首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple and sensitive reversed-phase high performance liquid chromatographic method (HPLC) has been developed and validated for the routine analysis of diltiazem in human plasma and the study of the pharmacokinetics of the drug in the human body. Diltiazem and diazepa (internal standard) were extracted with a mixed organic solution of hexane, chloroform and isopropanol (60:40:5, v/v/v), and then HPLC separation of the drugs was performed on an Spherisorb C(18) column and detected by ultraviolet absorbance at 239 nm. The use of methanol-water solution (containing 2.8 mm triethylamine, 80:20, v/v) as the mobile phase at a fl ow-rate of 1.2 mL/min enables the baseline separation of the drugs free from interferences with isocratic elution. The method was linear in the clinical range 0-300 ng/mL and the lower limit of detection of diltiazem in plasma was 3 ng/mL. The range of percentage of relative standard deviation (%RSD) was from 3.5 to 6.8% for within-day analyses and from 6.2 to 8.4% for between-day analyses, respectively. The extraction recoveries of diltiazem from spiked human plasma (n = 5) at three concentrations were 91.4-104.0%. The method has been used to determine diltiazem in human plasma samples from eight volunteers who had taken diltiazem hydrochloride slow release tables and the data obtained was fitted with a program on computer to study the pharmacokinetics. The results showed that the peak level in plasma approximately averaged 118.5 +/- 14.3 ng/mL at 3.1 +/- 0.4 h, and the areas under the drug concentration curves (AUC) was 793.1 +/- 83.1 ng.h/mL.  相似文献   

2.
A simple and reliable high-performance liquid chromatographic (HPLC) method has been developed for the determination of nodakenin in rat plasma. The concentration of nodakenin was determined in plasma samples after deproteinization with methanol using hesperidin as internal standard. HPLC analysis was performed on a Diamonsil C(18) analytical column using acetonitrile-water (25:75, v/v) as the mobile phase and a UV detection at 330 nm. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day variation). The extraction recoveries were 91.3 ± 10, 87.8 ± 4.8 and 92.6 ± 5.1 at concentrations of 0.500, 5.00 and 40.0 μg/mL, respectively. The standard curve for nodakenin was linear (r(2) ≥ 0.99) over the concentration range 0.250-50.0 μg/mL with a lower limit of quantification of 0.250 μg/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were not higher than 12% and the accuracy (relative error, RE) was within ± 5.8% at three quality control levels. The validated method was successfully applied for the evaluation of the pharmacokinetics of nodakenin in rats after oral administration of Rhizoma et Radix Notopterygii decoction and nodakenin solution.  相似文献   

3.
A simple and sensitive reversed-phase high-performance liquid chromatography method with UV detection is developed and validated for the determination of 6,7-dimethoxycoumarin in rat plasma and comparative analysis of its pharmacokinetics after intragastric administration of 6,7-dimethoxycoumarin and three different decoctions of yinchenhao tang. The plasma samples are deproteinated with acetonitrile. The components are separated on a Kromasil C18 column (250 x 4.6 mm, 5 microm,) with methanol-1% acetic acid solution-tetrahydrofuran (30:63:7, v/v/v) as the mobile phase, and the UV detector is set at 340 nm. Coumarin is used as an internal standard. The linear calibration curve is obtained in the concentration range of 25-2500 ng/mL. The lower limit of quantitation of the method is 25 ng/mL. The intra- and inter-day precision are less than 12%, and the accuracy determined with relative error ranges from -2.9% to 1.7%. The data obtained from rat plasma are analyzed with Topfit 2.0 Pharmacokinetic Software. With pharmacokinetic analysis, the main parameters after intragastric administration of 6,7-dimethoxycoumarin, Herba Artemisiae Scopariae decoction, Artemisiae Scopariae decoction plus Radix et Rhizoma Rhei and Fructus Gardeniae decoction, yinchenhao tang are as follows: T(1/2) is 0.29, 1.30, 1.07, and 1.75 h, AUC(-->t) is 919.1, 1215.0, 2035.3, and 2537.9 ng-h/mL, AU(0-->) is 928.5, 1325.9, 2094.4, and 2612.6 ng x h/ mL, respectively.  相似文献   

4.
A precise and reproducible HPLC method has been established and validated for determination of salvianolic acid B (SalB) in rat plasma after oral administration of Radix Salviae Miltiorrhizae extract. Liquid-liquid extraction was adopted for the sample preparation. Separation was accomplished on a C(18) column with a linear gradient elution consisting of acetonitrile and aqueous phosphoric acid. Ultraviolet detection was at 280 nm. The method was validated over the concentration range 10.8-259.4 microg/mL using 1 mL of plasma. The assay was linear over this concentration range with a coefficient of variation less than 7%. The extraction recovery of SalB was within the range 71-83% with RSD 11%. The mean recovery of the internal standard was 84% (n = 6) with RSD of 5.6%. This method is suitable to determine SalB in plasma and to investigate the pharmacokinetics of SalB.  相似文献   

5.
A simple HPLC method was developed for determination of quercitrin and isoquercitrin in rat plasma. Reversed-phase HPLC was employed for the quantitative analysis using kaempferol-3-O-beta-D-glucopyranoside-7-O-alpha-L-rhamnoside as an internal standard. Following extraction from the plasma samples with ethyl acetate-isopropanol (95:5, v/v), these two compounds were successfully separated on a Luna C(18) column (250 x 4.6 mm, 5 microm) with isocratic elution of acetonitrile-0.5% aqueous acetic acid (17:83, v/v) as the mobile phase. The flow-rate was set at 1 mL/min and the eluent was detected at 350 nm for both quercitrin and isoquercitrin. The method was linear over the studied ranges of 50-6000 and 50-5000 ng/mL for quercitrin and isoquercitrin, respectively. The intra- and inter-day precisions of the analysis were better than 13.1 and 13.2%, respectively. The lower limits of quantitation for quercitrin and isoquercitrin in plasma were both of 50 ng/mL. The mean extraction recoveries were 73 and 61% for quercitrin and isoquercitrin, respectively. The validated method was successfully applied to pharmacokinetic studies of the two analytes in rat plasma after the oral administration of Hypericum japonicum thunb. ethanol extract.  相似文献   

6.
An improved simple, rapid and accurate HPLC method for quantification of doxorubicin derived from micelle-encapsulated or liposome-encapsulated doxorubicin formulation in rat plasma was described. The mobile phase consisting of a mixture of methanol-water [containing 0.1% formic acid anhydrous and 0.1% ammonia solution (25%), pH 3.0], 60:40, was delivered at a flow rate of 1.0 mL/min. Sample preparation for micelle- or liposome-encapsulated doxorubicin in rat plasma were achieved directly by protein precipitation with acetonitrile. Doxorubicin and daunorubicin (internal standard, IS) were separated on a C(18) reversed-phase HPLC column and quantified by a fluoresence detection with an excitation wavelength of 475 nm and an emission wavelength of 580 nm. The linearity was obtained over the range of 5.0-1000.0 ng/mL and 1.0-200.0 microg/mL for doxorubicin and the lower limit of quantitation was 5.0 ng/mL. For each level of quality control samples, inter- and intra-assay precision was less than 9.6 and 5.1% (relative standard deviation), respectively, and percentage error was within +/-2.6%. The extraction recoveries of doxorubicin in the range of 10 ng/mL to 100 microg/mL in rat plasma were between 94.1 and 105.6%. This method was successfully applied to the pharmacokinetic study of doxorubicin formulations after i.v. administration to rats.  相似文献   

7.
A simple, sensitive and selective high-performance liquid chromatographic (HPLC) method with UV detection (306 nm) was developed and validated for determination of tenatoprazole, a novel proton-pump inhibitor, in dog plasma. Tenatoprazole and internal standard (pantoprazole) were extracted into diethyl ether and separated using an isocratic mobile phase of 10 mm phosphate buffer (pH4.7)-acetonitrile (70:30, v/v) on a Diamonsil C(18) column (150 x 4.6 mm, 5 microm). The retention times for tenatoprazole and internal standard were 7.1 and 12.3 min, respectively. No endogenous interferences were observed. This HPLC method was fully validated. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 20%. A linear range of 0.02-5.0 microg/mL was established. The interday and intraday precisions were within RSD 13.4-10.1 and 4.6-1.4%, respectively. This method developed can be easily applied to the pharmacokinetic study of tenatoprazole in dog plasma after oral administration of an enteric-coated capsule. The plasma concentration of tenatoprazole from six dogs showed a mean C(max) of 2.63 microg/mL at T(max) of 1.89 h. The bioavailability of tenatoprazole was improved by administration of enteric-coated capsule.  相似文献   

8.
To quantify naringenin and hesperetin in rat plasma after oral administration of Da-Cheng-Qi decoction, a famous purgative traditional Chinese medicine, a high-performance liquid chromatography-tandem mass spectrometry method was developed and validated. The HPLC separation was carried out on a Zorbax SB-C(18) column using 0.1% formic acid-methanol as mobile phase and estazolam as internal standard after the sample of rat plasma had been cleaned up with one-step protein precipitation using methanol. Atmospheric pressure chemical ionization in the positive ion mode and selected reaction monitoring method was developed to determine the active components. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-batch variation). The recoveries of naringenin and hesperetin were 72.8-76.6 and 75.7-77.2%, respectively. Linearity in rat plasma was observed over the range of 0.5-250 ng/mL (r2 > 0.99) for both naringenin and hesperetin. The accuracy and precision were well within the acceptable range and the relative standard deviation of the measured rat plasma samples was less than 15% (n = 5). The validated method was successfully applied for the evaluation of the pharmacokinetics of naringenin and hesperetin administered to six rats.  相似文献   

9.
A simple, rapid, selective and sensitive HPLC‐UV method has been developed and validated for the determination of ponicidin in rat plasma. The analyte was extracted from rat plasma by liquid–liquid extraction with ethyl acetate as the extraction solvent. The LC separation was performed on a Zorbax Eclipse XDB C18 analytical column (150 × 4.6 mm i.d., 5 µm) with an isocratic mobile phase consisting of methanol–water–phosphoric acid (45:55:0.01, v/v/v) at a flow rate of 1.0 mL/min. There was a good linearity over the range of 0.1–25 µg/mL (r = 0.9995) with a weighted (1/C2) least square method. The lower limit of quantification was proved to be 0.1 µg/mL. The accuracy was within ±10.0% in terms of relative error and the intra‐ and inter‐day precisions were less than 9.1% in terms of relative standard deviation. After validation, the method was successfully applied to characterize the pharmacokinetics of ponicidin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
Copen is a derivative obtained from the structural modification of osthole, which inhibits tumoral proliferation in many tumor cell lines. A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was established for the quantification of copen in rat plasma. After a simple sample preparation procedure by one‐step protein precipitation with methanol, copen and bicalutamide (internal standard, IS) were chromatographed on a Zorbax SB‐C18 (4.6×100 mm, 1.8 µm) column with a mobile phase consisting of methanol–5 mm ammonium formate water with 0.1% formic acid (80:20, v/v). MS detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction monitoring mode with a positive eletrospray ionization source. The assay was validated in the concentration range of 51.58–20630 ng/mL, with a limit of quantitation (LOQ) of 51.58 ng/mL. The intra‐ and inter‐day precisions (relative standard deviation) were ≤3.21 and ≤11.3%, respectively, with accuracy (%) in the range of 94.66–102.1%. The method was fully validated in a study of the pharmacokinetics of copen (25 mg/kg) after intragastric administration in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
Lobaplatin, consisting of two diastereoisomers, is a third‐generation platinum antineoplastic agent that has shown encouraging anticancer activity in a variety of tumor types. To investigate any stereospecificity in the pharmacokinetics of lobaplatin, a novel, simple, rapid and sensitive supercritical fluid chromatography with tandem mass spectrometry method was developed for the simultaneous quantitation of lobaplatin diastereoisomers in rat plasma. After a simple protein precipitation with methanol, the analytes and dexpantoprazole (internal standard) were chromatographed on an Acquity UPC2 system with a Chiralcel OZ‐RH column using a mobile phase consisting of carbon dioxide and methanol (65:35, v/v) at 40°C over 6 min. The assay was linear over a concentration range of 25–15 000 ng/mL for both diastereoisomers using 100 μL of rat plasma for sample preparation. The lower limit of quantification was 25 ng/mL for both compounds, which was sufficient to detect the diastereoisomers in the incurred samples within this study. Intra‐ and inter‐day precisions were below 11.8% and the accuracies were below 4.5%. The validated method was successfully applied to a pharmacokinetic study after an intravenous administration of 7.6 mg/kg lobaplatin to rats. There was no apparent stereospecificity in the pharmacokinetics between the two diastereoisomers of lobaplatin.  相似文献   

12.
A sensitive and simple HPLC method was developed for the simultaneous quantification of berberine and lysergol in rat plasma. The chromatographic separation was achieved on a C18 column using isocratic elution with methanol–acetonitrile–0.1% ortho‐phosphoric acid (25:20:55, v/v/v), pH adjusted to 6.5 with triethylamine and detected at a UV wavelength of 230 nm. The extraction of the berberine and lysergol from the rat plasma with methylene chloride resulted in their high recoveries (82.62 and 90.17%). HPLC calibration curves for both berberine and lysergol based on the extracts from the rat plasma were linear over a broad concentration range of 50–1000 ng/mL. The limit of quantification was 50 ng/mL. Intra‐ and inter‐day precisions were <15% and accuracy was 87.12–92.55% for berberine and 87.01–92.26% for lysergol. Stability studies showed that berberine and lysergol were stable in rat plasma for short‐ and long‐term period for sample preparation and analysis. The described method was successfully applied to study the pharmacokinetics of berberine as well as lysergol following oral administration in Sprague–Dawley rats. The results of the study inferred that lysergol improved the oral bioavailability of berberine. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, rapid, and sensitive HPLC method based on 9H‐fluoren‐9‐ylmethyl chloroformate derivatization for the quantification of sertraline in rat plasma has been developed, requiring a plasma sample of only 0.1 mL, which was deproteinized and derivatized for 5 min in two single steps. The obtained derivative was stable at room temperature and was determined by HPLC using a fluorescence detector. The analytical column was a C(18) column and the mobile phase was acetonitrile and water (80:20, v/v). Calibration curves were linear in the range of 10–500 ng/mL. The limit of detection was approximately 3 ng/mL, and the lower limit of quantification was established at 10 ng/mL. The bias of the method was lower than 10%, and the within day as well as between day, relative standard deviations were lower than 12%. This analytical method was successfully applied to characterize sertraline pharmacokinetics in rats following intravenous (t1/2 = 213 ± 48 min, Cl = 43.1 ± 8.7 mL/min, Vd = 11560 ± 1861 mL) and oral (Cmax = 156 ± 76 ng/mL, tmax = 63.8 ± 16.3 min) administration of 2 and 5 mg, respectively.  相似文献   

14.
Wu X  Wang R  Xie H  Wang J  Jia Z  Zhang Q  Wang X 《色谱》2011,29(12):1205-1209
建立了快速检测大鼠血浆中普萘洛尔对映体浓度的柱切换-高效液相色谱法。将自制限进填料柱作为预处理柱,通过直接进样方式,使普萘洛尔对映体在预处理柱上保留,同时除去血浆中的蛋白质等大分子;再通过柱切换技术,使普萘洛尔对映体在键合型纤维素-三(3,5-二甲基苯基氨基甲酸酯)(Chiralcel OD-RH)分析柱上得到手性拆分。通过条件优化,确定切换前预处理流动相为硼酸盐缓冲液(pH 8.5)-甲醇(95:5, v/v),流速为1.0 mL/min;切换后分析流动相为异丙醇-乙醇-0.2 mmol/L硼酸盐缓冲液(pH 8.5)(30:30:40, v/v/v),流速为0.8 mL/min;切换时间为3 min;柱温为25 ℃;检测波长为293 nm。普萘洛尔两对映体在25~500 mg/L的质量浓度范围内具有良好的线性关系(r=0.9995), 3个加标水平(50、100、250 mg/L)的平均回收率为97.89%~101.56%,日内和日间精密度均小于5%。该方法简便、快速、灵敏、准确,适于血浆样本中手性药物的药代动力学研究。  相似文献   

15.
A sensitive HPLC/ESIMS method was established for the determination of manidipine in human plasma and pharmacokinetics study. After basified plasma with ammonia, manidipine and the internal standard (IS) (felodipine) were extracted with n-hexane and separated on a Hypersil ODS2 column with a mobile phase of methanol-5 mm ammonium acetate solution containing 0.1% acetic acid (85:15, v/v). MS determination was performed by electrospray ionization in the selected ion monitoring mode. Manidipine was monitored at m/z 611.4 and IS at m/z 384. The assay had a calibration range from 0.2 to 20 ng/mL and a lower limit of quantification of 0.1 ng/mL. The method has been successfully applied to the pharmacokinetic study in healthy volunteers.  相似文献   

16.
A simple, reliable HPLC method with UV detection (295 nm) in rat plasma was developed and validated for quantification of tenatoprazole, a novel proton pump inhibitor, which is in clinical trials. Following a single-step liquid-liquid extraction, the analyte and internal standard were separated using an isocratic mobile phase on a reverse phase C(18) column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 10%. A linear dynamic range of 20-6000 ng/mL was established. This HPLC method was validated with between-batch and within-batch precision of 2.9-6.3 and 1.4-5.8%, respectively. The between-batch and within-batch accuracy was 95.1-104.1 and 92.4-101.0%, respectively. This validated method is simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

17.
A specific HPLC method for the simultaneous determination of YM928, a novel noncompetitive AMPA receptor antagonist, and its demethylated metabolite (YM-58875) in rat, dog and monkey plasma was developed and validated. The method utilized multiple-step liquid-liquid extraction followed by a reversed-phase HPLC with UV detection at 275 nm. No interfering peaks were observed at the retention times of YM928, YM-58875 or internal standard. The validated quantitation range was 5-5000 ng/mL for both YM928 and YM-58875 when 1 mL of the plasma sample was used. The intra- and inter-day precision was less than 5.3 and 2.5% for YM928, and 3.7 and 2.3% for YM-58875, respectively. The intra- and inter-day accuracies were -8.7-5.3% and 0.7-1.9% for YM928, and -10.0-6.1% and 1.3-3.4% for YM-58875, respectively. The mean recoveries in the extraction process were 52.7-62.8%. The utility of this analytical method was demonstrated by the investigation of the pharmacokinetics of the unchanged drug and its metabolite in preclinical studies.  相似文献   

18.
Salvianolic acid A (SAA), a major effective constituent of Salvia miltiorrhizas, is widely used in traditional Chinese medicine. A sensitive rapid analytical method was established and validated for SAA in rat plasma, which was further applied to assess the pharmacokinetics of SAA in rats receiving a single oral dose of SAA. The method used liquid chromatography tandem mass spectrometry in multiple reaction monitoring mode with chloramphenicol as the internal standard. A simple liquid-liquid extraction based on ethyl acetate was employed. The combination of a simple sample cleanup and short chromatographic run time (3 min) increased the throughput of the method substantially. The method was validated over the range 1.4-1000 ng/mL with a correlation coefficient >0.99. The lower limit of quantification was 1.4 ng/mL for SAA in plasma. Intra- and inter-day accuracies for SAA were 95-113 and 98-107%, and the inter-day precision was less than 12%. This method is more sensitive and faster than previous methods. After a single oral dose of 100 mg/kg of SAA, the mean peak plasma concentration (Cmax) of SAA was 318 ng/mL at 0.5 h, the area under the plasma concentration-time curve (AUC0-12 h) was 698 +/- 129 ng.h/mL, and the elimination half-life (T1/2) was 3.29 h.  相似文献   

19.
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for the quantitative determination of cynandione A in rat plasma and tissues. The plasma samples were pretreated by liquid-liquid extraction with ethyl acetate after the internal standard (honokiol) had been spiked. The tissue samples were homogenized with physiological saline and treated further like the plasma samples. The separation was performed using a Zorbax SB-C(18) column (3.5 microm, 2.1 x 100 mm) and a C18 guard column (5 microm, 4.0 x 2.0 mm) with an isocratic mobile phase consisting of methanol-0.1% formic acid (78:22, v/v) at a flow rate of 0.2 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple-reaction monitoring mode using the electrospray ionization technique in negative mode. The nominal retention times for cynandione A and honokiol were 1.41 and 2.63 min, respectively. The method was validated within the concentration range 0.2-1000 ng/mL in plasma and homogenized tissue for cynandione A, and the calibration curves were linear with correlation coefficients >0.992. The lower limit of quantification of cynandione A was 0.2 ng/mL. The intra-day and inter-day precision and accuracy of the assay in plasma were less than 14.4%, while the intra-day and inter-day precision and accuracy of the assay in tissue homogenate were less than 14.2%. This method proved to be suitable for study of pharmacokinetics and tissue distribution of cynandione A in rat.  相似文献   

20.
Oxycodone (14-hydroxy-7,8-dihydrocodeinone) is a potent opioid receptor agonist. In the present study, a liquid-liquid extraction-based reversed-phase HPLC method with UV detection was validated and applied for the analysis of oxycodone and its major metabolite, noroxycodone, in human plasma. The analytes were separated using a mobile phase, consisting of acetonitrile and phosphate buffer (8:92, v/v) at a flow rate of 1 mL/min, and UV detection at 205 nm. The retention times for oxycodone, noroxycodone and codein (internal standard) were 14.7, 13.8 and 10.2 min, respectively. The validated quantitation range of the method was 2-100 ng/mL for oxycodone and 10-100 ng/mL for noroxycodone. The developed procedure was applied to assess the pharmacokinetics of oxycodone and its metabolite following administration of a single 20 mg oral dose of oxycodone hydrochloride to one healthy male volunteer.  相似文献   