首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A simple, sensitive and specific high‐performance liquid chromatography mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of β‐hydroxy‐β‐methyl butyrate (HMB) in small volumes of rat plasma using warfarin as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. A simple liquid–liquid extraction process was used to extract HMB and IS from rat plasma. The total run time was 3 min and the elution of HMB and IS occurred at 1.48 and 1.75 min respectively; this was achieved with a mobile phase consisting of 0.1% formic acid in a water–acetonitrile mixture (15:85, v/v) at a flow rate of 1.0 mL/min on a Agilent Eclipse XDB C8 (150 × 4.6, 5 µm) column. The developed method was validated in rat plasma with a lower limit of quantitation of 30.0 ng/mL for HMB. A linear response function was established for the range of concentrations 30–4600 ng/mL (r > 0.998) for HMB. The intra‐ and inter‐day precision values for HMB were acceptable as per Food and Drug Administration guidelines. HMB was stable in the battery of stability studies, viz. bench‐top, autosampler freeze–thaw cycles and long‐term stability for 30 days in plasma. The developed assay method was applied to a bioavailability study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
A new method was developed for the quantitation of 3‐α‐hydroxy tibolone, in human plasma, after oral administration of a tablet formulation containing tibolone (2.5 mg). 3‐α‐Hydroxy tibolone was extracted by a liquid–liquid procedure, using cyproterone acetate as internal standard and chlorobutane as extraction solvent. After extraction, samples were submitted to a derivatization step with p‐toluenesulfonyl isocyanate. A mobile phase consisting of acetonitrile and water (72:28 v/v) was used and chromatographic separation was achieved using Agilent XDB C18 column (100 × 4.6 mm i.d.; 5 µm particle size), at 40°C. Mass spectrometric detection was performed using atmospheric pressure chemical ionization in negative mode for 3‐α‐hydroxy tibolone and in positive mode for cyproterone acetate. The fragmentation transitions were m/z 510.2 → m/z 170.1 and m/z 417.0 → m/z 357.1 for 3‐α‐hydroxy tibolone and cyproterone acetate, respectively. Calibration curves were constructed over the range 100–30,000 pg/mL and the method was shown to be specific, precise and accurate, with a mean recovery rate of 94.2% for 3‐α‐hydroxy tibolone. No matrix effect or carry‐over was detected in the samples. The validated method was applied in a pharmacokinetic study with a tibolone formulation in healthy female volunteers. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
A valid method using liquid chromatography coupled with electrospray ionization (ESI) and ion trap mass spectrometry was established for the study of the absorbed components in rat plasma after oral administration of a traditional Chinese medicine (TCM) Shexiang Baoxin pill. The plasma was deproteinated by adding methanol prior to liquid chromatography, in which separation was carried out on a Symmetry C18 column (5 µm, 250 × 4.6 mm). A linear gradient with 0.5% formic acid–water–acetonitrile was used as mobile phase. Mass spectra were acquired in both negative and positive modes. Twenty‐one components including 17 components from Shexiang Baoxin pill and four metabolites were observed from a comprehensive analysis of the chromatography of Shexiang Baoxin pill, controlled plasma and dosed plasma. All of the 17 prototype compounds and three of the metabolites were identified by comparing their retention behaviors and MS and MS/MS spectra with reference compounds and literature data. This study developed an integrated method for screening the bioactive constituents in plasma after oral adminstration of Chinese herbal medicine and provided helpful chemical information for further pharmacology and active mechanism research on TCM. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
γ‐Tocotrienol has attracted much attention owing to its multiple health benefits. This study developed and validated a simple, specific, sensitive and reliable LC/MS/MS method to analyze γ‐tocotrienol in rat plasma. Plasma samples (50 μL) were extracted with internal standard solution (25 ng/mL of itraconazole) in acetonitrile (200 μL) with an average recovery of 44.7% and an average matrix effect of ?2.9%. The separation of γ‐tocotrienol and internal standard from the plasma components was achieved with a Waters XTerra® MS C18 column with acetonitrile–water as mobile phase. Analysis was performed under positive ionization electrospray mass spectrometer via the multiple reaction monitoring. The standard curve was linear over a concentration range of 10–1000 ng/mL with correlation coefficient values >0.997. The method was validated with intra‐ and inter‐day accuracy (relative error) ranging from 1.79 to 9.17% and from 2.16 to 9.66%, respectively, and precision (coefficient of variation) ranged from 1.94 to 9.25% and from 2.37 to 10.08%, respectively. Short‐term stability, freeze–thaw stability and the processed sample stability tests were performed. This method was further applied to analyze γ‐tocotrienol plasma concentrations in rats at various time points after administration of a 2 mg/kg single intravenous dose, and a pharmacokinetic profile was successfully obtained. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
A rapid and sensitive LC–MS/MS method with good accuracy and precision was developed and validated for the pharmacokinetic study of quercetin‐3‐O‐β‐d ‐glucopyranosyl‐7‐O‐β‐d ‐gentiobioside (QGG) in Sprague–Dawley rats. Plasma samples were simply precipitated by methanol and then analyzed by LC–MS/MS. A Venusil® ASB C18 column (2.1 × 50 mm, i.d. 5 μm) was used for separation, with methanol–water (50:50, v/v) as the mobile phase at a flow rate of 300 μL/min. The optimized mass transition ion‐pairs (m/z) for quantitation were 787.3/301.3 for QGG, and 725.3/293.3 for internal standard. The linear range was 7.32–1830 ng/mL with an average correlation coefficient of 0.9992, and the limit of quantification was 7.32 ng/mL. The intra‐ and inter‐day precision and accuracy were less than ±15%. At low, medium and high quality control concentrations, the recovery and matrix effect of the analyte and IS were in the range of 89.06–92.43 and 88.58–97.62%, respectively. The method was applied for the pharmacokinetic study of QGG in Sprague–Dawley rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
A simple, specific, sensitive and rapid LC‐ESI‐MS/MS method has been developed and validated for the quantification of 4‐methylpyrazole in dog plasma using N‐methylnicotinamide‐d4 as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a simple protein precipitation. Chromatographic separation of 4‐methylpyrazole and the IS was performed on a monolithic (Chromolith RP18e) column using an isocratic mobile phase comprising 0.2% formic acid in water and acetonitrile (20:80, v/v) at a flow rate of 1.0 mL/min. Elution of 4‐methylpyrazole and the IS occurred at ~1.60 and 1.56 min, respectively. The total chromatographic run time was 3.2 min. A linear response function was established in the concentration range of 4.96–4955 ng/mL. The intra‐ and inter‐day accuracy and precision were in the ranges 1.81–12.9 and 3.80–11.1%, respectively. This novel method has been applied to a pharmacokinetic study in dogs.  相似文献   

7.
This study is the first to detail the development and validation of a rapid, sensitive and specific LC‐ESI‐MS/MS method for the determination of eriodictyol‐8‐C‐β‐d ‐glucopyranoside (EG) in rat plasma. A simple protein precipitation method was used for plasma sample preparation. Chromatographic separation was successfully achieved on an Agilent Zorbax XDB C18 column (2.1 × 50 mm, 3.5 µm) using a step gradient program with the mobile phase of 0.1% formic acid aqueous solution and acetonitrile with 0.1% formic acid. EG and the internal standard (IS) were detected using an electrospray negative ionization mass spectrometry in the multiple reaction monitoring mode. This method demonstrated good linearity and did not show any endogenous interference with the active compound and IS peaks. The lower limit of quantification of EG was 0.20 ng/mL in 50 μL rat plasma. The average recoveries of EG and IS from rat plasma were both above 80%. The inter‐day precisions (relative standard deviation) of EG determined over 5 days were all within 15%. The present method was successfully applied to a quantification and bioavailability study of EG in rats after intravenous and oral administration. The oral absolute bioavailability of EG in rats was estimated to be 7.71 ± 1.52%. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
Thymosin β4 (Tβ4), its sulfoxide, and thymosin β10 (Tβ10) were detected in human saliva and identified by different strategies based on RP HPLC coupled to electrospray multidimensional IT MS. Tβ4 was almost always detected in whole saliva, its sulfoxide sporadically, Tβ10 rarely. Tβ4 was undetectable in parotid saliva and less concentrated in submandibular/sublingual saliva than in whole saliva. Analysis of gingival crevicular fluid revealed high relative amounts of Tβ4, Tβ4 sulfoxide, and Tβ10 in all the samples. Tβ4 mean concentration was 200 times higher in crevicular fluid (20 μmol/L, N = 9) than in whole saliva (0.1 μmol/L, N = 9). Crevicular fluid concentration of Tβ4 (ca. 5% represented by its sulfoxide) and β10 significantly correlated (r = 0.856; N = 9), and their ratio was about 5. A significant correlation was also observed between Tβ4 concentrations in whole saliva and gingival crevicular fluid (r = 0.738; N = 9). Immunohistochemical analysis of the major salivary glands showed that immunoreactivity for Tβ4 is restricted to ductal cells, with minor degree of focal positivity in some acinar cells. On the whole, results indicate that gingival sulcus is a main, although not the sole, source for oral Tβ4 and Tβ10.  相似文献   

9.
Binding assays for the γ‐aminobutyric acid (GABA) transporter GAT3 can be assumed to significantly facilitate screening for respective inhibitors. As appropriate labeled ligands for this promising drug target are not available so far, we started efforts to set up mass spectrometry‐based binding assays (MS binding assays), for which labeled markers are not required. Therefore, we developed a sensitive and rapid LC‐ESI‐MS/MS quantification method for DDPM‐1007 {(RS)‐1‐[4,4,4‐Tris(4‐methoxyphenyl)but‐2‐en‐1‐yl]piperidine‐3‐carboxylic acid}, one of the most potent GAT3 inhibitors yet known, as a potential GAT3 marker. Using a 50 × 2 mm C8 column in combination with a mobile phase composed of 10 mm ammonium bicarbonate buffer pH 8.0 and acetonitrile (60:40, v/v) at a flow rate of 450 μL/min DDPM‐1007 could be analyzed in the positive multiple reaction monitoring mode [(m/z) 502.5 → 265.4] within a chromatographic cycle time of 3 min. Deuterated DDPM‐1007 [(2H9)DDPM‐1007] was synthesized and employed as internal standard. This way DDPM‐1007 could be quantified in a range from 100 pm to10 nm in the matrix resulting from respective binding experiments without any sample preparation. The established quantification method met the requirements of the FDA guidance for bioanalytical method validation concerning linearity and intra‐ and inter‐batch accuracy. Based on this LC‐ESI‐MS/MS quantification preliminary MS binding assays employing membrane preparations obtained from a stably GAT3 expressing HEK293 cell line and DDPM‐1007 as nonlabeled GAT3 marker could be performed. In these experiments specific binding of DDPM‐1007 at GAT3 could be unambiguously detected. Additionally, the established LC‐MS method provides a suitable analytical tool for further pharmacokinetic characterization of DDPM‐1007, as exemplified for its logD determination. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
A sensitive and reliable GC‐MS method was developed and validated for the simultaneous determination of ascaridole, p‐cymene and α‐terpinene in rat plasma using naphthalene as internal standard. The plasma samples were extracted with ethyl acetate. Chromatographic separation was carried out on a HP‐5MS capillary analytical column (30 m × 0.25 mm, 0.25 µm) and detection was performed on a quadrupole mass spectrometer detector operated under selected ion monitoring mode. The method showed excellent linearity over the investigated concentration range (r > 0.99) with the limit of quantitation down to 50, 10 and 5 ng/mL for ascaridole, p‐cymene and α‐terpinene, respectively. The intra‐day and inter‐day precisions (RSD) were <11.3%, and the accuracy was between 90.7 and 113.8%. The method was successfully applied to investigate the pharmacokinetics of Chenopodium ambrosioides L. following oral administration to rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
A high‐throughput, sensitive, and rugged liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the rapid quantitation of β ‐hydroxy‐β ‐methylbutyrate (HMB) in human plasma has been developed and validated for routine use. The method uses 100 μL of plasma sample and employs protein precipitation with 0.1% formic acid in methanol for the extraction of HMB from plasma. Sample extracts were analyzed using LC–MS/MS technique under negative mode electrospray ionization conditions. A 13C–labeled stable isotope internal standard was used to achieve accurate quantitation. Multiday validation was conducted for precision, accuracy, linearity, selectivity, matrix effect, dilution integrity (2×), extraction recovery, freeze–thaw sample stability (three cycles), benchtop sample stability (6 h and 50 min), autosampler stability (27 h) and frozen storage sample stability (146 days). Linearity was demonstrated between 10 and 500 ng/mL. Inter‐day accuracies and coefficients of variation (CV) were 91.2–98.1 and 3.7–7.8%, respectively. The validated method was proven to be rugged for routine use to quantify endogenous levels of HMB in human plasma obtained from healthy volunteers.  相似文献   

12.
The established analytical method for determining the concentration of dantrolene sodium (Da) in rat tissues by HPLC/MS/MS technique was successfully applied to tissue distribution studies of Da in rats. Tissue homogenate samples were pretreated by protein precipitation with pre‐cooled methanol. Chromatographic separation was achieved on an Acquity HPLC column (Kromat Universil XB‐C18, 2.1 × 150 mm, 3 μm). Mass spectrometry was conducted with an electrospray ionization interface in negative ionization mode and multiple reaction monitoring was used for quantitative analysis. The results showed that Da was rapidly and widely distributed in tissues and reached the maximum concentration within 0.5 h in all tissues after oral administration of Da–hydroxypropyl‐β‐cyclodextrin (DHC). It was then metabolized by liver and finally excreted from kidney,which indicated that DHC inclusion complex has better absorption and higher oral bioavailability than Da. The results also provided evidence for the safety and effectiveness of drug clinical application.  相似文献   

13.
We developed and validated a simple, sensitive, selective and reliable LC–ESI‐MS/MS method for direct quantitation of dropropizine enantiomers namely levodropropizine (LDP) and dextrodropropizine (DDP) in rat plasma without the need for derivatization as per regulatory guidelines. Dropropizine enantiomers and carbamazepine (internal standard) were extracted from 50 μL rat plasma using ethyl acetate. LDP and DDP resolved with good baseline separation (Rs = 4.45) on a Chiralpak IG‐3 column. The mobile phase consisted of methanol with 0.05% diethylamine pumped at a flow rate of 0.5 mL/min. Detection and quantitation were done in multiple reaction monitoring mode following the transitions m/z 237 → 160 and 237 → 194 for dropropizine enantiomers and the internal standard, respectively, in the positive ionization mode. The proposed method provided accurate and reproducible results over the linearity range of 3.23–2022 ng/mL for each enantiomer. The intra‐ and inter‐day precisions were in the ranges of 3.38–13.6 and 5.11–13.8 for LDP and 4.19–11.8 and 8.89–10.1 for DDP. Both LDP and DDP were found to be stable under different stability conditions. The method was successfully used in a stereoselective pharmacokinetic study of dropropizine enantiomers in rats following oral administration of racemate dropropizine at 100 mg/kg. The pharmacokinetic results indicate that the disposition of dropropizine enantiomers is not stereoselective and chiral inversion does not occur in rats.  相似文献   

14.
Caffeine is a mild stimulant with significant potential for abuse, being consumed in larger doses with the widespread availability of energy drinks and by novel routes of administration such as inspired powder, oral sprays and electronic cigarettes. How these recent changes in caffeine consumption affecting caffeine disposition and abuse potential is of growing concern. In the study of caffeine disposition in humans, it is common to only measure the caffeine concentration; however, caffeine's three major metabolites (paraxanthine, theobromine and theophylline) retain central nervous system stimulant activity that may contribute to the overall pharmacological activity and toxicity. Therefore, it would be scientifically more rigorous to measure caffeine and its major metabolites in the evaluation of caffeine disposition in human subjects. Herein, we report a method for the simultaneous quantification of caffeine and its three major metabolites in human plasma by high‐performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC‐ESI‐MS/MS). Human plasma samples were treated by simple protein precipitation and the analytes were separated using a 6 min gradient program. Precision and accuracy were well within in the 15% acceptance range. The simple sample preparation, short runtime, sensitivity and the inclusion of caffeine's major metabolites make this assay methodology optimal for the study of caffeine's pharmacokinetics and pharmacodynamics in human subjects.  相似文献   

15.
Luteoloside is a potential anticarcinogenic component isolated from Lonicera japonica, a traditional Chinese medicine (TCM). This study details the development and validation of a sensitive and accurate HPLC‐ESI‐MS/MS method for the quantification of luteoloside in dog plasma. Sample pretreatment includes simple protein precipitation using methanol–acetonitrile (1:1, v/v). A Phenomenex Gemini C18 column (2.0 × 50 mm, i.d., 3.5 µm) was used to separate luteoloside and internal standard by gradient mode with mobile phase consisting of water containing 0.1% formic acid and methanol containing 0.1% formic acid at a flow rate of 0.40 mL/min with a column temperature of 25°C. The detection was performed by positive ion electrospray ionization (ESI) in multiple reaction monitoring mode. The calibration curves were linear (R > 0.995) over the concentration range 1.0–2000 ng/mL and the lower limit of quantification was 1.0 ng/mL. The intra‐day and inter‐day precisions (RSD) were all <15%, accuracies (RE) were within the range of ±15%, and recoveries were between 85.0 and 115%. The validated HPLC‐ESI‐MS/MS method was successfully applied to determine plasma concentrations of luteoloside after intravenous administration of luteoloside at a dose level of 20 mg/kg. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
This report describes the development and validation of a chromatography/tandem mass spectrometry method for the quantitative determination of pravastatin and its metabolite (3α‐hydroxy pravastatin) in plasma and urine of pregnant patients under treatment with pravastatin, as part of a clinical trial. The method includes a one‐step sample preparation by liquid–liquid extraction. The extraction recovery of the analytes ranged between 93.8 and 99.5% in plasma. The lower limits of quantitation of the analytes in plasma samples were 0.106 ng/mL for pravastatin and 0.105 ng/mL for 3α‐hydroxy pravastatin, while in urine samples they were 19.7 ng/mL for pravastatin and 2.00 ng/mL for 3α‐hydroxy pravastatin. The relative deviation of this method was <10% for intra‐ and interday assays in plasma and urine samples, and the accuracy ranged between 97.2 and 106% in plasma, and between 98.2 and 105% in urine. The method described in this report was successfully utilized for determining the pharmacokinetics of pravastatin in pregnant patients enrolled in a pilot clinical trial for prevention of preeclampsia. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The mass spectra of a series of N‐aryl α,β‐unsaturated γ‐lactams were studied. Besides the molecular ion, the three characteristic fragments such as [M+‐29], [M+‐55], and [M+‐82] were commonly found in a series of N‐Aryl α,β‐unsaturated γ‐lactams in EI/MS. Further more the mechanism for the interpretation of these fragments is also de scribed.  相似文献   

18.
A highly sensitive and specific LC‐ESI‐MS/MS method has been developed and validated for simultaneous quantification of felodipine (FDP) and metoprolol (MPL) in rat plasma (50 μL) using phenacetin as an internal standard (IS) as per the FDA guidelines. Liquid–liquid extraction method was used to extract the analytes and IS from rat plasma. The chromatographic resolution of FDP, MPL and IS was achieved with a mobile phase consisting of 0.2% formic acid in water–acetonitrile (25:75, v/v) with a time program flow gradient on a C18 column. The total chromatographic run time was 4.0 min and the elution of FDP, MPL and IS occurred at 1.05, 2.59 and 1.65 min, respectively. A linear response function was established for the range of concentrations 0.59–1148 and 0.53–991 ng/mL for FDP and MPL, respectively, in rat plasma. The intra‐ and inter‐day accuracy and precision values for FDP and MPL met the acceptance as per FDA guidelines. FDP and MPL were stable in battery of stability studies viz., bench‐top, auto‐sampler and freeze–thaw cycles. The validated assay was applied to a pharmacokinetic study in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
A reversed‐phase high performance liquid chromatography method has been developed and validated for determination and quantitation of the natural sesquiterpene (−)‐α‐bisabolol. Furthermore the application of the method was done by characterization of chitosan milispheres and liposomes entrapping Zanthoxylum tingoassuiba essential oil, which contains appreciable amount of (−)‐α‐bisabolol. A reversed‐phase C18 column and gradient elution was used with the mobile phase composed of (A) acetonitrile–water–phosphoric acid (19:80:1) and (B) acetonitrile. The eluent was pumped at a flow rate of 0.8 mL/min with UV detection at 200 nm. In the range 0.02–0.64 mg/mL the assay showed good linearity (R2 = 0.9999) and specificity for successful identification and quantitation of (−)‐α‐bisabolol in the essential oil without interfering peaks. The method also showed good reproducibility, demonstrating inter‐day and intra‐day precision based on relative standard deviation values (up to 3.03%), accuracy (mean recovery of 100.69% ± 1.05%) and low values of detection and quantitation limits (0.0005 and 0.0016 mg/mL, respectively). The method was also robust for showing a recovery of 98.81% under a change of solvent in standard solutions. The suitability of the method was demonstrated by the successful determination of association efficiency of the (−)‐α‐bisabolol in chitosan milispheres and liposomes. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive and selective liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of β,β‐dimethylacrylshikonin (DASK) in rat whole blood. DASK was pretreated using pre‐column derivatization with 2‐mercaptoethanol followed by liquid–liquid extraction with cyclohexane. Detection was performed on Thermo Finnigan TSQ Quantum triple quadrupole mass spectrometer by selected reaction monitoring mode via electrospray ionization source. The linear range for the determination of DASK spiked in rat whole blood (0.25 mL) was 3–3000 ng/mL. The accuracy was within 9%. Intra‐ and inter‐day precisions were no more than 16.1 and 13.3%, respectively. The validated LC‐MS/MS method was successfully applied to the preliminary pharmacokinetic study in rats. After DASK administration (60 mg/kg, p.o.) in rats, pharmacokinetic parameters were obtained, where the area under the drug concentration–time curve was 2393.7 ± 224.4 ng h/mL and the elimination half‐life was 27.6 ± 5.3 h. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号