首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 542 毫秒
1.
The potentiometric response characteristics of Cu2+-selective electrodes based on bis(acetylacetone)propylenediimine (I) combined with anion localizing agent (sodium tetraphenyl borate (NaTPB)) and solvent mediators (dibutyl butyl phosphonate (DBBP), tri-n-butyl phosphate (TBP) and chloronaphthalene (CN)) were investigated. The best results for Cu2+ sensing was obtained for the electrode membrane containing PVC, I, DBBP and NaTPB in composition 5:100:200:6 (I:PVC:DBBP:NaTPB) (w/w; mg), where the electrode had a Nernstian response (30.0 mV/decade) to Cu2+ within the concentration range 1.0 × 10−5 to 1.0 × 10−1 M and detection limit of 0.5 ppm. The operational pH range of the electrode was 3.3-7.0. Selectivity characteristic of the proposed electrode was also assessed by calculating using fixed interference method matched potential method. The sensor has been successfully used in the potentiometric titration of copper ions with EDTA.  相似文献   

2.
Vinod K. Gupta  Manoj K. Pal 《Talanta》2010,82(4):1136-1142
A new terbium selective sensor based on N-(2-hydroxyphenyl)-3-(2-hydroxyphenylhydroxyphenylimino)-N-phenylbutanamidine (L1) and N,N′-bis((1H-indole-3-yl)methylene)butane-1,4 diamine (L2) as a ionophore is reported. Effect of various plasticizers; 2-nitrophenyloctylether (o-NPOE), dibutyl butylphosphonate (DBBP), chloronaphthelene (CN), dioctylphthalate (DOP) and tri-(2-ethylhexyl)phosphate (TEHP) with anion excluder, potassium tetrakis (p-chloropheny1)borate (KTpClPB) have been studied. The membrane with a composition of ionophore (L1):KTpClPB:PVC:o-NPOE (w/w, %) in ratio of 3.0:5.0:30.0:62.0 exhibited enhanced selectivity towards terbium ions (III) in the concentration range of 3.5 × 10−7 to 1.0 × 10−2 M with a detection limit of 1.2 × 10−7 M and a Nernstian slope (20.0 ± 0.5 mV dec−1 activity). The sensors showed the working pH range to be 3.5-7.5 with response time of 11 s. The sensor has been found to work satisfactorily in partially non-aqueous media up to 15% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients indicated high selectivity for terbium (III). The fast and stable response, good reproducibility and long-term stability of the sensors were observed. The application of the sensor has been demonstrated in determination of terbium (III) ions in spiked water samples.  相似文献   

3.
Comparative studies of neodymium (III)-selective PVC membrane sensors   总被引:1,自引:0,他引:1  
Sensors based on two neutral ionophores, N,N′-bis((1H-pyrrol-2-yl)methylene)cyclohexane-1,2-diamine (L1) and 3,3′-(cyclohexane-1,2-diylbis(azan-1-yl-1-ylidene)bis(methan-1-yl-1-ylidene)bis(5-hydroxymethyl)pyridine-2-ol) (L2) are described for quantification of neodymium (III). Effect of various plasticizers; 2-nitrophenyloctylether (o-NPOE), dibutyl butylphosphonate (DBBP), tri-n-butyl phosphates (TBP), dioctylpthalate (DOP) and chloronapthalen (CN) and anion excluder, sodiumtetraphenylborate (NaTPB) has been studied. The membrane composition of PVC:o-NPOE:ionophore (L1):NaTPB (w/w; mg) of 150:300:5:5 exhibited best performance. The sensor with ionophore (L1) exhibits significantly enhanced selectivity towards neodymium (III) in the concentration range 5.0 × 10−7 to 1.0 × 10−2 M with a detection limit of 1.0 × 10−7 M and a Nernstian compliance (19.8 ± 0.3 mV decade−1 of activity) within pH range 4.0-8.0. The response time of sensor was found as 10 s. The influence of the membrane composition and possible interfering ions has also been investigated on the response properties of the electrode. The fast and stable response, good reproducibility and long-term stability of the sensor are observed. The sensor has been found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients determined by using fixed interference method (FIM) indicate high selectivity for neodymium. The proposed electrode shows fairly good discrimination of neodymium (III) from other cations. The application of prepared sensor has been demonstrated in the determination of neodymium (III) in spiked water samples.  相似文献   

4.
Praseodymium ion selective polyvinyl chloride (PVC) membrane sensors, based on two new Schiff's bases 1,3-diphenylpropane-1,3-diylidenebis(azan-1-ylidene)diphenol (M1) and N,N′-bis(pyridoxylideneiminato) ethylene (M2) have been developed and studied. The sensor having membrane composition of PVC: o-NPOE: ionophore (M1): NaTPB (w/w; mg) of 150: 300: 8: 5 showed best performances in comparison to M2 based membranes. The sensor based on (M1) exhibits the working concentration range 1.0 × 10−8 to 1.0 × 10−2 M with a detection limit of 5.0 × 10−9 M and a Nernstian slope 20.0 ± 0.3 mV decade−1 of activity. It exhibited a quick response time as <8 s and its potential responses were pH independent across the range of 3.5-8.5.The influence of the membrane composition and possible interfering ions have also been investigated on the response properties of the electrode. The sensor has been found to work satisfactorily in partially non-aqueous media up to 15% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients determined by using fixed interference method (FIM) indicate high selectivity for praseodymium(III) ions over wide variety of other cations. To asses its analytical applicability the prepared sensor was successfully applied for determination of praseodymium(III) in spiked water samples.  相似文献   

5.
The two chromium chelates of Schiff bases, N-(acetoacetanilide)-1,2-diaminoethane (L1) and N,N′-bis(acetoacetanilide)-triethylenetetraammine (L2), have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Cr(III). The addition of lipophilic anion excluder (NaTPB) and various plasticizers viz. o-Nitrophenyloctyl ether (o-NPOE), dioctylpthalate (DOP), dibutylphthalate (DBP), tris(2-ethylhexyl)phosphate (TEHP), and benzyl acetate (BA) have found to improve the performance of the sensors. The best performance was obtained for the membrane sensor having a composition of L1:PVC:DBP:NaTPB in the ratio 5:150:250:3 (w/w). The sensor exhibits Nernstian response in the concentration range 8.9 × 10−8 to 1.0 × 10−1 M Cr3+ with limit of detection 5.6 × 10−8 M. The proposed sensor manifest advantages of relatively fast response (10 s) and good selectivity over some alkali, alkaline earth, transition and heavy metal ions. The selectivity behavior of the proposed electrode revealed a considerable improvement as compared to the best previously PVC-membrane electrode for chromium(III) ion. The potentiometric response of the proposed sensor was independent of pH of the test solution in the range of 2.0-7.0. The sensor has found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 3 months. The proposed electrode was used as an indicator electrode in potentiometric titration of chromium ion with EDTA and in direct determination in different water and food samples.  相似文献   

6.
Singh AK  Saxena P  Mehtab S  Gupta B 《Talanta》2006,69(2):521-526
A new PVC membrane electrode based on 5,7,12,14-dibenzo-2,3,9,10-tetraoxa-1,4,8,11-tetraazacyclotetradecane (I) as an ion carrier, o-nitrophenyloctyl ether (o-NPOE) as solvent mediator and sodium tetraphenylborate (NaTPB) as lipophilic additive was fabricated and investigated as Sr2+-selective electrode. The best performance was exhibited by the membrane having composition 8:200:4:120 (I:o-NPOE:NaTPB:PVC). The electrode exhibited a Nernstian response for strontium ion over a wide concentration range 3.98 × 10−6 to 1.0 × 10−1 M with a slope of 29.0 ± 0.1 mV/decade of concentration and a detection limit of 2.82 × 10−6 M. It showed a response time of less than 10 s and could be used for at least 3 months without any divergence in potential. The proposed electrode showed a good discriminating ability towards strontium(II) ion over a wide variety of other metal ions including alkali, alkaline earth, transition, and heavy metal ions. The electrode can be used in the pH range of 2.5-10.5 and in mixtures containing up to 35% (v/v) non-aqueous content. It was used as an indicator electrode in potentiometric titration of strontium ion against EDTA.  相似文献   

7.
The two macrocyclic pendant ligands 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetramethylacrylate-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-di ene (L1) and 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetra(2-cyano ethane)-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-diene (L2) have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Tb(III) ions. Effects of various plasticizers and anion excluders were studied in detail and improved performance was observed. The best performance was obtained for the membrane sensor having a composition of L1: PVC:1-CN:NaTPB in the ratio of 6: 32: 58: 4 (w/w; mg). The performance of the membrane based on L1 was compared with polymeric membrane electrode (PME) as well as with coated graphite electrode (CGE). The electrodes exhibit Nernstian slope for Tb3+ ions with limits of detection of 3.4 × 10−8 mol L−1 for PME and 5.7 × 10−9 mol L−1 for CGE. The response time for PME and CGE was found to be 10 s and 8 s, respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0-7.5 for PME and 2.0-8.5 for CGE. The CGE has found to work satisfactorily in partially non-aqueous media upto 30% (v/v) content of methanol, ethanol and 20% (v/v) content of acetonitrile and could be used for a period of 5 months. The CGE was used as indicator electrode in the potentiometric titration of Tb3+ ions with EDTA and in determination of fluoride ions in various samples. It can also be used in direct determination of Tb3+ ions in tap water and various binary mixtures with quantitative results.  相似文献   

8.
Zinc(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix   总被引:1,自引:0,他引:1  
Membranes of dibenzo-24-crown-8 (I) as an ion active material in poly(vinylchloride) (PVC) based matrix have been tried for zinc(II)-selective sensors. The effect of anion excluder, sodium tetraphenylborate (NaTPB) and plasticizers, tris(2-ethylhexyl)phosphate (TEP), tributylphosphate (TBP), dibutylphthalate (DBP), dibutyl(butyl)phosphonate (DBBP), 1-chloronaphthalene (CN) and dioctylphthalate (DOP) on the performance of the membrane electrodes has also been studied. It was observed that the membrane having the composition (I): PVC:NaTPB:DOP in the ratio 10:200:2:100 gave the best results with a wide working concentration range of 9.2 × 10−5 to 1.0 × 10−1 M, Nernstian slope of 29.0 ± 0. 5 mV/decade of activity, fast response time of 12 s and good selectivity over a number of mono-, bi-, and trivalent cations. The sensor works well in a pH range 4.8-6.2 and can be employed for the estimation of zinc ions in partially non-aqueous medium having up to 10% (v/v) methanol, ethanol or acetone content. The practical utility of the sensor has been demonstrated by using it successfully as an indicator electrode in the potentiometric titration of Zn2+ with EDTA and also for the determination of Zn2+ in a real sample analysis of wastewater.  相似文献   

9.
The iron(III) and cobalt(III) complexes of 2,3,7,8,12,13,17,18-octakis(benzylthio)-5,10,15,20-tetraazaporphyrin, (OBTAP) were synthesized and incorporated into PVC matrix as ionophores to fabricate anion selective membrane electrodes that exhibit selective potentiometric response to azide and nitrite ions, respectively. The membrane of [Fe(OBTAP)]+ (III) with a composition of 6:190:200 (III:DBP:PVC) (w/w), and of [Co(OBTAP)]+ (IV) with a composition of 10:148:200 (IV:DOP:PVC) (w/w), i.e. 1a and 2b, respectively (where DBP:dibutylphthalate and DOP=dioctylphthalate) gave the best performance. The membrane 1a showed a slope of 29.2±0.2 mV per decade of activity for N3 in the working concentration range of 8.9×10−6 to 1.0×10−1 M. The membrane 2b showed a slope of 30.0±0.2 mV per decade of activity for NO2 in the working concentration range of 1.1×10−5 to 1.0×10−1 M. The membranes worked satisfactorily in the pH range of 4.3-10.5 (1a) and 2.8-6.4 (2b) and had fast response time of 12±2 and 13±2 s, respectively. Electrodes exhibited a high degree of selectivity for N3 and NO2, respectively, over several other monovalent and bivalent anions. Only SCN and S2− (at >1.0×10−4 M) cause moderate interference for electrode 1a and Cl and S2− (at >1.0×10−5 M) for electrode 2b. They gave reproducible results with the relative standard deviation in the observed values of potentials (σ) of 1.96 and 1.80 mV for electrodes 1a and 2b, respectively, from the least-squares fit line. The 90% confidence limit lies within ±0.2 mV per decade of activity. Reproducible results were obtained over a period of 5 months. Their performance in non-aqueous solvent mixtures having up to 50% (v/v) methanol, ethanol and acetone were evaluated and were found satisfactory. The proposed sensors are superior in terms of detection limit and response time in comparison to the reported ones.  相似文献   

10.
A [{hydrotris(3-phenyl-5-methyl-1-pyrazolyl)borate}(3-phenyl-5-methyl-pyrazole) nickel chloride] [TpPh,MeNi(Cl)PzPh,MeH] (I) has been synthesized and explored as ionophores for the preparation of a poly (vinyl chloride) (PVC) membrane sensor for azide and thiocyanate anions. The compounds [TpPh,MeNi(N3)PzPh,MeH] (II) and [TpPh,MeNi(SCN)PzPh,MeH] (III) were characterized by their crystal structures and proved to be bonded as monodentate through nitrogen atom of azide and thiocyanate anion. Potentiometric investigations also indicate high affinity of this receptor for thiocyanate and azide ions. PVC based membranes of I using as hexadecyltrimethylammonium bromide (HTAB) cation discriminator and o-nitrophenyloctyl ether (o-NPOE), dibutylphthalate (DBP), acetophenone (AP) and tributylphosphate (TBP) as plasticizing solvent mediators were prepared and investigated as SCN and N3 selective sensors. The best performance was shown by the membrane of thiocyanate with composition (w/w) of (I) (7%):PVC (31%):DBP (60%):HTAB (2%). This sensor works well over a wide concentration range 5.3 × 10−7 to 1.0 × 10−2 M with Nernstian compliance (59.2 mV decade−1 of activity) within pH range 2.5-9.0 with a response time of 11 s and showed good selectivity for thiocyanate ion over a number of anions. The sensor exhibits adequate life (3 months) and could be used successfully for the determination of thiocyanate content in human urine, saliva and river water samples. While the membrane of [TpPh,MeNi(Cl)PzPh,MeH] ionophore with composition (I) (6%):HTAB (4%):PVC (31%):TBP (59%) showed highest sensitivity and widest linear range for azide ion. These sensors exhibit the maximum working concentration range of 8.1 × 10−6 to 1.0 × 10−2 M with Nernstian slope of 59.3 mV decade−1 of activity. It can be applied for the monitoring of the azide ions concentration in aqueous black tea and orange juice samples.  相似文献   

11.
Palladium sensors based on two neutral ionophores, N,N′-bis(acetylacetone) cyclohexanediamine (L1) and N,N′-bis(o-hydroxyacetophenone)-1,2-cyclohexanediamine (L2) for quantification of palladium ions are described. Effect of various plasticizers (o-NPOE, DBP, DEP, DOP, TBP, and CN) and anion excluder, sodium tetra phenyl borate (NaTPB) has been studied. The best performance is obtained with a membrane composition of PVC:o-NPOE:ionophore (L1):NaTPB of 150:300:5:5 (%, w/w). The sensor exhibits significantly enhanced selectivity towards palladium ion over the concentration range 1.0 × 10−8 to 1.0 × 10−1 M with a lower detection limit of 4.0 × 10−9 M and a Nernstian compliance (29.1 ± 0.3 mV decade−1 of activity) within pH range 2.0-6.0 and fast response time of 10 s. Influence of the membrane composition and possible interfering ions has also been investigated on the response properties of the electrode. Fast and stable response, good reproducibility and long-term stability of the sensor are demonstrated. The sensor has been found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 4 months. Selectivity coefficients determined with fixed interference method (FIM) indicate high selectivity for palladium. The proposed electrode shows fairly good discrimination of palladium from other cations. The application of prepared sensor has been demonstrated in determination of palladium ions in spiked water sample.  相似文献   

12.
The potentiometric response characteristics of mercury ion-selective membrane electrodes based on 2-amino-6-purinethiol (I1) and 5-amino-1, 3, 4-thiadiazole-2-thiol (I2) were described. Ion selectivities were tested for various plasticizers, which were used as solvent mediators to incorporate the ionophores into the membrane. Effects of experimental parameters such as membrane composition, nature and amount of plasticizers and additives, pH and concentration of internal solution on the potential response of Hg2+ electrodes were investigated. The best performance was obtained with the electrode having a membrane composition (w/w) of (I1) (3.17%): PVC (31.7%): DOP (dioctylpthalate) (63.4%): NaTPB (sodium tetraphenylborate) (1.58%). The proposed electrode reveals a Nernstian response over Hg2+ ion in the concentration range of 7.0 × 10−8-1.0 × 10−1 M with limit of detection 4.4 × 10−8 M. The electrode shows good discrimination toward Hg2+ ion with respect to most common cations. It shows a short response time (10 s) for whole concentration range and can be used for 2 months without any considerable divergence in potentials. For evaluation of the analytical applicability, the electrode was used in the determination of Hg2+ ion in different environmental and biological samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants.  相似文献   

13.
A new tripodal imidazolium ligand 2 comprising three 2,2′-bipyridine-imidazolium subunits connected through a mesityl spacer has been synthesized and 1:1 complexes of 2 with Fe(II) and Ru(II) ions have been prepared. 1H NMR spectroscopy including NOE analysis and molecular modeling study established that the complexes exist as a pseudocryptand type twisted structure in solution. The Fe(II) and Ru(II) complexes show strong 1:1 binding of Cl, Br, and I anions in MeCN-d3 with a large enhancement of the guest selectivity (Cl > Br > I) upon metal complexation.  相似文献   

14.
Ion-selective membrane electrodes doped with the urea- or thiourea-functionalised calix[4]arenes, 5,11,17,23-tetra-tert-butyl-25,27-bis[[4-N′-(phenylureido)butyl]oxy]-26,28-dipropoxy calix[4]arene (I) and 5,11,17,23-tetra-tert-butyl-25,27-bis[[4-(N′-phenylthioureido)-butyl]oxy]-26,28-dipropoxy calix[4]arene (II), were evaluated for anion sensing. Potentiometric results show that these calixarene ionophore-based membrane electrodes exhibit a good sensitivity to aqueous solutions of the monohydrogen orthophosphate species HPO42− in the concentration range 5.0 × 10−5 to 1.0 × 10−1 M, with near-Nernstian response slopes of −33.0 and −28.0 mV dec−1 for ionophores I and II, respectively. Selectivity coefficient values for monohydrogen orthophosphate over a range of common anions were determined by the fixed interference and matched potential methods and indicated that these membrane electrodes exhibit a good selectivity for HPO42− with respect to the other anions, including sulfate and nitrate.  相似文献   

15.
N,N′,N″,N′′′-1,5,8,12-tetraazadodecane-bis(salicylaldiminato)(H2L) has been used as ionophore for preparing Mn2+ selective sensor. Membranes of different composition with regard to ratio of H2L:PVC:NPOE:NaTPB have been prepared and investigated. The best performance was obtained with the membrane of composition 10:150:150:10 (H2L:PVC:NPOE:NaTPB) (w/w; mg). This membrane generated linear potential response in the concentration range of 5.0 × 10−6 to 1.0 × 10−1 M with a Nernstian slope of 30.0 mV/decade of activity and fast response time (10 s). Hydrogen ion does not effect to the performance of sensor in the pH range 3.0-6.5. The sensor was found to be sufficient selective for Mn2+ over a number of alkali, alkaline and heavy metal ions and could therefore be used for the determination of manganese in various samples by direct potentiometry.  相似文献   

16.
Al3+ selective sensor has been fabricated from poly(vinyl chloride) (PVC) matrix membranes containing neutral carrier morin as ionophore. Best performance was exhibited by the membrane having composition as morin:PVC:sodium tetraphenyl borate:tri-n-butylphosphate in the ratio 5:150:5:150 (w/w, mg). This membrane worked well over a wide activity range of 5.0 × 10−7 to 1.0 × 10−1 M of Al3+ with a Nernstian slope of 19.7 ± 0.1 mV/decade of Al3+ activity and a limit of detection 3.2 × 10−7 M. The response time of the sensor is ∼5 s and membrane could be used over a period of 2 months with good reproducibility. The proposed sensor works well over a pH range (3.5-5.0) and demonstrates good discriminating power over a number of mono-, di- and trivalent cations. The sensor can also be used in partially non-aqueous media having up to 20% (v/v) methanol, ethanol or acetone content with no significant change in the value of slope or working activity range. The sensor has also been used in the potentiometric titration of Al3+ with EDTA and for its determination in zinc plating mud and red mud.  相似文献   

17.
Lee HK  Song K  Ran Seo H  Jeon S 《Talanta》2004,62(2):293-297
Polymeric-membrane electrodes for NO3 anion based on (α,α,α,α)-5,10,15,20-tetrakis [2-(4-methylphenylurea)phenyl]porphyrin I and similar urea-functionalized porphyrins II-IV as neutral ionophores were prepared. The effects of polymeric-membrane composition and test solution pH were tested. The electrodes revealed good selectivity coefficients for NO3 over a wide variety of other anions, and the values of eight anions were measured. Of the various electrodes prepared, the electrode based on urea-functionalized porphyrin I exhibits a linear stable response over a wide concentration range (1.0×10−5 to 1.0×10−1) with a slope of −57.4 mV per decade, a detection limit of log[NO3]=−5.72, and a selectivity coefficient for nitrate against perchlorate anion ().  相似文献   

18.
A highly selective mercury electrode based on a diamine donor ligand   总被引:1,自引:0,他引:1  
Gupta VK  Chandra S  Lang H 《Talanta》2005,66(3):575-580
(H2NCHMeCH2NH2)(H2O)2HgCl2 (I) was synthesised, characterised and used for the fabrication of a potentiometric sensor for Hg2+ metal ions. Membrane having I as electroactive material, sodium tetraphenyl borate (NaTPB) as an anion excluder, dibutylamine (DBA) as plasticizer in PVC matrix in the percentage ratio of 10:3:150:150 (I:NaTPB:DBA:PVC) (w/w) exhibits a linear response to Hg2+ ions in a concentration range of 1.25 × 10−5 to 1.0 × 10−1 M having a detection limit of 8.9 × 10−6 with a slope of 25 ± 0.1 mV over the pH range 6.6-9.3. Selectivity coefficients for Hg(II) relative to a number of interfering ions were investigated. The electrode is highly selective for Hg2+ ions over a large number of mono-, bi-, and trivalent cations. Normal interferents like Ag+ and Cd2+ do not interfere in the working of the electrode. The electrode has also been used successfully in mixtures having a 10% (v/v) methanol and acetone content without showing any considerable change in working concentration range or slope. These electrodes have been found to be chemically inert showing a fast response time of 10 s and were used over a period of 4 months with good reproducibility (s = ±0.2). The electrode was used for determination of mercury in binary mixtures with 100% recovery and thus the proposed sensor can be used for real sample analysis.  相似文献   

19.
Novel ionophore, C-thiophenecalix[4]resorcinarene (I) has been synthesized and characterized by IR, NMR and C, H, N analysis. Poly(vinyl chloride) (PVC) based membranes of ionophore (I) using dibutylphthalate (DBP), dioctylphthalate (DOP), 1-chloronapthalene (CN), tris(2-ethylhexyl) phosphate (TEHP) and bis(2-ethylhexyl)sebacate (DOS) as plasticizing solvent mediators were prepared and used as Cr selective sensors. Of the various sensors prepared, the one with membrane composition 2:66:120 mg (I: PVC: DBP) exhibited the best performance. This sensor works well over a wide concentration range 5.6 × 10−6-1.0 × 10−1 M (detection limit ∼ 0.30 ppm) with Nernstian compliance (29.0 mV per decade) between pH 6.5-10.0 with a fast response time of ∼13 s. The selectivity coefficient values as determined by fixed interference method (FIM) indicate excellent selectivity for Cr ions over a large number of anions. The sensor exhibits adequate shelf-life ( ∼5 months) with good reproducibility (S.D. ± 0.2 mV). The sensor has been used in the potentiometric titration of chromate with Pb(II). Determination of chromium in electroplating waste using the sensor was successfully achieved.  相似文献   

20.
Three different derivatives of macrocyclic tetraimine Schiff's base have been synthesized and explored as a neutral ionophores for preparing poly(vinyl chloride) based membrane sensors selective to Dy3+. The addition of sodium tetraphenyl borate and various plasticizers, viz., o-NPOE, DBP, DBBP, DOP and CN has been found to substantially improve the performance of the sensors. The best performance was obtained with the sensor no. 1 having membrane of Schiff's base (SL-1) with composition (w/w) SL-1 (4.5%): PVC (30.5%): o-NPOE (59.5%): NaTPB (5.5%). This sensor exhibits Nernstian response with slope 19.4 mV/decade of activity in the concentration range of  10−8 to 1.0 × 10−2 M Dy3+, performs satisfactorily over wide pH range of (2.8-7.2) with a fast response time (10 s). The sensor was also found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of acetonitrile, methanol or ethanol. The proposed sensor can be used over a period of 1.5 months without significant drift in potentials. The sensor has been also utilized for the determination of Dy3+ level in different soil samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号