首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid, sensitive and specific assay method has been developed to simultaneously determine human plasma concentrations of hydrocodone and its metabolites, norhydrocodone, hydromorphone, using high-performance liquid chromatography with an electrospray ionization (ESI) tandem mass spectrometry (HPLC?CMS?CMS). Hydrocodone, its metabolites, and internal standard, hydrocodone-d 3, norhydrocodone-d 3, hydromorphone-d 3, were separated from human plasma using solid-phase extraction (Empore MPC-SD Solid Phase Extraction Disk). The eluate was dried, reconstituted and injected into the LC?CMS?CMS system. Chromatographic separation was performed on a Kromasil 100-5SIL-Dimensions C18 column (100 × 2.1 mm, 5.0 ??m, Thermo Hypersil-Keystone, USA) using a gradient mobile phase with 20 mmol L?1 ammonium formate in water with 0.2% formic acid and 0.1% formic acid in acetonitrile. Detection and quantitation were performed by MS/MS using electrospray ionization and multiple reactions monitoring in the positive ion mode. The calibration curves were linear over the concentration ranges 0.05?C50 ng mL?1 for hydrocodone (r 2 = 0.9991) and norhydrocodone (r 2 = 0.9990), and 0.01?C10 ng mL?1 for hydromorphone (r 2 = 0.9990). The limit of quantification was 0.05 ng mL?1 for hydrocodone and norhydrocodone, and 0.01 ng mL?1 for hydromorphone. The extraction recovery was above 64.36, 68.51 and 71.78% for hydrocodone, norhydrocodone and hydromorphone. The accuracy was higher than 99.06, 97.70 and 100.07% for hydrocodone, norhydrocodone and hydromorphone. The intra- and inter-day precisions were <5.80, 5.90 and 3.02% for hydrocodone, norhydrocodone and hydromorphone. The method was accurate, sensitive and simple and was successfully applied to a pharmacokinetic study after a single oral administration of hydrocodone bitartrate at a dose of 5 mg in 12 healthy Chinese volunteers.  相似文献   

2.
A selective, rapid and sensitive liquid chromatography tandem mass spectrometry method has been developed for the simultaneous determination of ramipril and ramiprilat in human plasma using enalapril as the internal standard via one-step extraction with ethyl acetate under acidic condition. The analysis was carried out on a Diamonsil C18 column (150 mm × 4.6 mm i.d., 5 μm) with a mobile phase consisting of 1% formic acid-acetonitrile (25:75, v/v) at a constant flow rate of 0.5 mL min?1. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring mode via electrospray ionization. Linear calibration curves of ramipril and ramiprilat were obtained in the concentration range of 0.107–107.0 and 0.262–105.0 ng mL?1, respectively. The intra- and inter-day precision (RSD) values were below 8.2 and 4.8% for ramipril, 10.4 and 12.3% for ramiprilat, and accuracy (RE) were within ±5.5 and ±3.2%, respectively at all QC levels. The method was utilized to support clinical pharmacokinetic studies in healthy volunteers following oral administration of ramipril tablets.  相似文献   

3.
A rapid, sensitive and accurate ultra-performance liquid chromatography/tandem mass spectrometry method was developed and validated for the quantitative determination of imidol in rat plasma for the first time. The analyte and internal standard were extracted from plasma by liquid?Cliquid extraction with diethyl ether. The separation was performed on a BEH C18 column (50 mm × 2.1 mm, 1.7 ??m). The detection was carried out by electrospray ionization mass spectrometry in positive ion mode with multiple reaction monitoring. Linear calibration curves were obtained in the concentration range of 2.5?C2,500 ng mL?1, with the lower limit of quantification of 2.5 ng mL?1. The intra- and inter-day precision (RSD) values were below 8% and accuracy (RE) was from ?7.9 to 6.3%. After strict validation, the method was applied successfully to the pharmacokinetic study of imidol in rats after oral and intravenous administration, respectively.  相似文献   

4.
This paper presents an analytical method for the simultaneous determination of zoalene and its metabolite 3-amino-5-nitro-o-toluamide (3-ANOT) in chicken muscle and liver by solid phase extraction and UPLC?CMS-MS operated in the positive and negative ionization switching mode. Samples were extracted with phosphate buffer solution and purified with OASIS? HLB cartridge after pH adjustment. The determination was carried out using UPLC?CMS-MS on a Waters Acquity BEH C18 column with 0.1% formic acid in water/acetonitrile as mobile phase with gradient elution. The linearity of the analytical response across the studied range of concentrations (2.0?C1,000 ??g L?1) was excellent, obtaining correlation coefficients higher than 0.999. Matrix effects had been investigated for zoalene and 3-ANOT. Recovery studies were carried out on spiked chicken muscle and liver blank samples, at four concentration levels (50, 1,500, 3,000, and 4,500 ??g kg?1 for chicken muscle and 50, 3,000, 6,000, and 9,000 ??g kg?1 for chicken liver) performing six replicates at each level. Mean recoveries of 77.9?C94.2% with CVs of 3.2?C8.7% were obtained. The method demonstrated to be suitable for the simultaneous determination of zoalene and 3-ANOT in chicken tissues.  相似文献   

5.
A reversed-phase liquid chromatography coupled to tandem mass spectrometry (LC?CMS?CMS) method was developed and validated for the determination of fulvestrant in rat plasma. Sample preparation involved a liquid-liquid extraction using 1.0 mL of n-hexane?Cisopropanol (90:10, v/v) to extract the analyte from 0.1 mL of rat plasma. The analytes were separated on a phenyl-based column using the mobile phase consisting of methanol/water containing 5 mM ammonium acetate at the flow rate of 0.3 mL min?1. The analytes were monitored by tandem mass spectrometry under electrospray negative ionization mode. Linear calibration curves were generated over the fulvestrant concentration ranges of 0.05?C10.0 ng mL?1 in rat plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical methods (<15%). This developed and validated assay method was successfully employed to characterize the plasma concentration-time profile of fulvestrant after its intramuscular administration in rats at a dose of 10 mg kg?1.  相似文献   

6.
A fast, sensitive, and specific LC?CMS?CMS method for determination of quinine (QN) and doxycycline (DOX) in rat plasma has been developed and validated. QN, DOX, and cimetidine (internal standard, IS) were extracted from the plasma by protein precipitation. The compounds were separated on a C18 column with methanol?C0.1% aqueous formic acid 70:30 (v/v) as mobile phase at a flow rate of 0.5 mL min?1 (split 1:3). Detection was by positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode, monitoring the transitions 325.0 ?? 307.0, 445.0 ?? 428.1, and 252.8 ?? 159.0, for QN, DOX, and IS, respectively. The analysis was carried out in 2.0 min and the method was linear in the plasma concentration range 5?C5,000 ng mL?1. The mean extraction recoveries for QN, DOX, and IS from plasma were 89.4, 90.5, and 86.3%, respectively. The method was validated for linearity, precision, accuracy, specificity, and stability; the results obtained were within the acceptable range. The proposed method was successfully applied to the determination of QN and DOX in rat plasma samples to support pharmacokinetic studies.  相似文献   

7.
A sensitive and selective liquid chromatography?Ctandem mass spectrometry method for the determination of pethidine and atropine in rabbit plasma was developed and validated. The analytes and internal standard (IS) are extracted from plasma by liquid?Cliquid extraction using ethyl acetate, and separated on a Zorbax SB-Aq column (2.1 × 150 mm, 3.5 ??m) using acetonitrile?C0.1% formic acid as mobile phase with gradient elution. Electrospray ionization source was applied and operated in positive ion mode, and multiple reaction monitoring mode was used for quantification using target fragment ions m/z 247.8 ?? 219.7 for pethidine, m/z 289.9 ?? 123.8 for atropine and m/z 295.0 ?? 266.8 for IS, respectively. The assay is linear over the range of 5?C1,000 ng mL?1 for pethidine and atropine, with a lower limit of quantification of 3 ng mL?1 for pethidine and 5 ng mL?1 for atropine. Intra-day and inter-day precision are less than 11% and the accuracy are in the range of 90.4?C106.3%. Furthermore, the newly developed method is successfully used for the determination of pethidine and atropine in rabbit plasma for pharmacokinetic study.  相似文献   

8.
A rapid, sensitive and reliable LC?CMS?CMS method for the determination of eight benzimidazoles in animal feed was developed and validated. Samples were extracted with acidic acetonitrile. The extract was diluted with 0.1% formic acid in water, and analyzed by LC?CMS?CMS on a Waters XBridge? C18 column with acetonitrile/0.1% formic acid in water as mobile phase. The samples were quantified with the matrix standard calibration curve method. Good linearity was obtained for eight benzimidazoles at a concentration of 0.005?C2.5 ??g mL?1 with a linear relative coefficient more than 0.990. Recoveries of 84.0?C104.0% with CVs of 2.50?C7.50% were obtained. Limit of detection was 2.1?C63.0 ??g kg?1. The method demonstrated to be suitable for the determination of eight benzimidazoles in animal feed samples.  相似文献   

9.
A sensitive and specific liquid chromatography?Celectrospray ionization?Ctandem mass spectrometry method has been developed and validated for the identification and quantification of brivudine in human plasma using diclofenac as an internal standard. The method involves extraction with ethyl acetate. The analyte was separated on a C18 column and analyzed in multiple reaction monitoring mode with a negative electrospray ionization interface using the [M?CH]? ions, m/z 332.8??m/z 80.9 for brivudine, m/z 293.6??m/z 249.5 for diclofenac. The method was validated over the concentration range of 5.54?C2,836 ??g L?1 for brivudine. The intra-and inter-day precisions were less than 8.91% in terms of relative standard deviation (RSD), and the accuracy was within ?4.22% in terms of relative error (RE). The lower limit of quantification (LLOQ) was 5.54 ??g L?1 with acceptable precision and accuracy. There were almost no matrix effects. Recovery of brivudine spiked in drug-free plasma was higher than 77.17%. The method was used to study the pharmacokinetic profile of brivudine in human plasma after oral administration of brivudine tablets.  相似文献   

10.
A sensitive and rapid LC–MS–MS method was developed for the simultaneous determination of ebastine and carebastine in human plasma. Solid-phase extraction was used to isolate the compounds from the biological matrix followed by separation on a Symmetry C18 column under isocratic conditions. The mobile phase was 10 mM ammonium formate in water/acetonitrile (40:60, v/v). Detection was carried out using a triple-quadrupole mass spectrometer in positive electrospray ionization and multiple reaction monitoring mode. The method was fully validated over the concentration range of 0.1–10 ng mL?1 for ebastine and 0.2–200 ng mL?1 for carebastine in human plasma, respectively. The lower limit of quantification (LLOQ) was 0.1 ng mL?1 for ebastine and 0.2 ng mL?1 for carebastine. For ebastine and carebastine inter- and intra-day precision (CV%) and accuracy values were all within ±15% and 85–115%, respectively. The extraction recovery was on average 60.0% for ebastine and 60.3% for carebastine.  相似文献   

11.
Wu  Yin-Liang  Xu  Yong  Yang  Ting  Huang-Fu  Wei-Guo 《Chromatographia》2011,74(11):833-838

This paper presents an analytical method for the simultaneous determination of zoalene and its metabolite 3-amino-5-nitro-o-toluamide (3-ANOT) in chicken muscle and liver by solid phase extraction and UPLC–MS-MS operated in the positive and negative ionization switching mode. Samples were extracted with phosphate buffer solution and purified with OASIS HLB cartridge after pH adjustment. The determination was carried out using UPLC–MS-MS on a Waters Acquity BEH C18 column with 0.1% formic acid in water/acetonitrile as mobile phase with gradient elution. The linearity of the analytical response across the studied range of concentrations (2.0–1,000 μg L−1) was excellent, obtaining correlation coefficients higher than 0.999. Matrix effects had been investigated for zoalene and 3-ANOT. Recovery studies were carried out on spiked chicken muscle and liver blank samples, at four concentration levels (50, 1,500, 3,000, and 4,500 μg kg−1 for chicken muscle and 50, 3,000, 6,000, and 9,000 μg kg−1 for chicken liver) performing six replicates at each level. Mean recoveries of 77.9–94.2% with CVs of 3.2–8.7% were obtained. The method demonstrated to be suitable for the simultaneous determination of zoalene and 3-ANOT in chicken tissues.

  相似文献   

12.
A sensitive, specific and rapid high performance liquid chromatography?Catmospheric pressure chemical ionization source-tandem mass spectrometry (LC-APCI-MS-MS) method for the determination of pilocarpine in human plasma was developed and validated. The method is based on liquid?Cliquid extraction, followed by a reversed-phase liquid chromatographic separation, and detected by means of tandem mass spectrometry. The linear calibration curve covered a concentration range of 2?C500 ??g L?1. The intra- and inter-day precisions for pilocarpine were <10% and the accuracies were between 90 and 110%. The method was applied successfully to a pharmacokinetic study involving 20 healthy Chinese male volunteers after oral administration of 6 mg pilocarpine.  相似文献   

13.
A novel, simple and reliable bioanalytical method of high performance liquid chromatography for simultaneous quantification of nelarabine and its active metabolite 9-β-d-arabinofuranosyl-guanine (Ara-G) in human plasma was developed and validated. The calibration curves for nelarabine and Ara-G were linear over concentration ranges of 0.1562–10 and 0.6250–40 μg mL?1, respectively. Intra- and inter-day precision and accuracy results satisfied the acceptable criteria for bioanalytical method validation. This method has been applied to a pharmacokinetic study involving 20 T-cell lymphoblastic leukemia/lymphoma patients.  相似文献   

14.
Combination drug products containing amlodipine and atorvastatin are widely marketed and used in the treatment of concomitant hypertension and dyslipidemia. A rapid, simple and sensitive high performance liquid chromatography?Ctandem mass spectrometry (HPLC?CMS?CMS) method for determination of atorvastatin and amlodipine in plasma of hypertensive patients has been developed and validated to be used for therapeutic drug monitoring. The plasma samples were subjected to methanol protein precipitation. Chromatographic separation was performed on a C18 column using a gradient elution. The mobile phase consisted of 0.1% of formic acid in water and 0.1% of formic acid in acetonitrile and was pumped at a flow rate of 0.4 mL min?1. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode. The calibration curves were linear over the range of 0.46?C1,000 ng mL?1. The intra- and inter-day precisions were within 12.2%, while the accuracy ranged from 92.7 to 108.1%. The validated LC?CMS?CMS method was successfully applied for the determination of atorvastatin and amlodipine in plasma of hypertensive patients.  相似文献   

15.
Ten highly potent estrogens including estrone (E1), 17β-estradiol (E2), estriol (E3), 4-hydroxyestrone (4-OHE1), 2-hydroxyestradiol (2-OHE2), 16α-hydroxyestrone (16α-OHE1), 2-methoxyestrone (2-MeO-E1), 2-methoxyestradiol (2-MeO-E2), diethylstilbestrol (DES), 17α-ethynylestradiol (EE2) were identified and quantified by solid-phase extraction followed by liquid chromatography–mass spectrometry. An improved two-step SPE process was employed in this work. C18 cartridge was used for both enrichment of all target estrogens and retention of some nonpolar impurities, and then a polar florisil cartridge was subsequently used to separate the interested estrogens from the polar impurities. After this pretreatment for water samples, the results showed clean chromatograms without interference from matrix effects. Besides, this method was accurate (recovery percentages between 70.4 and 106.8% for river water and 73.4 and 101.3% for raw sewage, except 4-OHE1 and 2-OHE2), and precise (RSD varying between 1.3 and 17.8% for river water and 3.4 and 16.7% for raw sewage). In the optimized condition, this method was used to verify the presence of the target analytes in the Qinghe River and influent of sewage treatment plant in the northwest of Beijing, China. Some estrogens were detected in the river water and sewage water samples at a relatively high concentration. The developed method proved to be effective for analyzing estrogen compounds in complex matrices. Moreover, the achieved results demonstrated that a great concern should be addressed to the potential risk of the presence of estrogens in the aquatic environment.  相似文献   

16.
A sensitive, specific, and rapid liquid chromatography?Celectrospray ionization?Ctandem mass spectrometry (LC?CESI?CMS?CMS) method was developed for determination of revaprazan in human plasma. Plasma samples were simply treated with methanol to precipitate, and then isolated supernatants were directly injected into the LC?CESI?CMS?CMS system. A Thermo Hypurity C18 column (150 × 2.1 mm, 5 ??m) with mobile phase of methanol?Cwater (70:30, v/v) containing 0.05% formic acid was used for chromatographic separation. Mass-spectrometric quantification was carried out in multiple reaction monitoring (MRM) mode, monitoring the m/z transitions 363.1 ?? 245.1 for revaprazan and 531.2 ?? 489.2 for ketoconazole (internal standard, IS) in positive ion mode. The linear calibration curves covered a concentration range of 2?C1,000 ??g L?1. The intra- and interday precisions (percentage relative standard deviation, RSD%) for revaprazan at three quality control levels were all <5%, and the accuracies were between 90% and 110%. The method has been successfully applied to a pharmacokinetic study involving 12 Chinese volunteers, and the main pharmacokinetic parameters of revaprazan in Chinese population are reported for the first time.  相似文献   

17.
A selective, sensitive and high throughput LC–MS–MS method has been developed and validated for the chromatographic separation and quantitation of tolterodine (TOL) and its metabolite 5-hydroxymethyl TOL in human plasma. Sample clean-up concerned liquid–liquid extraction of the drug, metabolite and their respective labelled internal standards from 300 μL human plasma. Both the analytes were chromatographically separated on a Symmetry C18 (100 mm × 4.6 mm, 5 μm particle size) analytical column using 10 mM ammonium formate (pH 5.0 ± 0.1, adjusted with formic acid) and acetonitrile (35:65, v/v) as the mobile phase with a resolution factor of 2.72. The method was validated over the concentration range of 0.025–10.0 ng mL?1 for both analytes. The process efficiency found for TOL and its metabolite was 98.3 and 99.5%, respectively. The method was successfully applied to a pivotal bioequivalence study in 41 healthy human subjects after oral administration of a 2 mg tablet formulation under fasting conditions.  相似文献   

18.
We developed a rapid and sensitive method for determining efavirenz, 8-hydroxyefavirenz, and 8,14-dihydroxyefavirenz in human plasma simultaneously using liquid chromatography?Ctandem mass spectrometry (LC?CMS?CMS). Three compounds and ritonavir, an internal standard, were extracted from plasma using ethyl acetate in the presence of 0.1 M sodium carbonate after incubation of ??-glucuronidase (500 U). After drying the organic layer, the residue was reconstituted in mobile phase (acetonitrile:20 mM ammonium acetate, 90:10, v/v) and injected onto a reversed-phase C18 column. The isocratic mobile phase was eluted at 0.2 mL min?1. The ion transitions monitored in multiple reaction-monitoring mode were m/z 314 ?? 244, 330 ?? 258, 346 ?? 262, and 721 ?? 296 for efavirenz, 8-hydroxyefavirenz, 8,14-dihydroxyefavirenz, and ritonavir, respectively. The retention time is 1.93, 1.70, 1.52, and 1.82 min for efavirenz, 8-hydroxyefavirenz, 8,14-dihydroxyefavirenz, and ritonavir, respectively. The coefficients of variation of the assay precision were less than 10.7%, and the accuracy was 90?C111%. The lower limits of quantification (LLOQ) were 5 ng mL?1 for efavirenz and 8-hydroxyefavirenz. This method was used to measure the plasma concentrations of efavirenz and its metabolites from healthy volunteers after a single 600 mg oral dose of efavirenz. This analytical method is a very rapid, sensitive, and accurate to determine the pharmacokinetic profiles of efavirenz including its metabolites.  相似文献   

19.
An alternative rapid and sensitive liquid chromatography–tandem mass spectrometry method has been developed and validated for simultaneous analysis of proguanil (PRO) and cycloguanil (CYC) in human plasma. The analytes were extracted from human plasma by solid phase extraction. Riluzole (RIL) was used as an internal standard for proguanil and cycloguanil. A HyPURITY Advance C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The method involves simple isocratic chromatography conditions and mass spectrometric detection in the positive ionization mode using an API-4000 system. The proposed method has been validated with linear range of 1.5–150.0 ng mL?1 for PRO and 0.5–50.0 ng mL?1 for CYC. The inter-run and intra-run precision values are within 2.54, 9.19% for PRO and 1.99, 10.69% for CYC at LOQ levels. The overall recoveries for PRO and CYC were 102.52 and 106.72%, respectively. Total elution time was as low as 2.50 min. This validated method was used successfully for analysis of plasma samples from a bioequivalence study.  相似文献   

20.
Fang Gao  Li Ding  Pengcheng Ma  Fei Wu 《Chromatographia》2010,71(11-12):1007-1014
Zofenoprilat is an active metabolite of zofenopril, which is very unstable in plasma because of oxidative degradation of its thiol group. In this method, p-bromophenacyl bromide was used as derivatization reagent, immediately after plasma separation, to react with the free thiol group of zofenoprilat and form the derivative zofenoprilat-p-BPB. After acidification with 50% acetic acid, the derivatized plasma samples were extracted with methyl tert-butyl ether and separated on a C18 column with 40:60 (v/v) 10 mM ammonium acetate buffer solution containing 0.1% formic acid–acetonitrile as mobile phase. Calibration plots were linear over the concentration range 1–500 ng mL?1 for zofenopril and 2–1,800 ng mL?1 for zofenoprilat. The method was successfully used to study the bioavailability of zofenopril calcium capsules relative to that of zofenopril calcium tablets in healthy Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号