首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A column high-performance liquid chromatography (HPLC) method was developed for the determination of glucosamine in dosage forms. Glucosamine was derivatized by addition of a solution containing orthophthaldialdehyde. The HPLC separation was achieved on a Spherimage 80 ODS2 column (250 x 4 mm id, 5 microm particle size) using an isocratic mobile phase containing phosphate buffer-methanol (90 + 10, v/v, pH 6.50) and methanol-tetrahydrofuran (97 + 3, v/v) in proportions of 85 + 15 at a flow rate of 1 mL/min, followed by fluorescence detection. The method was validated for specificity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The detector response for glucosamine HCI was linear over the concentration range of 0.1-20 microg/mL with a correlation coefficient of 0.9980. The accuracy was between 99.4 and 100.8%. The LOD and the LOQ were 0.009 and 0.027 microg/mL, respectively. The method was applied to determination of glucosamine in solid dosage forms.  相似文献   

2.
A simple, precise, and accurate isocratic RP-HPLC method was developed and validated for determination of eprosartan in bulk drug and tablets. Isocratic RP-HPLC separation was achieved on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using the mobile phase 0.5% formic acid-methanol-acetonitrile (80 + 25 + 20, v/v/v, pH 2.80) at a flow rate of 1.0 mL/min. The retention time of eprosartan was 7.64 +/- 0.05 min. The detection was performed at 232 nm. The method was validated for linearity, precision, accuracy, robustness, solution stability, and specificity. The method was linear in the concentration range of 10-400 microg/mL with a correlation coefficient of 0.9999. The repeatability for six samples was 0.253% RSD; the intraday and interday precision were 0.21-0.57 and 0.33-0.71% RSD, respectively. The accuracy (recovery) was found to be in the range of 99.86-100.92%. The drug was subjected to the stress conditions hydrolysis, oxidation, photolysis, and heat. Degradation products produced as a result of the stress conditions did not interfere with detection of eprosartan; therefore, the proposed method can be considered stability-indicating.  相似文献   

3.
A simple, precise, and accurate isocratic reversed-phase (RP) stability-indicating column high-performance liquid chromatographic (HPLC) assay method was developed and validated for determination of nebivolol in solid pharmaceutical dosage forms. Isocratic RP-HPLC separation was achieved on a Phenomenex Luna C8 (2) column (250 mm x 4.6 mm id, 5 microm particle size) using mobile phase composed of acetonitrile-pH 3.5 phosphate buffer (35 + 65, v/v) at a flow rate of 1.0 mL/min, and detection was performed at 280 nm using a photodiode array detector. The drug was subjected to oxidation, hydrolysis, photolysis, and heat to apply stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness, and solution stability. The method was linear in the drug concentration range of 40-160 microg/mL with a correlation coefficient of 0.9999. The repeatability relative standard deviation (RSD) for 6 samples was 0.69%, and the intermediate precision (RSD) for 6 samples was 1.39%. The accuracy (recovery) was between 98.57 and 99.55%. Degradation products produced as a result of stress studies did not interfere with detection of nebivolol, and the assay can thus be considered stability-indicating.  相似文献   

4.
A simple, rapid, and selective HPLC-diode array detector method was developed for the simultaneous determination of lidocaine hydrochloride (LD) and cetylpyridinium chloride (CPC) in two combined pharmaceutical formulations. Effective chromatographic separation was achieved on a Zorbax SB-C8 (4.6 x 250 mm, 5 microm particle size) column with gradient elution using a mobile phase composed of 0.05 M phosphoric acid and acetonitrile. The gradient elution started with 25% (v/v) acetonitrile, ramped up linearly to 85% in 5 min, and then was constant until the end of the run. The mobile phase was pumped at a flow rate of 1.2 mL/min. The multiple wavelength detector was set at 214 and 258 nm, and quantification of the analytes was based on measuring their peak areas. The retention times for LD and CPC were about 3.4 and 7.3 min, respectively. The reliability and analytical performance of the proposed HPLC procedure were statistically validated with respect to linearity, range, precision, accuracy, selectivity, robustness, LOD, and LOQ. Calibration curves were linear in the range of 5-200 and 10-400 microg/mL for LD and CPC, respectively, with correlation coefficients > 0.999. The proposed method was proven to be stability-indicating by the resolution of the two analytes from the related substance and potential impurity (2,6-dimethylaniline) as well as from forced-degradation products. The validated HPLC method was extended to the analysis of LD and CPC in two combined oral gel preparations for which the two analytes were successfully resolved from the pharmaceutical adjuvants and quantified with recoveries not less than 97.9%.  相似文献   

5.
An accurate, simple, reproducible, and sensitive HPLC method was developed and validated for the simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation. The analyses were performed on an RP C18 column, 150 x 4.60 mm id, 5 pm particle size. The mobile phase methanol-acetonitrile-water (76 + 13 + 11, v/v/v), was pumped at a constant flow rate of 1 mL/min. UV detection was performed at 253 nm. Retention times of atorvastatin calcium, ezetimibe, and fenofibrate were found to be 2.25, 3.68, and 6.41 min, respectively. The method was validated in terms of linearity, precision, accuracy, LOD, LOQ, and robustness. The response was linear in the range 2-10 microg/mL (r2 = 0.998) for atorvastatin calcium, 2-10 microg/mL (r2 = 0.998) for ezetimibe, and 40-120 microg/mL (r2 = 0.998) for fenofibrate. The developed method can be used for routine quality analysis of the drugs in the tablet formulation.  相似文献   

6.
An accurate, simple, reproducible, and sensitive liquid chromatographic method was developed and validated for the determination of omeprazole in powder for injection and in pellets. The analyses were performed at room temperature on a reversed-phase C18 column of 250 x 4.6 mm id, 5 microm particle size. The mobile phase, composed of methanol-water (90 + 10, v/v), was pumped at a constant flow rate of 1.5 mL/min. Detection was performed on a UV detector at 301 nm. The method was validated in terms of linearity, precision, accuracy, and ruggedness. The response was linear in the range 32-48 microg/mL (r2 = 0.9976). The relative standard deviation values for intra- and interday precision studies were 1.22 and 1.56% for injectable and 2.13 and 2.45% for pellets, respectively. Recoveries ranged between 95.81 and 100.48%.  相似文献   

7.
A commercially available porous silica rod column was used as a separation tool for the sequential injection analysis (SIA). A porous solid monolithic column showed high performance at a low pressure, allowing sequential injection analysis to be used for the first time for separation in HPLC fashion. In this contribution, we tried to demonstrate a new separation concept with SIA manifold for the simultaneous determination of four different compounds (methylparaben (MP), propylparaben (PP), triamcinolone acetonide (TCA) and internal standard ketoprofen (KP)) in a pharmaceutical triamcinolon cream 0.1% formulation. A Chromolith Flash RP-18e, 25 mm x 4.6 mm column with a 10 mm pre-column (Merck, Germany) and a FIAlab 3000 system (USA) with an 8-port selection valve and 10 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-methanol-water (35:5:65, v/v/v) + 0.05% nonylamine, pH 2.5, flow rate 0.6 ml min(-1). The analysis time was <6 min. A novel sequential injection chromatography (SIC) technique with UV spectrophotometric detection was optimised and validated.  相似文献   

8.
A new high-performance liquid chromatography (HPLC) method was developed for the quality control of pancuronium bromide and its degradation products. The HPLC method used a 5-microm Supelcogel ODP-50 (150x4 cm) column with acetonitrile-CH3OH-water-F3CCOOH (20.5:74.9:0.1, v/v) as the mobile phase (pH value 2.0 adjusted with trifluoroacetic acid) at a flow-rate 0.8 ml/min and UV detection at 210 nm. The Beer's law plots were found to be linear over the concentration range 0.4-1.2 mg/ml of pancuronium bromide and 0.04-0.08 mg/ml of desacetyl degradation products (R2=0.9995). The RSD of the peak areas was 1.09% and the recovery was 102.43%. The RSD value shows good precision, acceptable accuracy and reproducibility of the new method for the determination of pancuronium bromide in presence of its desacetyl degradation products. The method is rapid and sensitive enough to be used for Pavulon injection analysis.  相似文献   

9.
A rapid, sensitive and specific high-performance liquid chromatography-electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the first time to determine the concentration of lafutidine in human plasma. After the addition of diazepam (the internal standard, IS) and 1 M sodium hydroxide solution to 0.5-ml plasma sample, lafutidine was extracted from plasma with n-hexane : isopropanol (95 : 5, v/v). The organic layer was evaporated and the residue was redissolved in 200-microl mobile phase. The analyte was chromatographically separated on a prepacked Shimadzu Shim-pack VP-ODS C(18) column (250 x 2.0 mm i.d.) using a mixture of methanol-water (20 mM CH(3)COONH(4)) = 80 : 20 (v/v) as mobile phase. Detection was performed on a single quadrupole mass spectrometer using an electrospray ionization interface and the selected-ion monitoring (SIM) mode. The method showed excellent linearity (r = 0.9993) over the concentration range of 5-400 ng/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation. The limit of detection was 1 ng/ml. The validated LC/ESI-MS method has been successfully applied to the bioequivalence study of lafutidine in 24 healthy male Chinese volunteers.  相似文献   

10.
A new high-performance liquid chromatographic method was developed and validated for clopidogrel determination in pharmaceutical formulations. The system consisted of an ACE 5 octadecylsilane (C18; 150 x 4.6 mm id), 5.0 microm particle size column; methanol-0.1% triethylamine (75 + 25, v/v), pH 5.3, mobile phase at a flow rate of 1.2 mL/min; and a diode array detector set at 220 nm. Specificity, linearity, precision, accuracy, and robustness were the parameters evaluated. The retention time for clopidogrel was 6.8 min. To estimate specificity, an aqueous sample solution was subjected to degradation by ultraviolet light and by acid, alkaline, and oxidation media. The peaks of degradation products did not interfere with the compound signal, and there was no interference when a placebo solution was analyzed. Linearity over a concentration range of 10.0 to 90.0 microg/mL was shown (correlation coefficient = 0.9998). Low values of relative standard deviation indicated the adequate intraday and interday precision. The average recovery was found as 99.16%. In the robustness test, small modifications to the mobile phase composition did not affect the determination of clopidogrel. The proposed method proved to be simple, fast, and cost efficient for the intended use.  相似文献   

11.
Reversed-phase liquid chromatography (LC) and LC/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of etoricoxib in pharmaceutical dosage forms. The LC method was performed by reversed-phase chromatography on a Synergi fusion C18 column (150 x 4.6 mm id) maintained at ambient temperature. The mobile phase consisted of 0.01 M phosphoric acid, pH 3.0-acetonitrile (62 + 38, v/v) at a flow rate of 1.0 mL/min, and photodiode array detection at 234 nm was used. The chromatographic separation was obtained within 7.0 min, and calibration curves were linear in the concentration range of 0.02-150 microg/mL. The LC/MS/MS method was performed on a Luna C18 column (50 x 3.0 mm id). The mobile phase consisted of acetonitrile-water (95 + 5)-0.1% acetic acid (90 + 10, v/v). Detection was performed by positive electrospray ionization in the multiple reaction monitoring mode, monitoring the transitions 359.3 > 280.0 and 332.0 > 95.0 for etoricoxib and piroxicam (internal standard), respectively. The chromatographic separation was obtained within 2.0 min, and calibration curves were linear in the concentration range of 1-5000 ng/mL. Validation parameters, such as specificity, linearity, precision, accuracy, and robustness, were evaluated, which gave results within the acceptable range for both methods. Moreover, the proposed methods were successfully applied for routine quality control analysis of pharmaceutical products and showed significant correlation (r = 0.9999) of the results.  相似文献   

12.
A new method was developed and fully validated for the quantitation of benazepril, benazeprilat and hydrochlorothiazide in human plasma. Sample pretreatment was achieved by solid-phase extraction (SPE) using Oasis HLB cartridges. The extracts were analysed by high-performance liquid chromatography (HPLC) coupled to a single-quadrupole mass spectrometer (MS) with an electrospray ionization interface. The MS system was operated in selected ion monitoring (SIM) modes. HPLC was performed isocratically on a reversed-phase porous graphitized carbon (PGC) analytical column (2.1 x 125.0 mm i.d., particle size 5 microm). The mobile phase consisted of 55% acetonitrile in water containing 0.3% v/v formic acid and pumped at a flow rate of 0.15 ml min(-1). Chlorthalidone was used as the internal standard (IS) for quantitation. The assay was linear over a concentration range of 5.0-500 ng ml(-1) for all the compounds analysed, with a limit of quantitation of 5 ng ml(-1) for all the compounds. Quality control (QC) samples (5, 10, 100 and 500 ng ml(-1)) in five replicates from three different runs of analyses demonstrated intra-assay precision (coefficient of variation (CV) < or =14.6%), inter-assay precision (CV < or = 5.6%) and overall accuracy (relative error less than -8.0%). The method can be used to quantify benazepril, benazeprilat and hydrochlorothiazide in human plasma, covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

13.
A rapid and effective isocratic chromatographic procedure is successfully developed to determinate methotrexate (MTX) entrapment efficiency (EE) in polymeric nanocapsules using reversed-phase high-performance liquid chromatography. The method employed a RP-C(18) Shimadzu Shim-pack CLC-ODS (150 mm x 4.6 mm, 5 microm) column with mobile phase constituted by a mixture of water-acetonitrile-tetrahydrofuran (65:30:5 v/v/v; pH 3.0) at a flow rate of 0.8 mL/min. The eluate is monitored with a UV detector set at 313 nm. The parameters used in the validation process are: linearity, specificity, precision, accuracy, and limit of quantitation (LOQ). The linearity is evaluated by a calibration curve in the concentration range of 10-50 microg/mL and presented a correlation coefficient of 0.9998. The polymers (PLA or PLA-PEG), oil, and surfactants used in the nanocapsule formulation did not interfere with analysis and the recovery was quantitative. The intra and inter-day assay relative standard deviation were less than 0.72%. Results are satisfactory, and the method proved to be adequate for the determination of methotrexate in nanocapsules formulations.  相似文献   

14.
A specific and sensitive analytical method for the determination of sparfloxacin in serum and urine is described. Serum proteins are removed by precipitation with acetonitrile after the addition of ofloxacin as an internal standard. The supernatant solvent is evaporated in a vacuum concentrator and the dry residue is redissolved in the mobile phase. Separation is performed on a cation-exchange column (Nucleosil 100 5SA, 125 x 4.0 mm I.D., 5 microns particle size) protected by a guard column (Perisorb RP-18, 30 x 4.0 mm I.D., 30-40 microns particle diameter). The mobile phase consisted of 750 ml of acetonitrile and 250 ml of 100 mmol/l phosphoric acid (v/v) to which sodium hydroxide had been added. The final concentration of sodium was 23 mmol/l and the pH was 3.82. Sparfloxacin and ofloxacin were determined by spectrofluorimetry (excitation wavelength 295 nm; emission wavelength 525 nm). The flow-rate was 1.5 ml/min and the retention times were 4.7 (sparfloxacin) and 8.0 (ofloxacin) min. Validation of the method yielded the following results for serum: detection limit 0.05 mg/l; precision between series 10.4-3.6%; recovery 99.5-100.0%; comparison with a microbiological assay c(bioassay) = 1.035c(HPLC) - 0.06. The test organism was Bacillus subtilis ATCC 6633. For urine the results were: detection limit 0.5 mg/l; precision between series 7.8-5.0%; recovery 97.0-97.8%; method comparison c(bioassay) = 1.092c(HPLC) - 1.09. No interferences were observed in human volunteers. The method can also be applied to stool samples.  相似文献   

15.
A reversed-phase high-performance liquid chromatographic method with detection at 220 nm was developed and validated for the determination of ethyl-3-(N-n-butyl-N-acetyl)aminopropionate, IR 3535, in an insect repellent semi-solid product. A Hypersil ODS RP-C18 column (250 x 4.6 mm), 5 microm particle size, was equilibrated with a mobile phase consisted of water-acetonitrile (60:40, v/v). Its flow-rate was 1.0 ml/min. Excipients did not interfere with the determination of IR 3535 (Rs = 8.663). Intra- and inter-day relative standard deviations for samples were not higher than 0.61 and 1.2%, respectively. Mean recovery was found not lower than 98.5% and not higher than 100.3%. The method of external standard was adopted. Calibration curves were linear in the concentration range between 1.0 x 10(-6) and 5.0 x 10(-4) M. Limits of detection and quantitation were 65 and 196 ng/ml, respectively.  相似文献   

16.
A new and accurate HPLC method using sulfobutylether-beta-cyclodextrin (SBE-beta-CD) as chiral mobile phase additive (CMPA) was developed and validated for the determination of R-(+)pantoprazole in S-(-)pantoprazole. The influences of type and concentration of CD, ACN content and buffer pH of mobile phase on the resolution and retention of enantiomers were investigated. A baseline resolution of pantoprazole enantiomers was achieved on a Spherigel C18 column (150 mm x 4.6 mm, 5 microm) using ACN and 10 mM phosphate buffer (pH 2.5) containing 10 mM SBE-beta-CD (15:85 v/v) as mobile phase with a flow rate of 0.9 mL/min at 20 degrees C. The detection wavelength was set at 290 nm. The method was extensively validated in terms of accuracy, precision and linearity according to the International Conference on Harmonisation (ICH) guidelines and proved to be robust. The LOD and LOQ for R-(+)pantoprazole were 0.2 and 0.5 microg/mL, respectively, with 5 microL injection volume. A good linear relationship was obtained in the concentration range of 0.5-6.0 microg/mL with r(2) >0.999 for R-(+)pantoprazole. The percentage recovery of the R-(+)pantoprazole ranged from 92.1 to 101.2 in bulk drug of S-(-)pantoprazole. The method is capable of determining a minimum limit of 0.05% w/w of R-enantiomer in S-(-)pantoprazole bulk samples.  相似文献   

17.
A reversed-phase liquid chromatographic (LC) method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical dosage forms. The LC method was carried out on a Synergi fusion C18 column (150 mm x 4.6 mm id) maintained at 45 degrees C. The mobile phase consisted of phosphate buffer 0.03 M, pH 4.5-acetonitrile (35 + 65, v/v) run at a flow rate of 0.6 mL/min, and detection was made using a photodiode array detector at 234 nm. The chromatographic separation was obtained within 15.0 min, and calibration graphs were linear in the concentration range of 0.5-200 microg/mL. Validation parameters such as specificity, linearity, precision, accuracy, and robustness were evaluated, giving results within the acceptable range for both compounds. Moreover, the proposed method was successfully applied for the routine quality control analysis of pharmaceutical products.  相似文献   

18.
An isocratic HPLC method with detection at 248 nm was developed and fully validated for the determination of tigecycline in rabbit plasma. Minocycline was used as an internal standard. A Hypersil BDS RP-C18 column (250 x 4.6 mm, 5 microm particle size) was used with the mobile phase phosphate buffer (pH 7.10, 0.070 M)-acetonitrile (76 + 24, v/v) at a flow rate of 1.0 mL/min. The elution time of tigecycline and minocycline was approximately 8.1 and 9.9 min, respectively. Calibration curves of tigecycline were linear in the concentration range of 0.021-3.15 microg/mL in plasma. The LOD and LOQ in plasma were estimated as 7 and 21 ng/mL, respectively. The intraday and interday precision values of the method were in the range of 5.0-7.1 and 5.6-9.1%, while the corresponding accuracy values were in the ranges of 92.8-111.1 and 97.6-102.3%, respectively. At the LOQ, the intraday precision was 18.7%, while intraday and interday accuracy values were 97.3 and 98.0%, respectively. Robustness of the proposed method was studied using a Plackett-Burman experimental design. A pharmacokinetic profile is presented for confirmation of the applicability of the method to pharmacokinetic studies.  相似文献   

19.
An HPLC method was developed and validated for the determination of butamyrate citrate. The HPLC separation was achieved on a diol column (300 × 4.6 mm) packed with 5.0 μm particle size using a mobile phase of ammonium acetate buffer (pH = 6.5) and methanol (750:250, v/v) at a flow rate of 1.4 ml min?1. The UV detector was operated at 225 nm. The method was validated for specificity, linearity, precision, accuracy and robustness. The retention time was 5.9 min. The proposed method provided linear responses within the concentration range 75–225 μg ml?1 with LOD and LOQ values of 0.69 and 2.29 μg ml?1, respectively. Correlation coefficient (r) of the regression equation was 0.9999. The method was found to be precise, accurate, and reproducible.  相似文献   

20.
A new procedure based on hydrophilic interaction chromatography coupled to tandem mass spectrometry (ionisation process by pneumatically assisted electrospray in negative ion mode), is developed and validated for the simultaneous determination of underivatised taurine and methionine in beverages rich in carbohydrates such as energy drinks. No initial clean-up procedure and no sample derivatisation are required. Satisfactory analysis was obtained on an Astec apHera NH2 (150 mm x 4.6 mm; 5 microm) column with methanol-water (60/40) as mobile phase. The method was validated in terms of specificity, detection limits, linearity, accuracy, precision and stability, using threonine as internal standard. The potential effects of matrix and endogenous amino acid content were also examined. The limits of detection in the beverage varied from 20 microg L(-1) for taurine to 50 micro L(-1) for methionine.  相似文献   