首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ten different digestion methods were investigated for the determination of arsenic in soils by hydride-generation atomic absorption spectrometry. These methods included a dry ashing/digestion, several acid-leaching procedures, and digestions in a pressure decomposition vessel or a Kjeldahl apparatus. A certified reference sample was analysed and the results obtained for five other soil samples were compared with the data obtained by spectrophotometry. A nitric/sulphuric acid digestion was the most suitable. A brief interference study is reported.  相似文献   

2.
Methods were developed for detailed dendrochemical studies of low sulphur contents in Norway spruce (Picea abies L. Karst.). This tree species is the dominant conifer species in Northern and Central Europe and therefore predestined for a possible use as an environmental archive. Two independent digestion procedures were investigated with respect to their suitability for element determination and optimised for analysis of the low sulphur content in wood. A modified oxygen bomb combustion procedure and a microwave acid digestion procedure were evaluated with the goal to obtain sufficient detection limits in order to access low concentrated non-metals with an appropriate time resolution. Method development included evaluation of strategies preventing losses of volatile sulphur species. Digestion efficiency was demonstrated by recovery rates for various certified plant standard reference materials (NIST 1572, NIST 1547, RM 8436, BCR 101, NIST 1515, RM 8436, NIST 1573, NIST 1575) as well as self prepared standards with defined low sulphur content of 20 to 200 mg kg?1, which are typical for Norway spruce wood samples. Ultra sonic nebulisation (USN) was evaluated with respect to signal enhancement for sample introduction to inductively coupled plasma optical emission spectrometry (ICP-OES). The optimised procedure was applied to Norway spruce drill cores from locations with different environmental conditions in Switzerland, in order to investigate the anthropogenic impact of sulphur and the suitability of Norway spruce as an environmental archive for sulphur.  相似文献   

3.
A procedure has been developed for the determination of bioavailable concentrations of selenium and arsenic in estuarine sediments employing inductively coupled plasma optical emission spectrometry (ICP OES) using a concomitant metals analyzer device to perform hydride generation. The optimization of hydride generation was done in two steps: using a two-level factorial design for preliminary evaluation of studied factors and a Doehlert design to assess the optimal experimental conditions for analysis. Interferences of transition metallic ions (Cd2+, Co2+, Cu2+, Fe3+ and Ni2+) to selenium and arsenic signals were minimized by using higher hydrochloric acid concentrations. In this way, the procedure allowed the determination of selenium and arsenic in sediments with a detection limit of 25 and 30 μg kg−1, respectively, assuming a 50-fold sample dilution (0.5 g sample extraction to 25 mL sample final volume). The precision, expressed as a relative standard deviation (% RSD, n = 10), was 0.2% for both selenium and arsenic in 200 μg L−1 solutions, which corresponds to 10 μg g−1 in sediment samples after acid extraction. Applying the proposed procedure, a linear range of 0.08-10 and 0.10-10 μg g−1 was obtained for selenium and arsenic, respectively. The developed procedure was validated by the analysis of two certified reference materials: industrial sludge (NIST 2782) and river sediment (NIST 8704). The results were in agreement with the certified values. The developed procedure was applied to evaluate the bioavailability of both elements in four sediment certified reference materials, in which there are not certified values for bioavailable fractions, and also in estuarine sediment samples collected in several sites of Guanabara Bay, an impacted environment in Rio de Janeiro, Brazil.  相似文献   

4.
A dry ashing procedure is developed for the determination of As in organic rich matrices such as wheat flour, lichen and tobacco leaves. The volatility of As during dry ashing is avoided by the addition of palladium nitrate [Pd(NO3)2]. The recovery of both As(III) and As(V) is found to be near quantitative. The residue after dry ashing is dissolved in nitric acid (HNO3) and analysed by inductively coupled plasma-mass spectrometry (ICP-MS). The process blank and limit of detection (LOD) are 11 and 6.6 ng g−1, respectively. The procedure is applied for the determination of As in certified reference materials namely wheat flour NIST SRM 1567a (National Institute of Standards and Technology Standard Reference Material), lichen BCR CRM 482 (Institute for Reference Materials, European Commission) and Virginia tobacco leaves CTA-VTL-2 (Poland Academy of Sciences). The results obtained by the present procedure are in good agreement with the certified values and also determined after complete dissolution of samples using closed microwave digestion.  相似文献   

5.
The development of an on-line preconcentration system with cloud point extraction for the determination of manganese is described. The system was used to determine manganese levels in food samples using flame atomic absorption spectrometry (FAAS). All steps of the cloud point extraction procedure were performed on-line, from the mixing of reagents to detection. The manganese ions are complexed in a mixture of the reagent 2-[2′-(6-methyl-benzothiazolylazo)]-4-bromophenol (Me-BTABr) and Triton X-114. The components are retained on a minicolumn and then desorbed with eluent acid to subsequent detection of manganese by FAAS. Under the optimized conditions, the method presented a detection limit of 0.7 μg L− 1 and an enrichment factor of 17 to a volume of 3000 μL. The sampling frequency was 30 h− 1. The accuracy of the method was tested by evaluating the amount of Mn in certified reference materials (apple leaves NIST 1515 and spinach leaves NIST 1570a). The proposed procedure was applied to food samples (shrimp powder, flaxseed flour, wheat flour, soy flour and oat), and the results agreed with those obtained by the determination of Mn in foods by atomic absorption spectrometry with electrothermal atomization (ETAAS).  相似文献   

6.
The present work evaluates the influence of vessel cooling simultaneously to microwave-assisted digestion performed in a closed system with diluted HNO3 under O2 pressure. The effect of outside air flow-rates (60–190 m3 h−1) used for cooling of digestion vessels was evaluated. An improvement in digestion efficiency caused by the reduction of HNO3 partial pressure was observed when using higher air flow-rate (190 m3 h−1), decreasing the residual carbon content for whole milk powder from 21.7 to 9.3% (lowest and highest air flow-rate, respectively). The use of high air flow-rate outside the digestion vessel resulted in a higher temperature gradient between liquid and gas phases inside the digestion vessel and improved the efficiency of sample digestion. Since a more pronounced temperature gradient was obtained, it contributed for increasing the condensation rate and thus allowed a reduction in the HNO3 partial pressure of the digestion vessel, which improved the regeneration of HNO3. An air flow-rate of 190 m3 h−1 was selected for digestion of animal fat, bovine liver, ground soybean, non fat milk powder, oregano leaves, potato starch and whole milk powder samples, and a standard reference material of apple leaves (NIST 1515), bovine liver (NIST 1577) and whole milk powder (NIST 8435) for further metals determination by inductively coupled plasma atomic emission spectroscopy (ICP-OES). Results were in agreement with certified values and no interferences caused by matrix effects during the determination step were observed.  相似文献   

7.
A microwave-assisted double insert multimode vapour-phase digestion method was developed for the digestion of organic samples. The experimental set-up was based on a third generation-type teflon microwave vessel, equipped with an automatic pressure regulating type vessel cover. A borosilicate glass holder insert, containing a smaller quartz sample insert, was fitted inside the vessel. Sulphuric acid was added to the holder insert as a microwave absorbing and temperature transferring liquid, which transferred heat to the sample insert (into which the sample was weighed) and charred the sample material. Oxidation of the sample material was carried out simultaneously with charring using nitric acid vapour, which was generated by the 1:1 (v/v) sulphuric acid-nitric acid mixture located in the bottom of the microwave vessel. This set-up generated high digestion efficiency, without any of the interferences normally associated with direct sulphuric acid usage. The method was used for determining the concentrations of Cd, Cr, Cu, Mn, Mo, Zn and Fe in certified organic reference materials using ICP-OES instrumentation. The certified organic reference materials were NRCC DOLT-2 dogfish liver, NIST-SRM 1577b bovine liver and IRMM VDA cadmium in polyethylene No. 001 and No. 004. The results were in good agreement with the certified values, forepart from Cd. For Cd the results were lower than the certified values due to volatilization losses. Sample materials that could not be digested by an earlier procedure were completely digested during a single-step, 30 min digestion. The tested sample materials included certified reference materials, 3-nitrobenzoic acid (3-NBA) and pike (Esox lucius) muscle. The residual carbon concentrations in the digestion solutions were below the detection limit of the TOC instrument. This type of digestion method is described here for the first time in the literature.  相似文献   

8.
A simple solid phase extraction procedure for speciation of selenium(IV) and selenium(VI) in environmental samples has been proposed prior to graphite furnace atomic absorption spectrometry. The method is based on the solid phase extraction of the selenium(IV)-ammonium pyrrolidine dithiocarbamate (APDC) chelate on the Diaion HP-2MG. After reduction of Se(VI) by heating the samples in the microwave oven with 4 mol l−1 HCl, the system was applied to the total selenium. Se(VI) was calculated as the difference between the total selenium content and Se(IV) content. The experimental parameters, pH, amounts of reagents, eluent type and sample volume were optimized. The recoveries of analytes were found greater than 95%. No appreciable matrix effects were observed. The adsorption capacity of sorbent was 5.20 mg g−1 Se (IV). The detection limit of Se (IV) (3sigma, n = 11) is 0.010 μg l−1. The preconcentration factor for the presented system was 100. The proposed method was applied to the speciation of selenium(IV), selenium(VI) and determination of total selenium in natural waters and microwave digested soil, garlic, onion, rice, wheat and hazelnut samples harvested various locations in Turkey with satisfactory results. In order to verify the accuracy of the method, certified reference materials (NIST SRM 2711 Montana Soil, NIST SRM 1568a Rice Flour and NIST SRM 8418 Wheat Gluten) were analyzed and the results obtained were in good agreement with the certified values. The relative errors and relative standard deviations were below 6 and 10%, respectively.  相似文献   

9.
A procedure for the determination of Cd and Zn in plants is proposed. The metals are extracted by pressurized fluid extraction (PFE). Operational conditions are: pressure 1500 psi, temperature 75 °C, static time 5 min, flush volume 35%, purge time 60 s, cycles 1 and 1,2-diaminocyclohexane-N,N,N′,N′-tetraacetic acid (CDTA) 0.01 M at pH 4.5 as extracting solution. Determination of Zn is carried out by flame atomic absorption spectroscopy and depending on the concentration level, Cd content is determined by flame or electrothermal atomic absorption spectroscopy. Certified samples of Virginia tobacco leaves, tea leaves, spinach leaves, poplar leaves, a commercial spinach sample (Spinacea oleracea) and genetically modified Arabidopsis thaliana were analysed by the proposed procedure and also by microwave acid digestion and extraction with HCl-Triton X-100. Confidence intervals for Cd and Zn content obtained by the proposed procedure overlap with the certified values. The other procedures, however, provide inaccurate results for Cd. Recoveries obtained for a confidence level of 95% are 96 ± 6% and 95 ± 5% for Zn and Cd, respectively. Reproducibility of Zn by the proposed procedure is 7% (n = 8), similar to the other tests and the detection limit is 2.6 μg. For Cd reproducibility is 8.5% (n = 8), better than with HCl-Triton X-100 and similar to acid digestion, the detection limit is 3.5 ng of Cd.  相似文献   

10.
11.
The evaluation of the use of alkaline peroxodisulfate digestion with low pressure microwave, autoclave or hot water bath heating for the determination of total phosphorus and nitrogen in turbid lake and river waters is described. The efficiency of these digestion procedures were compared to a Kjeldahl digestion procedure with sulphuric acid-potassium sulfate and copper sulfate. The final solution before digestion was 0.045 M in potassium peroxodisulfate and 0.04 M in sodium hydroxide. Procedures were evaluated by the analysis of suspensions of two reference materials, National Institute of Environmental Science, Japan, no. 3 Chlorella and no. 2 pond sediment and natural turbid waters. Best recoveries of phosphorus and nitrogen by microwave heating were obtained when solutions were digested at 95 °C for 40 min. Quantitative recoveries of phosphorus from Chlorella suspensions up to 1000 mg/l were obtained by all three heating procedures, but incomplete recoveries of nitrogen occurred above 20 mg N/l in the digested sample. Good recoveries of phosphorus and nitrogen from suspended sediment suspensions were obtained only from solutions containing <150 mg/l of suspended sediments. Recoveries of phosphorus from phosphorus compounds containing COP and CP bonds added to distilled water were quantitative (94-113%) except for polyphosphates (microwave, 34±8; autoclave, 114±6; water bath, 96±4) and aluminium phosphate (8-23%). Recoveries of nitrogen compounds containing CN bonds added to distilled water were quantitative (94-96%). The analysis of a range of natural turbid water samples by alkaline peroxodisulfate and microwave, autoclave and water bath heating gave similar total phosphorus and nitrogen results. All procedures using alkaline peroxodisulfate underestimate phosphorus concentrations at high suspended sediment concentrations (>150 mg/l) and are only suitable for the analysis of very turbid samples when the turbidity is due to organic matter (algal cells, plant detritus). Underestimation of nitrogen occurs when samples contain more than 20 mg N/l.  相似文献   

12.
A simultaneous multi-elemental measurement of As, Bi, Ge, Sb, Se, and Sn was performed in this study by flow injection-hydride generation-inductively coupled plasma-time-of-flight mass spectrometry (FI-HG-ICP-TOFMS). An off-line pre-reduction treatment using a solution of 5% (m/v) KI and ascorbic acid for 15 min at 80 °C is described by presenting its advantages and disadvantages and compared with the results achieved without pre-reduction. Using optimised conditions the following figures of merit were achieved: limits of detection in the 0.08-0.54 ng ml−1 range and relative standard deviations (RSD) of 1.7-6.7%, respectively. Applying the presented method, two certified reference materials (NIST 1643d freshwater and PACS-2 marine sediment) were analysed to demonstrate the suitability of the method for analysis of real samples. Results obtained from treated samples showed good agreement with certified values while the untreated ones considerably departed from them.  相似文献   

13.
A non-oxidative alkaline sample digestion procedure using tetramethylammonium hydroxide and a high pressure, microwave assisted autoclave digestion system was developed. The silicon concentrations of the digested samples were measured by inductively coupled axial plasma optical emission spectrometry (ICP-OES). Details of the digestion conditions as well as the optimised instrumental parameters for ICP-OES are described. The method was developed and tested using silicon-spiked ascorbic acid and applied to samples of animal tissue and organs. The total silicon content of two different reference materials, NIST 1577b Bovine liver and BCR 184 Bovine Muscle having neither certified nor informational values for Si was determined. The results obtained are compared with the results of independent methods such as wavelength dispersive x-ray fluorescence spectrometry (WDXRF) and solid sampling electrothermal atomic absorption spectrometry (ETAAS). The method described achieves a limit of detection of 2 mg kg–1 using 100 mg of solid biological or organic material and covers a concentration range of up to 500 mg kg–1. Received: 27 October 2000 / Revised: 31 January 2001 / Accepted: 2 February 2001  相似文献   

14.
In this work, the potential of graphite furnace atomic absorption spectrometry for the direct determination of B in plant tissues has been investigated. Three certified reference materials (NIST SRM 1570a spinach leaves, NIST SRM 1573a tomato leaves and BCR CRM 679 white cabbage) were selected for this study, the goal always being to develop a fast procedure that could be robust enough to provide a satisfactory performance for all of them, without any modifications in the conditions applied.The use of a suitable chemical modifier was found to be essential for obtaining a reproducible and sufficiently sensitive signal for boron solutions. In this regard, the performance of the combination of citric acid plus W (added as a permanent modifier) was noteworthy, resulting in well-defined signal profiles, a remarkable analyte stabilization during the pyrolysis step (up to 2100 °C) and minimal memory effects. This mixture of modifiers provided a good performance for the direct analysis of solid samples as well, but only if a suitable temperature program, favoring the interaction between the analyte and the modifiers, was used. Thus, such a temperature program, with two pyrolysis steps and the addition of NH4NO3 in order to carry out the in situ sample microdigestion, was optimized. Under these conditions, the peak areas obtained for both solid samples and aqueous standards were comparable.Finally, the analysis of the samples was carried out. In all cases, a good agreement with the certified values was obtained, while R.S.D. values ranged between 6 and 10%. It can be concluded that the method proposed shows significant advantages for the determination of this complicated element in solid samples such as the use of aqueous standards for calibration, a high sample throughput (20 min per sample), a suitable limit of detection (0.3 μg g−1) and reduced risk of analyte losses and contamination.  相似文献   

15.
A method is described for quantification of sulfur at low concentrations on the order of mg kg−1 in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at 32S and 34S related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg−1 S and 2.5 mg kg−1 S (in the sample). The LOD was constrained by instrument background counts at 32S but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 ± 0.13 mg kg−1. No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy.  相似文献   

16.
By use of the high separation capability of capillary electrophoresis (CE) and ultrasensitive chemiluminescence (CL) detection, a CE-CL method was proposed for the ultrasensitive determination of trace cobalt in a single hair, which is potentially useful in construction of the fingerprint of trace elements in the hair collected from crime scenes. In this work, the CE experimental conditions, CL experimental conditions and the digestion methods for the analysis of a single hair sample for cobalt were investigated in detail. The relative limit of detection (LOD, 3σ) was 0.01 ng/mL, and the absolute LOD was 2.4 × 10− 16 g considering the sampling volume of 24 nL. Using a dry digestion method, the analytical results for certified reference hair samples by the proposed method were in good agreement with the certified values. Finally, this method was successfully used to detect trace cobalt in a single hair from three adults. It has potential applications in forensic analysis.  相似文献   

17.
Baysal A  Akman S 《Talanta》2011,85(5):2662-2665
Sulphur in coal was determined using a high-resolution continuum source flame atomic absorption spectrophotometer (HR-CS-FAAS) with actylene/air flame. The C-S absorption band at 258.056 nm was found the most suitable analytical line with respect to sensitivity and spectral interferences. The instrumental parameters were optimized. The coal samples were dried and dissolved using microwave-assisted digestion technique. The validity of the method was tested using standard reference material and certified values were found in the limits of 95% confidence level. Since the concentrations of matrix elements of coal other than carbon are low enough not to cause any spectral interferences, the linear calibration method was applied in all quantifications without any problem. The calibration standards were prepared in sulphuric acid. The method was accurate, fast, simple and sensitive. The limit of detection (LOD, 3δ, N = 10) and the limit of quantification (LOQ, 10δ, N = 10) were found to be 0.01 and 0.03% (w/w), respectively. The sulphur concentrations of various kinds of the coal samples received around Turkey were determined. The sulphur contents of the coal samples were ranged from ≤LOQ to 1.2%.  相似文献   

18.
A novel and efficient digestion method based on choline chloride–oxalic acid (ChCl–Ox) deep eutectic solvent (DES) was developed for flame atomic absorption spectrometry (FAAS) determination of Cu, Zn, and Fe in biological fish samples. Key parameters that influence analyte recovery were investigated and optimized, using the fish protein certified reference material (CRM, DORM-3) throughout the procedure. In this method, 100 mg of the sample was dissolved in ChCl–Ox (1:2, molar ratio) at 100 °C for 45 min. Then, 5.0 mL HNO3 (1.0 M) was added. After centrifugation, the supernatant solution was filtered, diluted to a known volume, and analyzed by FAAS. Under optimized conditions, an excellent agreement between the obtained results and the certified values was observed, using Student's t-test (P = 0.05); the extraction recovery of the all elements was greater than 95.3%. The proposed method was successfully applied to the determination of analytes in different tissues (muscle, liver, and gills) having a broad concentration range in a marine fish sample. The reproducibility of the method was validated by analyzing all samples by our method in a different laboratory, using inductively coupled plasma optical emission spectrometry (ICP-OES). For comparison, a conventional acid digestion (CAD) method was also used for the determination of analytes in all studied samples. The simplicity of the proposed experimental procedure, high extraction efficiency, short analysis time, lack of concentrated acids and oxidizing agents, and the use of safe and inexpensive components demonstrate the high potential of ChCl–Ox (1:2) for routine trace metal analysis in biological samples.  相似文献   

19.
Electrothermal atomization of beryllium from graphite and tungsten surfaces was compared with and without the use of various chemical modifiers. Tungsten proved to be the best substrate, giving the more sensitive integrated atomic absorption signals of beryllium. Tungsten platform atomization with zirconium as a chemical modifier was used for the determination of beryllium in several NIST SRM certified reference samples, with good agreement obtained between the results found and the certified values. The precision of the measurements (at 10 μg L−1), the limit of detection (3σ), and the characteristic mass of beryllium were 2.50%, 0.009 μg L−1 and 0.42 pg, respectively.  相似文献   

20.
Oms MT  Cerdà A  Cerdà V 《Talanta》2003,59(2):319-326
An automatic method for the determination of total nitrogen in wastewater by sequential injection analysis and mineralization with UV radiation has been developed. The method is based on the mineralization of the samples with sodium persulphate in basic medium under UV radiation. Small volumes of sample and reagents are firstly aspirated into a single channel and then propelled by flow reversal to the UV reactor and then to the detector. The organic and inorganic nitrogen compounds are oxidized to nitrate that is then measured at 226 nm. The sequential injection procedure has been optimized and the factors affecting the efficiency of the oxidation have been studied with a number of test substances with different chemical structures and properties. Solutions in the concentration range 1-56 g l−1 of nitrogen can be analyzed with the described procedure. The sample rate is of 30-40 samples h−1. The LOD is 0.6 mg l−1 N and the reproducibility is 1.8% (28 mg l−1 N). Organic carbon in the form of glucose was added to a number of test solutions to study the potential interference of organic matter.The method was compared with the Kjeldahl digestion method by analyzing 15 wastewater samples with both methods. The nitrate and nitrite content of the non-oxidized samples were subtracted from the corresponding nitrogen content determined after photo-oxidation and the value compared with the Kjeldahl nitrogen content.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号