首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Peanut proteins can cause allergenic reactions that can result in respiratory and circulatory effects in the body sometimes leading to shock and death. The determination of peanut proteins in foods by analytical methods can reduce the risk of serious reactions in the highly sensitized individual by allowing for the detection of these proteins in a food at various stages of the manufacturing process. The method performance of 4 commercially available enzyme-linked immunosorbent assay (ELISA) kits was evaluated for the detection of peanut proteins in milk chocolate, ice cream, cookies, and breakfast cereals: ELISA-TEK Peanut Protein Assay, now known as "Bio-Kit" for peanut proteins, from ELISA Technologies Inc.; Veratox for Peanut Allergens from Neogen Corp.; RIDASCREEN Peanut Kit from R-Biopharm GmbH; and ProLisa from Canadian Food Technology Ltd. The 4 test kits were evaluated for accuracy (recovery) and precision using known concentrations of peanut or peanut proteins in the 4 food matrixes. Two different techniques, incurred and spiked, were used to prepare samples with 4 known concentrations of peanut protein. Defatted peanut flour was added in the incurred samples, and water-soluble peanut proteins were added in the spiked samples. The incurred levels were 0.0, 10, 20, and 100 microg whole peanut per g food; the spiked levels were 0.0, 5, 10, and 20 microg peanut protein per g food. Performance varied by test kit, protein concentration, and food matrix. The Veratox kit had the best accuracy or lowest percent difference between measured and incurred levels of 15.7% when averaged across all incurred levels and food matrixes. Recoveries associated with the Veratox kit varied from 93 to 115% for all food matrixes except cookies. Recoveries for all kits were about 50% for cookies. The analytical precision, as measured by the variance, increased with an increase in protein concentration. However, the coefficient of variation (CV) was stable across the 4 incurred protein levels and was 7.0% when averaged across the 4 food matrixes and analytical kits. The R-Biopharm test kit had the best precision or a CV of 4.2% when averaged across all incurred levels and food matrixes. Because measured protein values varied by test kit and food matrix, a method was developed to normalize or transform measured protein concentrations to an adjusted protein value that was equal to the known protein concentration. The normalization method adjusts measured protein values to equal the true protein value regardless of the type test kit or type food matrix.  相似文献   

2.
Results are reported for an interlaboratory validation study of 2 commercially available Iateral flow devices (dipstick tests) designed to detect peanut residues in food matrixes. The test samples used in this study were cookies containing peanuts at 7 different concentrations in the range of 0-30 mg peanuts/kg food matrix. The test samples with sufficient and proven homogeneity were prepared in our laboratory. The analyses of the samples (5 times per level by each laboratory) were performed by 18 laboratories worldwide which submitted a total of 1260 analytical results. One laboratory was found to be an outlier for one of the test kits. In general, both test kits performed well. However, some false-negative results were reported for all matrixes containing < 21 mg peanuts/kg cookie. It must be stressed that the test kits were challenged beyond their cut-off limits (> or = 5 mg/kg, depending on the food matrix). One test kit showed fewer false-negative results, but it led to some false-positive results for the blank materials. The sensitivity of the dipstick tests approaches that achieved with enzyme-linked immunosorbent assays.  相似文献   

3.
Peanut is the food group mostly associated with severe and fatal allergic reactions. In the United States, more than 90% of peanut-allergic individuals' serum IgE recognized peanut proteins Ara h 1 and Ara h 2, thus establishing these proteins as major peanut allergens. The amount of Ara h 1 and Ara h 2 in 3 varieties of peanut cultivars that are commonly processed in the industrialized countries was determined to be 12-16 and 6-9%, respectively. Current commercial peanut test kits use polyclonal peanut-specific antibodies to detect soluble or buffer extractable peanut proteins. Because the 2 major peanut allergens Ara h 1 and Ara h 2 are isolated from soluble peanut proteins, it is generally assumed that these commercial kits can detect peanut allergens, although none of these kits claims to detect peanut allergen. This study showed for the first time that the peanut test kits could, in fact, detect major peanut allergens Ara h 1 and Ara h 2 in both native or heat-denatured structures; therefore, these kits qualified to be classified as peanut allergen enzyme-linked immunosorbent assays.  相似文献   

4.
建立了花生中36种农药及其代谢物残留的超高效液相色谱-串联质谱(UHPLC-MS/MS)快速检测技术。采用乙腈提取,增强型脂质去除净化剂(EMR-Lipid)净化,正离子多反应监测(MRM)模式测定。结果表明,所有农药的线性相关系数均大于0.994,在0.005,0.01,0.10 mg/kg 3个加标水平下,36种农药的平均回收率为70.4%~119%,相对标准偏差(RSDs)为1.3%~19.4%,方法的定量下限为0.002 5~0.05 mg/kg。该方法简便、快速,灵敏度高、净化效果好,适用于花生中农药多残留的快速检测分析。  相似文献   

5.
To protect the allergic consumer, analytical methods need to be capable of detecting allergens in finished products that typically contain multiple allergens. An LC/MS/MS method for simultaneous detection of seven allergens was developed and compared with commercially available ELISA kits. The detection capabilities of this novel method were demonstrated by analyzing incurred material containing milk, egg, soy, peanut, hazelnut, walnut, and almond. Bread was chosen as a model matrix. To assess the influence of baking on the method's performance, analysis was done before and after baking. The same samples were analyzed with ELISA test kits from ELISA Systems, Morinaga, Neogen, and r-Biopharm. Peanut, hazelnut, walnut, and almond could be detected with both ELISA and LC/MS/MS regardless of whether the product was baked or not. LC/MS/MS clearly showed superior detection of milk in processed matrixes compared to ELISA, which exhibited significantly lower sensitivities when analyzing the baked products. Similar results were obtained when analyzing egg; however, one kit was capable of detecting egg in the processed samples as well.  相似文献   

6.
Peanuts are one of the 8 most common allergenic foods and a large proportion of peanut-allergic individuals have severe reactions, some to minimal exposure. Specific protein constituents in the peanuts are the cause of the allergic reactions in sensitized individuals who ingest the peanuts. To avoid accidental ingestion of peanut-contaminated food, methods of analysis for the determination of the allergenic proteins in foods are important tools. Such methods could help identify foods inadvertently contaminated with peanuts, thereby reducing the incidence of allergic reactions to peanuts. Commercial immunoassay kits are available but need study for method performance, which requires reference materials for within- and between-laboratory validations. In this study, National Institute of Standards and Technology Standard Reference Material 2387 peanut butter was used. A polytron homogenizer was used to prepare a homogenous aqueous Peanut Butter suspension for the evaluation of method performance of some commercially available immunoassay kits such as Veratox for Peanut Allergen Test (Neogen Corp.), Ridascreen Peanut (R-Biopharm GmbH), and Bio-Kit Peanut Protein Assay Kit (Tepnel). Each gram of the aqueous peanut butter suspension contained 20 mg carboxymethylcellulose sodium salt, 643 microg peanut, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. The suspension was homogenous, stable, reproducible, and applicable for adding to ice cream, cookies, breakfast cereals, and chocolate for recovery studies at spike levels ranging from 12 to 90 microg/g.  相似文献   

7.
Detection of hazelnuts and almonds using commercial ELISA test kits   总被引:1,自引:0,他引:1  
Three commercial sandwich enzyme-linked immunosorbent assay (ELISA) test kits for the detection of hazelnuts and almonds were evaluated. Limits of detection and dynamic ranges were determined for hazelnuts and almonds spiked into cooked oatmeal, dipping chocolate, and muffins (baked). The limit of detection values varied from 1 to 38 μg/g, depending on the food matrix and ELISA test kit. Percent recoveries based on the standards supplied with the test kits varied from 10% to 170%. It is impossible to ascertain whether the percent recoveries reflect the performance of the ELISAs or differences between the protein content of the nuts used to spike the samples and the test kit standards. Unfortunately, reference materials do not exist that can be used to compare the results from different test kits and standardize the test kit standards. Also, insufficient knowledge regarding the epitope specificity of the antibodies used in the ELISAs further hinders interpretation of the results generated by the different test kits.  相似文献   

8.
The problem of allergen analysis using ELISA kits from different commercial products giving significantly different results is widely acknowledged. The effect on proficiency testing results is that different assigned values have to be generated for the different kits used. Some experimental Food Analysis Performance Assessment Scheme (FAPAS) proficiency tests aimed to establish whether the use of a standardised calibrant could be used to normalise the complete data set without recourse to differentiation. Three recent FAPAS proficiency tests (2776 peanut, 2778 soya and 2781 gluten) sent out a second spiked sample, in addition to the usual spiked and unspiked samples. Further analysis of the data was undertaken after the completion of the tests. The ratio of the submitted results for the two spiked samples yielded complete data sets which could be tested for normality of the distribution. Where the raw data for each individual test sample was clearly non-normal and multi-modal, the ratio data yielded a much more normal and symmetrical distribution. The use of one of the test samples as a single-point calibrant has some limitations but the principle of applying a standardisation clearly works. The development of internationally recognised sets of certified reference calibration standards for use by allergens testing laboratories would greatly benefit the analysis.  相似文献   

9.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 and total aflatoxins at European regulatory limits. The test portion is extracted with methanol-water (8 + 2) for dried figs and paprika, and with methanol-water (8 + 2) plus hexane (or cyclohexane) for peanut butter and pistachios. The sample extract is filtered, diluted with phosphate buffer saline, and applied to an immunoaffinity column. The column is washed with water and the aflatoxins are eluted with methanol. Aflatoxins are quantitated by reversed-phase LC with post-column derivatization (PCD) involving bromination. PCD is achieved with either an electrochemical cell (Kobra cell) and addition of bromide to the mobile phase or pyridinium hydrobromide perbromide. Determination is by fluorescence. Peanut butter, pistachio paste, dried fig paste, and paprika powder samples, both naturally contaminated with aflatoxins and containing added aflatoxins, were sent to 16 collaborators in 16 European countries. Test portions of samples were spiked at levels of 2.4 and 9.6 ng/g for total aflatoxins which included 1.0 and 4.0 ng/g aflatoxin B1, respectively. Recoveries for total aflatoxins ranged from 71 to 92% with corresponding recoveries for aflatoxin B1 of 82 to 109%. Based on results for spiked samples (blind duplicates at 2 levels) as well as naturally contaminated samples (blind duplicates at 4 levels, including blank), the relative standard deviation for repeatability ranged from 4.6 to 23.3% for total aflatoxins and from 3.1 to 20.0% for aflatoxin B1. The relative standard deviation for reproducibility ranged from 14.1 to 34.2% for total aflatoxins, and from 9.1 to 32.2% for aflatoxin B1. The method showed acceptable within-laboratory and between-laboratory precision for all 4 matrixes, as evidenced by HORRAT values <1, at the low levels of determination for both total aflatoxins and aflatoxin B1.  相似文献   

10.
Food-allergic individuals have to strictly avoid the offending food because no causative immunotherapies are available. Thus, reliable labelling of allergenic ingredients or precautionary labelling of cross-contacts with potential allergens is of major importance. Verification of compliance with labelling requirements and identification of cross-contacts demand test methods that enable the specific and sensitive detection of the analyte. Brazil nut (Bertholletia excelsa) is such a food commodity with allergenic potential. We describe the development of a novel qualitative real-time polymerase chain reaction (PCR) specific for Brazil nut DNA and its comparison with a qualitative commercially available lateral flow device (LFD) that detects Brazil nut protein. Specificity was investigated with 58 foods, and no false-positive reactions were observed in real-time PCR. The sensitivity was investigated with spiked chocolate and incurred dough samples as well as cookies baked thereof. The simultaneous spiking of matrices with identical amounts of Brazil nut and peanut between 5 and 100,000 mg/kg allowed the verification of the spike quality with two peanut-specific enzyme-linked immunosorbent assay. The real-time PCR detected Brazil nut in all three matrices down to the lowest investigated spike level of 5 mg/kg. The real-time PCR results from the analysis of 15 retail samples were confirmed by LFD results and were in concordance with the labelling of products. The real-time PCR showed unparalleled specificity, and primary data indicated potentially quantitative features in spiked and retail samples. Because of entirely reproducible chemistry of this real-time PCR, this is the first generally available Brazil nut-specific detection method with an appropriate sensitivity to help avoid severe allergic reactions for Brazil nut-allergic individuals.  相似文献   

11.
An immunoaffinity column was prepared from rabbit polyclonal antiserum for the determination of peanut protein from food matrixes. The anti-peanut immunoglobulin G was isolated from antiserum by affinity chromatography on a column coupled with peanut protein and then attached to an AminoLink gel. The column was applied to the determination of peanut protein in chocolate after extraction, immunoaffinity chromatography, and enzyme-linked immunosorbent assay (ELISA). Overall recoveries from chocolate spiked with 0.2-3.2 micrograms/g of peanut protein averaged 77% (range, 72-84%), and the minimum detection limit was 0.1 microgram/g. Chromatography of extracts with the column improved detection limit and eliminated the matrix effect experienced with direct ELISA of chocolate extracts.  相似文献   

12.
Deoxynivalenol (DON), commonly referred to as vomitoxin, belongs to a class of naturally occurring mycotoxins produced by Fusarium fungi. The presence of DON in foods is a human health concern. The frequency of occurrence of DON in wheat is high, although cleaning prior to milling can reduce DON concentration in final products, and food processing can partially degrade the toxin. This paper describes a method for the determination of DON in some major wheat food products, including bread, breakfast cereals, pasta, pretzels, and crackers. Test samples containing 5% polyethylene glycol were extracted with water. After blending and centrifuging, the supernatant was diluted with water and filtered through glass microfiber filter paper. The filtrate was then passed through an immunoaffinity column and the toxins eluted with methanol. The toxins were then subjected to RPLC separation and UV detection. The accuracy and repeatability characteristics of the method were determined. Recoveries of DON spiked at levels from 0.5 to 1.5 microg/g in the five processed foods were >70%. SD and RSD values ranged from 2.0 to 23.5% and from 2.0 to 23.2%, respectively. HorRat values were <2 for all of the matrixes examined. The method was found to be acceptable for the matrixes examined. LC/MS/MS with multiple-reaction monitoring was used to confirm the identity of DON in naturally contaminated test samples.  相似文献   

13.
Methods for Vitamin B5 determination in food products remain limited by their low sensitivity and poor selectivity. Here, we have developed a liquid chromatography-mass spectrometry (LC-MS) method for Vitamin B5 determination in wide range of fortified food products. Vitamin B5 was extracted from food samples by heat treatment and analysed by LC-MS in the positive mode using electrospray ionisation (ESI). Vitamin B5 was quantified using hopantenic acid (HOPA) as internal standard after their separation on a C18 narrow-bore column with a gradient of mobile phase made of water/acetonitrile and trifluoroacetic acid (TFA) 0.025%. MS with single ion monitoring mode at mass m/z 220 was used for Vitamin B5 quantification. Calibration curve between 0.5 and 10 microg/ml of Vitamin B5 was linear (r2=0.9993) and the detection limit was determined to be 800 pg. The overall quantitative efficiency of the method was evaluated using Nestle reference sample (infant formula). The intra-assay RSD was 4.8% (n=8), the inter-assay RSD 6.4% (n=4) and the recoveries of the spiked samples were above 95%. Application of the LC-MS method to Vitamin B5 determination in wide range of fortified food products including three US National Institute of Standards and Technology (NIST) reference samples (RM 8435, RM 8415 and SRM 1546) shows consistent results with those obtained by microbiology and recoveries of Vitamin B5 between 93 and 104% for the spiked samples.  相似文献   

14.
Lateral flow devices (LFDs) are qualitative immunochromatographic tests for the rapid and specific detection of target analytes. We investigated commercially available LFDs for their ability to detect potentially allergenic peanut and hazelnut in raw cookie dough and chocolate, two important food matrices in the industrial production of cookies. Each three commercial LFDs for the detection of hazelnut and peanut were performed according to the manufacturers’ instructions. All LFDs had comparably satisfactory specificity that was investigated with a variety of characteristic foods and food ingredients used in the production of cookies. In concordance with hazelnut-specific enzyme-linked immunosorbent assays (ELISAs), walnut was the most cross-reactive food for hazelnut-specific LFD. The sensitivity was verified in raw cookie doughs and chocolates that were either spiked with peanut or hazelnut between 1 and 25 mg/kg, respectively. Two hazelnut-specific LFDs detected hazelnut at a level of 3.5 mg/kg in both matrices, whereas the third LFD detected hazelnut at a level of 3.9 mg/kg in dough and 12.5 mg/kg in chocolate. Two peanut-specific LFDs detected peanut at a level of 1 mg/kg in both matrices. The third LFD detected peanut at a level of 14.2 mg/kg in chocolate and 4 mg/kg in dough. In conclusion, specific and sensitive LFD were identified for each hazelnut and peanut, having a level of sensitivity that is comparable to commercial ELISA for the investigated matrices. Such sensitive, specific, and rapid tests are useful analytical tools for allergen screening and sanitation in the industrial manufacture of foods.  相似文献   

15.
In the United States, peanut is one of the main sources of food allergens. Similarly, celery is a common allergenic food in Western Europe. Severe allergic reactions to both foods are common. Unexpected allergic reactions can occur after the consumption of celery- and peanut-free foods as a result of inadvertent cross-contaminations during manufacturing. Therefore, in cooperation with a flavor manufacturer, we monitored the cleaning process of slurry preparation equipment with regard to contaminations of follow-up products with celery and peanut compounds. Washing water samples taken after different cleaning steps and follow-up products were analyzed for the presence of celery and peanut traces with a celery-specific real-time polymerase chain reaction (PCR) and a peanut-specific sandwich enzyme-linked immunosorbent assay (ELISA). PCR and ELISA were compared with a nonspecific protein assay to evaluate whether the detection of protein traces can be a fast and cost-effective method for monitoring the effectiveness of wet cleaning procedures. Additionally, the allergenic potential of the celery and peanut mush, which were used as source material, were measured by a mediator release assay using a rat basophilic leukemia (RBL) cell line. In conclusion, the quantification of total protein in washing water was suitable for monitoring the cleaning process. Our study also revealed evidence that, in cases where wet cleaning is applicable, allergenic traces can be removed with high efficiency.  相似文献   

16.
The EZ Gluten assay is a rapid immunochromatographic screening method for qualitative detection of gluten in raw and cooked foods and beverages and on environmental surfaces. This AOAC Performance Tested Method study evaluated the EZ Gluten assay as an effective method for the detection of gluten in four selected matrixes: rice flour, cooked dough, beer, and dog food. In addition, the method was evaluated for its effectiveness in detecting gluten contamination of > or =1 microg/2 in.2 (25 cm2) stainless steel surface area. The EZ Gluten demonstrated 100% specificity [probability of detection (POD) 0.00, confidence interval (CI) 0.00-0.01] and 99% sensitivity (POD 0.99, CI 0.97-0.995) at the 10 ppm level for all four matrixes, and 100% specificity (POD 0.00, CI 0.00-0.11) and sensitivity (POD 1.00, CI 0.886-1.00) at the 1 microg level on the stainless steel surface. Independent laboratory testing confirmed the internal validation results in one matrix and on the stainless steel surface. Lot-to-lot, stability, and robustness studies provided evidence that the EZ Gluten is a rugged, consistent method for the detection of gluten at levels as low as 10 ppm.  相似文献   

17.
A new method based on matrix solid-phase dispersion (MSPD) extraction was studied to determine aflatoxin B1, B2, G1 and G2 from peanuts. Optimization of different parameters, such as type of solid supports for matrix dispersion and elution solvents were carried out. The method used 2 g of peanut sample, 2 g of C18 bonded silica as MSPD sorbent and acetonitrile as eluting solvent. Recoveries of each aflatoxin spiked to peanut samples at 2.5 ng/g (5 ng/g for aflatoxin G2) level were between 78 and 86% with relative standard deviations ranging from 4 to 7%. The limits of quantification ranged from 0.125 to 2.5 ng/g for the four studied aflatoxins using liquid chromatography (LC) with fluorescence detection. In addition, LC coupled to mass spectrometry with an electrospray interface was used for confirmation of aflatoxins present in real samples. Eleven peanut samples from different countries were analyzed by the proposed method and by using an enzyme-linked immunosorbent assay (ELISA). ELISA test is a good screening method for investigation of these mycotoxins in peanut samples.  相似文献   

18.
The protection of allergic consumers is crucial to the food industry. Therefore, accurate methods for the detection of food allergens are required. Targeted detection of selected molecules by MS combines high selectivity with accurate quantification. A confirmatory method based on LC/selected reaction monitoring (SRM)-MS/MS was established and validated for the quantification of milk traces in food. Tryptic peptides of the major milk proteins beta-lactoglobulin, beta-casein, alphaS2-casein, and K-casein were selected as quantitative markers. Precise quantification was achieved using internal standard peptides containing isotopically labeled amino acids. For each peptide, qualifier and quantifier fragments were selected according to Commission Decision 2002/657/EC. A simple sample preparation method was established without immunoaffinity or SPE enrichment steps for food matrixes containing different amounts of protein, such as baby food, breakfast cereals, infant formula, and cereals. Intermediate reproducibility, repeatability, accuracy, and measurement uncertainty were determined for each matrix. LOD values of 0.2-0.5 mg/kg, e.g., for beta-lactoglobulin, were comparable to those obtained with ELISA kits. An LOQ of approximately 5 mg/kg, expressed as mass fraction skim milk powder, was validated in protein-rich infant cereals. The obtained validation data show that the described LC/SRM-MS/MS approach can serve as a confirmatory method for the determination of milk traces in selected food matrixes.  相似文献   

19.
A liquid chromatography-tandem mass spectrometry method has been developed for the determination of residues of alkylbenzyldimethylammonium, didecyldimethylammonium, didodecyldimethylammonium, and benzyldodecylhydroxyethylammonium compounds in various food matrixes. These quaternary ammonium compounds (QAs) are used in the food industry as disinfectants. According to the Dutch Food Law, the total mass (expressed as cetyltrimethylammonium chloride) of QAs in food products shall not exceed the legislative limit of 0.5 mg/kg. Samples were extracted by a simple salting-out procedure, using acetonitrile and sodium chloride; about 100 samples could be prepared and analyzed daily. Special care had to be taken to thoroughly homogenize samples and to avoid the use of contaminated labware. The method was validated by a procedure in compliance with EU Directive 2002/657. From the matrixes of ice cream and minced meat, recoveries of more than 95% with a relative standard deviation of about 3% were obtained by 3 different analysts (n = 54). Detection limits were in the low microg/kg range. The decision limit (CCalpha) was determined to be 0.55 mg/kg. Dairy and meat products, collected in The Netherlands, were analyzed (761 samples). In 1% of the meat samples, 2% of the ice cream and milkshake samples, and 24% of the whipped cream samples, the Dutch legislative limit was exceeded. Over 2000 injections could be performed on a single column without deterioration of the peak shapes or recoveries.  相似文献   

20.
Peanut allergic reactions can result from the ingestion of even very small quantities of peanut and represent a severe threat to the health of sensitised individuals. The detection of peanut traces in food products is therefore of prime importance. Peanut traces which can be (unintentionally) present in food products have usually undergone one or more processing steps like roasting and baking. Therefore, methods designed to detect such traces have to be capable of detecting heat-treated peanuts. Commonly used methodologies designed to detect peanut traces in food products are enzyme-linked immunosorbent assays (ELISAs) that detect peanut-specific proteins, and polymerase-chain-reaction (PCR)-based methods targeting peanut-specific DNA. A comparative analysis of such methods was performed and the impact of heat treatment on peanut kernels as well as the impact on a peanut-containing food matrix are investigated. Our results show that heat treatments have a detrimental effect on the detection of peanut with either type of method and that both types of methods are affected in a similar manner.  相似文献   