首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Kang HC  Kim HT  Kim SS  Kim C  Yu TJ  Lee SK  Kim CM  Kim IJ  Sung JH  Janulewicz KA  Lee J  Noh do Y 《Optics letters》2012,37(10):1688-1690
We report a coherent diffraction imaging (CDI) using a single 8 ps soft x-ray laser pulse at a wavelength of 13.9 nm. The soft x-ray pulse was generated by a laboratory-scale intense pumping laser providing coherent x-ray pulses up to the level of 10(11) photons/pulse. A spatial resolution below 194 nm was achieved with a single pulse, and it was shown that a resolution below 55 nm is feasible with improved detector capability. The single-pulse CDI might provide a way to investigate dynamics of nanoscale molecules or particles.  相似文献   

2.
We report the first proof-of-principle experiment of iterative phase retrieval from magnetic x-ray diffraction. By using the resonant x-ray excitation process and coherent x-ray scattering, we show that linearly polarized soft x rays can be used to image both the amplitude and the phase of magnetic domain structures. We recovered the magnetic structure of an amorphous terbium-cobalt thin film with a spatial resolution of about 75 nm at the Co L3 edge at 778 eV. In comparison with soft x-ray microscopy images recorded with Fresnel zone plate optics at better than 25 nm spatial resolution, we find qualitative agreement in the observed magnetic structure.  相似文献   

3.
We present an off-axis holography experiment based on the coherent cone beams emitted from a pair of x-ray waveguides. A magnified off-axis hologram is recorded, from which the phase of the optical transmission function of a sample is obtained by digital holographic reconstruction. A spatial resolution of about 100 nm has been achieved at 10.4 keV photon energy. Spatial resolution is determined by the cross-sectional dimensions of the waveguide and could approach a fundamental limit of about 10 nm in future experiments. In addition, we propose a new experimental setup that might overcome this limitation.  相似文献   

4.
The possibility of phase-contrast imaging of nanostructures has been analyzed with the use of a femtosecond-laser plasma as a spatially coherent soft x-ray source and a LiF crystal as an x-ray detector having both the submicron spatial resolution in a wide field of view and a high contrast. It is demonstrated that the spatial coherence length of radiation in the wavelength range 1–13 nm at a distance of 30 cm from the femtosecond-laser plasma source is ?1.5 μm. The achieved spatial coherence of the source is sufficient to obtain high-quality phase-contrast x-ray images of foils with various chemical compositions and a thickness of ?100 nm.  相似文献   

5.
We have imaged a 2D buried Ni nanostructure at 8 nm resolution using coherent x-ray diffraction and the oversampling phasing method. By employing a 3D imaging reconstruction algorithm, for the first time we have experimentally determined the 3D structure of a noncrystalline nanostructured material at 50 nm resolution. The 2D and 3D imaging resolution is currently limited by the exposure time and the computing power, while the ultimate resolution is limited by the x-ray wavelengths. We believe these results pave the way for the development of atomic resolution 3D x-ray diffraction microscopy.  相似文献   

6.
High‐energy X‐ray Bragg coherent diffraction imaging (BCDI) is a well established synchrotron‐based technique used to quantitatively reconstruct the three‐dimensional morphology and strain distribution in nanocrystals. The BCDI technique has become a powerful analytical tool for quantitative investigations of nanocrystals, nanotubes, nanorods and more recently biological systems. BCDI has however typically failed for fine nanocrystals in sub‐100 nm size regimes – a size routinely achievable by chemical synthesis – despite the spatial resolution of the BCDI technique being 20–30 nm. The limitations of this technique arise from the movement of nanocrystals under illumination by the highly coherent beam, which prevents full diffraction data sets from being acquired. A solution is provided here to overcome this problem and extend the size limit of the BCDI technique, through the design of a novel stabilization method by embedding the fine nanocrystals into a silica matrix. Chemically synthesized FePt nanocrystals of maximum dimension 20 nm and AuPd nanocrystals in the size range 60–65 nm were investigated with BCDI measurement at beamline 34‐ID‐C of the APS, Argonne National Laboratory. Novel experimental methodologies to elucidate the presence of strain in fine nanocrystals are a necessary pre‐requisite in order to better understand strain profiles in engineered nanocrystals for novel device development.  相似文献   

7.
We present the first experimental demonstration of lensless diffractive imaging using coherent soft x rays generated by a tabletop soft-x-ray source. A 29 nm high harmonic beam illuminates an object, and the subsequent diffraction is collected on an x-ray CCD camera. High dynamic range diffraction patterns are obtained by taking multiple exposures while blocking small-angle diffraction using beam blocks of varying size. These patterns reconstruct to images with 214 nm resolution. This work demonstrates a practical tabletop lensless microscope that promises to find applications in materials science, nanoscience, and biology.  相似文献   

8.
A spatial resolution of 20 nm is demonstrated at 2.07-nm wavelength by use of a soft x-ray microscope based on Fresnel zone plate lenses and partially coherent illumination. Nanostructural test patterns, formed by sputtered multilayer coatings and transmission electron microscopy thinning techniques, provide clear experimental results.  相似文献   

9.
We report on the temporal and spatial stability of the first tunable femtosecond undulator hard-x-ray source for ultrafast diffraction and absorption experiments. The 2.5-1 Angstrom output radiation is driven by an initial 50 fs laser pulse employing the laser-electron slicing technique. By using x-ray diffraction to probe laser-induced coherent optical phonons in bulk bismuth, we estimate an x-ray pulse duration of 140+/-30 fs FWHM with timing drifts below 30 fs rms measured over 5 days. Optical control of coherent lattice motion is demonstrated.  相似文献   

10.
We report the first demonstration of resonant x-ray diffraction microscopy for element specific imaging of buried structures with a pixel resolution of approximately 15 nm by exploiting the abrupt change in the scattering cross section near electronic resonances. We performed nondestructive and quantitative imaging of buried Bi structures inside a Si crystal by directly phasing coherent x-ray diffraction patterns acquired below and above the Bi M5 edge. We anticipate that resonant x-ray diffraction microscopy will be applied to element and chemical state specific imaging of a broad range of systems including magnetic materials, semiconductors, organic materials, biominerals, and biological specimens.  相似文献   

11.
Time-resolved x-ray diffraction with picosecond temporal resolution is used to probe the product state of a coherent control experiment in which a single acoustic mode in a bulk semiconductor is driven to large amplitude or canceled out. It is demonstrated that by shaping ultrafast acoustic pulses one can coherently control the x-ray diffraction efficiency of a crystal on the time scale of a vibrational period, with application to coherent switching of x-ray beams.  相似文献   

12.
We present a coherent x-ray diffraction study of the antiferrodistortive displacive transition of SrTiO3, a prototypical example of a phase transition for which the critical fluctuations exhibit two length scales and two time scales. From the microbeam x-ray coherent diffraction patterns, we show that the broad (short-length scale) and the narrow (long-length scale) components can be spatially disentangled, due to 100-microm-scale spatial variations of the latter. Moreover, both components exhibit a speckle pattern, which is static on a approximately 10 mn time scale. This gives evidence that the narrow component corresponds to static ordered domains. We interpret the speckles in the broad component as due to a very slow dynamical process, corresponding to the well-known central peak seen in inelastic neutron scattering.  相似文献   

13.
We determine the absolute electron density of a lithographically grown nanostructure with 25 nm resolution by combining hard x-ray Fourier transform holography with iterative phase retrieval methods. While holography immediately reveals an unambiguous image of the object, we deploy in addition iterative phase retrieval algorithms for pushing the resolution close to the diffraction limit. The use of hard (8 keV) x rays eliminates practically all constraints on sample environment and enables a destruction-free investigation of relatively thick or buried samples, making holographic diffraction imaging a very attractive tool for materials science. We note that the technique is ideally suited for subpicosecond imaging that will become possible with the emerging hard x-ray free-electron lasers.  相似文献   

14.
Resolution of 90 nm was achieved with a research microscope simply by replacing the standard bright-field condenser with a homebuilt illumination system with a cardioid annular condenser. Diffraction gratings with 100 nm width lines as well as less than 100 nm size features of different-shaped objects were clearly visible on a calibrated microscope test slide. The resolution increase results from a known narrower diffraction pattern in coherent illumination for the annular aperture compared with the circular aperture. This explanation is supported by an excellent accord of calculated and measured diffraction patterns for a 50 nm radius disk.  相似文献   

15.

An equidistant (in the wavenumber) spectrometer based on a diffraction grating, a compensation prism, and a CCD linear array is developed and implemented for spectral-domain optical coherence tomography. A criterion is introduced for estimating the level of residual nonequidistance. This criterion allows one to determine the threshold compensation level necessary for obtaining the spectrally limited spatial resolution. The method is tested in spectral-domain optical coherent tomography systems at wavelengths of 1270 and 830 nm.

  相似文献   

16.
相干X射线衍射成像方法是一种先进的成像技术,分辨率可达纳米量级.国际上大多数的同步辐射装置和自由电子激光装置都建立了该成像方法,并有将其作为主要成像技术的趋势.上海光源作为目前国内唯一的一台第三代同步辐射光源,尚未建立基于硬X射线的相干衍射成像实验平台.随着一批以波荡器为光源的光束线站投入使用,使得该方法的建立成为了可能.本文基于上海光源BL19U2生物小角散射线站,通过有效的光路设计,搭建了相干衍射实验平台,在12 keV和13.5 keV能量点均获得了硬X射线相干光束,并基于小孔衍射测量了入射光束的空间相干长度.该平台支持常规和扫描相干衍射实验模式,对小孔衍射图样及波带片扫描衍射图样实现了正确的相位重建,证明了该平台初步具备开展硬X射线相干衍射成像实验的能力.硬X射线相干衍射成像实验平台为国内首次建立,将为国内该实验方法的发展和应用提供有效的软硬件支持.  相似文献   

17.
廖欣  何宁  陈明  陈名松 《光学学报》2008,28(s2):278-282
为使现代电子侦察技术能适应信号密集、宽频谱、大动态的电磁环境, 提出了一种基于声光偏转器实现相关光信号处理的方法, 分析了射频信号频率变化与布拉格衍射角的关系, 讨论了声光偏转效应对信号频率的空间滤波特性; 在理论分析的基础上, 构建了在可见光范围内实现声光偏转的相干光信号探测的实验系统, 并通过计算机仿真对比, 验证了这种方法的可行性。实验表明, 采用波长为630 nm的单频激光, 带宽为200 MHz的声光偏转器, 其频率分辨率优于1 MHz, 频率信号的空间分离效果明显, 接收灵敏度和信噪比得到改善。  相似文献   

18.
We used an approach based on the self-imaging property of gratings to fabricate high-resolution Fresnel zone plates (FZPs). Under certain conditions, the illumination of a parent ZP with a wideband EUV beam produces a radially oscillating intensity distribution with double the spatial frequency of the ZP. This intensity distribution is observed in a certain distance range, given by the local zone width, the focal length of the ZP, and the spectral bandwidth of the illuminating beam. This phenomenon has been used to lithographically record daughter ZPs that have approximately half the zone width, thus twice the resolution, of the parent ZP. FZPs with zone widths as low as 30 nm have been fabricated in this way. Use of this technique in the extreme ultraviolet (EUV) region has the potential for high throughput production of FZPs and similar high-resolution diffraction optics with variable spatial frequency for the EUV and x-ray regions.  相似文献   

19.
Received26Jan.1995;Revisedmanuscriptreceived18Apr.1995ResolutioninX-rayHolography¥ZHUPeiping;XIAOTiqiao;CHENJianwen;XUZhizhan...  相似文献   

20.
Stable, low noise, infrared squeezed state tight at 1064 nm is generated by utilizing optical parametric down-conversion (OPDC) technique based on periodically poled KTiOPO4 in a optical parametric amplifier (OPA) resonator. A non-classical noise reduction of 2.58 dB below the shot noise is observed through balanced homodyne detection. The squeezed state light is used to set up an imaging system for high-resolution imaging, and it is found that the resolution of image based on the amplitude-squeezed light is 1.26 times larger than that of infrared coherent light under the same intensity. The experimental results indicate that squeezed light is an important non-classical light, which can overcome the coherent laser shot-noise, the classical diffraction limit and limit of quantum noise.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号