首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 17 毫秒
1.
Lee SK  Park SG  Moon JH  Yang SM 《Lab on a chip》2008,8(3):388-391
Holographic lithography in combination with photo-lithography provides a novel optofluidic platform through incorporation of periodic photonic units inside the microfluidic chips in a highly compatible and facile way.  相似文献   

2.
The large intensities available with femtosecond (fs) laser pulses allow permanent structural modifications in transparent materials with high spatial resolution. Irradiation of self-standing transparent biopolymer films, such as collagen, pure and curcumin doped gelatine employing a 60-fs high-power 11 MHz Ti-Sapphire oscillator laser system linked to an optical microscope led to modifications and ablation. Swelling modifications consisting in the foaming of the irradiated area and formation of a single layer of bubbles arranged around the narrow ablation crater were investigated by optical, scanning force (SFM) and scanning electron (SEM) microscopy. These modifications occur at fluences below the respective ablation thresholds, i.e. ablation processes take place on modified swelled phases. The results are discussed in terms of local temperature increase, generation of thermoelastic stress, physico-chemical effects, and in terms of an incubation model, i.e. the accumulation of these phenomena upon successive pulse irradiation.  相似文献   

3.
Whispering gallery mode microresonators have been triggering considerable advances in science due to their ability to confine light within small dielectric volumes, which makes them suitable for a wide range of applications. Lithographic approaches have been the dominant technique for fabricating microresonators; however, they restrict the choice of materials due to their multistep processing nature. As an alternative, they report the direct laser fabrication of acrylic based hollow microcylinder resonators, via two‐photon polymerization, with good structural integrity and sidewall roughness of 1.5 nm, which make them promising candidates for photonic applications in the near‐infrared. Such polymeric microresonators exhibit finesse close to 103 and a quality factor of 1 105, a performance achieved without any additional processing step, which would restrict the choices of materials to be incorporated into the polymeric resonator. This advantage thereby broadens the widespread use of the polymeric microresonators, making them an excellent platform for lasing and nonlinear optics studies in the near‐infrared. © 2017 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2017 , 55, 569–574  相似文献   

4.
Yang Y  Liu AQ  Lei L  Chin LK  Ohl CD  Wang QJ  Yoon HS 《Lab on a chip》2011,11(18):3182-3187
This paper presents a tunable optofluidic waveguide dye laser utilizing two centrifugal Dean flows. The centrifugal Dean flow increases the light confinement of the dye laser by shaping a three-dimensional (3D) liquid waveguide from curved microchannels. The active medium with the laser dye is dissolved in the liquid core and pumped with an external pump laser to produce stimulated emission. The laser's Fabry-Pérot microcavity is formed with a pair of aligned gold-coated fiber facets to amplify the fluorescent emission. The advantage of the 3D optofluidic waveguide dye laser is its higher efficiency, thus to obtain lasing at a reduced threshold (60%) with higher output energy. The demonstrated slope efficiency is at least 3-fold higher than its traditional two-dimensional equivalent. In addition, the laser output energy can be varied on demand by tuning the flow rates of the two flows. This technique provides a versatile platform for high potential applications microfluidic biosensor and bioanalysis.  相似文献   

5.
Spectral filtering is an essential component of biophotonic methods such as fluorescence and Raman spectroscopy. Predominantly utilized in bulk microscopy, filters require efficient and selective transmission or removal of signals at one or more wavelength bands. However, towards highly sensitive and fully self-contained lab-on-chip systems, the integration of spectral filters is an essential step. In this work, a novel optofluidic solution is presented in which a liquid-core optical waveguide both transports sample analytes and acts as an efficient filter for advanced spectroscopy. To this end, the wavelength dependent nature of interference-based antiresonant reflecting optical waveguide technology is exploited. An extinction of 37 dB, a narrow rejection band of only 2.5 nm and a free spectral range of 76 nm using three specifically designed dielectric layers are demonstrated. These parameters result in an 18.4-fold increase in the signal-to-noise ratio for on-chip fluorescence detection. In addition, liquid-core waveguide filters with three operating wavelengths were designed for F?rster resonance energy transfer detection and demonstrated using doubly labeled oligonucleotides. Incorporation of high-performance spectral processing illustrates the power of the optofluidic concept where fluidic channels also perform optical functions to create innovative and highly integrated lab-on-chip devices.  相似文献   

6.
An integrated optofluidic platform for Raman-activated cell sorting   总被引:2,自引:0,他引:2  
Lau AY  Lee LP  Chan JW 《Lab on a chip》2008,8(7):1116-1120
We report on integrated optofluidic Raman-activated cell sorting (RACS) platforms that combine multichannel microfluidic devices and laser tweezers Raman spectroscopy (LTRS) for delivery, identification, and simultaneous sorting of individual cells. The system allows label-free cell identification based on Raman spectroscopy and automated continuous cell sorting. Two optofluidic designs using hydrodynamic focusing and pinch-flow fractionation are evaluated based on their sorting design and flow velocity effect on the laser trapping efficiency at different laser power levels. A proof-of-principle demonstration of the integrated optofluidic LTRS system for the identification and sorting of two leukemia cell lines is presented. This functional prototype lays the foundation for the development of a label-free cell sorting platform based on intrinsic Raman markers for automated sampling and sorting of a large number of individual cells in solution.  相似文献   

7.
An optofluidic device for surface enhanced Raman spectroscopy   总被引:2,自引:0,他引:2  
Wang M  Jing N  Chou IH  Cote GL  Kameoka J 《Lab on a chip》2007,7(5):630-632
We have developed an optofluidic device that improves the sensitivity of surface enhanced Raman spectroscopy (SERS) when compared to other SERS approaches. This device has a pinched and step microchannel-nanochannel junction that can trap and assemble nanoparticles/target molecules into optically enhanced SERS active clusters by using capillary force. These SERS active clusters provide an electromagnetic enhancement factor of approximately 10(8). In addition, due to the continuous capillary flow that can transport nanoparticles/target molecules into the junction sites, the numbers of nanoparticles/target molecules and SERS active sites are increased. As a result, the detection limit of SERS for adenine molecules was better than 10 pM.  相似文献   

8.
Y Hanada  K Sugioka  K Midorikawa 《Lab on a chip》2012,12(19):3688-3693
The demand for increased sensitivity in the concentration analysis of biochemical liquids is a crucial issue in the development of lab on a chip and optofluidic devices. We propose a new design for optofluidic devices for performing highly sensitive biochemical liquid assays. This design consists of a microfluidic channel whose internal walls are coated with a polymer and an optical waveguide embedded in photostructurable glass. The microfluidic channel is first formed by three-dimensional femtosecond laser micromachining. The internal walls of the channel are then coated by the dipping method with a polymer that has a lower refractive index than water. Subsequently, the optical waveguide is integrated with the microfluidic channel. The polymer coating on the internal walls permits the probe light, which is introduced by the optical waveguide, to propagate along the inside of the microfluidic channel. This results in a sufficiently long interaction length between the probe light and a liquid sample in the channel and thus significantly improves the sensitivity of absorption measurements. Using the fabricated optofluidic chips, we analyzed protein in bovine serum albumin to concentrations down to 7.5 mM as well as 200 nM glucose-D.  相似文献   

9.
10.
Discretely tunable optofluidic compound microlenses   总被引:1,自引:0,他引:1  
Fei P  He Z  Zheng C  Chen T  Men Y  Huang Y 《Lab on a chip》2011,11(17):2835-2841
We report a novel method to fabricate high zoom-ratio optofluidic compound microlenses using poly(dimethylsiloxane) with multi-layer architecture. The layered structure of deformable lenses, biconvex and plano-concave, are self-aligned as a group. The refractive index contrast of each lens, which is controlled by filling the chambers with a specific medium, is the key factor for determining the device's numerical aperture. The chip has multiple independent pneumatic valves that can be digitally switched on and off, pushing the liquid into the lens chambers with great accuracy and consistency. This quickly and precisely tunes the focal length of the microlens device from centimetres to sub-millimetre. The system has great potential for applications in portable microscopic imaging, bio-sensing, and laser beam configuration.  相似文献   

11.
W Song  AE Vasdekis  D Psaltis 《Lab on a chip》2012,12(19):3590-3597
The synergetic integration of photonics and microfluidics has enabled a wide range of optofluidic devices that can be tuned based on various physical mechanisms. One such tuning mechanism can be realized based on the elasticity of polydimethylsiloxane (PDMS). The mechanical tuning of these optofluidic devices was achieved by modifying the geometry of the device upon applying internal or external forces. External or internal forces can deform the elastomeric components that in turn can alter the optical properties of the device or directly induce flow. In this review, we discuss recent progress in tunable optofluidic devices, where tunability is enabled by the elasticity of the construction material. Different subtypes of such tuning methods will be summarized, namely tuning based on bulk or membrane deformations, and pneumatic actuation.  相似文献   

12.
In this work, we report the design, fabrication, and characterization of a tunable optofluidic microlens that focuses light within a microfluidic device. The microlens is generated by the interface of two co-injected miscible fluids of different refractive indices, a 5 M CaCl(2) solution (n(D) = 1.445) and deionized (DI) water (n(D) = 1.335). When the liquids flow through a 90-degree curve in a microchannel, a centrifugal effect causes the fluidic interface to be distorted and the CaCl(2) solution bows outwards into the DI water portion. The bowed fluidic interface, coupled with the refractive index contrast between the two fluids, yields a reliable cylindrical microlens. The optical characteristics of the microlens are governed by the shape of the fluidic interface, which can be altered by simply changing the flow rate. Higher flow rates generate a microlens with larger curvature and hence shorter focal length. The changing of microlens profile is studied using both computational fluid dynamics (CFD) and confocal microscopy. The focusing effect is experimentally characterized through intensity measurements and image analysis of the focused light beam, and the experimental data are further confirmed by the results from a ray-tracing optical simulation. Our investigation reveals a simple, robust, and effective mechanism for integrating optofluidic tunable microlenses in lab-on-a-chip systems.  相似文献   

13.
We report the procedures of machining microchannels on Vivak co-polyester thermoplastic substrates using a simple industrial CO(2) laser marker. To avoid overheating the substrates, we develop low-power marking techniques in nearly anaerobic environment. These procedures are able to machine microchannels at various aspect ratios. Either straight or serpent channel can be easily marked. Like the wire-embossed channel walls, the ablated channel surfaces become charged after alkaline hydrolysis treatment. Stable electroosmotic flow in the charged conduit is observed to be of the same order of magnitude as that in fused silica capillary. Typical dynamic coating protocols to alter the conduit surface properties are transferable to the ablated channels. The effects of buffer acidity on electroosmotic mobility in both bare and coated channels are similar to those in fused silica capillaries. Using video microscopy we also demonstrate that this device is useful in distinguishing the electrophoretic mobility of bare and latex particles from that of functionalized ones.  相似文献   

14.
Blakely JT  Gordon R  Sinton D 《Lab on a chip》2008,8(8):1350-1356
Microfluidics and fiber optics are integrated in-plane to achieve several flow-dependent particle trapping mechanisms on-chip. Each mechanism results from a combination of fluid drag and optical scattering forces. Parallel and offset fibers, orthogonally oriented to the flow, show cyclic cross-stream particle transit with flow-dependent particle trajectories and loss. Upstream-angled fibers with flow result in circulatory particle trajectories. Asymmetric angled fibers result in continuous particle circulation whereas symmetry with respect to the flow axis enables both stable trapping and circulation modes. Stable trapping of single particles, self-guided multi-particle arrays and particle assemblies are demonstrated with a single upstream-oriented fiber. Size tuning of trapped multiple particle assemblies is also presented. The planar interaction of fluid drag and optical forces results in novel possibilities for cost-effective on-chip diagnostics, mixing, flow rate monitoring, and cell analysis.  相似文献   

15.
This paper numerically and experimentally investigates and demonstrates the design of an optofluidic in-plane bi-concave lens to perform both light focusing and diverging using the combined effect of pressure driven flow and electro-osmosis. The concave lens is formed in a rectangular chamber with a liquid core-liquid cladding (L(2)) configuration. Under constant flow rates, the performance of the lens can be controlled by an external electric field. The lens consists of a core stream (conducting fluid), cladding streams (non-conducing fluids), and auxiliary cladding streams (conducting fluids). In the focusing mode, the auxiliary cladding stream is introduced to sandwich the biconcave lens to prevent light rays from scattering at the rough chamber wall. In the diverging mode, the auxiliary cladding liquid has a new role as the low refractive-index cladding of the lens. In the experiments, the test devices were fabricated in polydimethylsiloxane (PDMS) using the standard soft lithography technique. Ethanol, cinnamaldehyde, and a mixture of 73.5% ethylene glycol and 26.5% ethanol work as the core stream, cladding streams and auxiliary cladding streams. In the numerical simulation, the electric force acts as a body force. The governing equations are solved by a finite volume method on a Cartesian fixed staggered grid. The evolution of the interface was captured by the level set method. The results show that the focal length in the focusing mode and the divergent angle of the light beam in the diverging mode can be tuned by adjusting the external electric field at fixed flow rates. The numerical results have a reasonable agreement with the experimental results.  相似文献   

16.
In this paper we describe the use of a CO(2) laser for production of cavities and microstructures in poly(methyl methacrylate) (PMMA) by moving the laser beam over the PMMA surface in a raster pattern. The topography of the cavities thus produced is studied using stylus and optical profilometry and scanning electron microscopy (SEM). The microstructures display artifacts from the laser ablation process and we describe how the laser ablation parameters can be optimized in order to minimize these artifacts. Using this technique it is possible to generate structures with a depth from 50 microm and a minimum width of approximately 200 microm up to depth and widths of several mm, governed by the beam size and the laser settings.  相似文献   

17.
Z Shen  Y Zou  X Chen 《Lab on a chip》2012,12(19):3816-3820
We develop a simple method to determine the microdroplet features in a microfluidic chip fabricated by conventional soft lithography. Different sizes of microdroplets are generated through a typical microfluidic T-junction by adjusting the flow rates of the two immiscible liquids. Droplet size and content can be determined by monitoring the optofluidic signals reflected at the fluid-polydimethylsiloxane (PDMS) interface. The demonstrated droplet characterization system can be readily integrated with other microfluidic networks, making it promising for biochemical and biosensing applications.  相似文献   

18.
研究了POCl3-ZrCl4-Nd(CF3COO)3激光体系废液中锆和钕的回收方法,蒸馏回收POCl3后的废渣与碳酸钠溶液反应,其中的钕转化为碳酸钕沉淀,用盐酸溶解并将其中不溶的磷酸锆滤出,再用草酸沉淀,灼烧后得到氧化钕,其中未检测出锆;碳酸锆的络合物在加入9mol/LHCl后析出白色氯氧化锆,经重结晶后,所得氯氧化锆中钕的含量小于0.05%.  相似文献   

19.
We present the first integration of fluidically tunable filters with a separate particle detection channel on a single planar, optofluidic chip. Two optically connected, but fluidically isolated liquid-core antiresonant reflecting optical waveguide (ARROW) segments serve as analyte and spectral filter sections, respectively. Ultrasensitive detection of fluorescent nanobeads with high signal-to-noise ratio provided by a fluidically tuned excitation notch filter is demonstrated. In addition, reconfigurable filter response is demonstrated using both core index tuning and bulk liquid tuning. Notch filters with 43 dB rejection ratio and a record 90 nm tuning range are implemented by using different mixtures of ethylene glycol and water in the filter section. Moreover, absorber dyes and liquids with pH-dependent transmission in the filter channel provide additional spectral control independent of the waveguide response. Using both core index and pH control, independent filter tuning at multiple wavelengths is demonstrated for the first time. This extensive on-chip control over spectral filtering as one of the fundamental components of optical particle detection techniques offers significant advantages in terms of compactness, cost, and simplicity, and opens new opportunities for waveguide-based optofluidic analysis systems.  相似文献   

20.
It was shown that, in contrast to the Purex process using aggressive and environmentally hazardous 8M HNO3 solutions for dissolving spent oxide nuclear fuel (SNF), this fuel can be easily dissolved in aqueous subacid ([H+] ∼0.1 M) solutions of Fe(III) nitrate (chloride) with partial separation of uranium and plutonium from fission products (FP). The low acidity of the solutions obtained (pH ∼1) allows direct application of modern technologies of finishing processing of nuclear fuel by fluoride, carbonate, oxalate, or peroxide precipitation of uranium and plutonium. It was established that U(VI) is isolated from nearly neutral nitric acid solutions as a poorly soluble uranyl hydroxylaminate complex after adding hydroxylamine. It was shown that on thermal decomposition at 200–300°C under ambient atmosphere this compound converts into uranium dioxide. A similar approach was applied to obtain mixed oxide uranium-plutonium fuel (MOX fuel).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号