首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
简化柱切换技术在高浓度基体存在下测定痕量离子的研究   总被引:1,自引:0,他引:1  
黄源  牟世芬 《色谱》2000,18(2):95-99
 建立了适用于高浓度基体存在下测定痕量离子的简化柱切换技术。通过分析淋洗液浓度对待测离子色谱峰保留时间的影响 ,指出可使用高浓度淋洗液抑制色谱峰漂移 ,并通过实验案例提出了针对不同样品采取的不同策略。  相似文献   

2.
秦永平  邹远高  梁茂植  余勤 《分析化学》2004,32(9):1216-1218
采用柱切换技术 荧光检测反相高效液相色谱法测定血浆中特布他林 (TB)浓度。使用LunaC8( 2 )和KromasilC18为分析柱 ( 1 5 0mm× 4.6mm ,5 μm)和预处理柱 ( 2 5mm× 4.6mm ,5 μm) ,流动相分别为pH 3 0 ,0 .0 3 3mol/L磷酸盐缓冲液∶甲醇∶乙腈 ( 92∶7∶1 )和水∶甲醇∶乙腈 ( 97∶2∶1 ) ,流速均为 1 .0ml/L。血浆样品经乙腈沉淀蛋白后进样 ,切换时间为 3 .2~ 4.2min。荧光检测 ,λex为 2 80nm ,λem为 3 0 9nm。以沙丁胺醇作内标 ,按内标法定量。标准曲线线性范围为 0 .8~ 3 2 μg/L ;最低定量限为 0 .8μg/L;TB和内标的保留时间分别为 8.7和 9.3min;日内RSD小于 4% ,日间RSD小于 9% ,方法回收率在 93 %~ 1 1 2 %。  相似文献   

3.
An automated high performance liquid chromatography with column-switching and ultraviolet detection was developed for the analysis of risperidone and 9-hydroxyrisperidone. The method needs minimum sample preparation and is useful for the detection down to a limit of 1 ng mL−1. Sample clean-up of serum was carried out on a CN 20 μm SPE-column using 8% (v/v) acetonitrile in water. Chromatographic separation was performed on ODS Hypersil C18 material with 38% (v/v) acetonitrile and 0.4% (v/v) TEMED in water. Application of the method to the analysis of serum samples confirmed its suitability for therapeutic drug monitoring of risperidone and 9-hydroxyrisperidone.  相似文献   

4.
建立一种检测饮用水中痕量溴酸盐的离子色谱方法。利用On GuardⅡAg柱过滤去除水中氯离子,直接进样,电导检测器检测。该方法避免了氯离子对溴酸盐的干扰,测定水质溴酸盐的灵敏度和准确度均有很大提高。溴酸盐的检出限为0.005 mg/L,测定结果的相对标准偏差为7.56%(n=7),加标回收率为92.0%~110.0%。该方法操作简便快速、准确度高,适合于饮用水中痕量溴酸盐的测定。  相似文献   

5.
抑制型电导检测离子色谱法测定饮用水中的痕量溴酸盐   总被引:4,自引:1,他引:3  
应波  李淑敏  岳银玲  鄂学礼 《色谱》2006,24(3):302-304
建立一种直接进样测定饮用水中痕量溴酸盐的电导检测离子色谱法。选用Metrosep A Supp 5阴离子交换分离柱,碳酸盐淋洗液。抑制型电导检测采用化学抑制器和CO2抑制器顺序双抑制系统。实验结果显示,溴酸根阴离子与常见共存阴离子完全分离,溴酸盐含量在5~100 μg/L范围内具有良好的线性(r=0.9999),精密度高(相对标准偏差(RSD)<4%),方法的检出限为0.50 μg/L,样品加标平均回收率为96.1%~107%。该方法操作简单,分离效果好,可与常见阴离子实现同时分析,灵敏度高,重现性好,可作为饮用水中溴酸盐的标准测定方法。  相似文献   

6.
7.
实验发现偏二甲肼(UDMH)在溴酸钾-鲁米诺化学发光反应体系中的后化学发光反应.在对这一后化学发光反应的动力学性质、发光条件,包括溴酸钾浓度、鲁米诺浓度、管长、流速和酸碱度条件等研究的基础上,建立了后化学发光反应法测定偏二甲肼的新方法,并讨论了其可能的反应机理.该方法的线性范围为1.0×10-7~1.0×10-5g/L...  相似文献   

8.
The critical micellar concentration (cmc) is a fundamental property of surfactant solutions. Many proposed methods for the definition and determination of the cmc from property-concentration plots yield values, which depend on the studied property, on the specific technique used for its analysis and in many cases on the subjective choice of the chosen type of plot and concentration interval. In this focus review, we revise the application of a surfactant concentration model we proposed earlier that defines the cmc directly based on the surfactant concentration. Known equations for the concentration-dependence of different surfactant properties can then be combined with this concentration model and fitted to experimental data. This modular concept makes it possible to determine the cmc and the transition width in a systematic and unambiguous way. We revise its use in the literature in different contexts: the determination of the cmc of surfactants and their mixtures from different properties (electrical conductivity, NMR chemical shift, self-diffusion, surface tension, UV-Vis absorption, fluorescence intensity and fluorescence correlation). We also revise the dependence of the width of the transition region on composition, detailed studies of the properties of fluorescent probes and the aggregation of non-surfactant systems, namely amyloid peptides.  相似文献   

9.
采用在线Sweeping(推扫 )富集技术 ,建立了胶束毛细管电泳法测定血液中痕量乳酸环丙沙星的方法。考察了背景溶液pH值、SDS浓度、进样时间、血样预处理方法等对乳酸环丙沙星富集效果的影响。使用未涂层的毛细管柱 (5 5cm× 75 μmi.d .,有效柱长 4 7cm) ,30mmol/L硼砂 +80mmol/L十二烷基硫酸钠 (pH =9.4 0 )为背景溶液 ,在紫外检测波长 2 5 4nm、运行电压 1 8kV条件下 ,血浆样品用乙腈除蛋白后直接在线Sweep ing富集 ,富集倍数可达 6 0 0倍。线性范围在 0 .0 4~ 1 0mg/L (r =0 .999,n =8)。检出限为 0 .0 1mg/L。本方法减少了样品预处理的繁琐过程 ,弥补了毛细管电泳 (CE)在测定血液中痕量组分方面的不足 ,为CE在体内痕量药物分析等方面的应用提供了新的方法  相似文献   

10.
 A novel catalytic procedure for zirconium was proposed based on Zr(IV) catalyzed oxidation of gallocyanine by hydrogen peroxide in hexamethylene tetramine-hydrochloric acid buffer medium. The calibration graph is linear for 0–110 ngċml−1, and the detection limit is 0.4 ngċml−1 Zr(IV). Most foreign ions do not interfere with the determination, except for Cu2+, Fe3+ and Cr(VI). The interferences of Cu2+ and Fe3+ could be eliminated by masking with EDTA and mannitol, and that of Cr(VI) by reducing to Cr(III) with ascorbic acid. The typical features of this procedure are that it is sensitive for zirconium, and the determination could be carried out at room temperature. It had been used to the determination of zirconium in zirconium bronze, simulated samples and a certified reference material. The recoveries were 98.6 ∼ 102%, and relative standard deviations (R.S.D.) were 0.9 ∼ 1.5%, respectively. Received September 12, 1999. Revision April 10, 2000.  相似文献   

11.
在硫酸介质中,亚硝酸盐对溴酸钾氧化苯胺蓝褪色反应有明显的催化作用,据此提出了测定痕量亚硝酸盐催化分光光度方法。优化的试验条件如下:1 1.0mol·L-1硫酸溶液的用量为1.8mL;2 3×10-4 mol·L-1苯胺蓝溶液用量为1.5mL;3 0.02mol·L-1溴酸钾溶液用量为1.1mL;4反应温度为30℃。该方法的线性范围分别为0.01~0.2mg·L-1和0.2~1.0mg·L-1,检出限(3s/k)为4.6×10-6g·L-1。方法用于水样的分析,回收率在96.0%~104%之间,测定值的相对标准偏差(n=6)在1.6%~2.3%之间。  相似文献   

12.
微波浓缩-离子法测定饮用水中的痕量溴酸根和高氯酸根   总被引:26,自引:0,他引:26  
刘勇建  牟世芬  杜兵  林爱武 《色谱》2002,20(2):129-132
 建立了一种简便的用于浓缩水中痕量BrO3 -和ClO4 -的样品前处理方法。水样经OnGuardAg柱过滤 ,用微波炉在 15min内可浓缩 2 0倍 ,所测离子的回收率均高于 90 %。又采用IonPacAS16型亲水性柱 ,用 15 0 μL定量环 ,以NaOH为流动相、梯度淋洗方式 ,在 35min内测定了包括BrO3 -和ClO4 -在内的 8种离子。BrO3 -和ClO4 -的检测限分别为 0 10 μg/L和 0 2 0 μg/L。该方法在实际应用中有较大的参考价值。  相似文献   

13.
锂金属二次电池具有极高的能量密度,是下一代储能电池的研究热点。然而,金属锂负极在传统碳酸酯电解液1 mol·L?1 LiPF6-EC/DEC(ethylene carbonate/diethyl carbonate)中充放电时,存在严重的枝晶生长和循环效率低下等问题,阻碍了其商业化应用。因此,开发与锂负极兼容的新型电解液体系是目前重要的研究任务。与传统稀溶液相比,高浓度电解液体系具有独有的物化性质和优异的界面相容性,并且能有效抑制锂枝晶生长、显著提升锂负极的循环可逆性,因而格外受到关注。本文综述了高浓度电解液及局部高浓电解液体系的最新研究进展,分析了其溶液化学结构和物化性质,对其与锂负极的界面相容性、枝晶抑制效果、效率提升能力及界面稳定性机制进行了探讨;文章着重介绍了高浓与局部高浓电解液体系在锂金属二次电池中的应用,同时从基础科学研究和应用研究两个层面对高浓电解液和局部高浓电解液存在的主要问题进行了简要分析,并对其未来发展方向进行了展望。  相似文献   

14.
建立以大体积进样(250μL)–离子色谱测定水中溴酸盐(BrO_3~–)的方法。采用Ag柱离线去除样品中大量Cl~–以消除Cl~–干扰,同时保证痕量溴酸盐未沉淀,过滤后直接进样测定。BrO_3~–的质量浓度在2.0~25.0μg/L范围内与色谱峰面积呈良好的线性关系,线性相关系数r=0.999 2,方法检出限为0.8μg/L。自来水和矿泉水样品3浓度水平加标回收率为85.0%~101.0%,测定结果的相对标准偏差为3.6%~12.9%(n=6)。该方法样品处理简单,检出限低,准确度和精密度高,满足分析测试的要求。  相似文献   

15.
试验者为小细胞肺癌患者,于右上臂皮下植入缓释VP-16(又称依托泊苷或鬼臼乙叉苷),按预定时间点采集静脉血并分离出血浆。血浆样品以氯仿萃取,常温下负压挥发至干,然后以流动相溶解,采用反相高效液相色谱法测定。流动相为V(甲醇)∶V(水)=52∶48的溶液,检测波长为UV-228 nm,色谱柱为Lichrosphere C18(250 mmX4.6 mm i.d.,5 μm)。用外标法定量。实验结果表明,该测定方法的检出限为0.02 mg/L,绝对回收率为80.4%,相对回收率为94.7%,日内和日间精密  相似文献   

16.
A very simple and rapid radiochemical method for the determination of 0.01—1 mcg of lead has been developed. It consists of adding carrier-free 2 1 2 Pb to the analysed sample, followed by shaking with a standard lead diethyldithiocarbamate solution in carbon tetrachloride. The amount of non-active lead in the sample is determined from activities of the organic and aqueous phases. A 10-fold excess of bismuth and more than 50–100-fold excess of other metals extractable as diethyldithiocarbamates do not interfere in the determination.  相似文献   

17.
在酸性介质条件下,钒(Ⅳ)能显著催化溴酸钾对二甲酚橙的氧化褪色反应。据此建立了测定痕量钒(Ⅳ)的顺序注射催化光度法。方法的线性范围为0.550ng/mL、检出限为0.4ng/mL。对10ng/mL的钒(Ⅳ)连续11次测定的相对标准偏差为1.1%。用于环境水样中痕量钒(Ⅳ)的测定,加标回收率为91%50ng/mL、检出限为0.4ng/mL。对10ng/mL的钒(Ⅳ)连续11次测定的相对标准偏差为1.1%。用于环境水样中痕量钒(Ⅳ)的测定,加标回收率为91%108%。  相似文献   

18.
乔明曦  郭兴杰  李发美 《色谱》2001,19(4):329-329
 用高效迎头分析法 (HPFA)测定了药物 人血清白蛋白 (HSA)混合液中游离药物的浓度。样品溶液不经任何处理直接进样到装有内表面反相固定相的色谱柱中 ,用 67mmol/L磷酸盐缓冲液 ( pH 7 4 ,I =0 17mol/L)作流动相。当进样体积足够大时 ,游离药物以平顶峰的形式被洗脱出来 ,平顶峰区域洗脱液中的药物浓度等于样品溶液中游离药物的浓度。收集平顶峰区域的洗脱液 ,然后将一定体积的洗脱液注入到反相色谱柱中 ,测定游离药物的浓度。用该法测定酮基布洛芬 HSA和头孢哌酮 HSA两种混合液中游离药物的浓度。  相似文献   

19.
研究了在稀硫酸介质中,亚硝酸根催化溴酸钾氧化甲酚红褪色反应的适宜条件和影响因素,建立了测定痕量亚硝酸根的方法.方法的线性范围为8.0~140 μg·L-1,检出限为0.98 μg·L-1,方法用于水样中亚硝酸根的测定,RSD为1.9%~3.1%.  相似文献   

20.
柱前衍生化高效液相色谱法(HPLC)测定水中微量溴酸盐含量   总被引:1,自引:0,他引:1  
联合柱前衍生化技术,成功地用高效液相色谱法(HPLC)测定了水体中微量溴酸盐含量。通过衍生化条件的优化,方法回收率在98%~105%之间、相对标准偏差RSD小于2.0%,线性相关系数达0.9995,检测限为1.0μg/L。方法简便快速、准确可靠,能满足现有标准的检测要求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号