共查询到20条相似文献,搜索用时 15 毫秒
1.
A fast, simple, inexpensive, sensitive, efficient and environmental friendly direct ultrasound-assisted dispersive liquid-liquid microextraction (DUSA-DLLME) procedure has been developed to concentrate five nitroaromatic explosives from water samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). An efficient ultrasonic probe has been used to radiate directly the samples producing very fine emulsions from immiscible liquids. A D-optimal design was used for optimizing the factors and to evaluate their influential upon extraction. The optimum experimental conditions were: sample volume, 10 mL; extraction time, 60 s; cycles, 0.6 s(s−1); power of ultrasound energy, 40% (70 W); and, extractant solvent (chlorobenzene) volume, 20 μL. Under the optimized experimental conditions the method presents good level of repeatability with coefficients of variation under 6% (n = 8; spiking level 10 μg L−1). Calculated calibration curves gave high level of linearity with correlation coefficient values between 0.9949 and 0.9992. Limits of detection were ranged between 0.03 and 0.91 μg L−1. Finally, the proposed method was applied to the analysis of two types of water samples, reservoir and effluent wastewater. The samples were previously analysed and confirmed free of target analytes. At 5 μg L−1 spiking level recovery values ranged between 75 and 96% for reservoir water sample showing that the matrix had a negligible effect upon extraction. However, a noticeable matrix effect (around 50% recovery) was observed for effluent wastewater sample. In order to alleviate this matrix effect, the standard addition calibration method was used for quantitative determination. This calibration method supplied recovery values ranged between 71 and 79%. The same conclusions have been obtained from an uncertainty budget evaluation study. 相似文献
2.
This paper describes a rapid and solvent-free method, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for the extraction of six commonly used synthetic polycyclic musks: galaxolide (HHCB), tonalide (AHTN), celestolide (ADBI), traseolide (ATII), cashmeran (DPMI) and phantolide (AHMI) from water samples prior to their determination using gas chromatography-mass spectrometry (GC-MS). The effects of various extraction parameters for the quantitative extraction of these analytes by MA-HS-SPME were systematically investigated and optimized. The analytes in a 20-mL water sample (in a 40-mL sample-vial containing 4 g of NaCl) were efficiently extracted by a polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber placed in the headspace when the system was microwave irradiated at 180 W for less than 4 min. The limits of detection (LODs) ranged from 0.05 to 0.1 ng/L, and the limits of quantification (LOQs) were less than 0.2 ng/L. A preliminary analysis of wastewater samples revealed that HHCB and AHTN were the two most commonly detected synthetic polycyclic musks; using a standard addition method, their concentration were determined to range from 1.2 to 37.3 ng/L with relative standard deviation (RSD) ranging from 2 to 6%. The results obtained using this approach are better than those from the conventional oil-bath HS-SPME. 相似文献
3.
A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid–liquid microextraction (USADLLME) procedure has been developed to preconcentrate geosmin and 2-methylisoborneol (MIB) from water and wine samples prior to quantification by gas chromatography–mass spectrometry (GC–MS). A two-stage multivariate optimization approach was developed by means of a Plackett–Burman design for screening and selecting the significant variables involved in the USADLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: solvent volume, 8 μL; solvent type: tetrachloroethylene; sample volume, 12 mL; centrifugation speed, 2300 rpm; extraction temperature 20 °C; extraction time, 3 min; and centrifugation time, 3 min. Under the optimized experimental conditions the method gave good levels of repeatability with coefficient of variation under 11% (n = 10). Limits of detection were 2 and 9 ng L−1 for geosmin and MIB, respectively. Calculated calibration curves gave high levels of linearity with correlation coefficient values of 0.9988 and 0.9994 for geosmin and MIB, respectively. Finally, the proposed method was applied to the analysis of two water (reservoir and tap) samples and three wine (red, rose and white) samples. The samples were previously analyzed and confirmed free of target analytes. Recovery values ranged between 70 and 113% at two spiking levels (0.25 μg L−1 and 30 ng L−1) showing that the matrix had a negligible effect upon extraction. Only red wine showed a noticeable matrix effect (70–72% recovery). Similar conclusions have been obtained from an uncertainty budget evaluation study. 相似文献
4.
A rapid and simple dispersive liquid-liquid microextraction (DLLME) has been developed to preconcentrate eighteen organochlorine pesticides (OCPs) from water samples prior to analysis by gas chromatography-mass spectrometry (GC-MS). The studied variables were extraction solvent type and volume, disperser solvent type and volume, aqueous sample volume and temperature. The optimum experimental conditions of the proposed DLLME method were: a mixture of 10 μL tetrachloroethylene (extraction solvent) and 1 mL acetone (disperser solvent) exposed for 30 s to 10 mL of the aqueous sample at room temperature (20 °C). Centrifugation of cloudy solution was carried out at 2300 rpm for 3 min to allow phases separation. Finally, 2 μL of extractant was recovered and injected into the GC-MS instrument. Under the optimum conditions, the enrichment factors ranged between 46 and 316. The calculated calibration curves gave a high-level linearity for all target analytes with correlation coefficients ranging between 0.9967 and 0.9999. The repeatability of the proposed method, expressed as relative standard deviation, varied between 5% and 15% (n = 8), and the detection limits were in the range of 1-25 ng L−1. The LOD values obtained are able to detect these OCPs in aqueous matrices as required by EPA methods 525.2 and 625. Analysis of spiked real water samples revealed that the matrix had no effect on extraction for river, surface and tap waters; however, urban wastewater sample shown a little effect for five out of eighteen analytes. 相似文献
5.
分散液液微萃取-在线衍生化-气相色谱-质谱联用法检测环境水样品中紫外吸收剂 总被引:1,自引:0,他引:1
建立了分散液液微萃取(dispersive liquid-liquid microextraction,DLLME)-在线衍生化-气相色谱-质谱(GC-MS)方法,将其用于环境水中6种二苯甲酮类紫外吸收剂(BPs)(二苯甲酮、2,4-二羟基二苯甲酮、2-羟基-4-甲氧基二苯甲酮、4-羟基二苯甲酮、2-羟基-4-辛氧基二苯甲酮、2,2'-二羟基-4,4'-二甲氧基二苯甲酮)的检测。系统优化了在线衍生化的条件(如进样口温度、不分流时间、衍生化试剂用量)以及DLLME萃取条件(如萃取剂种类、分散剂种类、萃取剂与分散剂比例、样品体积、样品溶液离子强度及pH值)等。在最优的条件下,所考察的6种BPs检出限为0.011~0.15 μg/L,重现性(RSD)为0.7%~16.6%。该方法结果准确可靠,操作简单,富集效果好,成本较低,环境友好,在实际样品检测中具有一定的应用前景。 相似文献
6.
A simple and rapid new dispersive liquid-liquid microextraction technique (DLLME) coupled with gas chromatography-ion trap mass spectrometric detection (GC-MS) was developed for the extraction and analysis of triazine herbicides from water samples. In this method, a mixture of 12.0 microL chlorobenzene (extraction solvent) and 1.00 mL acetone (disperser solvent) is rapidly injected by syringe into the 5.00 mL water sample containing 4% (w/v) sodium chloride. In this process, triazines in the water sample are extracted into the fine droplets of chlorobenzene. After centrifuging for 5 min at 6000 rpm, the fine droplets of chlorobenzene are sedimented in the bottom of the conical test tube (8.0+/-0.3 microL). The settled phase (2.0 microL) is collected and injected into the GC-MS for separation and determination of triazines. Some important parameters, viz, type of extraction solvent, identity and volume of disperser solvent, extraction time, and salt effect, which affect on DLLME were studied. Under optimum conditions the enrichment factors and extraction recoveries were high and ranged between 151-722 and 24.2-115.6%, respectively. The linear range was wide (0.2-200 microg L(-1)) and the limits of detection were between 0.021 and 0.12 microg L(-1) for most of the analytes. The relative standard deviations (RSDs) for 5.00 microg L(-1) of triazines in water were in the range of 1.36-8.67%. The performance of the method was checked by analysis of river and tap water samples, and the relative recoveries of triazines from river and tap water at a spiking level of 5.0 microg L(-1) were 85.2-114.5% and 87.8-119.4%, respectively. This method was also compared with solid-phase microextraction (SPME) and hollow fiber protected liquid-phase microextraction (HFP-LPME) methods. DLLME is a very simple and rapid method, requiring less than 3 min. It also has high enrichment factors and recoveries for the extraction of triazines from water. 相似文献
7.
顶空固相微萃取-气相色谱-质谱联用测定香水中5种合成麝香 总被引:1,自引:0,他引:1
建立了香水中5种合成麝香的顶空固相微萃取-气相色谱-质谱联用分析方法。实验选用65 μm的聚二甲基硅氧烷-二乙烯基苯(PDMS-DVB)萃取纤维,在磁力搅拌600 r/min条件下,考察了萃取温度、平衡时间、萃取时间、解吸时间、进样口温度和盐效应6个方面对实验结果的影响。优化后的条件为: 10 mL顶空瓶中加入适量用水稀释过的样品,于60 ℃平衡3 min后,顶空萃取20 min,随即插入气相色谱进样口,于250 ℃解吸3 min进行定性、定量分析。5种合成麝香在0.05~1.00 μg/g范围内线性关系良好,检出限(LOD)为0.6~2.1 ng/g。空白样品在3个浓度加标水平下(0.05, 0.50, 1.00 μg/g)的回收率为82.0%~103.3%,相对标准偏差(RSD)为1.8%~9.4%。本方法简便、准确、快速、灵敏,适用于香水中合成麝香的分析检验工作。 相似文献
8.
Determination of volatile phenols in red wines by dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry detection 总被引:2,自引:0,他引:2
A new method was developed for analysing 4-ethylguaiacol and 4-ethylphenol in the aroma of red wines using dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry detection (GC-MS). Parameters such as extraction solvent, sample volume and disperser solvent were studied and optimised to obtain the best extraction results with the minimum interference from other substances, thus giving clean chromatograms. The response linearity was studied in the usual concentration ranges of analytes in wines (50-1500 microg/L). Repeatability and reproducibility of this method were lower than 5% for both volatile phenols. Limits of detection and limits of quantification were also determined, and the values found were 28 and 95 microg/L for 4-ethylguaiacol and 44 and 147 microg/L for 4-ethylphenol, respectively. This new method has been used for the determination of the volatile phenols concentration in different samples of Tannat wine affected by Brettanomyces contamination. 相似文献
9.
分散液液微萃取/气相色谱-质谱法测定蜂蜜中六六六和滴滴涕类农药残留 总被引:1,自引:0,他引:1
建立了分散液液微萃取(DLLME)与气相色谱-质谱法(GC-MS)联用快速检测蜂蜜中六六六(BHC)和滴滴涕(DDT)类农药残留的分析方法.使用三氯甲烷为萃取剂,通过涡旋、离心使分析物富集到微量三氯甲烷中,采用气相色谱-质谱进行分析.实验对影响DLLME萃取效率的因素,如萃取剂种类和体积、分散剂种类和体积、萃取时间等进行了考察,同时对方法的基质效应和性能进行了评估.结果显示:由于基质效应,8种六六六和滴滴涕类农药都出现信号增强现象.8种六六六和滴滴涕类农药在2~500 μg/L范围内线性关系良好,相关系数(r2)为0.991~0.998,方法富集倍数为74~96;当试样的加标水平为20、50和100 μg/kg时,8种六六六和滴滴涕类农药的回收率为61.0%~100.1%,相对标准偏差(RSD, n=5)为2.2%~19.5%.8种六六六和滴滴涕类农药的最低检测浓度均为20 μg/kg,最小检出量皆为1.0 ng.该方法简单、快速、高效,适用于蜂蜜中六六六和滴滴涕类农药的残留检测. 相似文献
10.
A new, simple, fast and high sensitive analytical method based on dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of nitro musks in surface water and wastewater samples is presented. Different parameters, such as the nature and volume of both the extraction and disperser solvents and the ionic strength and pH of the aqueous donor phase, were optimized. Under the selected conditions (injection of a mixture of 1 mL of acetone as disperser solvent and 50 μL of chloroform as extraction solvent, no salt addition and no pH adjustment) the figures of merit of the proposed DLLME-GC-MS method were evaluated. High enrichment factors, ranging between 230 and 314 depending on the target analyte, were achieved, which redound to limits of detection in the ng L−1 range (i.e., 4-33 ng L−1). The relative standard deviation (RSD) was below 5% for all the target analytes. Finally, the recoveries obtained for different water samples of diverse origin (sea, river, irrigation channel and water treatment plant) ranged between 87 and 116%, thus showing no matrix effects. 相似文献
11.
建立了液液萃取-分散液液微萃取-气相色谱-质谱联用技术测定纺织废水中痕量偶氮染料的方法。废水中的偶氮染料在碱性条件下经连二亚硫酸钠还原成芳香胺后,先用叔丁基甲醚液液萃取、盐酸反萃进行预浓缩及净化;再以乙腈-氯苯体系进行分散液液微萃取,气相色谱-质谱测定。对前处理条件进行了优化,考察了酸碱度及盐效应对芳香胺萃取效率的影响,结果表明:液液萃取过程中加入30 g NaCl,分散液液微萃取过程中加入1 mL 5 mol/L的NaOH调节体系至碱性才能达到较好的萃取效率。在优化的实验条件下,21种目标物均呈现良好的线性关系,其中13种芳香胺的线性范围为0.05~10μg/L, 7种芳香胺的线性范围为0.05~5μg/L, 2,4-二氨基苯甲醚的线性范围为20~100μg/L,相关系数为0.996~0.999。20种芳香胺的检出限可达0.05μg/L, 2,4-二氨基苯甲醚检出限为20μg/L。印染、机织、印花等实际废水加标试验表明,方法的回收率为75.6%~115.1%。该方法富集倍数高,检出限低,适用于纺织废水中痕量禁用偶氮染料的检测。 相似文献
12.
Determination of phenylurea herbicides in aqueous samples using partitioned dispersive liquid-liquid microextraction 总被引:1,自引:0,他引:1
Tso-Ying Chou 《Talanta》2009,80(2):493-9119
Partitioned dispersive liquid-liquid microextraction (PDLLME), using THF as the dispersive solvent and dichloromethane as the extraction solvent, was utilized to isolate and concentrate phenylurea herbicides (PUHs) from aqueous samples. In PDLLME, a dispersive solvent should be able to partition in the organic extractant droplets to effectively extract the polar organic compounds from aqueous samples. The mixture of the water-immiscible extractant and the partitioned dispersive solvent was obtained by centrifugation, dried under low pressure, reconstituted in methanol-water mixture (1:1), and injected into a HPLC system for the determination of PUHs. The enrichment factors of the PUHs ranged from 68 to 126 under the optimal conditions. The linear range was 0.5-100 ng ml−1 for each analyte, the relative standard deviations of PUHs were in the range of 1.5-5.9% (n = 5), and the detection limits (signal-to-noise ratio of 3) ranged from 0.10 to 0.28 ng ml−1 for the herbicides. The range of intraday precision (n = 5) for PUHs at the levels of 0.5, 5, and 50 ng ml−1 were 3.0-5.9%, 1.8-3.3%, and 2.2-3.6%, respectively. The range of interday precision (n = 5) at 0.5, 5, and 50 ng ml−1 were 0.4-1.8%, 1.2-2.4%, and 0.9-2.3%, respectively. The recoveries of PUHs from three spiked river water samples, at a level of 10 ng ml−1, were 91.2-104.1%. Due to its rapidity, ease of operation, and high recovery, PDLLME can be utilized to isolate and concentrate organic environmental contaminants such as PUHs from aqueous samples. 相似文献
13.
Campillo N Viñas P Martínez-Castillo N Hernández-Córdoba M 《Journal of chromatography. A》2011,1218(14):1815-1821
Microwave-assisted extraction (MAE) and dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) were evaluated for use in the extraction and preconcentration of volatile nitrosamines in meat products. Parameters affecting MAE, such as the extraction solvent used, and DLLME, including the nature and volume of the extracting and disperser solvents, extraction time, salt addition and centrifugation time, were optimized. In the MAE method, 0.25g of sample mass was extracted in 10mL NaOH (0.05M) in a closed-vessel system. For DLLME, 1.5mL of methanol (disperser solvent) containing 20μL of carbon tetrachloride (extraction solvent) was rapidly injected by syringe into 5mL of the sample extract solution (previously adjusted to pH 6), thereby forming a cloudy solution. Phase separation was performed by centrifugation, and a volume of 3μL of the sedimented phase was analyzed by GC-MS. The enrichment factors provided by DLLME varied from 220 to 342 for N-nitrosodiethylamine and N-nitrosopiperidine, respectively. The matrix effect was evaluated for different samples, and it was concluded that sample quantification can be carried out by aqueous calibration. Under the optimized conditions, detection limits ranged from 0.003 to 0.014ngmL(-1) for NPIP and NMEA, respectively (0.12-0.56ngg(-1) in the meat products). 相似文献
14.
An ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the extraction of US EPA 16 polycyclic aromatic hydrocarbons (PAHs) in 10 mL of water samples, with subsequent determination by gas chromatography-mass spectrometry (GC-MS). After determination of the most suitable solvent and solvent volume, several other parameters (i.e., extraction time, centrifugation time and ionic strength of the sample) were optimized using a 23 factorial experimental design. Limits of detection ranged from 0.001 to 0.036 μg L−1. The developed procedure was applied to fortified distilled water with different fortification levels (0.5, 2 and 5 μg L−1). Recoveries were over 92% and relative standard deviations of the recoveries were below 8%. The efficiency of the USAEME was compared with traditional liquid-liquid extraction (LLE) and solid-phase extraction on real water samples (i.e., tap water, well water and surface (lake) water as well as domestic and industrial wastewaters). The USAEME showed comparable efficiencies especially with LLE. The developed USAEME was demonstrated to be robust, viable, simple, rapid and easy to use for the determination of PAHs in water samples by GC-MS. 相似文献
15.
M. Y. Cheh H. C. Chua F. B. Hopkins J. R. Riches C. M. Timperley H. S. Nancy Lee 《Analytical and bioanalytical chemistry》2014,406(21):5103-5110
The applicability of hollow-fibre liquid-phase microextraction for extracting 2-chlorovinyldichloroarsine (lewisite 1), bis(2-chlorovinyl)chloroarsine (lewisite 2), tris(2-chlorovinyl)arsine (lewisite 3) and arsenic trichloride from aqueous samples is reported. Parameters affecting the extraction efficiency of these chemicals were optimised. These parameters included the type of derivatising agent, extraction solvent, derivatisation method, pH, ionic strength, stirring speed and extraction time. A linear range between 0.002 and 0.2 μg/mL was established for the lewisites with good square regression coefficients (0.9955–0.9992). Good reproducibility with relative standard deviations (RSDs) from 8 to 10 % was achieved. The limit of detection was 0.002 μg/mL for the lewisites and 0.005 μg/mL for arsenic trichloride (3:1 signal-to-noise ratio). The extraction method was validated with a proficiency test sample issued by the Organisation for the Prohibition of Chemical Weapons (OPCW). The rapidity and precision of the new method should help deter against the employment of lewisite as a chemical warfare agent: its use could be confirmed easily from analysis of aqueous samples. 相似文献
16.
A fast and simple gas chromatography-mass spectrometry (GC-MS) method for determination of forty-one pesticide residues in maize is introduced. The sample preparation involves liquid-liquid partitioning with acetonitrile in presence of anhydrous MgSO(4) and NaCl (QuEChERS) followed by dispersive liquid-liquid microextraction (DLLME) using carbon tetrachloride as extractive solvent and the extract obtained by QuEChERS as dispersive solvent. The main factors influencing DLLME efficiency including extractive solvent type and volume as well as the volume of dispersive solvent were evaluated in this study. The DLLME procedure effectively provides an enrichment of the extract and a cleanup of certain polar matrix components, which can maximize the sensitivity when a single quadrupole MS is used. For validation purposes, recoveries studies were carried out at two concentration levels, yielding recovery rates in the range 70-120% for 82% of the analytes. A good linearity and precision, with relative standard deviations generally below 20% were obtained for all forty-one pesticides. The limits of detection obtained were lower than 19 μg kg(-1) for more than 63% of the analytes. In two of a total of ten samples of maize, residues of lindane, tefluthrin, pirimicarb, folpet and bifenthrin were found, although at levels below the maximum limit established for this kind of samples. 相似文献
17.
建立了固相萃取-气相色谱-质谱法同时测定进口海产品中11种合成麝香(开司米木、萨利麝香、粉檀麝香、葵子麝香、特斯拉、佳乐麝香、二甲苯麝香、吐纳麝香、伞花麝香、西藏麝香和麝香酮)。样品经正己烷提取,弗罗里硅土固相萃取柱净化,内标法定量。目标物在0.001~0.1 mg/L内呈良好的线性相关,相关系数(r2)均大于0.990,方法检出限(信噪比(S/N)>3)为0.35~2.08μg/kg,定量限(S/N>10)为1.18~5.00μg/kg。分别在空白基质中添加低、中、高3个水平的标准品进行回收试验,平均回收率为83.1%~117%,相对标准偏差(RSD,n=6)为5.1%~8.5%。利用该方法对2017年上海口岸进口的30个海产品进行了筛查,发现佳乐麝香在93.3%的被测样品中均有检出,含量最高达3.82μg/kg。葵子麝香和伞花麝香也是检出较多的麝香品种,含量最高分别可达15.4μg/kg和10.5μg/kg。该方法特异性强,灵敏度高,适用于海产品中多种合成麝香残留物的筛查和确证。 相似文献
18.
单滴微萃取-气相色谱-质谱联用测定水中的硝基咪唑类药物 总被引:1,自引:0,他引:1
建立了单滴液相微萃取(SDME)与气相色谱-质谱(GC-MS)联用技术快速检测水中的硝基咪唑类药物,对影响萃取的因素(溶剂的种类及用量、萃取时间、萃取温度及搅拌子的搅拌速度)进行优化。优化的萃取条件为:溶剂为2.5μL正辛醇,温度为50℃,搅拌速度为600 r/min,时间为20 min。萃取后,微液滴转移至衍生化试管,于70℃水浴中衍生45 min,进样分析。该方法在水中的线性范围为0.5~400μg/L,线性相关系数良好(r0.998),检测限为0.16~0.57μg/L。加标自来水和湖水中的相对平均回收率为80.9%~103.6%,相对标准偏差为1.7%~9.0%。 相似文献
19.
A rapid, sensitive and environmentally friendly method for the analysis of 14 anilines in water samples by dispersive liquid–liquid
microextraction based on solidification of floating organic drop (DLLME-SFO) prior to gas chromatography–mass spectrometry
(GC-MS) was developed and optimized. In the proposed method, cyclohexane was used as the extraction solvent as its toxicity
was much lower than that of the solvent usually used in dispersive liquid–liquid microextraction (DLLME). In the optimized
conditions, the method exhibited good analytical performance. Based on a signal-to-noise ratio of 3, limits of detection for
anilines were in the range of 0.07 to 0.29 μg L−1, and the linear range was 0.5–200 μg L−1 with regression coefficients (r
2) higher than 0.9977. It was efficient for qualitative and quantitative analysis of anilines in water samples. The relative
standard deviations varied from 2.9 to 8.6 % depending on different compounds indicating good precision. Tap water and river
water were selected for evaluating the application to real water samples. The relative recoveries of anilines for the two
real samples spiked with 10 μg L−1 anilines were in the scope of 78.2–114.6 % and 77.3–115.6 %, respectively. 相似文献
20.
In the present work, a method was developed and optimized aiming at the determination of anatoxin-a in environmental water samples. The method is based on the direct derivatization of the analyte by adding hexylchloroformate in the alkalinized sample (pH = 9.0). The derivatized anatoxin-a was extracted by a solid-phase microextraction (SPME) procedure, submersing a PDMS fiber in an amber vial for 20 min under magnetic stirring. GC-MS was used to identify and quantify the analyte in the SIM mode. Norcocaine was used as internal standard. The following ions were chosen for SIM analyses (quantification ions in italics): anatoxin-a: 191, 164, 293 and norcocaine: 195, 136, 168. The calibration curve showed linearity in the range of 2.5-200 ng/mL and the LOD was 2 ng/mL. This method of SPME and GC-MS analysis can be readily utilized to monitor anatoxin-a for water quality control. 相似文献