首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A sensitive and selective flow injection chemiluminescence (CL) method combined with controlled potential electrolysis technique was described for the determination of molybdenum. The method is based on the chemiluminescence reaction of luminol with unstable molybdenum(III) in alkaline solution. The molybdenum(III) was on-line reduced from molybdenum(VI) via controlled potential electrolysis technique using a homemade flow-through carbon electrolytic cell at the potential of −0.6 V (versus Ag/AgCl). The method allows the determination of molybdenum in the 5.0×10−10 to 5.0×10−7 g ml−1 range with a limit of detection (3σ) of 5×10−11 g ml−1 molybdenum. The relative standard deviation is 2.6% for the 1.0×10−9 g ml−1 molybdenum solution in 11 repeated measurements. This method was successfully applied to the determination of molybdenum in water samples.  相似文献   

2.
Monser L  Adhoum N  Sadok S 《Talanta》2004,62(2):389-394
A novel gas diffusion-flow injection method has been developed for the rapid and sensitive determination of total inorganic carbon (TIC) in water. The method is based on the diffusion of CO2 across gas permeable membrane from a donor stream containing 0.1 M HCl to an acceptor stream of sodium acetate (10−5 mol l−1 and pH 10). The CO2 trapped in the acceptor stream passes through an electrochemical flow cell contains a tungsten oxide wire and a silver/silver chloride electrode, where it was sensitively detected. The parameters affecting the sensitivity of the electrode such as buffer concentration, pH, flow rate and injected volume were studied in detail. The electrode response was linear in the concentration range from 5 to 100 μg ml−1 CO32− with a correlation coefficient (R2) of 0.998. Precision (R.S.D.) was 1.42% for 20 μg ml−1 standard solution of CO32− (n=10). The detection limit was 0.20 μg ml−1 CO32−. The method was evaluated by the injection of real natural water samples and an average recovery of 100.1% was obtained. The sampling rate was 30 samples h−1. The method is simple, feasible with satisfactory accuracy and precision and thus could be used for monitoring TIC in water.  相似文献   

3.
This paper describes a simple and highly selective method for the separation, preconcentration and spectrophotometric determination of extremely low concentration of mercury. The method is based on the flotation of an ion-associate of HgI42− and ferroin between aqueous and n-heptane interface at pH 5. The ion-associate was then separated and treated with ammonia and dithizone solutions to extract only the mercury chelate with CH2Cl2. The measurement is feasible when the volume of the water sample containing Hg(II) was varied over 50-800 ml. Beer's law was obeyed over the concentration range of 8 × 10−9 to 1.6 × 10−7 mol l−1 with an apparent molar absorptivity of 6.53 × 106 l mol−1 cm−1 for a 500 ml aliquot of the water sample. The detection limit (n = 7) was 5.0 × 10−10 mol l−1 and the R.S.D. (n = 5) for 8.0 × 10−7 mol l−1 of Hg(II) was 3.7%. A notable advantage of the method is that the determination of Hg(II) is free from the interference of almost all cations and anions found in the environmental and waste water samples. The determination of Hg(II) in tap, synthetic sea water and human hair samples was carried out by the present method and cold vapor atomic absorption spectrometry (CV-AAS). The results were satisfactorily comparable so that the applicability of the proposed method was confirmed to the real samples.  相似文献   

4.
Amir Waseem 《Talanta》2007,71(1):56-61
A flow injection (FI) method is reported for the determination of thyroxine based on its enhancement of chemiluminescence (CL) from the Ru(bpy)33+-NADH system. The calibration graph was linear over the range 2.0-10 × 10−8 mol L−1 (r2 = 0.9989) with relative standard deviations (R.S.D.) in the range 2.0-4.5% (n = 4). The limit of detection (3σ blank) was 1.0 × 10−9 mol L−1 with sample throughput of 120 h−1. The effect of some organic compounds, anions and cations were studied for l-thyroxine determination. The method was applied to pharmaceutical preparations and the results obtained were in reasonable agreement with the amount labeled. The method was statistically compared with the results obtained by RIA; no significant disagreement at 95% confidence limit was observed. A calibration graph of NADH over the range 1.3 × 10−8-1.3 × 10−6 mol L−1 was also established (r2 = 0.9992) with R.S.D. in the range1.0-3.5% (n = 4). The limit of detection (3σ) was 1.0 × 10−10 mol L−1 NADH.  相似文献   

5.
A direct method for the determination of citrate and oxytetracycline in samples containing complex matrices like tablets or serum has been developed using the luminescence of the ternary complex formed with Eu(III) ions. The triplet-state energy level of oxytetracycline (OxTc), the excitation maximum (412 nm) and the luminescence lifetime of Eu-OxTc (58 μs) were determined. A 17-fold luminescence enhancement at 615 nm occurs upon addition of citrate within a short 5-min incubation time at neutral pH. This is accompanied by a threefold increase of the luminescence decay time. The optimal conditions for determination of OxTc are equal concentrations of Eu (III) and citrate (C = 1 · 10− 4 mol L− 1) and pH 7.2. For determination of citrate, the optimal concentrations of Eu(III) and OxTc are 1 : 0.5 (CEu = 1 · 10− 4 mol L− 1, COxTc = 5 · 10− 5 mol L− 1) at pH 7.2. The linear range for determination of OxTc in serum is 0.25-250 μg mL− 1, and for citrate in tablets from 0.5 to 10.0 μg mL− 1 (2.3 · 10− 6- 4 · 10− 5 mol L− 1). The detection limit was 0.1 μg mL− 1 for OxTc and 0.2 μg mL− 1 (1 · 10-6 mol L− 1) for citrate, respectively. A comparison of the new method with other methods for determination of citrate is given.  相似文献   

6.
A simple flow injection gas/diffusion method for the determination of trimethylamine (TMA) in seafood with potentiometric detection using tungsten oxide electrode has been developed. The method is based on the diffusion of TMA through a PTFE membrane from a sodium hydroxide donor stream to a phosphate buffer acceptor stream. The TMA in the acceptor stream passes through an electrochemical flow cell containing a tungsten oxide wire and a silver/silver chloride electrode, where TMA was sensitively detected. The parameters affecting the sensitivity of the electrode such as sodium hydroxide concentration, buffer concentration, pH, flow rate and injected volume were studied in details. The electrode response was linear in the concentration range from 1 to 10 μg ml−1 TMA with a correlation coefficient (R2) of 0.991 and a detection limit of 0.05 μg ml−1 TMA. The intra- and inter-days precision (R.S.D.) was found to be, respectively, 1.20 and 1.6% (n=6). The method was applied to the determination of TMA in fish tissue and recoveries of 99-100% were obtained for fish extracts. Results were in close agreement with those obtained by the existing classical official method. Common interference from those species that can diffuse through the membrane were removed by the addition of formaldehyde to the seafood extract. The method is simple, feasible with satisfactory accuracy and precision and thus, could be used for monitoring seafood quality with a sampling rate of 20±2 sample h−1.  相似文献   

7.
Rui Liu  Maoyang Xi  Yi Lv 《Talanta》2009,78(3):885-635
Arsine trapping on resistively heated tungsten coil was investigated and an analytical method for ultratrace arsenic determination in environmental samples was established. Several chemical modifiers, including Re, Pt, Mo, Ta and Rh, were explored as permanent chemical modifiers for tungsten coil on-line trapping and Rh gave the best performance. Arsine was on-line trapped on Rh-coated tungsten coil at 640 °C, then released at 1930 °C and subsequently delivered to an atomic fluorescence spectrometer (AFS) by a mixture of Ar and H2 for measurement. In the medium of 2% (v/v) HCl and 3% (m/v) KBH4, arsine can be selectively generated from As(III). Total inorganic arsenic was determined after pre-reduction of As(V) to As(III) in 0.5% (m/v) thiourea-0.5% (m/v) ascorbic acid solution. The concentration of As(V) was calculated by difference between the total inorganic arsenic and As(III), and inorganic arsenic speciation was thus achieved. With 8 min on-line trapping, the limit of detection was 10 ng L−1 for As(III) and 9 ng L−1 for total As; and the precision was found to be <5% R.S.D. (n = 7) for 0.2 ng mL−1 As. The proposed method was successfully applied in total arsenic determination of several standard reference materials and inorganic arsenic speciation analysis of nature water samples.  相似文献   

8.
Mehretie S  Admassie S  Hunde T  Tessema M  Solomon T 《Talanta》2011,85(3):1376-1382
A sensitive and selective method was developed for the determination of N-acetyl-p-aminophenol (APAP) and p-aminophenol (PAP) using poly(3,4-ethylenedioxythiophene) (PEDOT)-modified glassy carbon electrode (GCE). Cyclic voltammetry and differential pulse voltammetry were used to investigate the electrochemical reaction of APAP and PAP at the modified electrode. Both APAP and PAP showed quasireversible redox reactions with formal potentials of 367 mV and 101 mV (vs. Ag/AgCl), respectively, in phosphate buffer solution of pH 7.0. The significant peak potential difference (266 mV) between APAP and PAP enabled the simultaneous determination both species based on differential pulse voltammetry. The voltammetric responses gave linear ranges of 1.0 × 10−6-1.0 × 10−4 mol L−1 and 4.0 × 10−6-3.2 × 10−4 mol L−1, with detection limits of 4.0 × 10−7 mol L−1 and 1.2 × 10−6 mol L−1 for APAP and PAP, respectively. The method was successfully applied for the determination of APAP and PAP in pharmaceutical formulations and biological samples.  相似文献   

9.
A novel flow-injection spectrophotometry has been developed for the determination of molybdenum(VI) at nanograms per milliliter levels. The method is based on the catalytic effect of molybdenum(VI) on the bromate oxidative coupling of p-hydrazinobenzenesulfonic acid with N-(1-naphthyl)ethylenediamine to form an azo dye (λmax = 530 nm). Chromotropic acid (4,5-dihydroxy-2,7-naphthalenedisulfonic acid) acted as an effective activator for the molybdenum(VI)-catalyzed reaction and increased the sensitivity of the method. The reaction was monitored by measuring the change in absorbance of the dye produced. The proposed method allowed the determination of molybdenum(VI) in the range 1.0-20 ng mL−1 with sample throughput of 15 h−1. The limit of detection was 0.5 ng mL−1 and a relative standard deviation for 10 ng mL−1 molybdenum(VI) (n = 10) was 2.5%. The interfering ions were eliminated by using the combination of a masking agent and on-line minicolumn packed with cation exchanger. The present method was successfully applied to the determination of molybdenum(VI) in plant foodstuffs.  相似文献   

10.
A flow-injection chemiluminescence (CL) method is described for the determination of fluoroquinolones including ciprofloxacin, norfloxacin and ofloxacin. The method is based on the enhancement by these compounds of the weak CL from peroxynitrous acid. The linear ranges are 1.0×10−7 to 1.0×10−5 mol l−1 for ciprofloxacin and norfloxacin, and 3.0×10−7 to 3.0×10−5 mol l−1 for ofloxacin, respectively. The detection limits (S/N=3) are 4.5×10−8 mol l−1 ciprofloxacin, 5.9×10−8 mol l−1 norfloxacin and 1.1×10−7 mol l−1 ofloxacin, respectively. The proposed method was applied to the determination of fluoroquinolones in pharmaceutical preparations.  相似文献   

11.
Xiang Y  Mei L  Li N  Tong A 《Analytica chimica acta》2007,581(1):132-136
A new fluorogenic method for the selective and sensitive determination of chromium(VI) in acidic water using rhodamine B hydrazide was developed. This method was based on the oxidation of non-fluorescent rhodamine B hydrazide by potassium dichromate in acidic aqueous conditions to give rhodamine B, which was highly fluorescent, as a product. With the optimum condition described, the fluorescence enhancement at 585 nm was linearly related to the concentration of chromium(VI) in the range of 5.0 × 10−8 to 2.0 × 10−6 mol L−1 (2.60-104 ng mL−1) with a correlation coefficient of R2 = 0.9993 (n = 18) and a detection limit of 5.5 × 10−9 mol L−1 (0.29 ng mL−1). The R.S.D. was 2.2% (n = 5). The proposed method was also applied to the determination of chromium(VI) in drinking water, river water and synthetic samples.  相似文献   

12.
A novel, sensitive and high selective flow-injection chemiluminescence (FI-CL) method for the determination of phenol is reported, based upon its decreasing effect on the CL reaction of luminol with hydrogen peroxide catalyzed by manganese (III) deuteroporphyrin [MnDP, Scheme 1, 3] in alkaline solution. Under the selected optimized experimental conditions, the relative CL intensity was linear with phenol in the range of 4.0 × 10−9 to 4.0 × 10−7 g mL−1. The detection limit (3σ) was 6.3 × 10−10 g mL−1 and the relative standard deviation for 1.0 × 10−7 g mL−1 phenol (n = 11) was 2.99%. The regression equation was I = 120.79 + 1.14 × 1010c (R = 0.9936). This method has been applied to the determination of phenol in water with satisfactory results.  相似文献   

13.
A sensitive method of Co(II) determination by adsorptive stripping voltammetry is presented. The method exploits the enhancement of cobalt peak current observed in the system Co(II)-nioxime-cetyltrimethylammonium bromide-piperazine-N,N′-bis(2-ethanesulfonic acid). The calibration plot for an accumulation time of 60 s is linear from 5 × 10−11 to 3 × 10−9 mol L−1. The relative standard deviation is 3.8% for Co(II) determination at concentration 1 × 10−9 mol L−1. The detection limit is 1.7 × 10−11 mol L−1. The validation of the method is performed by the analyses of certified reference materials and comparing the result of Co(II) determination in river water sample by the proposed method with those obtained by ET AAS. The main advantage of this new system is the micro-trace Co(II) determination by adsorptive stripping voltammetry, as compared to those described before, a low concentration of the supporting electrolyte used, and so commercially available reagents without additional purification can be used.  相似文献   

14.
Du J  Hao L  Li Y  Lu J 《Analytica chimica acta》2007,582(1):98-102
A simple flow injection chemiluminescence (FI-CL) method was proposed for the determination of nitrofurazone. Strong CL signal was generated during the reaction of nitrofurazone with H2O2 and N-bromosuccinimide (NBS) in alkaline condition. The CL signal was proportional to the nitrofurazone concentration in the range 1.0 × 10−7 to 1.0 × 10−5 g mL−1. The detection limit was 2 × 10−8 g mL−1 nitrofurazone and the relative standard deviation was less than 4% (6.0 × 10−6 g mL−1 nitrofurazone, n = 11). The proposed method was successfully applied to the determination of nitrofurazone in compound furacillin nasal drops, human plasma and urine samples. The CL reaction mechanism was also discussed briefly. Singlet oxygen generated in the reaction between H2O2 and NBS was suggested to be participated in the CL reaction.  相似文献   

15.
Li Y  Lu J 《Analytica chimica acta》2006,577(1):107-110
A simple, rapid and sensitive flow injection chemiluminescence (CL) method is described for the determination of naproxen. It was found that strong CL signal was generated when naproxen was mixed with KMnO4 and Na2SO3 in neutral aqueous medium. Under the optimum experimental conditions, the CL intensity was linearly related to the concentration of naproxen from 4.0 × 10−9 to 1.0 × 10−6 g mL−1 (r = 0.9993). The detection limit was 2 × 10−9 g mL−1 naproxen, the relative standard deviation for 1.0 × 10−7 g mL−1 naproxen solution was 1.5% (n = 11) and the sampling frequency was 120 h−1. The method was applied to the determination of naproxen in pharmaceutical preparation with satisfactory results. The mechanism of CL reaction was discussed briefly.  相似文献   

16.
Nie F  Wang N  Zheng J  Zhang J 《Talanta》2011,84(4):1063-1067
A strong post chemiluminescence (PCL) phenomenon was observed when ammonium was injected into the reaction mixture after the finish of CL reaction of N-bromosuccinimide (NBS) and dichlorofluorescein. Based on this, a sensitive flow injection PCL method was established for the determination of ammonium. The possible CL mechanism of the reaction was proposed based on a series of experiments. The PCL intensity responded linearly to the concentration of ammonium in the range 3.0 × 10−11-1.0 × 10−7 g mL−1 with a detection limit of 1 × 10−11 g mL−1. The relative standard deviation (R.S.D.) was 1.4% for 1.0 × 10−9 g mL−1 ammonium (n = 11). This method had been applied to the determination of ammonium in samples of mineral water, tap water and river water.  相似文献   

17.
A sensitive chemiluminescence (CL) method, based on the enhancive effect of cobalt(II) on the CL reaction between luminol and dissolved oxygen in a flow injection (FI) system, was proposed for determination of Vitamin B12. The increment of the CL intensity was proportional to the concentration of Vitamin B12, giving a calibration graph linear over the concentration from 2.0×10−10 to 1.2×10−6 g l−1 (r2=0.9992) with the detection limit of 5.0×10−11 g l−1 (3σ). At a flow rate of 2.0 ml min−1, a complete determination of Vitamin B12, including sampling and washing, could be accomplished in 0.5 min with the relative standard deviations (R.S.D.) of less than 5.0%. The proposed method was applied successfully to the determination of Vitamin B12 in pharmaceuticals, human serum, egg yolk and fish tissue.  相似文献   

18.
Di J  Bi S  Zhang F 《Talanta》2004,63(2):265-272
The electrochemical behavior of maltol on a glassy carbon (GC) electrode was investigated. The results were applied to differential pulse voltammetric determination of maltol in beverages pretreated by ultrafiltration. Under the optimum experimental conditions, the linear range is 1×10−5 to 6×10−4 mol l−1 maltol and the relative standard deviation for 0.4 mmol l−1 maltol is 0.6% (n=9). The detection limit was 5 μmol l−1. Furthermore, silica sol-gel film on GC electrode could be used as suitable selective membrane, which integrated selective membrane on the electrode and substituted for the pretreatment of ultrafiltration. Under the above conditions, maltol was determined by semi-differential linear sweep voltammetry at a silica sol-gel modified GC electrode in the concentration range of 5×10−6 to 5×10−4 mol l−1. The detection limit was 2 μmol l−1 and the relative standard deviation for 0.1 mmol l−1 maltol was 0.7% (n=7). The proposed method is of sensitivity, simplicity, rapidness and no contamination. It had been applied to the direct determination of maltol in beverages such as grape wines, drinks and beers without any pretreatment. The results obtained with the present method were satisfactory with those obtained by spectrophotometry. It could be used as a simple and practical method for the determination of the flavor enhancer maltol in beverages.  相似文献   

19.
Su Y  Wang J  Chen G 《Talanta》2005,65(2):531-536
Epinephrine was found to be able to strongly enhance the electrochemiluminescence (ECL) of lucigenin system by using the anodic potential sweep. Based on which, a novel ECL method for the determination of epinephrine was developed. Under the optimum condition, the enhanced ECL intensity was linear with the epinephrine concentration in the range of 4.0 × 10−8 to 2.0 × 10−7 mol L−1. The detection limit (defined as S/N = 3) was 2.4 × 10−8 mol L−1, and the relative standard deviation was 2.7% for 1.0 × 10−7 mol L−1 epinephrine (n = 11). The method was successfully applied to the determination of epinephrine in pharmaceutical samples with satisfactory results. In addition, the possible mechanism for the lucigenin ECL system in the presence of epinephrine has also been discussed.  相似文献   

20.
Zhengjun G  Xinshen Z  Guohe C  Xinfeng X 《Talanta》2005,66(4):1012-1017
A simple, accurate, sensitive and selective flow injection catalytic kinetic spectrophotometric method for rapid determination of trace amounts of selenium is proposed in this paper. The proposed method is based on the accelerating effect of Se(IV) on the reaction of ethexlenediamine tetrecetic acid disodium salt (EDTA) and sodium nitrate with ammonium iron(II) sulfate hexahydrate in acidic media. The absorbance intensity was registered in this reaction solution at 440 nm. The calibration graph is linear in the range of 5 × 10−9-2 × 10−7 and 2 × 10−7-2 × 10−6 g ml−1. The detection limit is 2 × 10−9 g ml−1. The relative standard deviation was 3.4% for 5 × 10−8 g ml−1 Se(IV) (n = 11), 2.7% for 5 × 10−7 g ml−1 Se(IV) (n = 11). This method is very simple, rapid and suitable for automatic and continuous analysis. The presented system has been applied successfully to determination of Se(IV) of seawater samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号