首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
X Z Wu  S K Sze  J Pawliszyn 《Electrophoresis》2001,22(18):3968-3971
Miniaturization of whole-column imaging capillary isoelectric focusing (CIEF) is discussed. A 1.2 cm capillary was used as a separation column for CIEF. The experimental results for the analysis of two pI markers and the protein myoglobin showed that good CIEF separation results could be obtained. Secondly, a light-emitting diode (LED) was used as the light source for the whole-column absorbance imaging detection. The focusing of both the pI markers and myoglobin were observed with the LED light source. The whole-column imaging CIEF instrument was simplified and miniaturized by the use of the LED. Further developments are also discussed.  相似文献   

2.
Wu XZ  Zhang LH  Onoda K 《Electrophoresis》2005,26(3):563-570
Carrier ampholyte-free isoelectric focusing (IEF) sample injection (concentration) for capillary electrophoresis (CE) is realized in a single capillary. A short section of porous capillary wall was made near the injection end of a capillary by HF etching. In the etching process, an electric voltage was applied across the etching capillary wall and electric current was monitored. When an electric current through the etching capillary was observed, the capillary wall became porous. The etched part was fixed in a vial, where NaOH solution with a certain concentration was added during the sample injection. The whole capillary was filled with pH 3.0 running buffer. The inlet end vial was filled with protein sample dissolved in the running buffer. An electric voltage was applied across the inlet end vial and etched porous wall. A neutralization reaction occurs at the boundary (interface) of the fronts of H+ and OH-. A pH step or sharp pH gradient exists across the boundary. When positive protein ions electromigrate to the boundary from the sample vial, they are isoelectricelly focused at points corresponding to their pH. After a certain period of concentration, a high voltage is applied across the whole capillary and a conventional CE is followed. An over 100-fold concentration factor has been easily obtained for three model proteins (bovine serum albumin, lysozyme, ribonuclease A). Furthermore, the IEF sample concentration and its dynamics have been visually observed with the whole-column imaging technique. Its merits and remaining problem have been discussed, too.  相似文献   

3.
Fan L  Cheng Y  Li Y  Chen H  Chen X  Hu Z 《Electrophoresis》2005,26(22):4345-4354
A simple, effective, and continuous online concentration method for the sensitive detection of alkaloids applying CE-flow injection analysis with head-column field-amplified sample stacking was developed. A series of samples was continuously introduced into the capillary by electrokinetic means without interrupting the high voltage. A short water plug was introduced by the EOF at the capillary inlet end prior to sample introduction. Under optimum conditions, 15-fold improvement in concentration sensitivity was achieved, giving an LOD of about 0.67 and 0.73 microg/mL for ephedrine (E) and pseudoephedrine (PE), respectively. The separation could be achieved within 4 min and sample throughput rate could reach up to 7/h. The repeatability (defined as RSD) was 3.62, 1.51% with peak area evaluation and 1.30, 2.58% with peak height evaluation for E and PE, respectively. This method has been successfully applied to the analysis of commercial pharmaceutical preparations containing E and PE, and the recoveries were 92.3-102.4%.  相似文献   

4.
Poor sensitivity and low phase ratio are the main drawbacks of open tubular capillary electrochromatography (OTCEC). The poor sensitivity results from the use of narrow bore size capillary, whereas the low phase ratio, which limits the separation capability, is caused by the limited surface area of conventional capillary. Two strategies may be useful to overcome these disadvantages. First, an extended light path (ELP) capillary, which has a bubble cell at the detection point, is used to improve the sensitivity. Secondly, an etched capillary of a 1,000-fold increased surface area is used to enhance the phase ratio. In this work, use of an ELP capillary and an etched capillary in OTCEC was evaluated with a chiral stationary phase of avidin prepared with the physical adsorption method. With a 20 microm I.D. ELP capillary with a 150 microm bubble cell, the peak height was enhanced by 4-10-fold and the corrected peak area was increased by 12-fold relative to a 20 microm I.D. conventional capillary. However, the peak efficiency and resolution decreased noticeably. The phase ratio on the etched capillary was slightly enhanced, by a factor of 1.64 relative to an unetched capillary. Consequently, the separation capability was slightly improved. The increase in the phase ratio was much lower than that expected from the increase in surface area, the reason for which is probably the reduced density of surface silanol group and the generation of nitrogen-containing groups due to the etching process.  相似文献   

5.
The gain in separation efficiency for protein digests using long monolithic columns has been evaluated for a LC‐MS system with capillary monolithic columns of different lengths (150 and 750 mm). A mixture of BSA, α‐casein and β‐casein tryptic digests was used as a test sample. Peak capacity and productivity (peak capacity per unit time) were determined from base peak chromatograms and MS/MS data were used for protein identification by MASCOT database searching. Peak capacity and protein identification scores were higher for the long column. Analyses with similar gradient slope for the two columns produced ratios of the peak capacities that were slightly higher than the expected value of the square root of the column length ratio. Peak capacity ratios varied from 2.7 to 4.0 for four different gradient slopes, while protein identification scores were 2–4 times higher for the long column. Similar values were obtained for the productivity of both columns and the highest productivity was obtained at gradient times of 45 and 75 min for the short and long column, respectively. The use of long monolithic columns improves peptide separation and increases reliability of protein identification for complex digests, especially if longer gradients are chosen.  相似文献   

6.
In this paper, we develope the new standardization methods to eliminate the influence in capillary electrophoresis (CE). The markers were used to determine the basis position and then correct the data of sample by the migration time of standard sample, and make the migration time of samples consistent with the standard sample by the criterion of the marker. The problem of time transition was corrected in this way. Then according to the peak height or peak area of the marker in the sample (peak height was used here) compared with the standard sample, the sample data was zoomed appropriately. The absorbance error was made to be correct. The wavelet de-noise method was also used to make the data smooth and get a good baseline.  相似文献   

7.
In this paper, we develope the new standardization methods to eliminate the influence in capillary electrophoresis (CE). The markers were used to determine the basis position and then correct the data of sample by the migration time of standard sample, and make the migration time of samples consistent with the standard sample by the criterion of the marker. The problem of time transition was corrected in this way. Then according to the peak height or peak area of the marker in the sample (peak height was used here) compared with the standard sample, the sample data was zoomed appropriately. The absorbance error was made to be correct. The wavelet de-noise method was also used to make the data smooth and get a good baseline.  相似文献   

8.
A capillary electrophoresis method for the analysis of intact heparin was developed using a phosphate buffer and a fused silica capillary. Operational parameters such as pH and concentration of the running buffer were investigated. The short end injection configuration permitted a gain on peak efficiency, on the analysis time and on the repeatability of both migration times and peak areas, through a reduction of the migration distance. Moreover, the beneficial effect of the presence of sodium chloride in the heparin sample on the peak efficiency was demonstrated and the influence of the salts on the conformation of the heparin was discussed. The optimized method (short end injection configuration, 50mM phosphate buffer pH 3, heparin sample prepared in 10 g/L NaCl solution) was validated in terms of linearity, reproducibility and specificity according to ICH requirements.  相似文献   

9.
田苗苗  杨丽 《色谱》2020,38(10):1143-1153
毛细管电泳技术具有操作简单、样品消耗量少、分离效率高和分析速度快等优势,不仅是一种高效的分离分析技术,而且已经发展成为在线酶分析和酶抑制研究的强有力工具。酶反应全程的实时在线监测,可以实现酶反应动力学过程的高时间分辨精确检测,以更准确地获得反应机制和反应速率常数,有助于更好地了解酶反应机制,从而更全面深入地认识酶在生物代谢中的功能。此外,准确、快速的在线酶抑制剂高通量筛选方法的发展,对加快酶抑制类药物的研发以及疾病的临床诊断亦具有重要意义。电泳媒介微分析法(EMMA)和固定化酶微反应器(IMER)是毛细管电泳酶分析技术中常用的在线分析方法。这两种在线酶分析法的进样方式通常为流体动力学进样和电动进样,无法实现酶反应过程中的无干扰序列进样分析。近年来,基于快速序列进样的毛细管电泳序列分析技术已经发展成为在线酶分析的另一种强有力手段,以实现高时间分辨和高通量的酶分析在线检测。该文从快速序列进样的角度,综述了近年来毛细管电泳序列分析技术在线酶分析的研究进展,并着重介绍了各种序列进样方法及其在酶反应和酶抑制反应中的应用,包括光快门进样、流动门进样、毛细管对接的二维扩散进样、流动注射进样、液滴微流...  相似文献   

10.
The study of alternative and novel techniques for altering selectivity and enhancing sensitivity as well as injection and detection protocols are important in the ongoing development of capillary electroseparation protocols. Some recent research from our laboratory in these fields is presented and discussed in this review. To improve sensitivity an off-line sample enrichment technique utilising solvent evaporation in a levitated drop or an on-line solid-phase extraction protocol was used. The selectivity was tuned by the use of protein gels or molecularly imprinted polymer mediated capillary electrochromatography. Furthermore, a picolitre droplet injection method is described as well as a detection protocol based on laser-induced fluorescence imaging.  相似文献   

11.
Cao W  Liu J  Yang X  Wang E 《Electrophoresis》2002,23(21):3683-3691
A new end-column electrochemiluminescence (ECL) detection technique coupling to capillary electrophoresis (CE) is characterized. A 300 microm diameter Pt working electrode was used to directly couple with a 75 microm inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy) 3 2+ showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy) 3 2+ in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 microm capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 220-260 microm. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 microm capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 x 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 x 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-8) mol/L.  相似文献   

12.
Liu YM  Cheng JK 《Electrophoresis》2002,23(4):556-558
Field-amplified sample injection of copper(II) was investigated using capillary electrophoresis with chemiluminescence detection. The sensitivity of copper(II) has been improved markedly by the field-amplified sample injection technique and the detection limit reaches 2 x 10(-11) M. By injection of a short plug of water before sample introduction, the sensitivity can be further improved 5-fold and the detection limit reaches 4 x 10(-12) M. The relative standard deviations (n = 6) of the migration time and the peak height are 0.61% and 4.7% at 1.0 x 10(-9) M Cu(II), respectively. Parameters affecting the field-amplified sample injection, such as separation voltage and concentration of electrophoretic buffer, have been investigated.  相似文献   

13.
A novel mode of affinity chromatography (AC) based on an open tubular capillary column (OTAC) is demonstrated. The OTAC column is prepared by immobilizing Cibacron blue F3GA onto the inner surface of a 50-microm-i.d. capillary column. The AC experiment is performed on a capillary electrophoresis instrument by using its pressure system as the driving force. Bovine serum albumin and lysozyme (Lys) are successfully separated with stepwise gradient elution. The relative standard deviation (RSD) for the elution time of the retained Lys is 0.08%, and good repeatability of its peak area and peak height with an RSD value lower than 2.12% for 10 consecutive runs is observed. The loading capacity and detection limit for the retained Lys are approximately 36 ng and 8.6 ng, respectively. It is also found that the amount of protein adsorbed is unaffected by the flow rate of the loading buffer, and OTAC can be used for the fast determination of biopolymers. Some of the advantages of OTAC over conventional modes of open tubular capillary liquid chromatography are that the detection sensitivity and loading capacity of a sample can be greatly improved, because the relatively large inner diameter of the capillary can be adopted and the whole capillary column can be used to adsorb the solute in OTAC.  相似文献   

14.
Biosynthetic human Growth Hormone (B-hGH) is a protein comprising 191 amino acids. The molecular weight is 22,125 and the isoelectric point is close to pH 5. Due to the ready availability of closely related analogues B-hGH was used as a model protein thus allowing for the demonstration and evaluation of the high resolution capability of high performance capillary electrophoresis (HPCE). The same apparatus was used throughout the experiments and an optimum signal-to-noise ratio was found at 200 nm. Linearity was observed between peak area, retention time and the hGH concentration or sample introduction time. Baseline separation of hGH, desamido hGH and didesamido hGH was obtained. Examples showing analysis with 1 million theoretical plates per meter, high speed separation, simultaneous analysis of multiple samples, sample stacking, hGH tryptic digest, and hGH lysate are reported. The use of electrophoretic velocities instead of apparent velocities for peak identification is illustrated.  相似文献   

15.
Chemiluminescence detection was used in capillary electrophoresis integrated on a microchip. Quartz microchips have two main channels and four reservoirs. Dansyl-lysine and -glycine were separated and detected with bis[(2-(3,6,9-trioxadecanyloxycarbony)-4-nitrophenyl]oxalate as peroxyoxalate chemiluminescent reagent. These dansyl amino acids came into contact with the chemiluminescence reagent to produce visible light at the interface between the separation channel and chemiluminescence reagent-containing reservoir. The detection limit (S/N = 3) for dansyl-lysine was 1 x 10(-5) M, which corresponded to the very small mass detection limit of ca. 0.4 fmol. However, the concentration sensitivity in the present system was approximately two orders of magnitude lower than that in the conventional capillary electrophoresis-chemiluminescence detection system. The relative standard deviations of migration time and peak height for dansyl-lysine were 4.2 and 4.5%, respectively. A channel conditioning before every run and an appropriate control of voltages were needed for the reproducible results. The present system had advantages in rapid separation time (within 40 s), small (several 10 pI) and accurate sample injection method using a cross-shaped injector, and simplification and miniaturization of the detection device.  相似文献   

16.
Yassine MM  Lucy CA 《Electrophoresis》2006,27(15):3066-3074
Preparative capillary zone electrophoresis separations of cytochrome c from bovine and horse heart are performed efficiently in a surfactant-coated capillary. The surfactant, dimethylditetradecylammonium bromide (2C(14)DAB), effectively eliminated protein adsorption from the capillary surface, such that symmetrical peaks with efficiencies of 0.7 million plates/m were observed in 50-microm id capillaries when low concentrations of protein were injected. At protein concentrations greater than 1 g/L, electromigration dispersion became the dominant source of band broadening and the peak shape distorted to triangular fronting. Matching of the mobility of the buffer co-ion to that of the cytochrome c resulted in dramatic improvements in the efficiency and peak shape. Using 100 mM bis(2-hydroxyethyl)imino-tris(hydroxymethyl)methane phosphate buffer at pH 7.0 with a 100-microm id capillary, the maximum sample loading capacity in a single run was 160 pmol (2.0 microg) of each protein.  相似文献   

17.
K A Assi  B J Clark  K D Altria 《Electrophoresis》1999,20(13):2723-2725
The use of a chirally selective capillary electrophoresis method is reported for the enantioselective purity determination of propranolol drug substance. The method employed a combination of both charged and neutral cyclodextrin. An internally coated capillary was used to suppress electroosmotic flow and potential peak tailing. The method was capable of monitoring below 0.1% m/m of the undesired impurity. Acceptable validation data was also obtained for recovery, linearity, and for both short and long-term injection precision.  相似文献   

18.
The phenomenon of electrophoresis in free solution has been studied theoretically down to the molecular level for decades. In addition, intermolecular photo-induced proton transfer reactions, which occur in a wide class of molecules (phenols and aminoarenes) as well as proteins (green fluorescent protein), were also studied extensively. However, the study of the effect of light-induced electrophoretic mobility changes of the analytes in electrophoresis was begun only recently. In the present work, capillary zone electrophoresis was chosen as the environment to measure the magnitude of these electrophoretic mobility shifts induced by light. Background electrolytes (running electrolytes) with high refractive indices were developed, allowing the capillary to work like an optical fiber. The experimental conditions for obtaining stable coupling and guided laser light along the liquid core are discussed. Experimental evidence of band compression is observed, leading to a solitary wave behavior of the analyte band (2-naphthol). These solitary waves result from competition between thermal diffusion (dispersion mechanism) and a nonlinear (band compression) effect due to the combined electrophoresis phenomenon and absorption of guided light by the molecules of the band (which are subjected to a "reversible intermolecular proton transfer reaction" as one of their decay routes). The possibilities of applying this effect to different methods and techniques are also discussed.  相似文献   

19.
A method based on the presence of a dynamic pH junction within the capillary to induce band narrowing for enhanced detection sensitivity for some peptides is presented. This technique is predicated on a sharp reduction in an analyte's migration velocity following a reversal of its electrophoretic direction from the acidic sample zone to the basic BGS zone. Larger-than-usual injection volumes of samples in relatively high-conductivity matrices were enabled, without degrading peak shape, resolution and efficiency. The size of the original sample plug was reduced by as much as 38-fold, and improvement in detector response in terms of peak height by as much as 124-fold was obtained. The effects of pH and concentration of the sample matrix, and the length of sample injection on the efficiency of the technique are discussed.  相似文献   

20.
Tu C  Zhu L  Ang CH  Lee HK 《Electrophoresis》2003,24(12-13):2188-2192
Large-volume sample stacking (LVSS) is an effective on-capillary sample concentration method in capillary zone electrophoresis, which can be applied to the sample in a low-conductivity matrix. NaOH solution is commonly used to back-extract acidic compounds from organic solvent in sample pretreatment. The effect of NaOH as sample matrix on LVSS of haloacetic acids was investigated in this study. It was found that the presence of NaOH in sample did not compromise, but rather help the sample stacking performance if a low pH background electrolyte (BGE) was used. The sensitivity enhancement factor was higher than the case when sample was dissolved in pure water or diluted BGE. Compared with conventional injection (0.4% capillary volume), 97-120-fold sensitivity enhancement in terms of peak height was obtained without deterioration of separation with an injection amount equal to 20% of the capillary volume. This method was applied to determine haloacetic acids in tap water by combination with liquid-liquid extraction and back-extraction into NaOH solution. Limits of detection at sub-ppb levels were obtained for real samples with direct UV detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号