首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(15):2974-2991
Abstract

A simple and sensitive spectrophotometric method for the determination of nitrogen dioxide in ambient air and nitrite/nitrate in water and soil samples has been developed. Nitrogen dioxide in air has been fixed as nitrite ion using alkaline sodium arsenite as absorbing medium. The method is based on the reaction of nitrite with aminophenyl benzimidazole in acid medium to form diazonium ion, which is coupled with N‐(1‐naphthyl)ethylenediamine dihydrochloride to form an azo dye with an absorption maximum at 555 nm in aqueous phase. The method obeys Beer's law in the concentration range 0–10 µg of nitrite in 25 ml solution. The molar absorptivity has been found to be 6.3×104 l mol?1 cm?1. The dye can be extracted quantitatively into isoamyl alcohol under alkaline condition and the addition of methanolic hydrochloric acid restores the original dye colour. Beer's law is obeyed in the concentration range 0–2 µg of nitrite with a detection limit of 0.009 µg. The effect of interfering species has been studied and the developed method has been applied to determine trace levels of nitrogen dioxide in ambient air and the results have been compared with the standard method. It is also applied to measure the nitrite/nitrate levels of surface and ground water samples collected from lakes, tube wells as well as soil samples.  相似文献   

2.
Mehmet Akyüz  ?evket Ata 《Talanta》2009,79(3):900-1824
Gas chromatography-mass spectrometry (GC-MS) and liquid chromatography with fluorescence detection (LC-FL) methods have been proposed for the determination of low level nitrite and nitrate in biological, food and environmental samples. The methods include derivatization of aqueous nitrite with 2,3-diaminonaphthalene (DAN), enzymatic reduction of nitrate to nitrite, extraction with toluene and chromatographic analyses of highly fluorescent 2,3-naphthotriazole (NAT) derivative of nitrite by using GC-MS in selected-ion-monitoring (SIM) mode and LC-FL. Nitrite and nitrate ions in solid samples were extracted with 0.5 M aqueous NaOH by sonication. The recoveries of nitrite and nitrate ions based on GC-MS and LC-FL results were 98.40% and 98.10% and the precision of these methods, as indicated by the relative standard deviations (RSDs) were 1.00% for nitrite and 1.20% for nitrate, respectively. The limits of detection of the GC-MS in SIM mode and LC-FL methods based on S/N = 3 were 0.02 and 0.29 pg/ml for nitrite and 0.03 and 0.30 pg/ml for nitrate, respectively.  相似文献   

3.
Gas chromatography–mass spectrometry (GC-MS) method and a liquid chromatography–fluorescence (LC-FL) detection method using experimental design and optimisation approach were improved for the quantitative determination of nitrite and nitrate in biological, food and environmental samples. The obtained recoveries of nitrite and nitrate ions from samples based on both GC-MS and LC-FL results ranged from 98.5% to 98.9% for nitrite and 97.9% to 98.4% for nitrate. The precision of these methods, as indicated by the relative standard deviations (RSDs), was within the range from 2.4% to 3.6% for nitrite and 2.5% to 3.8% for nitrate, respectively. The limits of detection of nitrite and nitrate ions from samples based on GC-MS and LC-FL results ranged from 0.01 to 0.14 ng L?1 for nitrite and 0.02 to 0.71 ng L?1 for nitrate, respectively. The optimised isolation procedure by central composite design was successfully applied to real samples. The results revealed that the proposed procedure combined with GC-MS and LC-FL techniques is more sensitive, reliable and selective compared to the other methods available for the precise determination of trace levels of nitrite and nitrate in biological, food and environmental samples.  相似文献   

4.
In this work, the design of a microfluidic paper-based analytical device (μPAD) for the quantification of nitrate in urine samples was described. Nitrate monitoring is highly relevant due to its association to some diseases and health conditions. The nitrate determination was achieved by combining the selectivity of the nitrate reductase enzymatic reaction with the colorimetric detection of nitrite by the well-known Griess reagent. For the optimization of the nitrate determination μPAD, several variables associated with the design and construction of the device were studied. Furthermore, the interference of the urine matrix was evaluated, and stability studies were performed, under different conditions. The developed μPAD enabled us to obtain a limit of detection of 0.04 mM, a limit of quantification of 0.14 mM and a dynamic concentration range of 0.14–1.0 mM. The designed μPAD proved to be stable for 24 h when stored at room temperature in air or vacuum atmosphere, and 60 days when stored in vacuum at −20 °C. The accuracy of the nitrate μPAD measurements was confirmed by analyzing four certified samples (prepared in synthetic urine) and performing recovery studies using urine samples.  相似文献   

5.
A sensitive flow-injection method for the chemiluminescent determination of ultra-low concentration of nitrate in water is presented. Nitrate is on-line photolytically converted to peroxynitrite by absorption of UV light inside of 60 mm long quartz capillary (i.d. 530 µm, o.d. 720 µm). Peroxynitrite is subsequently determined by the chemiluminescent reaction with luminol. The detection limit of nitrate is 7 × 10?10 M (S/N = 3). The linear range of the method is 2 × 10?9–1 × 10?5 M nitrate. The interference of nitrite is eliminated by its conversion to nitrogen after mixing of sample with a solution of sulfamidic acid. Other common anions do not interfere. The interference of cations is eliminated by passing the sample through a cation-exchange column. The FIA procedure allows analysing of 15 samples per hour. The method was applied to the determination of nitrate in various real water samples. The results are in good agreement with a reference ion chromatographic method.  相似文献   

6.
A simple method for the determination of nitrite and nitrate in human plasma has been developed using CZE with minimal sample preparation. Field‐amplified sample stacking (FASS) was used to achieve submicromolar detection by dilution of the plasma sample with deionized water. In CZE, the separation of nitrite and nitrate was achieved within 10 min without adding EOF modifier. The optimal condition was achieved with 50 mM phosphate buffer at pH 9.3. The ninefold diluted plasma samples were injected hydrodynamically for 40 s into a 60 cm×75 μm id uncoated fused‐silica capillary. The separation voltage was 20 kV (negative potential) and UV detection was performed at 214 nm. The linearity curves for nitrite and nitrate were obtained by the standard addition method. The estimated LODs for nitrite and nitrate in ninefold diluted plasma sample were 0.05 and 0.07 μM, respectively. The LODs for nitrite and nitrate in original plasma samples were 0.45 and 0.63 μM. The intra‐ and inter‐day precisions for both analytes were <2.6% and the recovery ranged between 92.3 and 113.3%. It was found that nitrite was more stable than nitrate in the plasma after the sample preparation. This proposed method was applied to a number of human plasma samples and the measured nitrite and nitrate concentrations in human plasma were consistent with the literature ranges.  相似文献   

7.
In this study, a simple, rapid, and sensitive method for the determination of nitrite (NO2?) in food samples by high‐performance liquid chromatography with fluorescence detection in acidic conditions had been developed. The derivatization of the nitrite with 2,3‐diaminonaphthalene was performed in acidic conditions to yield the highly fluorescent 2,3‐naphthotriazole, which was directly analyzed by high‐performance liquid chromatography with fluorescence detection without adjusting the solution to alkaline. The analysis column was reversed‐phase C8 column. A constant flow rate of 1.0 mL/min was employed using water/acetonitrile as the mobile phase in isocratic mode (70:30, v/v). Fluorescence was monitored with excitation at 375 nm and emission at 415 nm. The standard calibration curves were linear for nitrite in different matrixes in the concentration range of 0–100 μg/L, and the correlation coefficients ranged from 0.9978 to 0.9998. The limits of detection and quantification were in the ranges of 0.012–0.060 and 0.040–0.20 mg/kg, respectively. The recoveries of nitrite from samples spiked at three different concentrations were 74.0–113.2%, and the relative standard deviations of the recovery results (n = 6) were 1.67–10.8%. The proposed method has good repeatability and is very sensitive and simple. It has been successfully used to determine nitrite in foods.  相似文献   

8.
Wu  Anguo  Duan  Tingting  Tang  Dan  Xu  Youhua  Feng  Liang  Zheng  Zhaoguang  Zhu  Jiaxiao  Wang  Rushang  Zhu  Quan 《Chromatographia》2013,76(23):1649-1655

Nitrite and nitrate are main stable products of nitric oxide, a pivotal cellular signaling molecule, in biological fluids. Therefore, accurate measurement of the two ions is profoundly important. Nitrite is difficult to be determined for a larger number of interferences and unstable in the presence of oxygen. In this paper, a simple, cost-effective and accurate HPLC method for the determination of nitrite and nitrate was developed. On the basis of the reaction that nitrite is oxidized rapidly to nitrate with the addition of acidic potassium permanganate, the determination of nitrite and nitrate was achieved by the following strategy: each sample was injected twice for HPLC analysis, i.e. the first injection was to measure nitrate, and the second injection was to measure total nitrate including initial nitrate and the nitrate from the conversion of nitrite with the addition of acid potassium permanganate in the sample. The amount of nitrite can be calculated as difference between injections 2 and 1. The HPLC separation was performed on a reversed phase C18 column for 15 min. The mobile phase consisted of methanol–water (2:98 by volume); the water in the mobile phase contained 0.60 mM phosphate salt (potassium dihydrogen and disodium hydrogen phosphate) and 2.5 mM tetrabutylammonium perchlorate (TBAP). The UV wavelength was set at 210 nm. Additionally, we systemically investigated the effects of the concentration of phosphate salt and TBAP in the mobile phase, the pH of the mobile phase, and the amount of acidic potassium permanganate added to the sample on the separation efficacy. The results showed that the limits of detection (LOD) and the limit of quantitation (LOQ) were 0.075 and 0.25 μM for nitrate (containing the oxidized nitrite), respectively. The linear range was 1–800 μM. This developed approach was successfully applied to assay nitrite/nitrate levels in cell culture medium, cell lysate, rat plasma and urine.

  相似文献   

9.
Nitrite and nitrate are main stable products of nitric oxide, a pivotal cellular signaling molecule, in biological fluids. Therefore, accurate measurement of the two ions is profoundly important. Nitrite is difficult to be determined for a larger number of interferences and unstable in the presence of oxygen. In this paper, a simple, cost-effective and accurate HPLC method for the determination of nitrite and nitrate was developed. On the basis of the reaction that nitrite is oxidized rapidly to nitrate with the addition of acidic potassium permanganate, the determination of nitrite and nitrate was achieved by the following strategy: each sample was injected twice for HPLC analysis, i.e. the first injection was to measure nitrate, and the second injection was to measure total nitrate including initial nitrate and the nitrate from the conversion of nitrite with the addition of acid potassium permanganate in the sample. The amount of nitrite can be calculated as difference between injections 2 and 1. The HPLC separation was performed on a reversed phase C18 column for 15 min. The mobile phase consisted of methanol–water (2:98 by volume); the water in the mobile phase contained 0.60 mM phosphate salt (potassium dihydrogen and disodium hydrogen phosphate) and 2.5 mM tetrabutylammonium perchlorate (TBAP). The UV wavelength was set at 210 nm. Additionally, we systemically investigated the effects of the concentration of phosphate salt and TBAP in the mobile phase, the pH of the mobile phase, and the amount of acidic potassium permanganate added to the sample on the separation efficacy. The results showed that the limits of detection (LOD) and the limit of quantitation (LOQ) were 0.075 and 0.25 μM for nitrate (containing the oxidized nitrite), respectively. The linear range was 1–800 μM. This developed approach was successfully applied to assay nitrite/nitrate levels in cell culture medium, cell lysate, rat plasma and urine.  相似文献   

10.
In this work a new electrochemical sensor based on an Ag-doped zeolite-expanded graphite-epoxy composite electrode (AgZEGE) was evaluated as a novel alternative for the simultaneous quantitative determination of nitrate and nitrite in aqueous solutions. Cyclic voltammetry was used to characterize the electrochemical behavior of the electrode in the presence of individual or mixtures of nitrate and nitrite anions in 0.1 M Na2SO4 supporting electrolyte. Linear dependences of current versus nitrate and nitrite concentrations were obtained for the concentration ranges of 1-10 mM for nitrate and 0.1-1 mM for nitrite using cyclic voltammetry (CV), chronoamperometry (CA), and multiple-pulsed amperometry (MPA) procedures. The comparative assessment of the electrochemical behavior of the individual anions and mixtures of anions on this modified electrode allowed determining the working conditions for the simultaneous detection of the nitrite and nitrate anions. Applying MPA allowed enhancement of the sensitivity for direct and indirect nitrate detection and also for nitrite detection. The proposed sensor was applied in tap water samples spiked with known nitrate and nitrite concentrations and the results were in agreement with those obtained by a comparative spectrophotometric method. This work demonstrates that using multiple-pulse amperometry with the Ag-doped zeolite-expanded graphite-epoxy composite electrode provides a real opportunity for the simultaneous detection of nitrite and nitrate in aqueous solutions.  相似文献   

11.
《Analytical letters》2012,45(5):751-764
Abstract

A simple and efficient FIA method was used with good results to determine nitrite in residual waters and nitrate in natural waters. Nitrite determination is based on the reaction with iodide occurring in acidic medium and biamperometric detection of the formed iodine at two platinum electrodes polarised at a potential of 100 mV. Nitrate is similarly determined after its previous reduction to nitrite in a cadmium column. The method does not need the solution deaeration. However, the calibration graphs present two regions of linearity owing to the catalytic effect of the dissolved oxygen on the iodide oxidation by nitrite.  相似文献   

12.
A rapid, simple miniaturised photometrical method was developed for the determination of nitrate and/or nitrite in freshwater samples. All procedures, including sample buffering, reduction by copperised cadmium granules, colour development and absorbance determination, were completed in a 96-well microplate. The factors governing the nitrate reduction and its recovery were investigated in detail, and the optimised analysing conditions were established. Nitrate was quantitatively reduced by copperised cadmium granules with a high reduction efficiency (96.59 ± 0.96%). The proposed method gave a linear calibration ranging from 0.01 to 1.50 mg L−1 for NO2-N and 0.02 to 1.50 mg L−1 for NO3-N. The detection limits for nitrite and nitrate were 2 and 4 μg L−1, respectively. The proposed method allowed at least 48 samples to be simultaneously analysed in duplicate, with good precision, within 90 min for nitrate and 30 min for nitrite, and was successfully applied to actual freshwater sample analysis with a recovery of 98.02 ± 1.04% for nitrite and 99.72 ± 1.39% for nitrate. This method produced accurate results comparable to standard methods, provided a much higher sample throughput than conventional methods and could be routinely used in actual freshwater sample monitoring.  相似文献   

13.
A membrane filtration procedure for the preconcentration and atomic absorption spectrometric determination of Pb(II), Co(II) and Fe(III) ions in natural water samples has been established. Cellulose nitrate membrane filters (0.45 μm and 47 mm diameter) were used in all experiments. The procedure is based on chelate formation of the analyte metals with 1‐(2‐pyridylazo) 2‐naphtol (PAN) and on retention of the chelates on cellulose nitrate membrane filter. The cellulose nitrate membrane and analyte ions were completely dissolved by 500 μL of nitric acid at 85 °C on a hood and then metal determinations were performed by flame atomic absorption spectrometry. The method was applied to natural water samples for the determination of analyte ions with satisfactory results, e.g., recoveries > 95%, RSD's < 10%.  相似文献   

14.
This study describes the design and optimisation of a field flow system for the in-situ collection and on-line determination of phosphate, nitrate and nitrite by flow injection analysis-spectrophotometry. The method is based on the initial determination of phosphate as its phosphoantimonylmolybdenum blue complex which is then oxidized on-line by nitrite and the decrease in absorbance is monitored at 880 nm. Nitrate is determined as the difference between total and initial nitrite content in a separate flow after reduction to nitrite in a cadmium reductive column. The calibration curves were linear in the range 0–2.00 mg L−1 P-phosphate, 0–10.00 mg L−1 nitrite and 0–7.00 mg L−1 nitrate with correlation coefficients of 0.9979, 0.9993 and 0.9995, respectively. The detection limits, calculated as 3S/N, were 0.15 mg L−1 for P-phosphate, 0.17 mg L−1 for nitrite and 0.09 mg L−1 for nitrate. The reproducibility was below 3.0% (n = 7). Method validation in the analysis of natural water and wastewater samples revealed that it can efficiently be applied to the determination of the target analytes, with recoveries in the range of 92–108%. Correspondence: Athanasios G. Vlessidis, Laboratory of Analytical Chemistry, Department of Chemistry, University of Ioannina, Ioannina 45110, Greece  相似文献   

15.
A simple, sensitive and selective method for the simultaneous determination of nitrite and nitrate in water samples has been developed. The method is based on ion-exchange separation, online photochemical reaction, and luminol chemiluminescence detection. The separation of nitrite and nitrate was achieved using an anion-exchange column with a 20 mM borate buffer (pH 10.0). After the separation, these ions were converted to peroxynitrite by online UV irradiation using a low-pressure mercury lamp and then mixed with a luminol solution prepared with carbonate buffer (pH 10.0). The calibration graphs of the nitrite and nitrate were linear in the range from 2.0 × 10−9 to 2.5 × 10−6 M and 2.0 × 10−8 to 2.5 × 10−5 M, respectively. Since the sensitivity of nitrite was about 10 times higher than that of nitrate, the simultaneous determination of nitrite and nitrate in the water samples could be efficiently achieved. This method was successfully applied to various water samples – river water, pond water, rain water, commercial mineral water, and tap water – with only filtration and dilution steps.  相似文献   

16.
An alternative CE‐(indirect ultraviolet) method for the analysis of inorganic and organic anions in ethylene glycol‐based engine coolants is presented using a BGE with 4 mM pyromellitic acid and 3.4 mM 1,6‐hexamethylene diamine, pH 3. Baseline separation of six inorganic (e.g. nitrite, nitrate, and sulfate) and five organic anions (e.g. acetic and glycolic acid) was achieved. Quantification of 8 out of 11 specified anions was possible in stressed engine coolant samples after simple aqueous dilution. LODs between 0.8 and 15.1 mg/L with RSD values of peak areas between 2.6 and 11.9% were obtained. Some limitations due to matrix effects can be overcome with slight adaptations of the BGE. The flexibility of the method is vital regarding the increasing demands for the composition of engine coolants for pollution reduction.  相似文献   

17.
We describe capillary zone electrophoresis (CZE) for the simultaneous determination of bromide, nitrite and nitrate ions in seawater. Artificial seawater was adopted as the carrier solution to eliminate the interference of high concentrations of salts in seawater. The artificial seawater was free from bromide ion to enable the determination of bromide ion in a sample solution. For the purpose of reversing the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the carrier solution. A 100 microm ID (inside diameter) capillary was used to extend the optical path length. The limits of detection (LODs) for bromide, nitrite, and nitrate ions were 0.46, 0.072, and 0.042 mg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.1, 1.5, and 0.97%. The RSDs of migration time for these ions were 0.61, 0.69, and 0.66%. Artificial seawater samples containing various concentrations of bromide, nitrite, and nitrate ions were analyzed by the method. The error was less than +/-12% even if the concentration ratio of bromide ion to nitrite or nitrate ion was 20-240. The proposed method was applied to the determination of bromide, nitrite, and nitrate ions in seawater samples taken from the surface and the seabed. These ions in other environmental waters such as river water and rainwater samples were also determined by ion chromatography (IC) as well as this method.  相似文献   

18.
《Analytical letters》2012,45(13):2606-2616
Abstract

A simple and sensitive solid‐phase fluorescence quenching method for the determination of trace amounts of nitrite in food samples has been developed. The method is based on that rhodamine B (RhB) which is used as an emission reagent and is included by β‐cyclodextrin polymer(β‐CDP), reacts with nitrite in the presence of iodide to form a nonfluorescence compound in acidic medium. The fluorescence intensity of the RhB‐included β‐CDP was measured in solid phase with excitation and emission wavelengths of 353 and 592 nm, respectively. The fluorescence quenching degree is good linear with the concentration of nitrite over the ranges of 1.0–3.0 µg with a detection limit of 0.04 µg and RSD is 1.2%. The general coexisting ions do not interfere to the reaction of RhB with nitrite. The proposed method has been applied to the determination of trace amount of nitrite in food samples with the recoveries of 102.8% (ham) and 99.0% (sausage), respectively.  相似文献   

19.
The capillary electrophoresis method with direct UV detection is proposed for the determination of nitrite and nitrate in high-salt perchlorate solutions issued from uranium carbide dissolution. The isotachophoretic sample stacking was used to compensate for the perchlorate matrix interference. Simple electrolyte composed of 120 mM formiate buffer, pH 3.8 enabled the nitrate and nitrite determination in the presence of up to 1000-fold excess of perchlorate with 2 μM and 4 μM detection limits for nitrate and nitrite, respectively. The proposed method was applied to the determination of nitrate and nitrite in high-salt non-irradiated uranium carbide dissolution samples.  相似文献   

20.
A recent guideline recommends therapeutic drug monitoring for risperidone, paliperidone and olanzapine, which are frequently used second‐generation antipsychotics. We developed a simple high‐performance liquid chromatography–tandem mass spectrometry coupled with an online solid‐phase extraction method that can be used to measure risperidone, paliperidone and olanzapine using small (40 μL) samples. The analytes were extracted from serum samples automatically pre‐concentrated and purified by C8 (5 μm, 2.1 × 30 mm) solid‐phase extraction cartridges, then chromatographed on an Xbidge™ C18 column (3.5 μm, 100 × 2.1 mm) thermostatted at 30°C with a mobile phase consisting of 70% acetonitrile and 30% ammonium hydroxide 1% solution at an isocratic flow rate of 0.3 mL/min, and detected with tandem mass spectrometry. The assay was validated in the concentration range from 2.5 to 160 ng/mL. Intra‐ and inter‐day precision for all analytes was between 1.1 and 8.2%; method accuracy was between 6.6 and 7.6%. The risperidone and paliperidone assay was compared with a high‐performance liquid chromatography‐ultraviolet assay currently used in our hospital for risperidone and paliperidone therapeutic drug monitoring, and the results of weighted Deming regression analysis showed good agreement. For the olanzapine assay, we compared 20 samples in separate re‐assays on different days; all the relative errors were within the 20% recommended limit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号