首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A flow injection method for monitoring xylitol was developed using xylitol oxidase (XYO) immobilized on a VA-Epoxy Biosynth E3-support. The immobilized XYO cartridge had a good operational lifetime (up to 24 h) and storage stability (up to 1 month). The XYO-FIA system with an oxygen electrode was investigated systematically regarding the factors that can affect enzyme activity, such as pH, reaction temperature, carrier solution and sample matrix. In order to attain high activity of the immobilized XYO, potassium phosphate solution (1 M) with 0.5 g l−1 Triton X-100 adjusted to pH 8.5 was used as the carrier solution. Sample matrix effects on the immobilized XYO were also investigated. High concentrations of some components (arabinose, 20 g l−1; xylose, 30 g l−1; NaCl, 30 g l−1) in the sample had significant inhibitory effects on the response of the XYO-FIA system. The performance of the XYO-FIA system was tested by using different sample injection volumes (75-250 μl) and carrier flow rates (0.7-2.0 ml min−1).  相似文献   

2.
A flow system was coupled to a graphite furnace with a platform coated with tungsten-rhodium permanent chemical modifier for in-line separation and preconcentration of copper by employing a minicolumn loaded with 1-(2-tiazolylazo)-2-naphthol (TAN) immobilized on C18-bonded silica fixed in the tip of the autosampler arm. Elution was made by sampling 35 μl of 0.50 mol l−1 HCl with further delivering into a coated platform. Remarkable improvements in both selectivity and sensitivity were observed. Copper(II) was effectively separated from solutions containing up to 20 g l−1 Na+; 10 g l−1 K+, Ca2+ and Mg2+; 1.0 g l−1 Fe3+ and Zn2+. For a sample flowing at 3.0 ml min−1 and a loading of 60 s, the detection limit was estimated as 5 ng l−1 Cu(II) at the 99.7% confidence level, and an enrichment factor of 33 was calculated. Coefficient of variation was estimated as 4% for a 0.30 μg l−1 copper solution (n=20). The W-Rh permanent chemical modifier was used to improve system stability, analytical performance and atomizer lifetime. More than 1500 firings were carried out with the same atomizer without significant variations in sensitivity and precision. On account of the reagent immobilization, its consumption was lower than 0.2 μg per determination. In addition, TAN purification was unnecessary.  相似文献   

3.
An automated system to perform liquid-liquid extraction is proposed, in which the effective mixture (the intimate contact) between the aqueous phase and the organic phase, as well as the separation of the phases, are carried out in a micro-batch glass extraction chamber. Sample, reagents and organic solvent are introduced into the glass extraction chamber by a peristaltic pump using air as carrier. The detection of the extracted species from the aqueous phase is made in a small volume (120-150 μl) of isobutyl methyl ketone (MIBK). The system allows enrichment factors of 2-10-fold. The proposed automatic system was evaluated for Cu(II) extraction based on complex formation between copper(II) and 1-(2′-pyridylazo)naphthol (PAN) in MIBK. When a volumetric ration of 2:1 (aqueous:organic) was implemented, copper was detected in the concentration range of 100-1600 μg l−1 (r = 0.9995) with a relative standard deviation of 2% (200 μg l−1, n = 5) and a detection limit of 20 μg l−1. The analytical curve was linear over the concentration range 25-500 μg l−1 (r = 0.9994) when a volumetric ratio of 10:1 was employed. With this ratio, the detection limit was 5.0 μg l−1 and the relative standard deviation was 6% (50 μg l−1, n = 5).  相似文献   

4.
A flow injection analysis (FIA) method using on-line separation and preconcentration with a novel metal scavenger beads, QuadraSil™ TA, has been developed for the ICP-OES determination of traces of palladium. QuadraSil TA contains diethylenetriamine as a functional group on spherical silica beads and shows the highest selectivity for Pd(II) at pH 1 (0.1 mol l−1 hydrochloric acid) solution. An aliquot of the sample solution prepared as 0.1 mol l−1 in hydrochloric acid was passed through the QuadraSil TA column. After washing the column with the carrier solution, the Pd(II) retained on the column was eluted with 0.05 mol l−1 thiourea solution and the eluate was directly introduced into an ICP-OES. The proposed method was successfully applied to the determination of traces of palladium in JSd-2 stream sediment certified reference material [0.019 ± 0.001 μg g−1 (n = 3); provisional value: 0.0212 μg g−1] and SRM 2556 used auto catalyst certified reference material [315 ± 4 μg g−1 (n = 4); certified value: 326 μg g−1]. The detection limit (3σ) of 0.28 ng ml−1 was obtained for 5 ml of sample solution. The sample throughputs for 5 ml and 100 μl of the sample solutions were 10 and 15 h−1, respectively.  相似文献   

5.
A new flow injection (FI) system for the determination of Pb(II) at trace level with a preconcentration step and spectrophotometric detection is proposed. It is based on preconcentration of lead ions on chitosan and dithizone-lead complex formation in aqueous medium (pH 9). The chemicals and FIA variables influencing the performance of the system were optimized and applied to the determination of lead in natural, well, and drinking water samples. It is a simple, highly sensitive, and low cost alternative methodology. The method provided a linear rage between 25 and 250 μg l−1, a detection limit of 5.0 ng ml−1 and a sample throughput of 15 h−1. The obtained results of spiked samples are in good agreement between the proposed method and ICP-AES.  相似文献   

6.
C. March  Y. Jiménez  A. Montoya 《Talanta》2009,78(3):827-1971
A quartz crystal microbalance (QCM) immunosensor was developed for the determination of the insecticide carbaryl and 3,5,6-trichloro-2-pyridinol (TCP), the main metabolite of the insecticide chlorpyrifos and of the herbicide triclopyr. The detection was based on a competitive conjugate-immobilized immunoassay format using monoclonal antibodies (MAbs). Hapten conjugates were covalently immobilized, via thioctic acid self-assembled monolayer (SAM), onto the gold electrode sensitive surface of the quartz crystal. This covalent immobilization allowed the reusability of the modified electrode surface for at least one hundred and fifty assays without significant loss of sensitivity. The piezoimmunosensor showed detection limits (analyte concentrations producing 10% inhibition of the maximum signal) of 11 and 7 μg l−1 for carbaryl and TCP, respectively. The sensitivity attained (I50 value) was around 30 μg l−1 for both compounds. Linear working ranges were 15-53 μg l−1 for carbaryl and 13-83 μg l−1 for TCP. Each complete assay cycle took 20 min. The good sensitivity, specificity, and reusability achieved, together with the short response time, allowed the application of this immunosensor to the determination of carbaryl and TCP in fruits and vegetables at European regulatory levels, with high precision and accuracy.  相似文献   

7.
《Analytica chimica acta》2002,471(2):173-186
An automated and versatile sequential injection spectrofluorimetric procedure for the simultaneous determination of multicomponent mixtures in micellar medium without prior separation processes is reported. The methodology is based upon the segmentation of a sample slug between two different buffer zones in order to attain both an improvement of sensitivity and residual minimization for the whole species. Resolution of overlapping fluorescence profiles is achieved using a variable angle scanning technique coupled to multivariate least-squares regression (MLR) algorithms at both sample edges.The potentialities of the described methodology are illustrated with the spectrofluorimetric determination of four widespread pesticides with different acid-base properties; viz. carbaryl (CBL) (1-naphthyl-N-methylcarbamate), fuberidazole (FBZ) (2-(2′-furyl)benzimidazole), thiabendazole (TBZ) (2-(4′-thiazolyl)benzimidazole) and warfarin (W) (3-α-acetonylbenzyl)-4-hydroxycoumarin). Detection limits at the 3σ level were 3.9, 0.02, 0.03 and 10 μg l−1 for CBL, FBZ, TBZ and W, respectively at the maximum sensitivity pH. Dynamic ranges of 13-720 μg l−1 CBL, 0.10-14 μg l−1 FBZ, 0.19-60 μg l−1 TBZ and 0.05-5 mg l−1 W were achieved. Relative standard deviations (n=10) were 0.2% for 100 μg l−1 CBL and 2.4 μg l−1 FBZ, 0.7% for 8 μg l−1 TBZ and 1.0% for 1 mg l−1 W. The proposed automated methodology, which handles 17 samples/h, was validated and applied to spiked real water samples with very satisfactory results.  相似文献   

8.
This paper reports the development of a new strategy for low-level determination of copper in water samples by using a flow-injection system coupled to solid-phase extraction (SPE) using flame atomic absorption spectrometry (F AAS) as detector. In order to preconcentrate copper from samples, a minicolumn packed with a styrene-divinylbenzene resin functionalized with (S)-2-[hydroxy-bis-(4-vinyl-phenyl)-methyl]-pyrrolidine-1-carboxylic acid ethyl ester was used and the synthesis procedure is described. System operation is based on the on-line retention of Cu(II) ions at pH 9.0 ± 0.2 in a such minicolumn with posterior analyte elution with 2 mol l−1 HCl directly to the F AAS nebulizer. The influence of several chemical (sample pH, buffer concentration, HCl eluent concentration and effect of the ionic strength) and flow (sample and eluent flow rates and preconcentration time) variables that could affect the performance of this system were investigated as well as the possible interferents. At optimized conditions, for 2 min of preconcentration time (13.2 ml of sample volume), the system achieved a detection limit of 1.1 μg l−1, a R.S.D. 1% at 20 μg g l−1 and an analytical throughput of 25 h−1, whereas for 4 min of preconcentration time (26.4 ml of sample volume), a detection limit of 0.93 μg l−1, a R.S.D. 5.3% at 5 μg l−1 and a sampling frequency of 13 h−1 were reported.  相似文献   

9.
Conversion of nitrate into a nitro-phenol derivative by reaction with 2-methylphenol or 2,6-dimethylphenol allowed at least 100-fold enrichment of the derivative on Lichrolut EN polymeric cartridge, and it is stable for up to 1 month on the cartridge. The derivative could be eluted with ammonia-methanol mixture. This reaction for nitrate determination has permitted a choice of final measurement by UV-Vis spectrophotometry, liquid chromatography or gas chromatography-mass spectrometry when the limits of detection were 10, 6 and 3 μg l−1, respectively, and the calibration range 20 μg to 10 mg l−1 nitrate. The method has been validated by spiking natural water samples, when the recovery of nitrate was 98.5-108.4% (relative standard deviation 2.5-6.1%).  相似文献   

10.
A flow-batch system was developed for the determination of Fe(III) in estuarine waters with high variability in salinity. The method is based on the catalytic effect of iron(III) on the oxidation rate of N,N-dimethyl-p-phenylenediammonium dichloride (DmPD) by hydrogen peroxide and the formed product is spectrophotometrically monitored at 554 nm. A controlled addition of sodium chloride to every assayed sample is accomplished for in-line individual salinity matching.The proposed system processes about 30 samples h−1 and yields reproducible results. Relative standard deviations were estimated as <1.5% after 10 injections of typical samples (10.0-50.0 μg l−1 Fe; ca. 0.5 mol l−1 Cl). Synthetic samples (15.0 μg l−1 Fe; 0.25-1.0 mol l−1 NaCl) were efficiently processed, and no significant differences in results were found at a probability level of 99.7%. The method works for the full range of salinities. Only 120 μg DmPD are consumed per determination. The analytical curve is linear up to about 60 μg l−1 Fe (r>0.999; n=5) and the detection limit is 5 μg l−1 Fe. Results are in agreement with graphite furnace atomic absorption spectrometry.  相似文献   

11.
A new multisyringe flow injection system for total inorganic selenium determination by hydride generation-atomic fluorescence spectrometry (HGAFS) has been proposed. The flow methodology is based on the simultaneous injection of sample in the acid media (50% HCl), a reducing sodium tetrahydroborate solution (0.18%) and a solution of hydrochloric acid (50%) which are dispensed into a gas-liquid separation cell by using a multisyringe burette coupled with one multiport selection valve. The usage of the time-based injection increases the sample throughput and provides precise known volumes of sample. The hydride of selenium is delivered into the flame of an atomic fluorescence spectrometer by means of an argon flow. A hydrogen flow has been used to support the flame.The technique can be applied over a wide range of concentrations of selenium between 0.1 and 3.5 μg l−1 with good repeatability (relative standard deviation (R.S.D.) values 4.6-7% for 1 μg l−1 of Se). The detection limit of the developed technique (3σb/S) was 0.01 μg l−1. A sample throughput was 28 samples per hour (84 injections). The multisyringe technique has been validated by means of reference solid (sea lettuce) and water (hard drinking water) materials with good agreement with certified values. The analytical features were compared with those obtained by using of the commercial flow injection analysis (FIA) system. The proposed method provides a higher sampling frequency and a significant reduction of reagent and sample consumption in front the flow injection application.  相似文献   

12.
Isoproturon was extracted selectively from environmental materials (water samples) using an immunosorbent column containing anti-isoproturon antibodies encapsulated in a silica matrix by a sol-gel process. A phosphate buffered saline (PBS) conditioned immunosorbent column was used to on-line preconcentrate 5 ml well and tap water containing 0.05 μg l−1 of isoproturon, which were desorbed with 75 μl of citric acid and determined with a solid phase competitive fluoroimmunoassay. The solid phase of the immunosensor, consisting of a sol-gel glass doped with anti-isoproturon monoclonal antibody, was placed on the flow-cell of the spectrofluorometer. Free isoproturon in solution competed with a fluorescent conjugated isoproturon and reduced the support bonded fluorescence in a concentration-dependent manner. The on-line method has a detection limit of 9.7 ng l−1, relative standard deviation of 4 and 3% for 0.05 and 0.5 μg l−1, respectively, and recoveries higher than 90% for tap and well water. For comparison the off-line extraction and clean up using a C18 cartridge is also reported.  相似文献   

13.
A general and broad class selective enzyme-linked immunosorbent assay was developed for the type II pyrethroid insecticides, such as cypermethrin, deltamethrin, cyhalothrin, cyfluthrin, fenvalerate, esfenvalerate and fluvalinate. Polyclonal antibodies were generated by immunizing with a type II pyrethroid immunogen ((RS)-α-cyano-3-phenoxybenzyl (RS)-cis,trans-2,2-dimethyl-3-carboxyl-cyclopropanecarboxylate) conjugated with thyroglobulin. Antisera were screened against nine different coating antigens. The antibody-antigen combination with the most selectivity for type II pyrethroids such as cypermethrin was further optimized and tested for tolerance to co-solvent, pH and ionic strength changes. The IC50s of the optimized immunoassay were 78 μg l−1 for cypermethrin, 205 μg l−1 for cyfluthrin, 120 μg l−1 for cyhalothrin, 13 μg l−1 for deltamethrin, 6 μg l−1 for esfenvalerate, 8 μg l−1 for fenvalerate and 123 μg l−1 for fluvalinate. No cross-reactivity was measured for the type I pyrethroids such as permethrin, bifenthrin, phenothrin, resmethrin and bioresmethrin. This assay can be used in monitoring studies to distinguish between type I and II pyrethroids.  相似文献   

14.
A flow injection on-line sorption preconcentration system has been synchronously coupled to an electrothermal atomic absorption spectrometry (ETAAS) system for the selective determination of trace amounts of Sb(III) in water, soil and plant. The determination was achieved by selective complexation and sorption of Sb(III) with [1,5-bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydarzide (PSTH) immobilized on an anion-exchange resin (Dowex 1× 8-200)] at a wide range of pH, quantitative elution with 50 μl of 2 M HNO3 and subsequent ETAAS detection. ETAAS determination of the analyte was performed in parallel with the preconcentration of the next sample. Using a preconcentration time of 60 s and a sample loading flow rate of 2.8 ml min−1, an enhancement factor of 12 was obtained in comparison with direct injection of 50 μl aqueous solution, resulting in a sampling frequency of 31 samples h−1. The detection limit (3 s) was 2 μg l−1 and the precision was 3.1% (R.S.D.) for 11 replicate determinations at 10 μg l−1. The accuracy of the proposed method was demonstrated by analyzing one certified sample and different spiked samples.  相似文献   

15.
A robust flow injection (FI) on-line liquid-liquid extraction (LLE) preconcentration/separation system associated with a newly designed gravitational phase separator, coupled to flame atomic absorption spectrometry (FAAS) was developed. The performance of the system was illustrated for cadmium determination at the μg l−1 level. The non-charged cadmium complex with ammonium pyrrolidine dithiocarbamate (APDC) was extracted on-line into isobutyl methyl ketone (IBMK). The organic phase was effectively separated from a large volume of aqueous phase and is led into a 100 μl loop of an injection valve before its introduction into the nebulizer. The system was optimized and offered good performance characteristics with unlimited life time of phase separator, greater flow rate ratios and improved flexibility, as compared with other solvent extraction preconcentration systems. With a sampling frequency of 33 h−1, the enhancement factor was 155, the detection limit was 0.02 μg l−1, the relative standard deviation was 3.2% at 2.0 μg l−1 Cd concentration level and the calibration curve was linear over the concentration range 0.06-6.0 μg l−1. The accuracy of the proposed method was evaluated by analyzing a certified reference material of water and by recovery measurements on spiked samples. Finally, it was successfully applied to the analysis of tapwater, river and seawater samples.  相似文献   

16.
The operational characteristics of a novel poly(tetrafluoroethylene) (PTFE) bead material, granular Algoflon®, used for separation and preconcentration of metal ions via adsorption of on-line generated non-charged metal complexes, were evaluated in a sequential injection (SI) system furnished with an external packed column and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used material, Aldrich PTFE, which had demonstrated that PTFE was the most promising for solid-state pretreatments. By comparing the two materials, the Algoflon® beads exhibited much higher sensitivity (1.6107 μg l−1 versus 0.2956 μg l−1 per integrated absorbance (s)), and better retention efficiency (82% versus 74%) and enrichment factor (20.8 versus 17.2), although a slightly smaller linear dynamic range (0.05-0.25 μg l−1 versus 0.05-1.00 μg l−1). Moreover, no flow resistance was encountered under the experimental conditions used. The results obtained on three standard reference materials were in good agreement with the certified values.  相似文献   

17.
Amberlite XAD-4 resin has been functionalized with succinic acid by coupling it with dibromosuccinic acid after acetylation. The resulting resin has been characterized by FT-IR, elemental analysis and TGA and has been used for preconcentrative separation of uranium(VI) from host of other inorganic species prior to its determination by spectrophotometry. The optimum pH value for quantitative sorption of uranium(VI) in both batch and column modes is 4.5-8.0 and desorption can be achieved by using 5.0 ml of 1.0 mol l−1 HCl. The sorption capacity of functionalized resin is 12.3 mg g−1. Calibration graphs were rectilinear over the uranium(VI) concentrations in the range 5-200 μg l−1. Five replicate determinations of 50 μg of uranium(VI) present in 1000 ml of solution gave a mean absorbance of 0.10 with a relative standard deviation of 2.56%. The detection limit corresponding to three times the standard deviation of the blank was found to be 2 μg l−1. Various cationic and anionic species at 200-fold amounts do not interfere during the preconcentration of 5.0 μg of uranium(VI) present in 1000 ml (batch) or 100 ml (column) of sample solution. Further, adsorption kinetic and isotherm studies were also carried out by a batch method to understand the nature of sorption of uranium(VI) with the succinic acid functionalized resin. The accuracy of the developed solid phase extractive preconcentration method in conjunction with Arsenazo III procedure was tested by analyzing marine sediment (MESS-3) and soil (IAEA soil-7) reference material. Further, the above procedure has been successfully employed for the analysis of soil and sediment samples.  相似文献   

18.
A novel all-solid-state miniaturized nitrate sensor is developed, characterized and used for flow injection analysis (FIA) of nitrates in various samples. The sensor incorporates silver bis(bathophenanthroline) nitrate [Ag(bath)2NO3] as an electroactive material in a plasticized PVC membrane. The sensing membrane (3 mm × 5 mm) is immobilized on a wafer polyimide microchip (size 13.5 mm × 3.5 mm) to offer a planar miniaturized design easily used in a single channel wall-jet flow injection system. Under hydrodynamic mode of operation (FIA) the sensor displays fast response, high sensitivity, long term stability and good selectivity for NO3 in the presence of many common associated anions. The calibration slope is 55.1 ± 0.1 mV decade−1 over the concentration range 1.0 × 10−1 to 1.0 × 10−6 mol L−1, the lower detection limit is 0.05 μg mL−1, the working pH is 2-9,and the output is 70-90 samples h−1. Validation of the assay method reveals good performance characteristics and suggests application for routine determination of NO3 in industrial wastewaters, fertilizers and pharmaceuticals. The results agree fairly well with data obtained by the standard spectrophotometric methods.  相似文献   

19.
Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l−1 and sample throughput of 70 samples h−1 were achieved. The relative standard deviations for 50 and 500 μg P l−1 orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l−1 was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l−1 standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples.  相似文献   

20.
In this study, a simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME) combined gas chromatography-electron capture detection (GC-ECD), for the determination of chlorobenzenes (CBs) in water samples, has been described. This method involves the use of an appropriate mixture of extraction solvent (9.5 μl chlorobenzene) and disperser solvent (0.50 ml acetone) for the formation of cloudy solution in 5.00 ml aqueous sample containing analytes. After extraction, phase separation was performed by centrifugation and the enriched analytes in sedimented phase were determined by gas chromatography-electron capture detection (GC-ECD). Our simple conditions were conducted at room temperature with no stiring and no salt addition in order to minimize sample preparation steps. Parameters such as the kind and volume of extraction solvent, the kind and volume of disperser solvent, extraction time and salt effect, were studied and optimized. The method exhibited enrichment factors and recoveries ranging from 711 to 813 and 71.1 to 81.3%, respectively, within very short extraction time. The linearity of the method ranged from 0.05 to 100 μg l−1 for dichlorobenzene isomers (DCB), 0.002-20 μg l−1 for trichlorobenzene (TCB) and tetrachlorobenzene (TeCB) isomers and from 0.001 to 4 μg l−1 for pentachlorobenzene (PeCB) and hexachlorobenzene (HCB). The limit of detection was in the low μg l−1 level, ranging between 0.0005 and 0.05 μg l−1. The relative standard deviations (R.S.D.s) for the concentration of DCB isomers, 5.00 μg l−1, TCB and TeCB isomers, 0.500 μg l−1, PeCB and HCB 0.100 μg l−1 in water by using the internal standard were in the range of 0.52-2.8% (n = 5) and without the internal standard were in the range of 4.6-6.0% (n = 5). The relative recoveries of spiked CBs at different levels of chlorobenzene isomers in tap, well and river water samples were 109-121%, 105-113% and 87-120%, respectively. It is concluded that this method can be successfully applied for the determination of CBs in tap, river and well water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号