首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 1 samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (>2 1 for all test analytes), reproducibility (R.S.D. of recoveries, 4–8%, n=3) and smapling speed (100 ml/min); detection limits in drinking water were 0.05–0.16 μg/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10×2.0 mm I.D. precolumn, were tested, and 50–200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1–0.3 min and R.S.D. of peak heights 4–14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05–1 μg/l in surface water.  相似文献   

2.
Nicotine was selected as the target molecule for monitoring of the smoking process by multicommutation Fourier Transform Infrared spectroscopy (FTIR). The method involved the use of CHCl3 for on-line extraction of nicotine from tobacco, cigarette filters and tobacco ash from NH4OH alkalinized samples, and absorbance measurement of the characteristic band at 1316 cm−1 in the stopped-flow mode, by obtaining the peak area in the range between 1334 and 1300 cm−1. Under the best operational conditions, the procedure developed provided a detection limit of 0.05 mg mL−1 nicotine, corresponding to 0.5 mg g−1 in the solid sample, a relative standard deviation less than 2.5%, and a sampling frequency of 12 determinations h−1. It can be concluded that nicotine migrates in the smoke mainstream towards the filter during the smoking process. The smoking of cigarettes and cigars is different. Nicotine is retained weakly by both tobacco and filter in the case of cigarettes, and strongly by the unburned tobacco in cigars. The incomplete smoking of cigars and cigarettes reduces nicotine intake and thus reduces the additive effect.  相似文献   

3.
A method has been developed for Fourier transform infrared (FTIR) spectroscopy determination of Propamocarb in emulsifiable pesticide concentrate formulations. Five microliter sample was directly injected without any pretreatment in a CHCl3 stream at 2 mL min(-1) into a closed system and the FTIR spectra of sample and standard solutions were obtained using a nominal resolution of 4 cm(-1) from 4000 to 900 cm(-1) spectral region and accumulating 2 scans per spectrum. Propamocarb determination was based on the measurement of flow injection analysis (FIA) recording height established from FTIR peak area measurements from 1713 to 1703 cm(-1) corrected using a baseline defined at 2000 cm(-1). The concentration of Propamocarb in samples was calculated by interpolation in an external calibration line obtained from several injections of 2 microL of a 47% (w/v) standard solution into the CHCl3 closed system. This procedure provided a limit of detection of 0.8% (w/v) in the original sample, a sensitivity of 0.3190 absorbance units mL mg(-1) for a path length of 0.11 mm and a relative standard deviation of 0.2% for five independent measurements at 0.74 mg mL(-1) concentration level. The maximum sampling frequency of the whole procedure was 34 h(-1) and the waste generation was reduced to only 2 mL of CHCl3 solution per sample and additional 2 mL for the whole calibration line.  相似文献   

4.
A sustainable and environmentally friendly procedure has been developed for the FTIR determination of caffeine in tea leaf samples. The method is based on the extraction with ammonia and CHCl3 and direct determination of caffeine on the chloroform extracts using peak height absorbance measurements at 1658.5 cm(-1) and external calibration. The method provides a sensitivity of 0.2142 absorbance units mg(-1) mL and a limit of detection of 1 mg L(-1), corresponding to 0.002% m/m caffeine in tea leaves. As compared with a reference procedure, based on UV absorbance measurement at 276 nm after low pressure column chromatography, the developed procedure reduces the consume of CHCl3 by a factor of 10, that of NH4OH by a factor of 20 and avoids the use of diethyl ether and Celite. The time required to do the analysis of a sample is 15 minutes as compared with the 6 hours for the reference one.  相似文献   

5.
A new procedure has been developed for the FT-IR determination of caffeine in roasted coffee samples. The method involves wetting the coffee samples with a 0.25 M aqueous NH3 solution, extracting the caffeine with CHCl3, and measuring absorbance at 1,659 cm(-1) using a baseline established between 1,900 and 830 cm(-1). The procedure proposed is fast, only requiring a total extraction time of 16 min for each sample, and provides a drastic reduction of the organic solvent consumed, from the 200 mL diethyl ether and 50 mL CHCl3, required for each sample by the reference chromatographic UV-spectrometric determination to only 5 mL CHCl3. The method provides a limit of detection of the order of 3 mg L(-1) caffeine and a relative standard deviation of 0.4% for 3 independent analyses of a sample containing 18.6%mg/g caffeine. The accuracy of the FT-IR procedure was evaluated from recovery experiments on spiked samples providing values from 94.4 to 100.1% and from the comparison of results found for a series of commercial samples, by both FT-IR and the official reference procedure.  相似文献   

6.
Polycations as displacer in high-performance bioseparation   总被引:2,自引:0,他引:2  
Non-aqueous capillary electrophoresis with electrochemical detection (NACE-ED) was applied to the determination of nicotine. The measurements were performed using an acetonitrile-based buffer. Nicotine was shown to yield well defined voltammetric signals suitable for oxidative detection. The precision of NACE-ED regarding migration time and peak height for samples containing 8 micrograms/ml nicotine is expressed by relative standard deviations of 0.1% and 1.6%, respectively (n = 8). The limit of detection for nicotine was 13 ng/ml (286 fg). For nicotine determination in tobacco samples various solutions were studied regarding the extraction efficiency in an ultrasonic bath. The highest extraction efficiency was obtained using a solvent mixture consisting of acetonitrile-acetic acid-water (20:5:75, v/v). The results for nicotine determination in tobacco were evaluated using tobacco reference material with certified nicotine content. Analytical aspects such as accuracy, reproducibility and selectivity were addressed in this work. The measurements were based on the use of a newly developed electrochemical detector cell which was found to enable user-friendly operation of NACE-ED measurements.  相似文献   

7.
Wang H  Zhao Q  Song W  Xu Y  Zhang X  Zeng Q  Chen H  Ding L  Ren N 《Talanta》2011,85(1):743-748
A simple and low-cost high-throughput dynamic microwave-assisted extraction (HTDMAE) device was firstly assembled and validated by the extraction of nicotine in mushroom samples. In this device, a household microwave oven was applied to provide the microwave energy; a vacuum pump was used to deliver the solvent. Compared with traditional dynamic microwave-assisted extraction method, the sample throughput and microwave energy utilization were improved by the HTDMAE, up to 20 samples could be treated simultaneously in 9 min. Taking extraction of nicotine in mushroom sample as an example, a method was established with extraction, separation and enrichment of nicotine in a single step by the device on-line coupled with solid-phase extraction (SPE). Nicotine was first extracted from the mushroom samples with water under the action of microwave energy, and then directly introduced into the SPE column which was packed with cation-exchange resins. Subsequently, the nicotine trapped on the resins was eluted with methanol-ammonia (95:5, v/v) and determined by high-performance liquid chromatography. The limit of detection of nicotine obtained is 5.6 μg kg(-1) in fresh mushroom sample. The recovery of nicotine in mushroom samples is in the range of 87.4-104.0%. The proposed method which significantly reduced the overall analysis time and increased sample throughput should be favored for routine analyse of complex solid sample.  相似文献   

8.
Quantitation of nicotine in tobacco products by capillary electrophoresis   总被引:3,自引:0,他引:3  
A simple and rapid capillary electrophoresis (CE) method was developed for the quantitation of nicotine in commercial tobacco products. The method involves a 6 min run at 30 kV, using a 50 mM phosphate buffer (pH 2.5), paraquat as internal standard, and UV detection at 260 nm. Nicotine was extracted from tobacco products in <15 min. Recoveries from spiked extracts were >95%, and the extraction efficiencies of water, 1 M HCI, 1 M acetic acid, 5 mM phosphate buffer (pH 2.5), and 1% triethanol amine were similar. Nicotine concentrations in 67 samples of cigarettes, cigars, and bidis varied between 0.37 and 2.96% (w/w). An established gas chromatography/mass spectrometry method using toluene extraction consistently yielded lower nicotine values than the CE method. Experimental evidence suggests that this is due to insufficient extraction of nicotine by toluene.  相似文献   

9.
Molecularly imprinted polymers (MIPs) are synthetic polymers designed to selectively extract target analytes from complex matrices (including biological matrices). The literature shows that MIPs have a degree of cross-selectivity from analytes within the same class of compounds. A commercially available MIP for tobacco-specific nitrosamines (TSNAs) is designed to be class selective for four TSNA compounds. This study sought to characterize the extent of cross-selectivity of the TSNA MIPs with other tobacco alkaloids. Cross-selectivity and recovery of the SupelMIP™ TSNA SPE cartridges was assessed with N-nitrosonornicotine (NNN), nicotine, cotinine and morphine. Their recoveries were compared with the recoveries of a nonimprinted polymer SPE cartridge, and two traditional SPE cartridges: a Waters mixed-mode cation exchange cartridge and a Waters hydrophilic–lipophilic balance cartridge. NNN and cotinine had the highest recoveries with the MIP cartridge, over 80%, and cotinine samples in urine had >80% recoveries. Nicotine had highly variable recoveries, possibly owing to differing chemical properties from the TSNAs. All three analytes had significantly different recoveries with the MIP cartridges compared with the traditional SPE cartridges. Morphine displayed nonspecific interactions with the MIP cartridges. Utilization of the TSNAs’ cross-selectivity allows for simultaneous extraction and identification of multiple tobacco biomarkers using one extraction technique.  相似文献   

10.
A new isolation and separation method has been developed for the alkaloid-related nitrosamines in tobacco, called tobacco-specific nitrosamines (TSNA). The improved isolation procedure involves the extraction by sonication of TSNA from cured tobacco with toluene and an aqueous citrate buffer solution, while purification is achieved by solid phase extraction on small silica cartridges. Interfering extract materials are eluted from the silica cartridges with the toluene and a chloroform-methylene chloride solvent, while subsequent elution with chloroform yields the TSNA in a purified fraction. Gas chromatographic analyses on an SE-54-coated glass capillary column and detection by a nitrogen-phosphorous detector produce very good data on the four TSNAs, which include N-nitrosanatabine (NATB), N-nitrosoanabasine (NAB), 4-(N-methyl-N-nitrosamino)-1-(3-pyridyl)-1-butanone (called NNK), and N-nitrosonornicotine (NNN). The method is shown to be quantitative, reproducible, and applicable to the determination of TSNA in various tobacco samples, such as stems and lamina of cured tobacco leaves, as well as to smokeless tobacco.  相似文献   

11.
A new method for N,N'-ethylenebisstearamide (EBS) analysis was developed and validated in normal phase-HP liquid chromatography (NP-HPLC) with diol column at 50 degrees C with 100% CHCl(3) at 1 mL min(-1) and evaporative light scattering detection with elution time at 3.0 min. EBS solubility was the best at 0.80 gL(-1) in CHCl(3)/methanol 90:10. The molecular structure of commercial samples of EBS was determined by GC-MS which ascertained that the main structure is C18/C18 at approximately 45%. The remaining part was constituted by molecules with different alkyl chain length. The HPLC quantification method was proved linear (r=0.9983), accurate (99.6%) and precise (1.95%). Limit of quantification (LOQ) and limit of detection (LOD) were equal to 2.0 and 0.8 microg mL(-1), respectively. The suitability of this method was assessed with a dissolution/precipitation extraction procedure of EBS from ethylene vinyl acetate (EVA) polymer which showed that other additives and polymer do not interfere with EBS analysis. The intra-day and day-to-day precisions of extraction method were equal to 9.1% and 9.9%, respectively.  相似文献   

12.
In this study, a new procedure, based on on-line solid-phase extraction (SPE) and analysis by liquid-chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), has been developed for the simultaneous, multianalyte determination of 21 selected pesticides, phenols and phthalates in water. SPE was carried out on polymeric PLRP-s cartridges by percolating 20 mL-samples. For sample preconcentration, the performance of a prototype programmable field extraction system (PROFEXS) was evaluated against the commercial laboratory bench Prospekt system used for method development. The Profexs is designed for the automated on-site sampling, SPE preconcentration, and storage of up to 16 samples in SPE cartridges. These cartridges are further eluted and on-line analyzed with the Prospekt coupled to the chromatographic system. In the optimized method, where completely on-line SPE-LC-MS analysis of the samples is carried out with the Prospekt in the laboratory, detection limits lower than 100 ng/L, and satisfactory precision (relative standard deviations <25%) and accuracies (recovery percentages >75%) were obtained for most investigated compounds from the analysis of spiked Milli-Q water. The extraction efficiency achieved with the Profexs was comparable to that of the Prospekt for most compounds and somewhat lower for the most apolar analytes, probably due to adsorption on the pump filters. The completely on-line optimized method was applied to the analysis of surface water, ground water and drinking water from a waterworks in Barcelona. Some pesticides and phenols were found in both surface water and groundwater at ng/L or µg/L levels, but not in the final drinking water. Di(2-ethylhexyl)phthalate (DEHP) was present in all samples investigated, including blanks. To the author's knowledge, this is the first work describing the application of a fully automated on-line SPE-LC-MS method for the simultaneous analysis of pesticides, phenols, and phthalates in water, and the second one that examines the possibilities of the prototype Profexs for automated on-site SPE preconcentration of organic pollutants from water samples.  相似文献   

13.
A simple and rapid analytical method for the determination of nonylphenol (NP) and nonylphenol ethoxylates (NPEOx) in solid environmental samples has been developed. This method combines an ultrasonic-assisted extraction procedure in small columns and an enrichment step onto C(18) solid-phase extraction cartridges prior to separation using HPLC with fluorescence detection. Method optimization was carried out using soil samples fortified at different concentration levels (from 0.1 to 100 microg/g). Under optimum conditions, 2g of soil was placed in small glass columns and extraction was performed assisted by sonication (SAESC) at 45 degrees C in two consecutive steps of 15 min using a mixture of H(2)O/MeOH (30/70). The obtained extracts were collected, loaded onto 500 mg C(18) cartridges, and analytes were eluted with 3 x 1 ml of methanol and 1 ml of acetonitrile. Finally, sample extracts were evaporated under a nitrogen stream, redissolved in 500 microl H(2)O/AcN (50/50), and passed though a 0.45 microm nylon filter before final determination by HPLC-FL. The developed procedure allowed to achieve quantitative recoveries for NP and NPEOx, and was properly validated. Finally, the method was applied to the determination of these compounds in soils and other environmental solid samples such as sediments, compost and sludge.  相似文献   

14.
An automated method based on the on-line coupling of anion-exchange solid-phase extraction (SPE) and cation-exchange liquid chromatography followed by post-column derivatization and fluorescence detection has been developed for the trace level determination of glyphosate and its primary conversion product aminomethyl phosphonic acid (AMPA) in water. PRP-X100 poly(styrene-divinylbenzene)-trimethylammonium anion-exchange cartridges (20 x 2 mm, 10 microm) were selected for the SPE of glyphosate and AMPA. The ionic compounds present in the samples strongly influenced the extraction of both analytes; however, when an on-line ion-exchange clean-up step was introduced before sample SPE, the problem was largely solved. By processing 100-ml samples detection limits better than 0.02 microg/l for glyphosate and 0.1 microg/l for AMPA were achieved in river water. Both analytes were unstable in solution and the approach of storing samples on the PRP-X100 SPE cartridges was evaluated for a period of 1 month under three different storage conditions (deep freeze, refrigeration and 20 degrees C).  相似文献   

15.
The derivatization of biogenic amines such as putrescine, cadaverine, spermidine and spermine with dansyl chloride in solid phase extraction cartridges is described. Different types of filling materials were tested in order to have the highest retention of the different analytes. The best results were obtained by using C18 cartridges. The optimal conditions were: amine solution buffered at pH 12, 2 mM dansyl chloride (acetone-bicarbonate solution 20 mM (pH 9-9.5), 2 + 3 v/v) as reagent concentration, room temperature and 30 min reaction time. The developed procedure was applied to the determination of these polyamines in urine samples from healthy controls and cancer patients using HPLC with 1,7-diaminoheptane as internal standard. The concentrations ranged from 0.5 to 5 micrograms mL-1 and the detection limits were 10 ng mL-1 for all polyamines. By concentrating the urine extracts, the detection limits were improved down to 2 ng mL-1. The accuracy and the precision of the method were tested. The proposed dansylation method is advantageous with respect to solution dansylation. It improves the total analysis time, avoids high temperatures that can affect the thermal stability of the derivatives and could make possible the automation of the procedure.  相似文献   

16.
A continuous-flow purge-and-trap-GC-MS system was developed for on-line monitoring of THMs (trihalomethanes) in drinking water. Three systems with different traps and purging flow-rates are discussed. In order to minimize interference from water vapor, total purge gas volume and injection temperature were controlled during analysis. Shorter sample concentration time and GC separation time reduced total cycle time to less than 5 min. The detection limits of the system could be lowered to 10 ppt, 25 ppt, 40 ppt, and 50 ppt (w/w) for CHCl3, CHCl2Br, CHClBr2, and CHBr3, respectively. This system could detect changes in sample concentration when applied to the on-line monitoring of THMs in drinking water.  相似文献   

17.
A simple, fast and sensitive liquid chromatography-mass spectrometry (LC-MS) method with automated on-line extraction using turbulent flow chromatography (TFC) for the determination of five catechins in human plasma was developed. In this method, after on-line extraction by its injection onto an extractor column at turbulent flow, five catechins were backwashed onto a reversed phase column via on-line column switching and separated chromatographically at a laminar flow of 1 ml min(-1). Using this tandem LC-LC-MS system, the extraction, the separation and the quantitation of five catechins in human plasma could be achieved with satisfactory selectivity and sensitivity. The limit of detection (S/N = 3) ranged from 0.6 to 2 ng ml(-1). The described procedure was very simple and rapid since no off-line sample preparation was required, total analysis time being 18.5 min.  相似文献   

18.
Solid-phase extraction (SPE) was coupled to ion-trap mass spectrometry to determine clenbuterol in urine. For SPE a cartridge exchanger was used and, after extraction, the eluate was directly introduced into the mass spectrometer. For two types of cartridges, i.e. C18 and polydivinylbenzene (PDVB), the total SPE procedure (including injection of 1 mL urine, washing, and desorption) has been optimised. The total analysis, including SPE, elution, and detection, took 8.5 min with PDVB cartridges, while an analysis time of 11.5 min was obtained with C18 cartridges. A considerable amount of matrix was present after extraction of urine over C18 cartridges, resulting in significant ion suppression. With PDVB cartridges, the matrix was less prominent, and less ion suppression was observed. For single MS, a detection limit (LOD) of about 25 ng/mL was found with PDVB cartridges. With C18 cartridges an LOD of only about 50 ng/mL could be obtained. Applying tandem mass spectrometry (MS/MS) did not lead to an improved LOD due to an interfering compound. However, a considerable improvement in the LOD was obtained with MS3. The selectivity and sensitivity were increased by the combination of efficient fragmentation of clenbuterol and reduction of the noise. Detection limits of 2 and 0.5 ng/mL were obtained with C18 and PDVB cartridges, respectively. The ion suppression was 4 to 45% (concentration range: 250 to 1.0 ng/mL) after extraction of urine using PDVB cartridges, and up to 70% ion suppression was observed using C18 cartridges. With MS4, no further improvement in selectivity and sensitivity was achieved, due to inefficient fragmentation of clenbuterol and no further reduction of noise.  相似文献   

19.
In order to reduce time of analysis, a new pressurized liquid extraction (PLE) method that automatically and rapidly achieves quantitative and selective extraction of 39 polybrominated diphenyl ether (PBDE) congeners in sediment samples was optimized. It consists of on-line cleanup by inclusion of sorbents in the extraction cell. The new method was compared with a conventional method based on the use of Soxhlet extraction followed by solid-phase extraction (SPE) with cartridges. The instrumental determination was performed by GC-MS, using negative chemical ionization in the selected-ion monitoring mode. Recoveries from 47 to 82% were obtained for spiked tri- to hepta-PBDE congeners in sediment sample. The repeatability of replicate extractions was better than 15% relative standard deviation. The detection limits obtained with the new developed method were between 1 and 46 pg/g dry weight. The reduction in the sample preparation (extraction + cleanup) time (from days to 30 min) with a similar efficiency than that afforded by the conventional Soxhlet extraction-SPE cleanup technique indicates the suitability of this method. The method was applied to sediment samples where the analytes were detected in the range of 0.86-2.49 ng/g dry mass.  相似文献   

20.
A high-performance liquid chromatography (HPLC) system with fluorescence detection and an automated on-line solid-phase extraction procedure for fumonisins B1 and B2 in corn and corn-based products is described. Different amounts of strong anion-exchange, C18 and end-capped C18 (C(18 ec)) silicas were tested for sample clean-up. Various HPLC parameters were analyzed. The best methodology was found to be extraction with acetonitrile-water and clean up on C(18 ec) disposable extraction cartridges. The system has the advantage of running in an unattended mode of operation and allows processing of 40 samples without system refuel, performing clean-up, o-phthaldialdehyde derivatization, injection and fumonisin detection by fluorescence detection linked to a computer integrator for automated data processing. Recoveries were performed with corn and corn-based feed samples (n=3) spiked with 0.1, 0.5, 1.0, 5.0 and 10 microg/g. Average recoveries for corn and corn-based feed were, respectively, 92.6 and 88.3% with relative standard deviations (RSDs) of 5.04 and 6.22%, for fumonisin B1 and 91.2 and 89.0% with RSDs of 5.84 and 7.88% for fumonisin B2. Detection limits (S/N=3) for corn and corn-based feed were approximately 0.03 microg/g for fumonisin B1 and 0.05 microg/g for fumonisin B2  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号