首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The octanol-water distribution constant, commonly called partition coefficient, Po/w, is a parameter often retained as a measure of the hydrophobicity of a molecule. log Po/w, for a given molecule, can be conveniently evaluated constructing correlation lines between standard retention factor logarithms (log k) in reversed-phase liquid chromatography (RPLC) and standard log Po/w values. Many compounds of pharmaceutical interest can be quite hydrophobic and have, simultaneously, basic nitrogen atoms or acidic sulfur containing groups in their structure. This renders them ionizable. The hydrophobicity of the molecular drug form (Po/w value) is completely different from its ionic form (log Po/w(+ or -) value). The actual hydrophobicity of such ionizable molecule depends on the pH. It can be represented by an apparent Papp value that takes into account the amount of compound in its molecular and ionic state combining the Po/w and Po/w(+ or -) values. In this work, log k in RPLC for ionizable as well as non-ionizable pharmaceutical compounds with different therapeutic properties (10 beta-blockers, seven tricyclic antidepressants (TA), eight steroids and 12 sulfonamides) were correlated with log Po/w. Similar correlations were done between log k and the corrected log Papp values at pH 3. Aqueous-organic mobile phases containing acetonitrile (conventional RPLC) and micellar-organic mobile phases (micellar liquid chromatography, MLC), prepared with the anionic surfactant sodium dodecyl sulfate and the organic solvents acetonitrile, propanol or pentanol, were also used to elute the compounds. All mobile phases were buffered at pH 3. Using conventional retention RPLC data, the correlation of log k with log Po/w, was satisfactory for steroids because they cannot ionize. For ionizable beta-blockers and TAs, the use of log Papp values improved the quality of the correlations, but yielded similar results for sulfonamides. In MLC, since an electrostatic interaction is added to hydrophobic forces, poorer correlations were obtained in all cases. The retention data obtained in RPLC also seems to correlate better with the biological activity of the drugs.  相似文献   

2.
The screening capability of micellar liquid chromatography (MLC) is discussed using the reported chromatographic data of several sets of compounds (amino acids, beta-blockers, diuretics, phenethylamines, phenols, polynuclear aromatic hydrocarbons, steroids and sulfonamides) and new results (sulfonamides and steroids). The chromatographic data are treated with an interpretive optimisation resolution procedure to obtain the best separation conditions. Usually, the pH and the concentration of surfactant (sodium dodecyl sulfate, SDS, or cetyltrimethylammonium bromide) for the optimal mobile phase were 2.5-3 and < 0.12 M, respectively. The nature and concentration of organic solvent depended on the polarity of the eluted compounds: a low volume fraction of propanol (approximately 1%, v/v) was useful to separate the amino acids, with log P(o/w) < -1 (where P(o/w) is the octanol-water partition coefficient). A greater concentration of this solvent (approximately 5-7%) was needed for compounds in the range -1 < log P(o/w) < 2, as with the studied diuretics and sulfonamides, and a high concentration of propanol (approximately 15%) or a low concentration of butanol (< 10%) had to be used for less polar compounds with 1 < log P(o/w) < 3, such as the beta-blockers. Pentanol (< 6%) was more suitable for the even less polar compounds with log P(o/w) > 3, such as the steroids. For basic drugs such as the phenethylamines (0 < log P(o/w) < 1.7), eluted with a micellar eluent of anionic SDS, propanol was too weak. A study is also shown for mixtures of sulfonamides (log P(o/w) = -1.2 to 1.7) and steroids (log P(o/w) = 3.0-8.1) eluted from conventional C18 columns with SDS mobile phases containing acetonitrile and 1-pentanol, respectively, which are compared with classical acetonitrile-water and methanol-water mixtures. The results complement a previous study on beta-blockers (log P(o/w) = -0.03 to 2.8) and reveal that MLC is a very competitive technique for the screening of compounds against conventional RPLC, due to its peculiar behaviour with regard to the selectivity and elution strength. The concentration of organic solvent needed to obtain sufficiently low retention times (even for highly hydrophobic steroids with log P(o/w) = 7-8) is also appreciably smaller for MLC, which reduces the environmental impact of the mobile phases.  相似文献   

3.
Screening of diuretics in urine is feasible through direct injection of the samples into the chromatographic system and isocratic reversed-phase liquid chromatography (RPLC) with micellar-organic mobile phases of sodium dodecyl sulfate (SDS) and 1-propanol. The surfactant coverage of the chromatographic column makes the addition of organic competing amines less necessary than in conventional aqueous-organic RPLC to achieve well-shaped peaks. Also, the range of elution strengths of micellar mobile phases required to elute mixtures of hydrophobic and hydrophilic diuretics is smaller. This allows the isocratic separation of the diuretics within adequate analysis times. An interpretive methodology is applied to optimise the resolution of a mixture of 15 diuretics of diverse polarity and acid-base behaviour (althiazide, amiloride, bendroflumethiazide, benzthiazide, bumetanide, canrenoic acid, chlorthalidone, ethacrynic acid, furosemide, piretanide, probenecid, torasemide, triamterene, trichloromethiazide and xipamide), using pH and concentrations of surfactant and organic modifier in the mobile phase as separation factors. Twelve diuretics were resolved in 25 min using 0.055 M SDS-6.0% 1-propanol at pH 3.0. The mixture of 15 diuretics was also resolved with two mobile phases showing complementary behaviour: 0.05 M SDS-5.6% 1-propanol at pH 5.4 and 0.11 M SDS-5.4% 1-propanol at pH 4.2. The results were applied to the analysis of urine samples with limits of detection similar to those usually reported for aqueous-organic RPLC, taking into account that the samples were injected without any previous treatment to separate or preconcentrate the analytes.  相似文献   

4.
5.
A simple, sensitive, and precise micellar liquid chromatographic method for simultaneous analysis of sulfamethoxazole and trimethoprim, with ultraviolet detection at 245 nm, has been developed, validated, and used for determination of the compounds in commercial pharmaceutical products. The compounds were well separated on a Hypersil ODS reversed-phase column at 35°C by use of a mobile phase consisting of 0.1M sodium dodecyl sulfate in a 2:98 (V/V) mixture of 1-butanol and pH 3.0 phosphate buffer solution at a flow rate of 1.0 mL min?1. A comparative study of the performance of reversed-phase liquid chromatography with aqueous-organic or micellar-organic mobile phases for separation of sulfamethoxazole and trimethoprim is reported. The study showed that micellar liquid chromatography (MLC) and reversed-phase liquid chromatography (RP HPLC) are of similar efficiency, sensitivity, and selectivity for determination of sulfamethoxazole and trimethoprim.  相似文献   

6.
Use of micellar mobile phases in reversed-phase liquid chromatography (RPLC) results in hydrophobic and electrostatic sites for interaction. Modified stationary phases in micellar liquid chromatography (MLC) are structurally similar to biomembranes. To confirm this we focused on the effects of the type and concentration of surfactant (Brij 35, SDS, and CTAB) and mobile phase pH on the retention of antihypertensive drugs on modified C18 stationary phases. Quantitative retention-activity relationships are proposed for the drugs and the different surfactants and compared with those obtained using aqueous–organic mobile phases. Finally, a correlation was obtained between the logarithm of retention factors (log k) and the toxicity (LD50) of antihypertensive drugs. Revised: 14 September 2005 and 4 April 2006  相似文献   

7.
The simultaneous isocratic separation of a mixture of five phenolic acids and four flavonoids (two important groups of natural polyphenolic compounds with very different polarities) was investigated in three different RPLC modes using a hydro‐organic mobile phase, and mobile phases containing SDS at concentrations below and above the critical micellar concentration (submicellar LC and micellar LC (MLC), respectively). In the hydro‐organic mode, methanol and acetonitrile; in the submicellar mode methanol; and in the micellar mode, methanol and 1‐propanol were examined individually as organic modifiers. Regarding the other modes, MLC provided more appropriate resolutions and analysis time and was preferred for the separation of the selected compounds. Optimization of separation in MLC was performed using an interpretative approach for each alcohol. In this way, the retention of phenolic acids and flavonoids were modeled using the retention factors obtained from five different mobile phases, then the Pareto optimality method was applied to find the best compatibility between analysis time and quality of separation. The results of this study showed some promising advantages of MLC for the simultaneous separation of phenolic acids and flavonoids, including low consumption of organic solvent, good resolution, short analysis time, and no requirement of gradient elution.  相似文献   

8.
The chromatographic behavior (retention, elution strength, efficiency, peak asymmetry and selectivity) of some aromatic diamines in the presence of methanol with or without anionic surfactant SDS in the four different reversed phased liquid chromatographic (RPLC) modes, i.e., hydro-organic, micellar (MLC), low submicellar (LSC) and high submicellar (HSC), was investigated. In the three surfactant-mediated modes, the surfactant monomers coat the stationary phase even up to 70 % methanol; this results in the suppression of peak tailing (by masking the silanol groups on the stationary phase). In MLC and HSC, the solute retention decreases by increasing the surfactant concentration, while this situation was reversed in LSC. In the region between MLC and HSC modes (25–50 % methanol), retention of late eluting solutes was increased by increasing methanol content which is seemingly due to disaggregation of SDS micelles. Changes in selectivity were observed after changing the concentrations of SDS and methanol, in a greater extent when concentration of SDS was changed. Among the four studied RPLC modes, HSC showed the best efficiency with nearly symmetrical peaks. Prediction of retention of solutes in HSC based on a mechanistic retention model combined with Pareto-optimality method allowed the full resolution of target diamines in practical analysis times.  相似文献   

9.
通过比较药物在不同类型表面活性剂的胶束液相色谱中的容量因子与药物的醇-水分配系数(log P)的相关性, 发现药物在非离子型表面活性剂Brij35作为流动相的胶束液相色谱中的容量因子与其文献中报道的log P间有一定的相关性, 进一步考察了Brij35浓度对药物保留的影响, 并建立了药物在不同浓度的Brij35胶束液相色谱中的容量因子与文献中log P的相关关系, 该方法简单、快速, 将为药物的疏水性评价提供重要的参考价值.  相似文献   

10.
11.
Li J  Sun J  Cui S  He Z 《Journal of chromatography. A》2006,1132(1-2):174-182
Linear solvation energy relationships (LSERs) amended by the introduction of a molecular electronic factor were employed to establish quantitative structure-retention relationships using immobilized artificial membrane (IAM) chromatography, in particular ionizable solutes. The chromatographic indices, log k(IAM), were determined by HPLC on an IAM.PC.DD2 column for 53 structurally diverse compounds, including neutral, acidic and basic compounds. Unlike neutral compounds, the IAM chromatographic retention of ionizable compounds was affected by their molecular charge state. When the mean net charge per molecule (delta) was introduced into the amended LSER as the sixth variable, the LSER regression coefficient was significantly improved for the test set including ionizable solutes. The delta coefficients of acidic and basic compounds were quite different indicating that the molecular electronic factor had a markedly different impact on the retention of acidic and basic compounds on IAM column. Ionization of acidic compounds containing a carboxylic group tended to impair their retention on IAM, while the ionization of basic compounds did not have such a marked effect. In addition, the extra-interaction with the polar head of phospholipids might cause a certain change in the retention of basic compounds. A comparison of calculated and experimental retention indices suggested that the semi-empirical LSER amended by the addition of a molecular electronic factor was able to reproduce adequately the experimental retention factors of the structurally diverse solutes investigated.  相似文献   

12.
13.
Mass-action model of surfactant micelle formation has been used to develop a conceptual retention model in micellar liquid chromatography (MLC). The retention model bases on the consideration of the changes of the sorbate microenvironment at its transferring from the mobile phase (hybrid micellar eluent) to the stationary phase (a modified surface of alkyl-bounded sorbent). Principal retention equation contains the characteristics of hybrid micelles (critical micelle concentration, degree of counterion binding, partition coefficient of modifier between aqueous solution and micellar pseudo-phase) as well as three fitting parameters. The fitting parameters are an absolute term and coefficients that are equal to the number of molecules of surfactant and modifier, which are attached/detached by sorbate transferring from a hybrid micellar eluent to a modified surface of the stationary phase. On the MLC separation of five antibiotics of rubomicin derivatives and four esters of 4-hydroxybenzoic acid the model of the change of sorbate microenvironment has been tested. The adequateness of model to experimental data has been shown. A simple three-parameter function connecting log k with log cS and log cR that provides a high goodness-of-fit follows from principal retention equation (cS and cR are the molar concentrations of surfactant and organic modifier in the micellar eluent, respectively).  相似文献   

14.
15.
An RPLC was developed to rapidly determine lipophilicity of neutral and basic compounds using three base deactivated RPLC stationary phases particularly designed for the analysis of basic compounds, namely, Supelcosil ABZ(+)Plus, Discovery RP Amide C16, and Zorbax Extend C18. The work consisted of three sets of experiments. In the first log kw values of neutral compounds were extrapolated using hydroorganic mobile phases at different compositions. Good correlation between log kw and log Poct indicated that the method was appropriate for these supports, without adding a silanol masking agent. In the second set of experiments, isocratic log k values of neutral and basic compounds were measured with three different mobile phases. The best estimation of lipophilicity was obtained for neutral and basic compounds when the secondary interactions were strongly reduced (i. e., when basic compounds were under their neutral form). In the third set of experiments, isocratic retention factors of basic compounds (in their neutral form) were measured with a high-pH mobile phase, on a chemically stable support (Zorbax Extend C18). Under these chromatographic conditions, correlation between the isocratic retention factors and log Poct (log D10.5) for basic compounds was similar to that for neutral compounds.  相似文献   

16.
The retention factor (k) and retention index (I) of homologous series compounds such as alkylbenzenes (BZ), alkylaryl ketones, alkylbenzoates, and alkylparabens in microemulsion electrokinetic chromatography (MEEKC) with suppressed electroosmosis were investigated in a wide range of SDS concentrations ([SDS]), temperatures, and concentrations of organic cosolvents (phi). Using BZ as standards, the retention indices of other homologous series compounds were determined and they were found to be independent of [SDS] and temperature, while are dependent on the types and concentrations of organic cosolvents. The retention factor linearly increases with increasing [SDS], while linearly decreases with increasing temperature. The value of log k linearly decreases with increasing phi for methanol, ethanol, or ACN, while decreases by a second-degree polynomial with increasing phi for 2-propanol. Excellent agreement was found between the observed and predicted values of log k of analytes in MEEKC at given [SDS] and phi, where the predicted values were obtained from modified equations of the linear relationship of log k as functions of [SDS], the number of carbons, and phi. Therefore, both k and I can be used for peak identification of homologous series compounds.  相似文献   

17.
A simple model is proposed that relates the parameters describing the peak width with the retention time, which can be easily predicted as a function of mobile phase composition. This allows the further prediction of peak shape with global errors below 5%, using a modified Gaussian model with a parabolic variance. The model is useful in the optimisation of chromatographic resolution to assess an eventual overlapping of close peaks. The dependence of peak shape with mobile phase composition was studied for mobile phases containing acetonitrile in the presence and absence of micellised surfactant (micellar-organic and hydro-organic reversed-phase liquid chromatography, RPLC). In micellar RPLC, both modifiers (surfactant and acetonitrile) were observed to decrease or improve the efficiencies in the same percentage, at least in the studied concentration ranges. The study also revealed that the problem of achieving smaller efficiencies in this chromatographic mode, compared to hydro-organic RPLC, is not only related to the presence of surfactant covering the stationary phase, but also to the smaller concentration of organic solvent in the mobile phase.  相似文献   

18.
19.
The retention characteristics of 21 basic pharmaceutical substances with a considerable difference in hydrophobicity (octanol-water partition coefficients, log P, between -0.026 and 6.45) are considered on an immobilized artificial membrane column, with a micellar liquid chromatography and a micellar electrokinetic capillary chromatography method. Utilising principal component analysis (PCA), it is seen that although the main retention principle is the same, the above methods as well as more classical RP-HPLC methods vary in secondary retention mechanisms. Combining the results of different methods a differentiation of the substances into their pharmacological families can be seen with PCA. The high correlations of the retention characteristics with log P and a biological parameter seem little affected by the method used.  相似文献   

20.
硅胶色谱柱的亲水作用保留机理及其影响因素   总被引:1,自引:0,他引:1  
李瑞萍  袁琴  黄应平 《色谱》2014,32(7):675-681
亲水作用色谱(HILIC)是替代反相色谱(RPLC)分离强极性及亲水性化合物的另一色谱模式,其分离机理与RPLC有很大不同,具有和RPLC互补的选择性。在HILIC模式中,采用正相色谱(NPLC)中的极性固定相及含高浓度有机溶剂(通常为乙腈)的水溶液为流动相。硅胶是开发最早、研究最为深入及应用最为广泛的HILIC固定相,本文介绍了硅胶色谱柱的HILIC保留机理,详细概述了操作条件如硅胶柱类型、流动相组成及柱温对HILIC分离的影响,并对硅胶填料色谱柱的HILIC模式的发展方向与应用前景进行了展望。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号