples were 58-106 and 6-16% (n=4), respectively, when using SPE, and 109-117 and 6-14% (n=6) when using liquid-liquid extraction. The method developed allows routine analysis of surface water for traces of endocrine disruptors. The limits of detection of were 4-6 ng/l but higher for the hormones.  相似文献   

12.
An automated method based on the on-line coupling of anion-exchange solid-phase extraction (SPE) and cation-exchange liquid chromatography followed by post-column derivatization and fluorescence detection has been developed for the trace level determination of glyphosate and its primary conversion product aminomethyl phosphonic acid (AMPA) in water. PRP-X100 poly(styrene-divinylbenzene)-trimethylammonium anion-exchange cartridges (20 x 2 mm, 10 microm) were selected for the SPE of glyphosate and AMPA. The ionic compounds present in the samples strongly influenced the extraction of both analytes; however, when an on-line ion-exchange clean-up step was introduced before sample SPE, the problem was largely solved. By processing 100-ml samples detection limits better than 0.02 microg/l for glyphosate and 0.1 microg/l for AMPA were achieved in river water. Both analytes were unstable in solution and the approach of storing samples on the PRP-X100 SPE cartridges was evaluated for a period of 1 month under three different storage conditions (deep freeze, refrigeration and 20 degrees C).  相似文献   

13.
固相萃取柱上衍生气相色谱-质谱法测定水中烷基酚   总被引:7,自引:0,他引:7  
以烷基酚(APs)主要降解产物辛基酚(4-t-OP)、壬基酚(4-n-NP)为研究对象,建立了固相萃取(SPE)柱上衍生化、气相色谱-质谱(GC-MS)法测定水中APs的分析方法。以C18柱为固相萃取柱、N,O-(三甲基硅)三氟乙酰胺(BSTFA)为硅烷化试剂,设计五因素四水平正交实验L16(45),对衍生化影响因素、衍生化溶剂、衍生化时间以及SPE主要影响因素pH值、盐度和洗脱剂进行优化;在优化条件下,方法的回收率(高于80%)和重现性(RSD低于10%)结果令人满意,4-t-OP和4-n-NP的仪器检出限分别为3.35ng/L和6.38ng/L。采用建立的方法,回收率略高于传统的SPE萃取衍生法,具有有机溶剂用量少,方法简单快速、灵敏度高的特点,适用于河水和海水中痕量烷基酚的快速测定。  相似文献   

14.
An ion-pair reversed-phase high-performance liquid chromatographic method with UV-visible spectrophotometric detection is proposed for the simultaneous determination of manganese, chromium and molybdenum. By using a C18-bonded silica column, 4-(2-pyridylazo)resorcinol (PAR) chelates of Mn(II), Cr(VI) and Mo(VI) were successfully separated and accurately determined at 480 nm. Tetrabutylammonium bromide (TBAB) was used as the ion-pair reagent. Effects of pH, the buffer system, the concentration of buffer, the color developing time, the concentration of chelating reagent and the ion-pair reagent on the resolution were investigated. PAR chelates were eluted within 20 min at a flow-rate of 1.0 ml min(-1) with a methanol aqueous mobile phase, CH3OH-water (20:80, v/v), containing 1.0 x 10(-3) mol l(-1) acetate buffer (pH 6.5), 1.8 x 10(-2) mol l(-1) TBAB and 2.0 x 10(-4) mol l(-1) PAR. The feasibility of the proposed method was verified with the standard reference materials of nickel-based alloys. The nickel-based alloys were analyzed chromatographically after ammonium pretreatment. Under the optimum conditions, the detection limits for the chelates of Mn(II), Cr(VI) and Mo(VI) were 0.31, 4.2 and 4.6 ng with 100 microl injection, respectively. The accuracy of the proposed chromatographic method was verified by good agreement between the values obtained by this method and certified values.  相似文献   

15.
A newly developed method for determining three phenoxy acids and one carbamate herbicide in water and soil samples using gas chromatography with mass spectrometric detection is developed. Phenoxy acids are derivatized through a condensation reaction with a suitable aromatic amine. 1,1-Carbonyldiimidazole is used as a condensation reagent. Derivatization conditions are optimized with respect to the amount of analyte, amine, solvent, and derivatization reagent. The optimum derivatization yield is accomplished in acetonitrile. 4-Methoxy aniline is used as a derivatizing agent. Obtained derivatives are stable indefinitely. Enhancement in sensitivity is achieved by using the single-ion monitoring mass spectrometric mode. The effectiveness of the developed method is tested by determining investigated compounds in water and soil samples. Analytes are concentrated from water samples using liquid-phase extraction and solid-phase extraction. Soil samples are extracted using methanol. Detection limits of 1.00, 50.00, 100.00, and 1.00 ng/mL are obtained for 2-(1-methylethoxy)phenyl methylcarbamate (Baygon), 2-(3-chlorophenoxy)-propionic acid (Cloprop), 2,4,5-trichlorophenoxyacetic acid, and 4-(2,4-dichlorophenoxy)butyric acid, respectively. LPE for spiked water samples yields recoveries in the range of 60.6-95.7%, with relative standard deviation (RSD) values of 1.07-7.85% using single component calibration curves. Recoveries of 44.8-275.5%, with RSD values ranging from 1.43% to 8.61% were obtained using a mixed component calibration curves. SPE from water samples and soil samples showed low recoveries. The reason is attributed to the weak sorption capabilities of soil and Al(2)O(3).  相似文献   

16.
A sensitive and rapid derivatization method for the simultaneous determination of 1,3-dichloro-2-propanol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in water samples has been developed. The aim was to research the optimal conditions of the derivatization process for two selected reagents. A central composite design was used to determine the influence of derivatization time, derivatization temperature and reagent volume. A global desirability function was applied for multi-response optimization. The analysis was performed by gas chromatography-mass spectrometry. During the optimization of the extraction procedure, four different types of solid-phase extraction (SPE) columns were tested. It was demonstrated that the Oasis HLB cartridge produced the best recoveries of the target analytes. The pH value and the salinity were investigated using a Doehlert design. The best results for the SPE of both analytes were obtained with 1.5 g of NaCl and pH 6. The proposed method provides high sensitivity, good linearity (R(2)≥0.999) and repeatability (relative standard deviations % between 2.9 and 3.4%). Limits of detection and quantification were in the range of 1.4-11.2 ng/mL and 4.8-34.5 ng/mL, respectively. Recoveries obtained for water samples were ca. 100% for 1,3-DCP and 3-MCPD. The method has been successfully applied to the analysis of different samples including commercially bottled water, an influent and effluent sewage.  相似文献   

17.
An integrated analytical method for the simultaneous determination of 4-n-nonylphenol (4-n-NP), nonylphenol monoethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), bisphenol A (BPA) and triclosan (TCS) in wastewater (dissolved and particulate phase) and sewage sludge was developed based on gas chromatography-mass spectrometry. Chromatographic analysis was achieved after derivatization with bis(trimethylsilyl)trifluoroacetamide (BSTFA). Extraction from water samples was performed by solid-phase extraction (SPE). The optimization of SPE procedure included the type of sorbent and the type of the organic solvent used for the elution. Referred to solid samples, the target compounds were extracted by sonication. In this case the optimization of the extraction procedure included the variation of the amount of the extracted biomass, the duration and the temperature of sonication and the type of the extraction organic solvent. The developed extraction procedures resulted in good repeatability and reproducibility with relative standard deviations (RSDs) less than 13% for all the tested compounds for both types of samples. Satisfactory recoveries were obtained (>60%) for all the compounds in both liquid and solid samples, except for 4-n-NP, which gave recoveries up to 35% in wastewater samples and up to 63% in sludge samples. The limits of detection (LODs) of the target compounds varied from 0.03 (4-n-NP) to 0.41 microg l(-1) (NP2EO) and from 0.04 (4-n-NP) to 0.96 microg kg(-1) (NP2EO) for liquid and solid samples, respectively. The developed methods were successfully applied to the analysis of the target compounds in real samples.  相似文献   

18.
为实现小体积环境水样中酚类化合物的准确、快速、高灵敏测定,通过分散液液微萃取(DLLME)和荧光衍生化的结合,建立了高效液相色谱-荧光检测(HPLC-FLD)双酚A、壬基酚、辛基酚和对特辛基酚的分析方法。考察并优化了DLLME和衍生化条件,结果表明,最优的DLLME条件为萃取剂氯仿用量70μL,分散剂乙腈用量400μL,漩涡振荡3 min,高速离心2 min。以2-[2-(7 H-二苯并[a,g]咔唑-乙氧基)]-乙基氯甲酸酯(DBCEC-Cl)为柱前衍生试剂,在pH10.5的Na2CO3-NaHCO3缓冲液/乙腈溶液、50℃下衍生反应3 min得到稳定的衍生产物,于10min内实现了4种酚衍生物的分离。方法的检出限为0.9~1.6 ng/L,定量限为3.8~7.1 ng/L,具有良好的线性、精密度和回收率,与以往报道的方法相比具有一定的优势和实用性,可用于造纸厂废水、湖水、生活废水、自来水中4种酚类内分泌干扰物的测定。  相似文献   

19.
A direct solid-phase microextraction (SPME) procedure has been developed and applied for the simultaneous determination of nonylphenol, nonylphenol mono- and diethoxylates and their brominated derivatives in raw and treated water at low microg l(-1) concentrations. Several parameters affecting the SPME procedure, such as extraction mode (headspace or direct-SPME), selection of the SPME coating, extraction time, addition of organic modifiers such as methanol and temperature were optimized. The divinylbenzene-carboxen-polydimethylsiloxane fiber was the most appropriate one for the determination of nonylphenol ethoxylates (NPEOs) and bromononylphenol ethoxylates (BrNPEOs) by SPME-GC-MS. The optimized method was linear over the range studied (0.11-2.5 microg l(-1)) and showed good precision, with RSD values between 4 and 15% and detection limits ranging from 30 to 150 ng l(-1) depending on the compound. The SPME procedure was compared with a solid-phase extraction-GC-MS method (C18 cartridge) for the analysis of NPEO and BrNPEOs in water samples. There was good agreement between the results from both methods but the SPME procedure showed some advantages such as lower detection limits, a shorter analysis time and the avoidance of organic solvents. The optimized SPME method was applied to determine nonylphenol and brominated metabolites in raw and treated water of Barcelona (NE Spain).  相似文献   

20.
Solid-phase extraction (SPE) and solid-phase microextraction (SPME) were evaluated for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples using gas chromatography coupled to negative chemical ionisation mass spectrometry (GC-NCI-MS). For SPE optimisation, four commercially available SPE cartridges were tested and several SPE parameters, such as the elution solvent, elution volume and breakthrough volume were studied. The best results were obtained with Varian Bond Elut-C18. In order to achieve a high selectivity in the determination of SCCPs, GC-NCI-MS was used. Quality parameters of the optimised SPE and SPME procedures were determined, and the best results were obtained for the SPE/GC-NCI-MS method with LODs of 5 and 20 ng l(-1) for tap and river water, respectively. This method was successfully applied to the analysis of SCCPs in river water samples at concentrations below the microg l(-1) level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号