 共查询到20条相似文献,搜索用时 15 毫秒
1.
Four different sheathless electrospray ionization (ESI) configurations were investigated for a nano liquid chromatography (LC) system. The studied configurations were: a column with an integrated emitter, with the ESI potential applied before or after the column, and a column with separate emitter, with the ESI voltage applied at a union before the emitter or at the emitter tip. The results indicates that the efficiency of the LC system is rather independent of the configuration when using 95 microm i.d. columns, acetic mobile phase and standard peptides as a sample. Introduction of post column dead volume seems not to be a critical issue at least with flow rates down to 600 nl/min.  相似文献   

2.
Ying Zhu  Yuan Su  Qun Fang 《Talanta》2010,81(3):1069-452
In this paper, a glass microchip-based emitter with a low-melting-point alloy (LMA) microelectrode and a monolithic tip for electrospray ionization mass spectrometry (ESI-MS) was described. So far, the fabrication of metal microelectrode achieving direct electrical contact in the microchannel of glass chip is still a challenge. A novel fabrication approach for LMA microelectrode in the glass chip was developed to achieve direct electrode-solution electrical contact in the microchannel. An electrode channel and a sample channel were firstly fabricated on a glass chip with a micropore connecting the two channels. The melted LMA was filled into the electrode channel under a pressure of ca. 100 kPa, forming a stable and nicely fitted interface at the micropore between the sample and the electrode channels due to surface tension effect. The melted LMA filled in the electrode channel was then allowed to solidify at room temperature. The channel geometries including the distance between the sample and the electrode channels on the mask and the turning angle of the electrode channel were optimized for fabricating the LMA electrode. In this work, an improved fabrication approach for monolithic emitter tip based on pyramid-shaped tip configuration and stepped grinding method was also developed to fabricate well-defined sharp tips with a smallest tip end size of ca. 15 μm × 50 μm. Two types of emitter tip end including puncher-shaped tip and fork-shaped tip were produced. The emitter with the fork-shaped tip showed better working stability (4.4% RSD, TIC) at nanoliter-scale flow rate of 50 nL/min. The fabrication approaches for the LMA microelectrode and emitter tip are simple and robust, and could be carried out in most of routine laboratories without the need of complicated and expensive instruments. The performance of the emitter was evaluated in the analysis of reserpine, angiotensin II and myoglobin. A continuous experiment over 6 h demonstrated good stability of the present system in long-term analysis.  相似文献   

3.
The separation of intact proteins, including protein isoforms arising from various amino-acid modifications, employing a poly(styrene-co-divinylbenzene) monolithic capillary column in high-performance liquid chromatography coupled on-line to a time-of-flight mass spectrometer (MS) is described. Using a 250 mm × 0.2 mm monolithic capillary column high-sensitivity separations yielding peak capacities of >600 were achieved with a 2h linear gradient and formic acid added in the mobile phase as ion-pairing agent. The combination of high-resolution chromatography with high-accuracy MS allowed to distinguish protein isoforms that differ only in their oxidation and biotinylation state allowing the separation between structural isoforms. Finally, the potential to separate proteins isoforms due to glycosylation is discussed.  相似文献   

4.
Monolithic capillary columns were prepared via electron beam triggered free radical polymerization within the confines of 0.2 and 0.1mm I.D. capillary columns using ethyl methacrylate and trimethylolpropane triacrylate as monomers as well as 2-propanol, 1-dodecanol and toluene as porogenic system. The influence of column diameter on reproducibility and separation performance was investigated. For evaluation, a protein standard consisting of five proteins in the range of 5800-66,000 g mol(-1) was used. Reproducibility was checked by determining the relative standard deviations in retention times, peak widths at half height, asymmetry and resolution. Excellent run-to-run reproducibility was found for both 0.2 and 0.1mm I.D. columns; batch-to-batch reproducibility was good for both column types. In order to enhance the non-polar character of the monolithic columns, lauryl methacrylate-based capillary columns were prepared. These were successfully used for the separation of proteins and a cytochrome c digest.  相似文献   

5.
Summary A sensitive, selective, and rapid method is described for analysis of ceramides in the human stratum coracum by direct coupling of HPLC with an electrospray ion-trap mass spectrometry. Nonaqueous reversed-phase chromatography stabilizes the electrospray ionization, resulting in sensitivity that enables direct measurement of skin lipid extracts with no special sample preparation. Assignment of individual signals to the corresponding ceramide species is based on interpretation of the fragment spectra from MS-MS experiments. This enables much finer differentiation between ceramdies than that achievable by thin-layer chromatography. Summary A sensitive, selective, and rapid method is described for analysis of ceramides in the human stratum corneum by direct coupling of HPLC with an electrospray ion-trap mass spectrometry. Nonaqueous reversed-phase chromatography stabilizes the electrospray ionization, resulting in sensitivity that enables direct measurement of skin lipid extracts with no special sample preparation. Assignment of individual signals to the corresponding ceramide species is based on interpretation of the fragment spectra from MS-MS experiments. This enables much finer differentiation between ceramides than that achievable by thin-layer chromatography.  相似文献   

6.
Zhang L  Ping X  Yang Z 《Talanta》2004,62(1):191-198
The need for a rapid, sensitive, and reliable analytical method for microcystin-LR has been emphasized by the awareness of toxic cyanobacteria as a human-health risk through drinking water. Microcystin-LR is the most commonly reported microcystin which is produced by cyanobacteria. The WHO guideline for microcystin-LR in drinking water is 1 μg/l. In this paper, an effective method has been developed by application of high-performance liquid chromatography/tandem electrospray ionization mass detector in the determination of microcystin-LR in surface water sample. At the LC-MS-MS CID-full scan mode, different relative collision energies have been tested with 30% being used for further microcystin-LR analysis. The possible mass dissociation path has been proposed. Based on 30% relative collision energy, present method has an excellent method detection limit (MDL), which is as low as 2.6 ng/l. To the best of our knowledge, this represents one of the most sensitive methods in existence for the microcystin-LR analysis. This method has also been validated by evaluation of the calibration linearity, precision, accuracy, recovery, and mass ratio stability.  相似文献   

7.
We examined the utility of a monolithic capillary column in the analysis of pyridylaminated oligosaccharides. Fluorescence detection and mass spectrometry were used to monitor a series of oligosaccharides. Although the total-ion chromatogram appeared similar to that obtained with fluorescence detection, the sensitivity of this technique was limited, especially in the case of smaller oligosaccharides. This limitation was overcome by applying selected ion current monitoring. Further, the capillary column also exhibited good reproducibility. We showed that the retention times obtained by using the monolithic capillary column could be converted into the standard data to enable comparison of the experimental data with the existing data. Furthermore, our studies revealed an important difference in the separation profile, i.e., the monolithic capillary column could resolve smaller oligosaccharides to a greater extent.  相似文献   

8.
A fast method using high-performance liquid chromatography based on two monolithic columns has been developed for the simultaneous determination of isoflavones extracted from soybeans and derived foods. The 12 main isoflavones were resolved in 10 min in two coupled monolithic columns working at 35 °C using a elution gradient of acidified water (0.1% acetic acid) and methanol (0.1% acetic acid) at a flow rate of 5 mL min−1. Retention time and relative area standard deviations were below 1% for all isoflavones. The method developed was successfully applied to several soy food samples and spiked samples. Total isoflavone concentration in sampled soy foods ranged from 34.28 mg L−1 to 4.29 mg g−1.  相似文献   

9.
啤酒中单糖的衍生化HPLC-ESI-MS测定方法研究   总被引:4,自引:0,他引:4  
单糖类样品在溶液中非常稳定,难于离子化,不适合于进行ESI-MS检测。采用1-苯基-3-甲基-5-吡唑啉酮(PMP)将糖类物质衍生化,HPLC-ESI-MS在线联用,选择性离子扫描方式对几种啤酒样品中的5种单糖进行了分离检测。检出限可达到80pg。  相似文献   

10.
Arsenic pollution of public water supplies has been reported in various regions of the world. Recently, some cancer patients are treated with arsenite (AsIII); most Japanese people consume seafoods containing large amounts of negligibly toxic arsenic compounds. Some of these arsenic species are metabolized, but some remain intact. For the determination of toxic AsIII, a simple, rapid and sensitive method has been developed using electrospray ionization mass spectrometry (ESI-MS). AsIII was reacted with a chelating agent, pyrrolidinedithiocarbamate (PDC, C4H8NCSS-) and tripyrrolidinedithiocarbamate-arsine, As(PDC)3, extracted with methyl isobutyl ketone (MIBK). A 1 μL aliquot of MIBK layer was directly injected into ESI-MS instrument without chromatographic separation, and was detected within 1 min. Arsenate (AsV) was reduced to AsIII with thiosulfate, and then the total inorganic As was quantified as AsIII. This method was validated for the analysis of urine samples. The limit of detection of As was 0.22 μg L−1 using 10 μL of sample solution, and it is far below the permissible limit of As in drinking water, 10 μg L−1, recommended by the WHO. Results were obtained in < 10 min with a linear calibration range of 1-100 μg L−1. Several organic arsenic compounds in urine did not interfere with AsIII detection, and the inorganic As in the reference materials SRM 2670a and 1643e were quantified after the reduction of AsV to AsIII.  相似文献   

11.
Yoon KH  Lee SY  Jang M  Ko SH  Kim W  Park JS  Park I  Kim HJ 《Talanta》2005,66(4):831-836
A simple, fast and sensitive high-performance liquid chromatography (HPLC)-electrospray ionization (ESI) tandem mass spectrometric method (LC-MS/MS) has been developed for determination of propiverine and propiverine N-oxide metabolite in human plasma using oxybutynin as internal standard. Instead of extracting propiverine from plasma using organic solvents, which should be separated from the aqueous phase and evaporated before injecting the sample into the chromatograph, plasma sample containing propiverine and N-oxide was directly injected after precipitating proteins with acetonitrile. Numerous compounds in the plasma did not interfere with the highly specific multiple reaction monitoring in tandem mass spectrometric detection following C8 reversed-phase chromatographic separation under conditions that eluted propiverine, N-oxide and oxybutynin within 2 min (0.1% formic acid in water/acetonitrile, 25:75, v/v). The LC-MS/MS method and an alternative LC-MS method, using methyl-t-butyl ether extraction and selected ion monitoring, were validated over 1-250 ng ml−1 of propiverine and 2 to 500 ng ml−1 of N-oxide, and successfully applied in a pharmacokinetic study. The lower limit of quantitation was 1 ng ml−1 for propiverine and 2 ng ml−1 for N-oxide in both methods.  相似文献   

12.
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.  相似文献   

13.
A method was developed for the fast separation of a myoglobin digest using a monolithic RP 18 silica capillary column of 100 μm I.D. The results were compared with those obtained with a particulate RP 18 silica capillary column of 100 μm I.D. at a flow-rate between 0.6 and 1.2 μl/min. The digest was analyzed at the monolithic column at a flow-rate up to 2.8 μl/min. This high flow-rate could not be applied to the particulate column due to the high back-pressure. When the starting composition of the gradient was changed from 0 to 20% and a gradient steepness of 16%/min was used, the analysis time was less than 4 min. A positive Mascot identification score of 115 was achieved for the MS–MS data. When a lower gradient steepness was employed, the chromatographic resolution and the peak capacity did not increase for most compounds. The intraday repeatability for the retention time of the monolithic column was better than 1.5% at 2.8 μl/min and even less than 0.5% using a flow-rate of 0.6 or 1.0 μl/min. For the particulate column, it was between 0.5 and 1.4% for a flow-rate of 0.6 μl/min, probably due to the high column back-pressure. The interday reproducibility for the retention time of the monolithic column was less than 0.9% using a flow-rate of 1.0 μl/min.  相似文献   

14.
The presence of arginine as the naturally occurring amino acid with the highest gas-phase basicity strongly influences the fragmentation behavior of peptides undergoing collision-induced dissociation. Using a derivatization procedure recently developed in our group, based on a reversible reaction of the guanidino group with 2,3-butanedione and an arylboronic acid, we examined how this label affects the fragmentation patterns of labeled versus unlabeled peptides in MS/MS experiments. As part of this fundamental study, two groups of model peptides (angiotensins and bradykinins) as well as tryptic peptides were labeled according to our protocol and subjected to collision-induced dissociation (CID) in both a triple quadrupole and a quadrupole ion trap instrument. It was found that for angiotensins containing an AspArg sequence, C-terminal cleavage at Asp that occurs for native peptides was completely inhibited in Arg-labeled peptides. For bradykinins and peptides obtained from tryptic digests of standard proteins, some sample peptides were little affected by the tagging of arginine residues. Others, in contrast, exhibited an almost total loss of nonspecific backbone cleavage and their fragment ion spectra were dominated by loss of the arginine tag. These and other experimental results are discussed in view of the nature of the arginine tag and the concept of proton mobility.  相似文献   

15.
Conventional electrospray ionization mass spectrometry (ESI-MS) is widely used for analysis of solution samples. The development of solid-substrate ESI-MS allows direct ionization analysis of bulky solid samples. In this study, we developed pipette-tip ESI-MS, a technique that combines pipette tips with syringe and syringe pump, for direct analysis of herbal powders, another common form of samples. We demonstrated that various herbal powder samples, including herbal medicines and food samples, could be readily online extracted and analyzed using this technique. Various powder samples, such as Rhizoma coptidis, lotus plumule, great burdock achene, black pepper, Panax ginseng, roasted coffee beans, Fructus Schisandrae Chinensis and Fructus Schisandrae Sphenantherae, were analyzed using pipette-tip ESI-MS and quality mass spectra with stable and durable signals could be obtained. Both positive and negative ion modes were attempted and various compounds including amino acids, oligosaccharides, glycosides, alkaloids, organic acids, ginosensides, flavonoids and lignans could be detected. Principal component analysis (PCA) based on the acquired mass spectra allowed rapid differentiation of closely related herbal species.  相似文献   

16.
Hepatocellular carcinoma (HCC) is one of the top five cancers with the highest incident of a disease worldwide. To understand the mechanisms of hepatocarcinogenesis, proteomics analysis provides a powerful tool to identify proteins that associate with HCC. We developed a two-step procedure for mapping of HCC proteomics. In the first step, in order to simplify the complexity of proteomics of HCC, the subfractionation of complex protein mixtures in HCC into “subproteomes” is presented based on the solubility of protein. While in the second step an automate comprehensive two-dimensional (2D) separation system, coupling strong cation-exchange (SCX) in the first dimension with capillary reversed-phase chromatography (cRPLC) in the second dimension is developed further to separate and analyze proteins associated with HCC. By using this system, complex sample can be injected, desalted, separated and analyzed in complete automatization. The procedure for proteomics analysis was found to be applied for proteins with great molecular mass (>100 000), small molecular mass (<20 000), highly basic (pI > 9.5) and hydrophobicity, which are not well resolved in 2D-gel electrophoresis. In total 229 proteins were identified by using the described proteomics platform. Among them, several proteins related to the process of carcinogenesis were investigated further.  相似文献   

17.
We present a detailed optimization and characterization of the analytical performance of SU-8-based emitters for electrospray ionization mass spectrometry (ESI/MS). The improved SU-8 fabrication process presented here enhances patterning accuracy and reduces the time and cost of fabrication. All emitters are freestanding and enable sample delivery by both pressure-driven and spontaneous flows. The optimized emitter design incorporates a sharp, double-cantilevered tip implemented to the outlet of an SU-8 microchannel and provides highly sensitive ESI/MS detection. Moreover, the optimized design allows the use of relatively large microchannel dimensions (up to 200 x 50 microm(2), w x h) without sacrificing the detection sensitivity. This is advantageous with a view of preventing emitter clogging and enabling reproducible analysis. The measured limits of detection for the optimized emitter design were 1 nM for verapamil and 4 nM for Glu-fibrinopeptide B with good quantitative linearities between 1 nM and 10 microM (R(2) = 0.9998) for verapamil and between 4 nM and 3 microM (R(2) = 0.9992) for Glu-fibrinopeptide B. The measured tip-to-tip repeatability for signal intensity was 14% relative standard deviation (RSD) (n = 3; 5 microM verapamil) and run-to-run repeatability 4-11% RSD (n = 4; 5 microM verapamil) for all individual emitters tested. In addition, long-term stability of < 2% RSD was maintained for timescales of 30 min even under free flow conditions. SU-8 polymer was also shown to be chemically stable against most of the tested electrospray solvents.  相似文献   

18.
Sangoi MS  Todeschini V  Steppe M 《Talanta》2011,84(4):905-1079
In the present study, a rapid validated stability-indicating LC method was established and comprehensive stress testing of fesoterodine was carried out according to ICH guidelines. Fesoterodine was subjected to stress conditions of acid and basic hydrolysis, oxidation, photolysis and thermal decomposition. The degradation products formed under stress conditions were investigated by LC-UV and LC-ESI-MS. Successful separation of the drug from its degradation products was achieved on a monolithic C18 column (100 mm × 4.6 mm i.d.) maintained at 45 °C using acetonitrile-methanol-0.03 mol L−1 ammonium acetate (pH 3.8) (30:15:55, v/v/v) as the mobile phase. The flow rate was 2.4 mL min−1 and the detection wavelength was 208 nm. Validation parameters such as specificity, linearity, precision, accuracy, and robustness were evaluated. Chromatographic separation was obtained within 2.5 min and it was suitable for high-throughput analysis. Fragmentation patterns of degradation products formed under different stress conditions were studied and characterized through LC-ESI-MS fragmentation. Based on the results, a drug degradation pathway was proposed, and the validated LC method was successfully applied to the quantitative analysis of fesoterodine in tablet dosage forms, helping to improve quality control and to assure therapeutic efficacy.  相似文献   

19.
A prototype array of monolithic liquid chromatography (LC) columns was prepared in a plastic microfluidic device for the off-line interface with matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The microfluidic channels were fabricated on a cyclic olefin copolymer (COC) plate by hot embossing. An array of methacrylate monolithic columns was prepared in the microfluidic channels by UV-initiated polymerization. The deposition system employed a pulsed electric field to transfer the effluents from multiple columns directly onto MALDI targets with a non-contact deposition method reported by Ericson et al. [C. Ericson, Q.T. Phung, D.M. Horn, E.C. Peters, J.R. Fitchett, S.B. Ficarro, A.R. Salmon, L.M. Brill, A. Brock, Anal. Chem. 75 (2003) 2309]. To characterize the off-line interface of the multiple-channel microchip LC and the MALDI-MS for the analysis of peptide mixtures, the separation efficiency and reproducibility tests in each column were carried out by separating a peptide mixture from tryptic digested proteins and depositing the multiple effluents simultaneously on the MALDI target plate. Using a MALDI-TOF mass spectrometer with a mass accuracy of +/-1 Da for peptide assignments of digested bovine serum albumin (BSA), amino acid sequence coverage of around 59% was obtained for the microchip LC-MALDI-MS compared to 23% obtained by the MALDI-MS method without LC separation. In sensitivity tests for the detection of low abundance proteins in the presence of high concentration protein mixtures, as low as 10 fmol/mul (S/N = 10) of a spiked peptide in 1 microg of digested BSA could be detected. In the analysis of a mixture of three digested proteins (BSA, myoglobin, and cytochrome c), more than twice the amino acid sequence coverage was obtained for the microchip LC-MALDI-MS compared to MALDI-MS alone.  相似文献   

20.
A commercial system that is comprised of a CE coupled to an ESI triple quadrupole mass spectrometer was equipped with two capacitively coupled contactless conductivity detectors (C4Ds). The first C4D was positioned inside the original cartridge, and the second C4D was positioned as close as possible to the ESI probe entrance by using a 3D‐printed support. The C4Ds electropherograms were matched to the ESI‐MS electropherogram by correcting their timescales by the factor LT/LD, where LT and LD are the total capillary length and the length until the C4D, respectively. A general approach for method development supporting the simultaneous conductivity and MS detection is discussed, while application examples are introduced. These examples include the use of C4D as a simple device that dismiss the use of an EOF marker, a low‐selectivity detector that continuously provide information about unexpected features of the sample, and even a detector that can be more sensitive than ESI‐MS. The C4D used in this setup proved to have a smaller contribution to the peak broadening than ESI‐MS, which allowed that a C4D, positioned at 12 cm from the inlet of an 80‐cm‐long capillary, could be used to foresee position and shape of the peaks being formed 6.8 times slower at the ESI‐MS electropherogram.  相似文献   