首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Novel PVC membrane (PME) and coated graphite (CGE) Cu2+‐selective electrodes based on 5,6,7,8,9,10‐hexahydro‐2H‐1,13,4,7,10‐benzodioxatriazacyclopentadecine‐3,11(4H,12H)‐dione are prepared. The electrodes reveal a Nernstian behavior over wide Cu2+ ion concentration ranges (1.0×10?7–1.0×10?1 M for PME and 1.0×10?8–1.0×10?1 M for CGE) with very low limits of detection (7.8×10?8 M for PME and 9.1×10?9 M for CGE). The potentiometric responses are independent of the pH of the test solutions in the pH range 2.7–6.2. The proposed electrodes possess very good selectivities for Cu2+ over a wide variety of the cations including alkali, alkaline earth, transitions and heavy metal ions. The practical utility of the proposed electrodes have been demonstrated by their use in the study of interactions between copper ions and human growth hormone (hGH) in biological systems, potentiometric titration of copper with EDTA and determination of copper content of a sheep blood serum sample and some other real samples.  相似文献   

2.
New polymeric membrane (PME) and coated graphite (CGE) samarium(III)-selective electrodes were prepared based on isopropyl 2-[(isopropoxycarbothioyl) disulfanyl]ethanethioate as a suitable neutral ionophore. The electrodes exhibit Nernstian slopes for Sm3+ ions over wide concentration ranges (1.0×10−5 to 1.0×10−1 M for PME and 1.0×10−6 to 1.0×10−1 M for CGE). The PME and CGE have limits of detection of 3.1×10−6 and 5.0×10−7 M, respectively, and response times of about 20 s. The potentiometric responses are independent of the pH of the test solution in the pH range 4.0-7.0. The proposed electrodes revealed good selectivities over a wide variety of other cations including alkali, alkaline earth, transition and heavy metal ions. The electrodes were successfully applied to the recovery of Sm3+ ion from tap water samples and also, as an indicator electrode, in potentiometric titration of samarium(III) ions.  相似文献   

3.
A ruthenium(II) complex [Ru(PPh3)2(pytsc)2] {Hpytsc = pyridine‐2‐carbaldehydethiosemicarbazone, (C5H5N)C2(H)=N3‐N2(H)‐C1(=S)N1H} has been used as an ion carrier for the selective determination of silver(I) ions in solution. Silver(I) ion‐selective coated graphite based (CGE) and PVC polymeric membrane based (PME) electrodes exhibit Nernstian slope for silver(I) ions over a wide concentration range from 1.0 × 10−1 M to 5.0 × 10−6 M (with CGE) and 1.0 × 10−1 M to 2.0 × 10−5 M (with PME). The working pH range of these electrodes has been found to be from 1.2 to 7.2 for CGE and 2.2 to 6.5 for PME. The proposed CGE sensor exhibits better analytical features like sensitivity and selectivity towards different secondary ions in comparison to the corresponding PME with no interference from mercury(II) ions . These electrodes also act as indicator electrodes in potentiometric titration and have been successfully used for the determination of silver content in solution of real samples (1 gm dissolved in 100 mL of dilute nitric acid) such as silver ornaments and thin silver foils. Silver content determined by the use of ion selective electrode was found to vary in the concentration range from 1.20 x 10−2 M to 7.45 x 10−2 M and results were found to be comparable with those obtained from the traditional volumetric method of analysis. It is the first report of a metal‐ligand complex used as an ion carrier in ion selective electrode, which is selective for a metal ion other than the one used in the complex.  相似文献   

4.
A highly selective PVC membrane electrode based on a cerium-salen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common organic and inorganic anions. The proposed electrode exhibits a near-Nernstian behavior over a wide concentration range (5.0 x 10(-2) - 8.0 x 10(-6) M) with a slope of 57.5 mV per decade, and a detection limit of 6.0 x 10(-6) M. The electrode has a very fast response time and can be used in the pH range of 3.0 - 1 1.0. It was applied, as an indicator electrode, in potentiometric titration of Ag+ ions.  相似文献   

5.
Novel polymeric membrane electrode (PME) and coated graphite electrode (CGE) for nickel ion were prepared based on 2,9-(2-methoxyaniline)2-4,11-Me2-[14]-1,4,8,11-tetraene-1,5,8,12-N4 as a suitable neutral ionophore. The addition of lipophilic anion excluder (NaTPB) and various plasticizers viz o-nitrophenyloctylether (o-NPOE), dioctylphthalate (DOP), dibutylphthalate (DBP), 1-chloronaphthalene (CN) and tri-n-butylphosphate (TBP) have found to improve the performance of the sensors. The best performance was obtained for the membrane sensor having a composition of I:NaTPB:TBP:PVC in the ratio 6:4:100:90 (w/w; mg). The electrodes exhibit Nernstian slopes for Ni2+ ions over wide concentration ranges of 4.6 × 10?7–1.0 × 10?1 M for PME and 7.7 × 10?8–1.0 × 10?1 M for CGE with limits of detection of 2.7 × 10?7 M for PME and 3.7 × 10?8 M for CGE. The response time for PME and CGE was found to be 10 and 8 s respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0–8.0. The proposed electrodes revealed good selectivities over a wide variety of other cations including alkali, alkaline earth, transition and heavy metal ions. The coated graphite electrode was used as an indicator electrode in the potentiometric titration of nickel ion with EDTA and in direct determination in different fruit juices and wine samples.  相似文献   

6.
A new solvent polymeric membrane (PME) and coated graphite (CGE) electrodes based on 3-amino-2-mercapto-3H-quinazolin-4-one as a suitable carrier for La(III) ion are described. The sensors exhibited a Nernstian response for La(III) ion over a wide concentration range (3.0 × 10?7 to 1.0 × 10?1 M for PME and 1.0 × 10?7 to 1.0 × 10?1 M for CGE) with a slope of 20.1 ± 0.3 (PME) and 23.4 ± 0.4 (CGE) mV decade?1. The lower detection limits by PME and CGE were 2.0 × 10?7 and 7.1 × 10?8 M, respectively. The potentiometric response of the proposed electrodes was independent of the pH of the test solution in the pH range 3.0–9.0 with a fast response time (<10 s). The applications of prepared sensors were demonstrated in the determination of lanthanum ions in spiked water sample and also utilized for indirect determination of fluoride content of two mouth wash preparation samples.  相似文献   

7.
Mercury ion-selective electrodes (ISEs) were prepared with a polymeric membrane based on heterocyclic systems: 2-methylsulfanyl-4-(4-nitro-phenyl)-l-p-tolyl-1H-imidazole (I) and 2,4-diphenyl-l-p-tolyl-1H-imidazole (II) as the ionophores. Several ISEs were conditioned and tested for the selection of common ions. The electrodes based on these ionophores showed a good potentiometric response for Hg2+ ions over a wide concentration range of 5.0 x 10(5-) - 1.0 x 10(-1)M with near-Nernstian slopes. Stable potentiometric signals were obtained within a short time period of 20 s. The detection limits, the working pH range of the electrodes were 1.0 x 10(-5) M and 1.6-4.4 respectively. The electrodes showed better selectivity for Hg2+ ions over many of the alkali, alkaline-earth and heavy metal ions. Also sharp end points were obtained when these sensors were used as indicator electrodes for the potentiometric titration of Hg2+ ions with iodide ions.  相似文献   

8.
A coated-wire ion-selective electrode (CWISE), based on a Schiff base as a neutral carrier, was successfully developed for the detection of Pb(II) in aqueous solution. CWISE exhibited a linear response with a Nernstian slope of 29.4 +/- 0.5 mV/decade within the concentration range of 1.0 x 10(-5) - 1.0 x 10(-1) M lead ion. CWISE has shown detection limits of 5.0 x 10(-6) M. The electrode exhibited good selectivity over a number of alkali, alkaline earth, transition and heavy metal ions. This sensor yielded a steady potential within 10 to 20 s at a linear dynamic range. The electrode was suitable for use in aqueous solutions in a pH range of 2.0 to 5.0. Applications of this electrode for the determination of lead in real samples and as indicator electrode for potentiometric titration of Pb2+ ion using K2CrO4 are reported.  相似文献   

9.
Gholivand MB  Nozari N 《Talanta》2001,54(4):597-602
Poly(vinyl chloride) membrane electrode, that is highly selective and sensitive to Cu(II) ions, was developed by using 2,2'-dithiodianiline and dibutyl phthalate as carrier and plasticizer, respectively. The electrode exhibits good potentiometric response for Cu(II) over a wide concentration range (5.0x10(-2)-7.0x10(-7) mol l(-1)) with Nernstian slope of 30+/-1 mV per decade. The response time of the electrode is 10 s and it has been used for a period of one month and exhibits good selectivity towards Cu(2+) in comparison to alkali, alkaline earth, transition and heavy metal ions, with no interference caused by Pb(2+), Cd(2+) and Fe(+2) which are known to interfere with many other copper electrodes.  相似文献   

10.
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x 10(-7) M. The response time for the electrode is less than 30 s and the electrode can be used for more than 2 months with less than a 2 mV observed divergence in a potentials. The proposed electrode exhibits very good selectivity for mercury(II) ions over many cations in a wide pH range (pH 1 - 4). The electrode was also applied to the determination of a mercury(II) ion in vegetables and in Azolla filiculoides.  相似文献   

11.
《Electroanalysis》2004,16(16):1336-1342
The construction, performance characteristics, and application of polymeric membrane (PME) and coated graphite (CGE) thiocyanate‐selective electrodes are reported. The electrodes were prepared by incorporating the complex [Cu(L)](NO3)2 (L=4,7‐bis(3‐aminopropyl)‐1‐thia‐4,7‐diazacyclononane) into a plasiticized poly(vinyl chloride) membrane. The influence of membrane composition, pH of test solution, and foreign ions were investigated. The electrodes reveal Nernstian behavior over a wide SCN? ion concentration range (1.0×10?6–1.0×10?1 M for PME and 5.0×10?7–1.0×10?2 M for CGE) and show fast dynamic response times of 15 s and lower. The proposed sensors show high selectivity towards thiocyanate over several common organic and inorganic anions. They were successfully applied to the direct determination of thiocyanate in urine and saliva of smokers and nonsmokers, and as an indicator electrode in titration of Ag+ ions with thiocyanate.  相似文献   

12.
A sulfate ion-selective PVC membrane sensor based on 4-(4-bromophenyl)-2,6-diphenylpyrilium perchlorate (BDPP) as a novel sensing material is successfully developed. The electrode shows a good selectivity for sulfate ion with respect to common organic and inorganic anions. The sensor exhibits a good linear response with slope of -28.9+/-0.5 mV per decade over the concentration range of 1.0x10(-6)-1.0x10(-2) M, and a detection limit of 8.0x10(-7) M of SO(4)(2-) ions. The electrode response is independent of pH in the range of 4.0-9.0. The proposed sensor was applied as an indicator electrode in potentiometric titration of sulfate and barium ions, and to the determination of zinc in zinc sulfate tablets.  相似文献   

13.
The potentiometric response of a carbon paste electrode modified with silica sol-gel and mercaptosuccinic acid (MSA) in the presence and absence of gold nano-particles was studied. The results showed that the electrode with gold nano-particles was responded to Al(3+) ions as a hard metal ion. On the other hand, the electrode without gold nano-particles was responded to copper ions as a soft metal ion. The electrodes without and with gold nano-particles exhibits a Nernstian slope of 29.1 and 19.2 mV decade(-1) for copper and aluminum ions over a wide concentration range of 4.3×10(-7)-1.0×10(-2) and 4.5×10(-7)-1.6×10(-3) mol L(-1), respectively. The detection limits of electrodes were 4.0×10(-7) and 1.6×10(-7) mol L(-1) for copper and aluminum ions, respectively.  相似文献   

14.
The potentiometric response characteristics of cesium ion selective PVC membrane electrode employing calix[4]crown ether-ester as an ionophore were investigated. The electrode exhibit a good response for cesium ion over wide concentration range of 5.0x10(-6)-1.0x10(-1) M with a Nernstian slope of 59 mV per decade. The detection limit of electrode is 5.0x10(-6) M. The electrode was found to have selectivity for cesium ion over alkali, alkaline and transition metals. The response time of the electrode is less than 20 s and can be used for more than 4 months without observing any divergence in potentiometric response. The electrode response was stable over wide pH range.  相似文献   

15.
Zhang ZR  Yu RQ 《Talanta》1994,41(2):327-333
Four macrocyclic polyether derivatives of o-phenanthroline were synthesized and used as neutral carriers for preparing poly(vinyl chloride) (PVC) membrane electrodes to sense primary amine species. The potentiometric response characteristics of the electrodes prepared were investigated. The electrode sensitive to benzyl amine as model analyte showed a linear response range of 8.0 x 10(-6)-0.1 mol/l with a detection limit of 8.9 x 10(-7) mol/l and a slope of 56.5 mV/decade. The linear potentiometric response of the mexiletine-sensitive electrode was 4.7 x 10(-6)-0.1 mol/l, and the detection limit was 5.0 x 10(-7)1 mol/l with a slope of 59.0 mV/decade. The transfer behavior of amines and ammonium ions through an organic phase was investigated by means of the bulk liquid membrane transport experiment. The effects of pH, counter anions and other factors on the transfer of the amine and ammonium species were studied. The mass transfer rates of the test species facilitated by macrocyclic polyether derivatives of o-phenanthroline were determined and the following sequence was found: benzyl amine > ethyl amine > tetramethyl ammonium > triethyl amine > diethyl amine > K(+) > ammonium > Na(+) > Ca(2+) > Mg(2+). This was exactly the potentiometric selectivity sequence of the membrane electrodes prepared by using these carriers. The mechanism of transfer of benzyl amine through a membrane phase induced by the carriers has been elucidated on the basis of experimental observations.  相似文献   

16.
《Analytical letters》2012,45(13):2611-2629
ABSTRACT

New potentiometric membranesensorsresponsive to Pb(II) have been developed. The membrane sensors are based on three different 9, 10-anthraquinone derivatives. The electrode based on 1, 4-bis (prop-21-enyloxy)-9, 10-anthraquinone exhibits a good Nernstian response for Pb(II) ions over a wide concentration range (2.5×10?6 - 1.0×10?2 M) with a slope of 29.8 mV decade?1. Detection limit is 1.5×10?6 M. The response time of the sensor is 15s and the useful working pH range is 4.7-6.8. The membrane can be used for more than 4 months without any considerable divergence in potentials. The electrodes revealed comparatively good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of lead ions (with sulfate and oxalate ions), and for the determination of lead in waste waters.  相似文献   

17.
A novel thia-aza substituted macrocyclic diamide 7,10,13-triaza-1-thia-4,16-dioxa-20,24-dimethyl-2,3;17,18-dibenzo-cyclooctadecane-6,14-dione (L) was synthesized and stability of its complexes with several alkaline earth, transition and heavy metal ions were studied conductometrically in methanol solution. The resulting 1:1 Ag+L complex found to be the most stable one among all cation complexes studied. The optimized structures of the ligand and its Ag+ complex were also investigated. Based on the preliminary results thus obtained, L was used as an excellent sensing material to prepare polymeric membrane (PME) and coated graphite (CGE) silver-selective electrodes. The electrodes revealed a Nernstian behavior over wide Ag+ ion concentration ranges (i.e., 2.0 × 10?6–1.0 × 10?2 M for PME and 5.0 × 10?7–1.0 × 10?2 M for CGE). The potentiometric responses were independent of pH of the test solution in the range 2.9–6.8. The electrodes possessed advantages of low resistance, relatively fast response time, long lifetimes and, especially, good selectivity relative to a wide variety of other cations. The electrodes were used, as indicator electrodes, in the potentiometric titration of silver ion and in the determination of Ag+ ion in waste water, photographic emulsion, radiographic and photographic films and dental amalgams.  相似文献   

18.
A PVC membrane incorporating p-tert-butyl calix[4]crown with imine units as an ionophore was prepared and used in an ion-selective electrode for the determination of mercury(II) ions. An electrode based on this ionophore showed a good potentiometric response for mercury(II) ions over a wide concentration range of 5.0 x 10(-5) - 1.0 x 10(-1) M with a near-Nernstian slope of 27.3 mV per decade. The detection limit of the electrode was 2.24 x 10(-5) M and the electrode worked well in the pH range of 1.3 - 4.0. The electrode showed a short response time of less than 20 s. The electrode also showed better selectivity for mercury(II) ions over many of the alkali (Na+, -1.69; K+, -1.54), alkaline-earth (Ca2+, -3.30; Ba2+, -3.32), and heavy metal ions (Co2+, -3.67; Ni2+, -3.43; Pb2+, -3.31; Fe3+, -1.82). Ag+ ion was found to be the strongest interfering ion. Also, sharp end points were obtained when the sensor was used as an indicator electrode for the potentiometric titration of mercury(II) ions with iodide and dichromate ions.  相似文献   

19.
A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0. The electrode shows a linear response for Ag+ ion over the concentration range of 1.0 x 10(-60 to 1.0 x 10(-1) M with a lower detection limit of 6.0 x 10(-7) M. The electrode possesses a Nernstian slope of 59.7 mV decade(-1) and a fast response time of < or = 17 s and can be used for at least 2 months without any observable deviation. The proposed electrode displayed very good selectivity for Ag+ ion with respect to NH4+ and alkali, alkaline earth and some common transition metal ions. The practical utility of the electrode has been demonstrated by its use as the indicator electrode in the potentiometric titration of an AgNO3 solution with a NaI solution and in determination of the silver content of a developed radiological film.  相似文献   

20.
Four different recently synthesized macrocyclic diamides were studied to characterize their abilities as uranyl ion carriers in PVC membrane electrodes. The electrodes based on macrocycle 1,18-diaza-3,4;15,16-dibenzo-5,8,11,14,21,24-hexaoxacyclohexaeicosane-2,17-dione resulted in a Nernstian response for UO(2)(2+) ion over wide concentration ranges. The linear concentration range for the polymeric membrane electrode (PME) is 3.0x10(-6)-8.2x10(-3) M with a detection limit of 2.2x10(-6) and that for the coated graphite electrode (CGE) is 5.0x10(-7)-1.5x10(-3) M with a detection limit of 3.5x10(-7) M. The electrodes manifest advantages of low resistance, very fast response and, most importantly, good selectivities relative to a wide variety of other cations.  相似文献   