首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this study was to develop and validate a simple and sensitive liquid chromatography tandem mass spectrometry method for the determination of ulixertinib in rat plasma. The plasma samples were precipitated with acetonitrile and then separated on a C18 column with water containing 0.1% formic acid and acetonitrile as mobile phase at a flow rate of 0.3 mL/min. Analytes were monitored on a TSQ Vantage triple quadrupole tandem mass spectrometer operated in positive electrospray ionization mode. Selected reaction monitoring transitions were m/z 433.1→262.1 for ulixertinib and m/z 450.1→260.1 for internal standard. The assay achieved good linearity over the concentration range of 0.1‐1000 ng/mL with correlation coefficient > 0.9991. The validated assay has been successfully applied to pharmacokinetic study of ulixertinib in rat after oral and intravenous administration. The results revealed that ulixertinib showed high exposure in rat plasma, low clearance, moderate oral bioavailability (45.13%), and dose‐independent pharmacokinetic profiles over the oral dose range of 1‐15 mg/kg. In addition, six metabolites from rat plasma and hepatocytes were detected and structurally identified by ultra‐high performance liquid chromatography combined with high‐resolution mass spectrometry. The metabolic pathways of ulixertinib referred to hydroxylation and dealkylation and glucuronidation.  相似文献   

2.
A rapid and sensitive liquid chromatography tandem mass spectrometry detection using selected reaction monitoring in positive ionization mode was developed and validated for the quantification of nodakenin in rat plasma and brain. Pareruptorin A was used as internal standard. A single step liquid–liquid extraction was used for plasma and brain sample preparation. The method was validated with respect to selectivity, precision, accuracy, linearity, limit of quantification, recovery, matrix effect and stability. Lower limit of quantification of nodakenin was 2.0 ng/mL in plasma and brain tissue homogenates. Linear calibration curves were obtained over concentration ranges of 2.0–1000 ng/mL in plasma and brain tissue homogenates for nodakenin. Intra‐day and inter‐day precisions (relative standard deviation, RSD) were <15% in both biological media. This assay was successfully applied to plasma and brain pharmacokinetic studies of nodakenin in rats after intravenous administration.  相似文献   

3.
Oleuropein (OE) is the cardinal bioactive compound derived from Olea europaea and possesses numerous beneficial properties for human health. However, despite the plethora of analytical methods that have studied the biological fate of olive oil‐derived bioactive compounds, no validated methodology has been published to date for the simultaneous determination of OE, along with all its major metabolites. In this study, a liquid chromatography‐electrospray ionization‐tandem mass spectrometry (LC‐ESI MS/MS) method has been developed and validated for the quantification of OE, simultaneously with its main metabolites hydroxytyrosol, 2‐(3,4‐dihydroxyphenyl)acetic acid, 4‐(2‐hydroxyethyl)‐2‐methoxy‐phenol or homovanillyl alcohol, 2‐(4‐hydroxy‐3‐methoxyphenyl)acetic acid or homovanillic acid, and elenolic acid in rat plasma matrix. Samples were analyzed by LC‐ESI MS/MS prior to and after enzymatic treatment. A solid‐phase extraction step with high mean recovery for all compounds was performed as sample pretreatment. Calibration curves were linear for all bioactive compounds over the range studied, while the method exhibited good accuracy, intra‐ and inter‐day precision. The limit of detection was in the picogram range (per milliliterof plasma) for HT and OE and in the nanogram range (per milliliter of plasma) for the other analytes, and the method was simple and rapid. The developed methodology was successfully applied for the simultaneous quantification of OE and its aforementioned metabolites in rat plasma samples, thus demonstrating its suitability for pharmacokinetics, as well as bioavailability and metabolism studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Sparfloxacin, a fluoroquinolone antibiotic, is used for the treatment of bacterial infection. A quantification method using mass spectrometry was developed for the determination of sparfloxacin in rat plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed‐phase C18 column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma sparfloxacin concentrations after a single oral administration of sparfloxacin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
Homoegonol is a biologically active neolignan isolated from Styrax species with cytotoxic, antimicrobial, anti‐inflammatory and anti‐asthma activities. For the quantification of homoegonol in rat plasma, a selective and sensitive liquid chromatography–tandem mass spectrometric method was developed and validated for the first time using protein precipitation with methanol as a sample clean‐up procedure. The analytes were separated in an Atlantis dC18 column using a gradient elution of methanol and 0.1% formic acid, and mass‐to‐charge ratios were determined in selective reaction monitoring mode using tandem mass spectrometry with m/z 343.12 > 296.97 for homoegonol and m/z 517.30 > 282.90 for udenafil (internal standard). The standard curve was linear over the concentration ranges of 1 ? 500 ng/mL using a 30 μL rat plasma sample. The coefficient of variation and relative error for intra‐ and inter‐assay at four quality control levels were 3.9–10.0 and ‐3.3–2.7%, respectively. The overall recovery of homoegonol from rat plasma using protein precipitation was 99.7 ± 7.7%. The pharmacokinetics parameters of homoegonol were dose‐independent after both intravenous (1, 2.5 and 5 mg/kg doses) and oral (5, 10 and 20 mg/kg doses) administration in male Sprague–Dawley rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma.  相似文献   

7.
A novel, specific and rapid ultra performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for determination of teniposide in rat plasma. A one‐step liquid–liquid extraction method was used and the separation was carried out on an Acquity UPLCTM BEH C18 column with gradient elution using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.20 mL/min. A triple quadrupole tandem mass spectrometer in multiple‐reaction monitoring mode via an electrospray ionization interface was used for the detection of teniposide. The detection was complete within 3.0 min. A linear calibration curve was obtained over the concentration range 10–10,000 ng/mL for teniposide, with a lower limit of quantification of 10 ng/mL. The intra‐day precision and inter‐day precision (relative standard deviation) were less than 10.23 and 13.09%, respectively. The developed method was applied for the first time to the pharmacokinetic study of teniposide in rats following a single intravenous administration of 4.5 mg/kg teniposide. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Physalins are the major steroidal constituent of Physalis plants and display a range of biological activities. For this study, a rapid and sensitive high‐performance liquid chromatography with triple quadrupole mass spectrometry method was developed for the simultaneous quantification of six physalins. Specifically, it was for the quantification of physalin A, physalin B, physalin D, physalin G, 4,7‐didehydroneophysalin B, and isophysalin B in rat plasma and rat intestinal bacteria. After a solid‐phase extraction, analytes and internal standards (prednisolone) were separated on a Shield reverse‐phase C18 column (measuring 3 mm × 150 mm with an internal diameter of 3.5 μm) and determined using multiple reactions in a monitoring mode with a positive‐ion electrospray ionization source. The mobile phase was a mixture of 0.1% formic acid in water (A) and acetonitrile (B) and was used at a flow rate of 0.6 mL/min. The intra‐ and interday precisions were within 15% with accuracies ranging from 86.2 to 114%. The method was validated and successfully applied to pharmacokinetics and stability studies of six physalins in rat plasma and rat intestinal bacteria, respectively. The results showed that physalin B and isophysalin B could not be absorbed by rats, and rat intestinal bacteria could quickly transform physalins.  相似文献   

9.
A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of zidovudine in rat plasma. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 268/127 for zidovudine and m/z 230/112 for the internal standard. The method exhibited a linear dynamic range of 5-500 ng/mL for zidovudine in rat plasma. The lower limit of quantification was 5 ng/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 1.5 min for each sample made it possible to analyze more than 400 plasma samples per day. The validated method was applied for pharmacokinetic studies of the novel drug delivery systems of zidovudine in rats.  相似文献   

10.
Tetrodotoxin (TTX) exhibits the therapeutic potential in blocking pain and in low doses can safely relieve severe pain. The urinary excretion profiles of TTX in humans have not been reported due to the extremely low lethal dose. In this study, a rapid and specific method based on protein precipitation coupled to liquid chromatography tandem mass spectrometry was developed to determine the level of TTX in human urine samples. 11-Deoxytetrodotoxin was used as an internal standard (IS). Multiple reaction monitoring mode was used for quantification using target fragment ions m/z 320.0 → 162.1 for TTX and m/z 304.0 → 176.0 for 11-deoxyTTX. The separation of analytes was achieved on a hydrophilic interaction liquid chromatography column (250 × 4.6 mm, 5.0 μm). The mobile phase consisted of 5 mM ammonium formate in water (pH = 4.50) and 5 mM ammonium formate in acetonitrile (pH = 4.50). The flow rate was set at 0.80 mL/min in a gradient condition. Calibration plots were linear throughout the range 0.986–98.6 ng/mL of TTX in human urine. The intra-assay accuracies and precisions were within the acceptable range. The method was successfully applied to a urinary excretion study after intravenous administration of TTX to healthy volunteers. The developed method will be helpful for future pharmacological studies of TTX.  相似文献   

11.
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption.  相似文献   

12.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

13.
Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep-Pak C18 cartridges from whole blood and urine samples containing ethyl paraquat as an internal standard. The separation of PQ and DQ was carried out using ion-pair chromatography with heptafluorobutyric acid in 20 mM ammonium acetate and acetonitrile gradient elution for successful coupling with MS. Both compounds formed base peaks due to [M-H]+ ions by HPLC/ESI-MS and the product ions produced from each [M-H]+ ion by HPLC/MS/MS. Selective reaction monitoring (SRM) showed much higher sensitivity for both body fluids. Therefore, a detailed procedure for the detection of compounds by SRM with HPLC/MS/MS was established and carefully validated. The recoveries of PQ and DQ were 80.8-95.4% for whole blood and 84.2-96.7% for urine. The calibration curves for PQ and DQ showed excellent linearity in the range of 25-400 ng ml(-1) of whole blood and urine. The detection limits were 10 ng ml(-1) for PQ and 5 ng ml(-1) for DQ in both body fluids. The intra- and inter-day precision for both compounds in whole blood and urine samples were not greater than 13.0%. The data obtained from the determination of PQ and DQ in rat blood after oral administration of the compounds are also presented.  相似文献   

14.
Cyadox is a novel antimicrobial growth‐promoter of the quinoxalines. For food safety and pharmacokinetic studies, a convenient, sensitive and reproducible LC‐ESI‐MS/MS method was developed for the simultaneous determination of cyadox and its major metabolites, quinoxaline‐2‐carboxylic acid, 1,4‐bisdesoxycyadox, cyadox‐1‐monoxide and cyadox‐4‐monoxide in chicken plasma. Plasma sample was subjected to a simple deproteinisation with acetonitrile. Analysis was performed on a C18 column by detection with mass spectrometry in multiple reaction monitoring mode. A gradient elution program with 0.2% formic acid, methanol and acetonitrile was performed at a flow rate of 0.2 mL/min. The decision limits (CCαs) of five analytes in plasma ranged from 1.0 to 4.0 μg/L, and the detection capabilities (CCβs) were <10 μg/L. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The extraction recoveries of five analytes were between 87.4 and 93.9% in plasma at the spiked levels of 5 (10)–200 μg/L with the relative standard deviations <10% for each analyte. The developed method demonstrated a satisfactory applicability in real plasma samples.  相似文献   

15.
Aspirin eugenol ester (AEE) is a promising drug candidate for treatment of inflammation, pain and fever and prevention of cardiovascular diseases with fewer side effects than its precursor, aspirin. Investigation into its metabolic process in target animal species will help to illustrate its mechanism of action and to establish its residual mark compound to formulate its dosage. Six beagle dogs were orally given a dose of 20 mg kg?1 of AEE and one dog was used to prepare blank liver microsomes. Their liver microsomes were prepared for in vitro study and their plasma and urine were collected for in vivo metabolic analysis using liquid chromatography tandem mass spectrometry. In this study we identified 10 metabolites, M1, M2, M3, M4, M5 in phase I and M6, M7, M8, M9, M10 in phase II. Based on the metabolites of AEE, the pathways of AEE metabolism in dog were demonstrated. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

17.
A liquid chromatographic/tandem mass spectrometric method is described for the determination of phencyclidine (PCP) in small volumes of rat serum (e.g. 50 microl). Samples were extracted using a mixed-mode strong cation-exchange column and then separated isocratically using a narrow-bore (2.1 mm i.d.) 3 microm Hypersil phenyl column and a mobile phase consisting of an ammonium formate buffer (pH 2.7) with 60% (v/v) methanol. Detection was accomplished using positive ion electrospray ionization in the multiple reaction monitoring mode. Mass spectra were obtained and peaks were observed at an m/z (% abundance) of 244 (100), 159 (25), and 86 (89). Tandem mass spectra were also obtained from the m/z 244 precursor ion with peaks observed at m/z 159 (100), 86 (96), and 91 (11). Optimum serum PCP sensitivity and precision were obtained at a transition of m/z 244 --> 159. Matrix-associated ion suppression did not significantly affect the accuracy (100-112%) or precision (CV < or =8%) of the assay. The lower limit of quantitation was 1 ng ml(-1) in 50 microl of serum. The method was used to study the serum pharmacokinetics of PCP in rats after an intravenous bolus dose of PCP.  相似文献   

18.
A simple method using a one-step liquid-liquid extraction (LLE) followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of bromazepam in human plasma, using lorazepam as internal standard. The acquisition was performed in the multiple reaction monitoring mode, monitoring the transitions: m/z 316 > 182 for bromazepam and m/z 321 > 275 for lorazepam. The method was linear over the studied range (1-100 ng ml(-1)), with r(2) > 0.98, and the run time was 2.5 min. The intra- and inter-assay precisions were 2.7-14.6 and 4.1-17.3%, respectively and the intra- and inter-assay accuracies were 87-111 and 75.8-109.5%, respectively. The mean recovery was 73.7%, ranging from 64.5 to 79.7%. The limit of quantification was 1 ng ml(-1). At this concentration the mean intra- and inter-assay precisions were 14.6 and 7.1%, respectively, and the mean intra- and inter-assay accuracies were 102.5 and 104%, respectively. Bromazepam stability was evaluated and the results showed that the drug is stable in standard solution and in plasma samples under typical storage and processing conditions. The method was applied to a bioequivalence study in which 27 healthy adult volunteers (14 men) received single oral doses (6 mg) of reference and test bromazepam formulations, in an open, two-period, randomized, crossover protocol. The 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) (peak plasma concentration), AUC(0-96) and AUC(0-inf) (area under the plasma concentration versus time curve from time zero to 96 h and to infinity, respectively) were within the range 80-125%, which supports the conclusion that the test formulation is bioequivalent to the reference formulation regarding the rate and extent of bromazepam absorption.  相似文献   

19.
建立了一种贝类组织中原多甲藻酸(azaspiracid, AZA)贝类毒素主要成分AZA1的高效液相色谱-串联质谱检测方法。本方法采用甲醇-水(80:20, v/v)溶液对贝类组织中AZA1进行提取,并用MAX阴离子交换固相萃取(SPE)柱富集净化,使用Atlantis dC18(150 mm×4.6 mm, 5.0 μm)色谱柱分离,以含有50 mmol/L甲酸和2 mmol/L甲酸铵的乙腈-水溶液(80:20, v/v)为流动相进行等度洗脱,质谱采用选择反应监测(SRM)模式。AZA1在5 min内获得完全分离,且在48.85~2 442 ng/L范围内线性良好,相关系数为0.998 1。该方法检出限(S/N=3)为11.00 pg/g,添加水平为36.64、73.27、146.54 pg/g时的平均回收率为75.8%~82.5%(n=6),相对标准偏差小于10%。利用该方法对采自大连、青岛、广州水产品市场上的112个贝类样品进行了分析,发现采自大连和广州的部分贝类样品中含有AZA1。结果表明,该方法具有简单、快速、灵敏度高等特点,能充分满足贝类中AZA1检测的要求。  相似文献   

20.
A rapid, sensitive and specific method to quantify bromazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using diethyl ether-hexane (80 : 20, v/v). The extracts were analyzed by high-performance liquid chromatography (HPLC) coupled to electrospray tandem mass spectrometry (MS/MS). Chromatography was performed isocratically on a Genesis C(18) analytical column (100 x 2.1 mm i.d., film thickness 4 microm). The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 5.0-150 ng ml(-1) (r(2) > 0.9952). The limit of quantification was 5 ng ml(-1). This HPLC/MS/MS procedure was used to assess the bioequivalence of two bromazepam 6 mg tablet formulations (bromazepam from Medley SA Indústria Farmacêutica as the test formulation and Lexotan from Produtos Roche Químico e Farmacêutico SA as the reference formulation). A single 6 mg dose of each formulation was administered to 24 healthy volunteers (12 males and 12 females). The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. Since the 90% CI for C(max), AUC(last), AUC(0-240 h) (linear) and AUC((0- infinity )) ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the bromazepam formulation from Medley is bioequivalent to the Lexotan formulation for both the rate and the extent of absorption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏