首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The photodetachment of electrons from gaseous SH? ions has been studied in an ion cyclotron resonance mass spectrometer using a flashlamp-pumped organic dye laser as a light source. The onset of the photodetachment process at 538.7 ± 0.3 nm (2.3016 ± 0.0013 eV, 18563 ± 10 cm?1) agrees well with that obtained in an earlier study. Coarse structure in the photodetachment curve with a spacing of 11.8 nm (0.052 eV, 422 cm?1) has been identified with spin-orbit coupling in the SH. radical. Finer structure, with a spacing of ca. 2.5 nm (0.011 eV, 89 cm?1), has also been observed in the curve, but remains unexplained.  相似文献   

2.
Suspended trapping is used to eject electrons in negative-ion Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometric experiments. In contrast to electron ejection by resonant excitation of the trapping motion, suspended trapping involves allowing the electrons to escape along the z-axis (perpendicular to the trap plates) while the trapping potential is briefly removed. The duration of this event is sufficiently short (~10 μs) so that ion losses are negligible; the overall effect is that of a ‘high-pass mass filter’. Suspended trapping is simpler to implement and more generally applicable to various cell geometries than resonant electron ejection. The effectiveness of the suspended trapping technique is not compromised by the anharmonicity of the potential well in ‘elongated’ ICR traps, but depends simply on the time it takes the electrons to escape the cell. Finally, a small, positive offset potential (~+0.25 V) applied to the trap plates during the suspended trapping event increases the efficiency of the ejection.  相似文献   

3.
In electrospray ionization (ESI) quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry, certain fragment ions (e.g. acylium ions) generated either during the ion transportation process (in the source interface region) or in the ion trap are found to undergo ion--molecule reactions with ESI solvent molecules (water, acetonitrile and aliphatic alcohols) to form adduct species. These unexpected solvated fragment ions severely complicate the interpretation of mass spectrometic data. High-resolution accurate mass measurements are important in establishing the elemental compositions of these adduct species and preventing erroneous data interpretation.  相似文献   

4.
The resolving power of the low energy ion scattering technique with FT-ICR spectrometry is discussed. Resolution improvement due to simultaneous registration of scattered ions with different masses is shown.  相似文献   

5.
The dissociative excitation reaction of BrCN induced by the products of the electron cyclotron resonance (ECR) plasma flow of He was studied based on the electrostatic-probe measurements and on the optical emission spectra of the B2Σ+ − X2Σ+ transition of CN radicals. The partial pressures of He and BrCN were 3 and 1 mTorr, respectively, and the partial pressure of H2O, PH2O, was in the range of 0.0–0.6 mTorr. The electron density, ne, showed a negative dependence on PH2O as (2.63 ± 0.13) × 1012 − (0.23 ± 0.10) × 1012 m−3, and the electron temperature, Te, a positive dependence, (2.38 ± 0.36) − (4.51 ± 0.15) eV. The CN(B2Σ+ − X2Σ+) emission intensity showed a negative dependence on PH2O. Based on a kinetic analysis of these PH2O dependencies, the decomposition of BrCN does not proceed via electron impact; instead, decomposition proceeds via the processes involving He+ and/or He metastable atoms.  相似文献   

6.
We present a numerical method for computation of electrostatic (trapping) and time-varying (excitation) electric fields and the resulting ion trajectory and detected time-domain-induced voltage signal in a rectangular (or cubic) ion cyclotron resonance (ICR) ion trap. The electric potential is calculated by use of the superposition principle and relaxation method with a large number of grid points (e.g., 100 × 100 × 100 for a cubic trap). Complex ICR experiments and spectra may now be simulated with high accuracy. Ion trajectories may be obtained for any combination of trapping and excitation modes, including quadrupolar or cubic trapping in static or dynamic mode; and dipolar, quadrupolar, or parametric excitation with single-frequency, frequency-sweep (chirp), or stored waveform inverse Fourier transform waveforms. The resulting ion trajectory may be represented either as its three dimensional spatial path or as two-dimensional plots of x-, y-, or z-position, velocity, or kinetic energy versus time in the absence or presence of excitation. Induced current is calculated by use of the reciprocity principle, and simulated ICR mass spectra are generated by Fourier transform of the corresponding time-domain voltage signal.  相似文献   

7.
The ionization efficiency of an electron cyclotron resonance ion source (ECRIS) is generally high, and all elements can be fundamentally ionized by the high-temperature plasma. We focused our attention on the high potentiality of ECRIS as an ion source for mass spectrometers and attempted to customize the mass spectrometer equipped with an ECRIS. Precise measurements were performed by using an ECRIS that was specialized and customized for elemental analysis. By using the charge-state distribution and the isotope ratio, the problem of overlap such as that observed in the spectra of isobars could be solved without any significant improvement in the mass resolution. When the isotope anomaly (or serious mass discrimination effect) was not observed in ECR plasma, the system was found to be very effective for isotope analysis. In this paper, based on the spectrum (ion current as a function of an analyzing magnet current) results of low charged state distributions (2+, 3+, 4+, ...) of noble gases, we discuss the feasibility of an elemental analysis system employing an ECRIS, particularly for isotopic analysis. The high-performance isotopic analysis obtained for ECRIS mass spectrometer in this study suggests that it can be widely applied to several fields of scientific study that require elemental or isotopic analyses with high sensitivity.  相似文献   

8.
We describe a method for tuning electrically compensated ion cyclotron resonance (ICR) traps by tracking the observed cyclotron frequency of an ion cloud at different oscillation mode amplitudes. Although we have used this method to tune the compensation voltages of a custom-built electrically compensated trap, the approach is applicable to other designs that incorporate electrical compensation. To evaluate the effectiveness of tuning, we examined the frequency shift as a function of cyclotron orbit size at different z-mode oscillation amplitudes. The cyclotron frequencies varied initially by ∼12 ppm for ions with low z-mode oscillation amplitudes compared with those with high z-mode amplitudes. This frequency difference decreased to ∼1 ppm by one iteration of trap tuning.  相似文献   

9.
Evidence has been reported that primary loss of H and of HCN from the molecular ions of propionitrile, isobutyronitrile and butyronitrile in the mass spectrometer is preferentially preceded by hydrogen migration from C-2 to C-1. Ion cyclotron double resonance spectra of proton (or deuteron-) transfer products derived from propionitrile-2-d2 and -3-d3 and a series of bases provide evidence that such migration occurs also in long-lived propionitrile molecular ions.  相似文献   

10.
Hot electrons confined in a Penning trap at 3 tesla self-cool to near room temperature in a few seconds by emission of cyclotron radiation. Here, we show that such cold electrons can “sympathetically” cool, in ~10 s, laser desorbed/ionized translationally hot Au? or C70 ? ions confined simultaneously in the same Penning trap. Unlike “buffer gas” cooling by collisions between ions and neutral gas molecules, sympathetic cooling by electrons is mediated by the mutual long-range Coulomb interaction between electrons and ions, so that translationally hot ions can be cooled without internal excitation and fragmentation. It is proposed that electrosprayed multiply charged macromolecular ions can be cooled sympathetically, in the absence of ion-neutral collisions, by self-cooled electrons in a Penning trap.  相似文献   

11.
New low-energy electron injection systems based on indirectly heated dispenser cathodes facilitate electron capture dissociation (ECD) in Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. In this joint report, details are presented of the design and performance of these systems on two commercial FTICR instruments, 9.4 T Bruker BioAPEX in Uppsala and 4.7 T IonSpec Ultima in Odense. New results include obtaining meaningful one-scan MS/MS data for isolated precursor ions with millisecond irradiation times. The ECD rate improvement is not only due to the larger total electron current, but the larger emitting area as well.  相似文献   

12.
Electron capture dissociation (ECD) efficiency has typically been lower than for other dissociation techniques. Here we characterize experimental factors that limit ECD and seek to improve its efficiency. Efficiency of precursor to product ion conversion was measured for a range of peptide (∼15% efficiency) and protein (∼33% efficiency) ions of differing sizes and charge states. Conversion of precursor ions to products depends on electron irradiation period and maximizes at ∼5–30 ms. The optimal irradiation period scales inversely with charge state. We demonstrate that reflection of electrons through the ICR cell is more efficient and robust than a single pass, because electrons can cool to the optimal energy for capture, which allows for a wide range of initial electron energy. Further, efficient ECD with reflected electrons requires only a short (∼500 μs) irradiation period followed by an appropriate delay for cooling and interaction. Reflection of the electron beam results in electrons trapped in or near the ICR cell and thus requires a brief (∼50 μs) purge for successful mass spectral acquisition. Further electron irradiation of refractory precursor ions did not result in further dissociation. Possibly the ion cloud and electron beam are misaligned radially, or the electron beam diameter may be smaller than that of the ion cloud such that remaining precursor ions do not overlap with the electron beam. Several ion manipulation techniques and use of a large, movable dispenser cathode reduce the possibility that misalignment of the ion and electron beams limits ECD efficiency.  相似文献   

13.
This short review summarizes recent and projected advances in Fourier transform ion cyclotron resonance mass spectrometry instrumentation and applications, ranging from petroleomics to proteomics. More details are available from the cited primary literature and topical reviews.  相似文献   

14.
To improve the analytical usefulness of Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), an extensive survey of various methods for quantitation of peak magnitudes has been undertaken using a series of simulated transient response signals with varying signal-to-noise ratio. Both peak height (five methods) and peak area (four methods) were explored for a range of conditions to determine the optimum methodology for quantitation. Variables included dataset size, apodization function, damping constant, and zero filling. Based on the results obtained, recommended procedures for optimal quantitation include: apodization using a function appropriate for the peak height ratios observed in the spectrum (i.e., Hanning for ratios of about 1:10, three-term Blackman-Harris for ratios of ~1:100, or Kaiser-Bessel for ratios of ~1:1000); zero filling until the peaks of interest are represented by 10–15 points (generally obtained with one order of zero filling); and use of the polynomial y=(ax 2+bx+c) n and the three data points of highest intensity of the peak to locate the peak maximum, Y max=(?b 2/4a+c) n . In this peak fitting procedure, which we have termed the “Comisarow method,” n is 5.5, 9.5, and 12.5 for the Hanning, three-term Blackman-Harris, and Kaiser-Bessel apodization functions, respectively. Accuracy of quantitation using an optimal peak height determination is about equal to that for peak area measurements. These recommendations were found to be valid when tested with real FTICR-MS spectra of xenon isotopes.  相似文献   

15.
The analytical utility of the electron capture dissociation (ECD) technique, developed by McLafferty and co-workers, has substantially improved peptide and protein characterization using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The limitations of the first ECD implementations on commercial instruments were eliminated by the employment of low-energy electron-injection systems based on indirectly heated dispenser cathodes. In particular, the ECD rate and reliability were greatly increased, enabling the combination of ECD/FTICR-MS with on-line liquid separation techniques. Further technique development allowed the combination of two rapid fragmentation techniques, high-rate ECD and infrared multiphoton dissociation (IRMPD), in a single experimental configuration. Simultaneous and consecutive irradiations of trapped ions with electrons and photons extended the possibilities for ion activation/dissociation and led to improved peptide and protein characterization. The application of high-rate ECD/FTICR-MS has demonstrated its power and unique capabilities in top-down sequencing of peptides and proteins, including characterization of post-translational modifications, improved sequencing of peptides with multiple disulfide bridges and secondary fragmentation (w-ion formation). Analysis of peptide mixtures has been accomplished using high-rate ECD in bottom-up mass spectrometry based on mixture separation by liquid chromatography and capillary electrophoresis. This paper summarizes the current impact of high-rate ECD/FTICR-MS for top-down and bottom-up mass spectrometry of peptides and proteins.  相似文献   

16.
An electron injection system based on an indirectly heated ring-shaped dispenser cathode has been developed and installed in a 7 Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. This new hardware design allows high-rate electron capture dissociation (ECD) to be carried out by a hollow electron beam coaxial with the ion cyclotron resonance (ICR) trap. Infrared multiphoton dissociation (IRMPD) can also be performed with an on-axis IR-laser beam passing through a hole at the centre of the dispenser cathode. Electron and photon irradiation times of the order of 100 ms are required for efficient ECD and IRMPD, respectively. As ECD and IRMPD generate fragments of different types (mostly c, z and b, y, respectively), complementary structural information that improves the characterization of peptides and proteins by FTICR mass spectrometry can be obtained. The developed technique enables the consecutive or simultaneous use of the ECD and IRMPD methods within a single FTICR experimental sequence and on the same ensemble of trapped ions in multistage tandem (MS/MS/MS or MS(n)) mass spectrometry. Flexible changing between ECD and IRMPD should present advantages for the analysis of protein digests separated by liquid chromatography prior to FTICRMS. Furthermore, ion activation by either electron or laser irradiation prior to, as well as after, dissociation by IRMPD or ECD increases the efficiency of ion fragmentation, including the w-type fragment ion formation, and improves sequencing of peptides with multiple disulfide bridges. The developed instrumental configuration is essential for combined ECD and IRMPD on FTICR mass spectrometers with limited access into the ICR trap.  相似文献   

17.
Kweon HK  Håkansson K 《The Analyst》2006,131(2):275-280
Electron capture dissociation (ECD) has been proposed to be a non-ergodic process, i.e. to provide backbone dissociation of gas-phase peptides faster than randomization of the imparted energy. One potential consequence could be that ECD can fragment deuterated peptides without causing hydrogen scrambling and thereby provide amino acid residue-specific amide hydrogen exchange rates. Such a feature would improve the resolution of approaches involving solution-phase amide hydrogen exchange combined with mass spectrometry for protein structural characterization. Here, we explore this hypothesis using melittin, a haemolytic polypeptide from bee venom, as our model system. Exchange rates in methanol calculated from consecutive c-type ion pairs show some correlation with previous NMR data: the amide hydrogens of leucine 13 and alanine 15, located at the unstructured kink surrounding proline 14 in the melittin structure adopted in methanol, appear as fast exchangers and the amide hydrogens of leucine 16 and lysine 23, buried within the helical regions of melittin, appear as slow exchangers. However, calculations based on c-type ions for other amide hydrogens do not correlate well with NMR data, and evidence for deuterium scrambling in ECD was obtained from z*-type ions.  相似文献   

18.
19.
In two-dimensional Fourier transform ion cyclotron resonance mass spectrometry (2D FTICR-MS), scintillation noise, caused mostly by fluctuations in the number of ions in the ICR cell, is the leading cause for errors in spectrum interpretation. In this study, we adapted an algorithm based on singular value decomposition and first introduced by Cadzow et al. (IEE Proceedings Pt. F 1987, 134, 69) to 2D FTICR-MS and we measured its performance in terms of noise reduction without losing signal information in the 2D mass spectrum.  相似文献   

20.
Previous mass spectrometers based on the ion cyclotron resonance principle have employed continuous excitation (single-pulse or frequency-sweep), With detection during (frequency-sweep) or after (single-pulse or frequency sweep) the excitation. The present paper introduces an experiment in which an ion is first excited to a Larger orbit by continuous excitation, and then “de-excited” back to its starting point. The effect is demonstrated for the C9F20N+ peak (m/z = 502) in the Fourier transform ion cyclotron mass spectrum of perfluorotributylamine. By choosing which ion m/z ratios are “de-excited”, it should be possible to generate mass “windows” within which ions experience no net excitation. Potential applications of the method include the generation of an excitation with sharply defined “windows” or “steps”, with major advantages for MS/MS or multiple-ion-monitoring experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号