首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The efficiency of ion chromatography columns packed with styrene-divinylbenzene copolymer containing quaternary ammonium groups to preconcentrate triazine herbicides and their degradation products below μg/l levels has been established. Retention is studied for different types of water. Pure methanol was used in a one-step elution. Enrichment factors of at least 4000 are achieved. Determination was carried out by using gas chromatography-single-ion monitoring mass spectrometry. Recoveries for run-off agricultural water were between 67–100% and close to 100% for ground water. The maximum admissible concentration ion drinking water (0.1 μg/l) and the alert and alarm threshold values in surface water (1 and 3 μg/l, respectively) dictated by the European Union can be measured.  相似文献   

2.
An on-line combination of gel permeation chromatography and gas chromatography has been designed using either a laboratory-built or a commercially available LC-GC apparatus to determine organophosphorus pesticides in olive oil. Gel permeation chromatography was used for sample pretreatment, viz. to separate the low-molecular-mass pesticides from the higher-molecular-mass fat constituents of the oil. A mixture of n-decane and the azeotropic mixture of ethyl acetate and cyclohexane was found to give an adequate separation between the fat and the organophosphorus pesticides. The pesticide-containing fraction, monitored by a UV detector, was transferred on-line to the gas chromatograph using a loop-type interface. n-Decane (6%, v/v) was added to the eluent in order to widen the application range of the transfer technique towards more volatile pesticides. After solvent evaporation through the solvent vapour exit and subsequent GC separation, the compounds were selectively detected with a thermionic or a flame photometric detector. The set-up allowed the direct analysis of oil samples after dilution in the gel permeation chromatography eluent without further sample clean-up. Detection limits were about 5 and 10 μg/kg with the thermionic and the flame photometric detector, respectively, when using an injection volume of only 30 μl of the 20-fold diluted oil. The total procedure was linear in the 0.01–10 mg/kg range for both detectors. For twenty organophosphorus pesticides, the relative standard deviations were 3–13% at the 20–60 μg/kg level.  相似文献   

3.
The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 1 samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (>2 1 for all test analytes), reproducibility (R.S.D. of recoveries, 4–8%, n=3) and smapling speed (100 ml/min); detection limits in drinking water were 0.05–0.16 μg/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10×2.0 mm I.D. precolumn, were tested, and 50–200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1–0.3 min and R.S.D. of peak heights 4–14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05–1 μg/l in surface water.  相似文献   

4.
This study describes an SPE coupled with large volume injection (LVI) analytical method for the analysis of organochlorine pesticides, BHC (alpha, beta, delta), aldrin, endosulfan (alpha, beta), endrin, dieldrin, and DDT, from aqueous samples. Determination was carried out by GC with MS. The LODs of organochlorine pesticides were determined at 10 ng/L concentration levels, and the results show that SPE-LVI-GC/MS has the potential to accurately determine organochlorine pesticides in water, as it avoids analyte classes in the various steps of a typical extraction procedure.  相似文献   

5.
Pesticide analysis by micellar electrokinetic capillary chromatography   总被引:2,自引:0,他引:2  
On-capillary sample concentration using sample stacking for the improvement of detection limits for various pesticides separated by micellar electrokinetic capillary chromatography was examined. The dependence of the stacking on different parameters was investigated. An approximately 30-fold preconcentration was achieved by applying sample stacking. Employing a two-step enrichment process (solid-phase extraction combined with sample stacking), detection limits were improved and the sample volume for SPE was reduced. In addition, the total time for the analysis was considerably reduced. Detection limits were between 0.01 and 0.1 ng/ml under these enrichment conditions.  相似文献   

6.
A new analytical method has been developed for sample preconcentration and analysis of phenolic compounds in sherry wine using on-line solid-phase extraction(SPE)-HPLC-diode array detection. The samples of wine were injected and adsorbed onto polystyrene divinylbenzene cartridges; a robotic semiflexible system was used to automate the SPE stage. Chromatographic separation was carried out in a Symmetry C18 steel cartridge, with a two-step elution gradient. Peaks were identified by comparing their UV spectra with the library of spectra compiled by the authors.  相似文献   

7.
An automated high-capacity sorption device for GC analysis of ultra trace components has been developed. The scope of the presented technique was to combine the simplicity of solid-phase microextraction (SPME) with the high extraction efficiency of the stir bar sorptive extraction technology. Sorptive extractions of water samples were performed using polydimethylsiloxane (PDMS) rubber tubing (120 microl) mounted onto a glass rod. The sampling procedure was carried out by a robotic autoinjector. Since the setup is fully automated, unattended and precise time-controlled extraction of samples is possible and makes quantitation with non-equilibrium extractions feasible. The sorption probes are easy to exchange, which facilitates off-line/in-field sampling. The system was evaluated with a test mixture of 44 environmentally hazardous compounds. Detection limits were found to be in the sub-ppt region. The performance of the system was demonstrated with the analysis of polycyclic aromatic hydrocarbons in urban snow.  相似文献   

8.
A multiresidue solid phase extraction-gas chromatography (SPE-GC) method is developed for the analysis of 28 organochlorine (OCPs), organophosphorus (OPPs) and organonitrogen (ONPs) pesticides at ng l− 1 levels in washing water from olive processing. Pesticides are separated from the water matrix, containing estimable amounts of olive oil, by eluting them from a C18 SPE cartridge using dichloromethane. The target compounds are determined in the final extract by gas chromatography using thermionic specific (TSD) and electron capture (ECD) detection. Recoveries range from 79% to 129% in spiked washing water samples and detection limits are between 1 and 4 ng l− 1. The method was successfully applied to determine OCPs, OPPs and ONPs in 25 samples of water collected directly in the inlet and outlet of the washing devices of three olive mills at different locations in Jaén (Spain). The most frequently encountered pesticide residues were terbuthylazine, simazine and diuron. In some of the water samples coming from the inlet of the washing devices, terbuthylazine and diuron measured concentrations were above the concentration limits scheduled by law.  相似文献   

9.
Summary On-line solid-phase extraction-gas chromatographyion-trap tandem mass spectrometry (SPE-GC-MS/MS) has been used for the trace-level determination of polar and apolar pesticides. The SPE-GC interface, an Autoloop 2000, was operated at an injection temperature of 90°C which permitted the determination of thermolabile pesticides such as carbofuran and carbaryl. Rectilinear calibration curves were obtained for the analytes tested over a range of 0.1–500 ng L−1, using a sample volume of 10–100 mL for enrichment on an SPE cartridge packed with styrene-divinylbenzene copolymer. The detection limits for the pesticides were in the 0.01–4 ng L−1 range. For a number of pesticides acceptable tandem mass spectra were obtained at levels as low as 0.1 ng L−1 level in real-life water samples. As a demonstration of the applicability of this technique for inorganic anions, bromide and nitrite were converted into 4-bromoacetanilide and 2-phenylphenol, respectively. The reaction products were pooled and subjected to simultaneous analysis by the present method using full-scan mass spectrometric detection. The detection limits were 0.3 and 2 ng L−1, respectively.  相似文献   

10.
The applicability of headspace solid-phase microextraction (HS-SPME) to pesticide determination in water samples was demonstrated by evaluating the effects of temperature on the extraction of the pesticides. The evaluations were performed using an automated system with a heating module. The 174 pesticides that are detectable with gas chromatograph were selected objectively and impartially based on their physical properties: vapor pressure and partition coefficient between octanol and water. Of the 174 pesticides, 158 (90% of tested) were extracted with a polyacrylate-coated fiber between 30 and 100 degrees C and were determined with gas chromatograph-mass spectrometry. The extraction-temperature profiles of the 158 extracted pesticides were obtained to evaluate the effects of temperature on the extraction of pesticides. The pesticides were classified into four groups according to the shape of their extraction-temperature profiles. The line of demarcation between extractable pesticides and non-extractable pesticides could be drawn in the physical property diagram (a double logarithmic plot of their vapor pressure and partition coefficient between octanol and water). The plot also revealed relationships between classified extraction features and their physical properties. The new method for multi residue screening in which the analytes were categorized into sub-groups based on extraction temperature was developed. In order to evaluate the quantitivity of the developed method, the 45 pesticides were chosen among the pesticides that are typically monitored in waters. Linear response data for 40 of the 45 was obtained in the concentration range below 5 microg/l with correlation coefficients ranging between 0.979 and 0.999. The other five pesticides had poor responses. Relative standard deviations at the concentration of the lowest standard solution for each calibration curve of the pesticides ranged from 3.6 to 18%. The value of 0.01 microg/l in the limits of detection for 17 pesticides was achieved only under the approximate conditions for screening, not under the individually optimized conditions for each pesticide. Recoveries of tested pesticides in actual matrices were essentially in agreement with those obtained by solid-phase extraction.  相似文献   

11.
12.
The ecdysteroids are hormones widely distributed in insects and crustaceans, where they are involved in the regulation of moulting. Methods of sample preparation based on solid-phase extraction of the ecdysteroids from biological samples for subsequent chromatographic analysis are reviewed. Most methods use an initial partition of the sample (or extract) between water or aqueous methanol with a non-polar solvent to remove lipids. The aqueous portion is applied to a cartridge containing C18-bonded silica gel. Removal of polar impurities is then effected, followed by recovery of the ecdysteroids from the cartridge and chromatographic analysis. Results are given for the use of phenylboronic acid (PBA) bonded to silica gel as a means of obtaining a much more specific method of extraction. The PBA phase was shown to have a high affinity for ecdysteroids containing a 20,22-cis-diol but not for compounds possessing only a 2,3-cis-diol.  相似文献   

13.
A dispersive solid-phase microextraction (dispersive-SPME) method for the determination of tetracycline, oxytetracycline, chlortetracycline and doxycycline is proposed. Different silica-based and polymeric sorbents were evaluated for their capacity to simultaneously preconcentrate tetracyclines (TCs) in the dispersive format from aqueous or organic solutions. Silica-based sorbents especially functionalized with primary amine, secondary amine, or carbonyl groups have showed higher capacity than polymeric sorbents under organic environment. In the proposed dispersive solid-phase microextraction method, after extraction with acetonitrile and salt-promoted partitioning, TCs were adsorbed to a small amount of dispersive silica-based primary and secondary amine sorbents, desorbed with a small volume of desorption solution, and determined by high-performance liquid chromatography with diode-array detection. Under the optimal conditions, recoveries were determined for surface water and milk samples spiked at 10 ng/mL and 50–150 ng/g, respectively, and quantification was achieved by matrix-matched calibration. The calibration curves of four TCs in both samples showed linearity with a correlation coefficient value above 0.997. Average recoveries ranged from 97.1 to 104.1% and the precision was from 2.0 to 5.6%. Limits of detection ranged from 0.7 to 3.5 ng/mL and from 7.9 to 35.3 ng/g for four TCs surface in surface water and milk samples, respectively.  相似文献   

14.
A coupled technique, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), was investigated for one-step in situ sample pretreatment for organochlorine pesticides (OCPs) prior to gas chromatographic determination. The OCPs, aldrin, o,p'-DDE, p,p'-DDE, o,p'-DDT, p,p'-DDT, dieldrin, alpha-endosulfan, beta-endosulfan, endosulfan sulfate, endrin, delta-HCH, gamma-HCH, heptachlor, heptachlor epoxide, methoxychlor and trifluralin were collected by the proposed method and analyzed by gas chromatography with electron-capture detection (GC-ECD). To perform the MA-HS-SPME, six types of SPME fibers were examined and compared. The parameters affecting the efficiency in MA-HS-SPME process such as sampling time and temperature, microwave irradiation power, desorption temperature and time were studied to obtain the optimal conditions. The method was developed using spiked water samples such as field water and with 0.05% humic acid in a concentration range of 0.05-2.5 microg/l except endosulfan sulfate in 0.25-2.5 microg/l. The detection was linear over the studied concentration range with r2>0.9978. The detection limits varied from 0.002 to 0.070 microg/l based on S/N=3 and the relative standard deviations for repeatability were <15%. A certified reference sample of OCPs in aqueous solution was analyzed by the proposed method and compared with the conventional liquid-liquid extraction procedure. These results are in good agreement. The results indicate that the proposed method provides a very simple, fast, and solvent-free procedure to achieve sample pretreatment prior to the trace-level screening determination of organochloride pesticides by gas chromatography.  相似文献   

15.
A liquid‐phase microextraction coupled with LC method has been developed for the determination of organophosphorus pesticides (methidation, quinalphos and profenofos) in drinking water samples. In this method, a small amount (3 μL) of isooctane as the acceptor phase was introduced continually to fill‐up the channel of a 1.5 cm polypropylene hollow fiber using a microsyringe while the hollow fiber was immersed in an aqueous donor solution. A portion of the acceptor phase (ca. 0.4 μL) was first introduced into the hollow fiber and additional amounts (ca. 0.2 μL) of the acceptor phase were introduced to replenish at intervals of 3 min until set end of extraction (40 min). After extraction, the acceptor phase was withdrawn and transferred into a 2 mL vial for a drying step prior to injection into a LC system. Parameters that affect the extraction efficiency were studied including the organic solvent, length of fiber, volume of acceptor and donor phase, stirring rate, extraction time, and effect of salting out. The proposed method provided good enrichment factors of up to 189.50, with RSD ranging from 0.10 to 0.29%, analyte recoveries of over 79.80% and good linearity ranging from 10.0 to 1.25 mg/L. The LOD ranged from 2.86 to 82.66 μg/L. This method was applied successfully to the determination of organophosphorus pesticides in selected drinking water samples.  相似文献   

16.
Summary A method has been developed for determination of twenty-four polar pesticides—nine organophosphorus pesticides, thirteen organonitrogen compounds, and two triazine degradation products—in surface water. It entails extraction of the target pesticides from 1-L water samples by solid-phase extraction (SPE), then gas chromatography (GC) with large-volume (40 μL) injection. Filtered surface water, from the St Lawrence River in Canada and the River Loire and its tributaries in France, was extracted on cartridges filled with 500 mg Carbopack B (120–400 mesh). Analysis was performed by gas chromatography with a thermionic specific detector (GC-TSD) and a mass spectrometric (MS) detector. Overall percentage recoveries were satisfactory (>70%) for all target pesticides, with precision below 10%. Detection limits were between 0.5 and 4 ng L−1.  相似文献   

17.
Capillary electrophoresis-mass spectrometry (CE-MS) with an electrospray ionization interface was applied for the quantitative analysis of imazamox pesticide in well water, potable water, and pond water. The detector response for imazamox was determined to be linear over the concentration range of 50-1 ng/ml. The limits of quantitation and detection of the method were determined to be 200 and 20 ng/l for imazamox compound in each type of water sample, respectively. The total sample preparation and CE-MS analysis time was under 2 h.  相似文献   

18.
An integrated system has been developed which combines liquid (LC) and gas (GC) chromatographic separation with a single mass spectrometer (MS). On-line solid-phase extraction (SPE) of 10–200 ml aqueous samples on a short (10 × 2.0 mm I.D.) precolumn packed with a styrene-divinylbenzene copolymer is used for analyte enrichment. The trace-enrichment procedure was automated by means of a PROSPEKT cartridge-exchange/solvent-selection/valve-switching unit. After sample loading, the precolumn is eluted on-line in two subsequent runs, first onto the GC-MS system and, next, onto the LC-MS system using a particle beam (PB) interface. Prior to entering the PB-MS, the LC eluent passes through the flow cell of a UV diode-array detector (DAD). Both GC-MS and LC-PB-MS generate classical electron ionisation (EI) and chemical ionisation (CI) spectra which are useful for the identification of low- and sub-μg/l concentrations of environmental pollutants covering a wide polarity and volatility range. The LC-DAD data provide additional means for quantitation and yield complementary spectral information. All three detection systems (GC-MS, LC-DAD, LC-PB-MS) and the trace-enrichment procedure are fully automated and controlled from the keyboard of the central computer. With such a ‘MULTIANALYSIS’ system GC-MS, LC-DAD and LC-MS data of the same sample can be obtained within 3 h. The system was optimised with nine chlorinated pesticides in drinking water as test mixture. With 100-ml samples detection limits in GC-MS were 0.0005−0.03 μg/l, and in LC-PB-MS 0.5–7 μg/l, both in the full-scan (EI) mode. Negative chemical ionisation (NCI) with methane as reagent gas improved the sensitivity of six halogenated compounds 3- to 30-fold and provided relevant information for structural elucidation of unknown compounds in real-world samples. LC-DAD detection limits varied from 0.01 to 0.05 μg/l. Relative standard deviations (R.S.D.) of retention times were less than 0.2% in all systems, R.S.D.s of peak areas were 5–15% for GC-MS and LC-PB-MS and less than 5% for LC-DAD. The ‘MULTIANALYSIS’ system was used to analyse surface water samples and river sediment extracts; several pollutants were detected and identified.  相似文献   

19.
For the first time a dispersive liquid–liquid microextraction method on the basis of an extraction solvent lighter than water was presented in this study. Three organophosphorus pesticides (OPPs) were selected as model compounds and the proposed method was carried out for their preconcentration from water samples. In this extraction method, a mixture of cyclohexane (extraction solvent) and acetone (disperser) is rapidly injected into the aqueous sample in a special vessel (see experimental section) by syringe. Thereby, a cloudy solution is formed. In this step, the OPPs are extracted into the fine droplets of cyclohexane dispersed into aqueous phase. After centrifuging the fine droplets of cyclohexane are collected on the upper of the extraction vessel. The upper phase (0.40 μL) is injected into the gas chromatograph (GC) for separation. Analytes were detected by a flame ionization detector (FID) (for high concentrations) or MS (for low concentrations). Some important parameters, such as the kind of extraction and dispersive solvents and volume of them, extraction time, temperature, and salt amount were investigated. Under the optimum conditions, the enrichment factors (EFs) ranged from 100 to 150 and extraction recoveries varied between 68 and 105%, both of which are relatively high over those of published methods. The linear ranges were wide (10–100 000 μg/L for GC‐FID and 0.01–1 μg/L for GC‐MS) and LODs were low (3–4 μg/L for GC‐FID and 0.003 μg/L for GC‐MS). The RSDs for 100.0 μg/L of each OPP in water were in the range of 5.3–7.8% (n = 5).  相似文献   

20.
Temperature programmable (PTV) injectors with packed widebore (ca. 3.5 mm i.d.) liners are used for large volume injection in capillary gas chromatography with the aim to simplify and/or improve off-line sample pretreatment proecdures. A simple procedure for optimization of large volume PTV injection is described. The system performance, i.e. linearity and repeatability, is evaluated for polar nitrogen/phosphorus containing pesticides (PTV-GC-NPD) and organochlorine pesticides (PTV-GC-ECD) in river water extracts as well as for polycyclic aromatic hydrocarbons (PAHs) in river sediment (PTV-GC-MS).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号