首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Enantiomeric separation of d ‐ and l ‐serine on an octadecylsilica column was investigated using (2R)‐2,5‐dioxopyrrolidin‐1‐yl‐2,5,7,8‐tetramethyl‐6‐(tetrahydro‐2H‐pyran‐2‐yloxy)chroman‐2‐carboxylate (R‐NPCA), which was developed for a pre‐column derivatization reagent for electrochemical detection. In addition, (2S)‐2,5‐dioxopyrrolidin‐1‐yl‐2,5,7,8‐tetramethyl‐6‐(tetrahydro‐2H‐pyran‐2‐yloxy)chroman‐2‐carboxylate (S‐NPCA) was newly synthesized from (S)‐(?)‐6‐hydroxy‐2,5,7,8‐tetramethylchroman‐2‐carboxylic acid (Sα‐CA), and the enantiomeric separation of d ‐ and l ‐serine using S‐NPCA was also examined. The enantiomeric separation of d ,l ‐serine was achieved using the R‐ or S‐NPCA as a chiral derivatization reagent, and the elution orders of the enantiomers were reversed between R‐ and S‐NPCA. The elution orders of d ‐ and l ‐serine unexpectedly reversed between the phosphate buffer at pH 4.0 and pH 2.2, both of which were used in the mobile phase. Separation factors obtained using R‐ and S‐NPCA were similar—1.09 and 1.07, respectively. The detection limit was approximately 940 fmol on the column (signal‐to‐noise ratio 3) when the applied voltage was +650 mV. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
A pre‐column derivatization high‐performance liquid chromatography method with diode array detection was developed and validated to determine the total retronecine esters‐type hepatotoxic pyrrolizidine alkaloids (RET‐HPAs) in herbs. The RET‐HPAs reacted with o‐chloranil in methanolic solution heated for 3 h, and an oxidative derivative was produced that could be detected at a maximal absorption of 223 nm. The analysis was performed using a C18 column with an isocratic elution of methanol and aqueous 0.01% triethylamine (adjusted to pH 4 with formic acid), and the detection was carried out with DAD at 223 nm. The validation of the method included linearity, sensitivity, recovery and stability. It showed a good linear regression (r2 > 0.9900) in the range of 2.5–250 µm with a limit of detection (S/N = 3) of 0.5 µm . The method provided desirable repeatability with overall intra‐ and inter‐day variations of less than 4.6%. The obtained recoveries for both of the extraction and derivatization process were between 94.6 and 100.7% (n = 3). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
Acrolein is a major unsaturated aldehyde that is generated during the lipid peroxidation process. The measurement of acrolein in biological samples should be useful to estimate the degree of lipid peroxidation and to evaluate the effect of hazardous properties of acrolein on human health. In this study, a highly sensitive and selective high‐performance liquid chromatography with fluorescence detection method was developed for the determination of acrolein in human serum. The proposed method involves the pre‐column fluorogenic derivatization of acrolein with 1,2‐diamino‐4,5‐dimethoxybenzene (DDB) as a reagent. The fluorescent derivative of acrolein could be detected clearly without any interfering reagent blank peaks because DDB does not have intrinsic fluorescence itself, and the detection limit was 10 nM (signal‐to‐noise ratio = 3). The proposed method could selectively detect acrolein in human serum with a simple protein precipitation treatment. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
We describe a simple, rapid, selective and sensitive HPLC method coupled with fluorescence detection for simultaneous determination of 10 kinds of biogenic amines (BAs: tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, 5‐hydroxytryptamine, tyramine, spermidine, dopamine and spermine). BAs and IS were derivated with dansyl chloride. Fluorescence detection (λex/λem = 340/510 nm) was used. A satisfactory result for method validation was obtained. The assay was shown to be linear over the ranges 0.005–1.0 μg/mL for tryptamine, 2‐phenethylamine and spermidine, 0.025–1.0 μg/mL for putrescine, 0.001–1.0 μg/mL for cadaverine, 0.25–20 μg/mL for histamine, 0.25–10 μg/mL for 5–hydroxytryptamine and dopamine, and 0.01–1.0 μg/mL for tyramine and spermine. The limits of detection and the limits of quantification were 0.3–75.0 ng/mL and 1.0–250.0 ng/mL, respectively. Relative standard deviations were ≤5.14% for intra‐day and ≤6.58% for inter‐day precision. The recoveries of BAs ranged from 79.11 to 114.26% after spiking standard solutions of BAs into a sample at three levels. Seven kinds of BAs were found in rat plasma, and the mean values of tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, spermidine and spermine determined were 52.72 ± 7.34, 11.45 ± 1.56, 162.56 ± 6.26, 312.75 ± 18.11, 1306.50 ± 116.16, 273.89 ± 26.41 and 41.51 ± 2.07 ng/mL, respectively.  相似文献   

5.
A sensitive, reliable and simple HPLC method was developed for the determination of lisinopril in human plasma. The method consists of extraction and clean‐up steps based on magnetic solid‐phase extraction and pre‐column derivatization with a fluorescent reagent. The mobile phase consisted of a mixture of methanol–sodium dihydrogen phosphate (pH 3.0; 0.005 m ; 75:25, v/v). The flow rate was set at 0.7 mL/min. Fluorescence detection was performed at 470nm excitation and 530nm emission wavelengths. Total chromatography run time was 5 min. The average extraction recovery of lisinopril and fluvoxamine (internal standard) was ≥82.8%. The limits of detection and quantification were determined as 1 and 3 ng/mL respectively. The method exhibited a linear calibration line over the concentration range of 3–1000 ng/mL with coefficient of determination (r2) of ≥0.98. The within‐run and between‐run precisions were satisfactory with values of CV of 1.8–12.8% (accuracy from 99.2 to 94.7%) and 2.4–13.7% (accuracy from 99.5 to 92.2%), respectively. These developments led to considerable improvement in method sensitivity and reliability. The method was validated according to the US Food and Drug Administration guidelines. Therefore, it can be considered as a suitable method for determination of lisinopril in plasma samples.  相似文献   

6.
A simple and sensitive method that dose not require derivatization for determining cholestanol has been developed using HPLC with electrochemical detection (HPLC‐ECD). The current peak height was linearly related to the amount of cholestanol injected, ranging from 1 to 200 μM (r = 0.999). The detection limit (S/N = 3) of cholestanol was 0.23 μM (1.2 pmol). Total cholestanol in control human and mouse serum was determined by the present method with a recovery rate of more than 90% and an RSD (n = 5) of less than 7.3%. Further, this method was successfully applied to monitor experimental hypercholestanolemia in mice fed a high‐cholestanol diet, an animal model of cerebrotendinous xanthomatosis (CTX). In conclusion, we found this method to be both simple and useful for the determination of cholestanol in serum, helping in the diagnosis of CTX. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
A selective, sensitive and rapid high‐performance liquid chromatography method with post‐column hydrolysis and fluorescence detection was developed for the simultaneous quantification of acetylsalicylic acid and its metabolite salicylic acid in human plasma. Following the addition of 2‐hydroxy‐3‐methoxybenzoic acid as internal standard and simple protein precipitation with acetonitrile, the analytes were separated on a ProntoSIL 120 C18 ace‐EPS column (150 × 2 mm, 3 µm) protected by a C8 guard column (5 µm). The mobile phase, 10 mm formic acid in water (pH 2.9) and acetonitrile (70:30, v/v), was used at a flow rate of 0.35 mL/min. After on‐line post‐column hydrolysis of acetylsalicylic acid (ASA) to salicylic acid (SA) by addition of alkaline solution, the analytes were measured at 290 nm (λex) and 400 nm (λem). The method was linear in the concentration ranges between 0.05 and 20 ng/μL for both ASA and SA with a lower limit of quantification of 25 pg/μL for SA and 50 pg/μL for ASA. The limit of detection was 15 pg/μL for SA and 32.5 pg/μL for ASA. The analysis of ASA and SA can be carried out within 8 min; therefore this method is suitable for measuring plasma concentrations of salicylates in clinical routine. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
Due to regulation of the use of bisphenol A, several analogs serving as bisphenol A replacements have drawn substantial attention for their adverse health effects. To investigate their occurrence in humans and identify possible pollution sources, it is necessary to develop a sensitive method for total bisphenols detection. Thus, a method based on enzymolysis and liquid‐liquid extraction followed by molecularly imprinted polymer solid‐phase extraction and pre‐column derivatization with high‐performance liquid chromatography and tandem mass spectrometry was proposed. The developed method exhibited superior selectivity and sensitivity. The matrix effect can be eliminated to a great extent. The method detection limits for eight bisphenols were 0.05~0.19 ng/mL. Satisfactory recoveries (71~119%) were obtained by spiking bovine serum at three levels (0.8, 8 and, 20 ng/mL). The method was successfully applied to determine total bisphenols in the serum samples of children. Bisphenol A, bisphenol F, bisphenol S, bisphenol B and bisphenol F were detected with concentrations from below the method detection limit to 1.65, 0.45, 0.79, 2.04 and 0.17 ng/mL, respectively. These results indicate that bisphenol A remains the major pollutant among the studied bisphenols in children, whereas threats from bisphenol A analogs should also be monitored.  相似文献   

9.
Eflornithine (α‐difluoromethylornithine) has been used to treat second‐stage (or meningoencephalitic‐stage) human African trypanosomiasis and currently is under clinical development for cancer prevention. In this study, a new ultraperformance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS)‐based assay was developed and validated for the quantification of eflornithine in rat brain. To improve chromatographic retention and MS detection, eflornithine was derivatized with 6‐aminoquinolyl‐N‐hydroxysuccinimidyl carbamate for 5 min at room temperature prior to injection. Derivatized eflornithine was separated on a reverse‐phase C18 UPLC column with a 6‐min gradient; elution occurred at approximately 1.5 min. Prior to derivatization, eflornithine was reproducibly extracted from rat brain homogenate by methanol protein precipitation (~70% recovery). Derivatized eflornithine was stable in the autosampler (6 °C) for at least 24 h. This new assay had acceptable intra‐ and interday accuracy and precision over a wide dynamic range (5000‐fold) and excellent sensitivity with a lower limit of quantification of 0.1 µm (18 ng/mL) using only 10 μL of rat brain homogenate. The validated eflornithine assay was applied successfully to determine eflornithine distribution in different regions of rat brain in an in situ rat brain perfusion study. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
A new method for glyphosate residue determination in apple has been developed. A SPE cartridge was used to clean up the samples before derivatization. Glyphosate was derivatized with 4‐chloro‐3,5‐dinitrobenzotrifluoride (CNBF) and quantified by reverse ion‐pair liquid chromatography using cetyltrimethylammonium bromide (CTAB) as ion‐pair reagent. In pH 9.5 H3BO3–Na2B4O7 medium, the reaction of glyphosate with CNBF was complete after 30 min at 60°C. The stability of the derivative on exposure to light at room temperature in methanol–water was demonstrated. The labeled glyphosate was separated on a Kromasil C18 column (250×4.6 mm, 5 μm) at room temperature and UV detection was applied at 360 nm. Separation was achieved within 15 min in gradient elution mode. The correlation coefficient for the method was 0.9998 at concentrations ranging from 0.1 to 50 μg/g. The calculated recoveries for glyphosate in apple were from 86.00 to 99.55%, and the relative standard deviations (n = 6) were from 1.43 to 6.32. The limit of detection was 0.01 μg/g for glyphosate in apple.  相似文献   

11.
The therapeutic drug monitoring of paroxetine could be used to optimize the pharmacological treatment of depressed patients. A simple and sensitive high‐performance liquid chromatography procedure was developed for the determination of paroxetine in serum. After simple pretreatment of serum (50 μL) with acetonitrile and o‐phthalaldehyde, paroxetine was derivatized with 4‐(5,6‐dimethoxy‐2‐phthalimidinyl)‐2‐methoxyphenylsulfonyl chloride at 70°C for 20 min in borate buffer (0.1 mol/L, pH 8.0) to produce a fluorescent product. The derivative was separated on a reversed‐phase column at 40°C for stepwise elution with (A) acetic acid (10 mmol/L) and (B) acetonitrile. The flow rate was 1.0 mL/min. The fluorescence intensity was monitored at excitation and emission wavelengths of 320 and 400 nm, respectively. The within‐day and day‐to‐day relative standard deviations were 3.0–3.4 and 2.7–8.3%, respectively. The detection limit of paroxetine was 8.3 fmol at a signal‐to‐noise ratio of 3. As the proposed method that only requires a small quantity of serum (50 μL) is simple, sensitive and reproducible, it would be useful for clinical and biochemical research as well as drug monitoring. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A new, simple and sensitive pre-column fluorescence derivatization high-performance liquid chromatographic method for the determination of the oxidative DNA stress marker, 8-oxo-7,8-dihydro-2'-deoxyguanosine, was developed. Solid-phase extraction using an Oasis HLB cartridge avoided troublesome sample preparation steps, interference from charged species and frequent and essential electrode maintenance in electrochemical procedures. 8-Oxo-7,8-dihydro-2'-deoxyguanosine and other guanine compounds were selectively derivatized with glyoxal reagents (phenylglyoxal, 3,4-methylenedioxyglyoxal, 2-naphtylglyoxal and 6-methoxynaphthylglyoxal) at 40-60 degrees C. Derivatization with 6-methoxynaphthylglyoxal at 40 degrees C for 30 min gave the strongest fluorescence product. The fluorescence derivatives from reaction with 6-methoxynaphthylglyoxal were separated on a Capcell Pak C18 SG 120A column (4.6 mm i.d. x 150 mm, 5 microm) with acetonitrile-5 mM phosphate buffer (pH 6.0; 3:7, v/v) as mobile phase. The detection wavelength of the fluorescence derivative of 8-oxo-7,8-dihydro-2'-deoxyguanosine was lambda(ex) 400 nm and lambda(em) 510 nm. The detection limit of 8-oxo-7,8-dihydro-2'-deoxyguanosine was 1 ng/mL using 50 mL of urine. The calibration graphs were linear up to 30 microg/mL for 8-oxo-7,8-dihydro-2'-deoxyguanosine. The relative standard deviation of 20 ng/mL of 8-oxo-7,8-dihydro-2'-deoxyguanosine was 7.0%. The proposed method was compared with the enzymatic ELISA 8-oxo-7,8-dihydro-2'-deoxyguanosine analysis method (8-OH-dG Check, JaICA, Shizuoka, Japan). The correlation coefficient was 0.79 (n = 20) and y = 0.85x + 5.34. The proposed method was applied to the monitoring of 8-oxo-7,8-dihydro-2'-deoxyguanosine in urine from male heavy smokers.  相似文献   

13.
A method of analysis for 3‐methoxypterostilbene [trans‐3,3′5‐trimethoxy‐4′hydroxystilbene] in biological fluids is necessary to study pharmacokinetics. A novel and simple high‐performance liquid chromatographic method was developed for the determination of 3‐methoxypterostilbene in rat serum and urine. The internal standard, pinosylvin, was added to 0.1 mL serum or urine (serum proteins were precipitated with cold acetonitrile at ?20°C). Separation was achieved with a Phenomenex® C18 (2) (5 µm, 250 × 4.60 mm) column with ultraviolet detection at 327 nm. The calibration curves in both matrices were linear ranging from 0.05 to 100 µg/mL, and the mean extraction efficiency was >99%. Precision of the assay for both matrices was <12% (RSD) and was within 13% for all points on the calibration curve. The limit of quantification for this method was 0.05 µg/mL. The assay was successfully applied to a preliminary study of 3‐methoxypterostilbene pharmacokinetics in a rat. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
A method for tryptophan analysis in bee pollen and royal jelly was developed using HPLC with fluorescence detection. To determine the free tryptophan in bee pollen and royal jelly, ultrasonic extraction was performed using water (pH 6.3)–acetonitrile (10:1, v/v) as extraction solvent. While determining the total tryptophan in these bee products, the method involves alkaline hydrolysis of the proteins with 4 mol/L sodium hydroxide at 110°C for 20 h under anaerobic conditions. The operating conditions for the HPLC analysis were: Symmetry C18 column (4.6 × 250 mm, 5 µm), 0.1% trifluoroacetic acid–methanol (75:25, v/v) as the mobile phase at a flow rate of 1.0 mL/min at 30°C. The fluorescence detector was operated at an excitation wavelength of 280 nm and an emission wavelength of 340 nm. A linear response (r> 0.9998) was obtained in the range 0.0625–5.0 µg/mL. The method was successfully applied to the determination of the free and total tryptophan contents in bee pollens, which were 0.069 ± 0.003 and 2.693 ± 0.476 mg/g, respectively, while only the total tryptophan was detected in royal jelly, with a content of 1.743 ± 0.066 mg/g. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
Chiral analysis of dl ‐amino acids was achieved by micellar electrokinetic chromatography coupled with UV‐excited fluorescence detection. The fluorescent reagent (+)‐1‐(9‐fluorenyl)ethyl chloroformate was employed as chiral amino acid derivatizing agent and sodium dodecyl sulfate served as pseudo‐stationary phase for separating the formed amino acid diastereomers. Sensitive analysis of (+)‐1‐(9‐fluorenyl)ethyl chloroformate‐amino acids was achieved applying a xenon‐mercury lamp for ultraviolet excitation, and a spectrograph and charge‐coupled device for wavelength‐resolved emission detection. Applying signal integration over a 30 nm emission wavelength interval, signal‐to‐noise ratios for derivatized amino acids were up to 23 times higher as obtained using a standard photomultiplier for detection. The background electrolyte composition (electrolyte, pH, sodium dodecyl sulfate concentration, and organic solvent) was studied in order to attain optimal chemo‐ and enantioseparation. Enantioseparation of 12 proteinogenic dl ‐amino acids was achieved with chiral resolutions between 1.2 and 7.9, and detection limits for most derivatized amino acids in the 13–60 nM range (injected concentration). Linearity (coefficients of determination > 0.985) and peak‐area and migration‐time repeatabilities (relative standard deviations lower than 2.6 and 1.9%, respectively) were satisfactory. The employed fluorescence detection system provided up to 100‐times better signal‐to‐noise ratios for (+)‐1‐(9‐fluorenyl)ethyl chloroformate‐amino acids than ultraviolet absorbance detection, showing good potential for d ‐amino acid analysis.  相似文献   

16.
A rapid, sensitive, and reliable ultra‐performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6‐aminoquinolyl‐carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C18 column with Acetonitrile–acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5–1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples.  相似文献   

17.
A simple and sensitive method based on the combination of derivatization and high‐performance liquid chromatography with ultraviolet and fluorimetric detection was developed for the simultaneous determination of octreotide and gabexate mesylate metabolite in human pancreatic juice samples. Parameters of the derivatization procedure affecting extraction efficiency were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.1–15 µg/mL for octreotide and 0.20‐15 µg/mL for gabexate mesylate metabolite. Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The limits of detection were 0.025 and 0.05, respectively, for octreotide and gabexate mesylate metabolite. This paper reports the validation of a quantitative high performance liquid chromatography–photodiode array–fluorescence (HPLC‐PDA‐FL) method for the simultaneous analysis of octreotide and gabexate mesylate metabolite in pancreatic juice by protein precipitation using zinc sulfate–methanol–acetonitrile containing the derivatizing reagent, 4‐fluoro‐7‐nitro‐[2,1,3]‐benzoxadiazole (NBD‐F). Derivatized products of octreotide and gabexate mesylate metabolite were separated on a Luna C18 column (4.6 × 250 mm; 5 µm particle size) using a gradient with a run time of 36 min, without further purification. The method was validated over the concentration ranges 0.1–15 and 0.2–15 µg/mL for octreotide and gabexate mesylate metabolite, respectively, in human pancreatic juice. Biphalin and methyl‐p‐hydroxybenzoate were used as the internal standards. This method was successfully utilized to support clinical studies in humans. The results from assay validations show that the method is selective, sensitive and robust. The limit of quantification of the method was 0.1 µg/mL for octreotide and 0.2 µg/mL for gabexate mesylate metabolite, and matrix matched standard curves showed a good linearity up to 15 µg/mL. In the entire analytical range the intra‐ and inter‐day precision (RSD%) values were respectively ≤5.9% and ≤3.1% for octreotide and ≤2.0% and ≤3.9% for gabexate mesylate metabolite. For both analytes the intra‐ and inter‐day accuracy (bias) values ranged respectively from ?6.8 to –2.5% and from ?4.6 to ?5.7%. This method utilizes derivatization with NBD‐F and provides adequate sensitivity for both drugs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
The purine metabolic pathway has been implicated in neurodegeneration and neuroprotection. High‐performance liquid chromatography (HPLC) is widely used to determine purines and metabolites. However, methods for analysis of multiple purines in a single analysis have not been standardized, especially in brain tissue. We report the development and validation of a reversed‐phase HPLC method combining electrochemical and UV detection after a short gradient run to measure seven purine metabolites (adenosine, guanosine, inosine, guanine, hypoxanthine, xanthine and urate) from the entire purine metabolic pathway. The limit of detection (LoD) for each analyte was determined. The LoD using UV absorption was 0.001 mg/dL for hypoxanthine (Hyp), inosine (Ino), guanosine (Guo) and adenosine (Ado), and those using coulometric electrodes were 0.001 mg/dL for guanine (Gua), 0.0001 mg/dL for urate (UA) and 0.0005 mg/dL for xanthine (Xan). The intra‐ and inter‐day coefficient of variance was generally <8%. Using this method, we determined basal levels of these metabolites in mouse brain and serum, as well as in post‐mortem human brain. Peak identities were confirmed by enzyme degradation. Spike recovery was performed to assess accuracy. All recoveries fell within 80–120%. Our HPLC method provides a sensitive, rapid, reproducible and low‐cost method for determining multiple purine metabolites in a single analysis in serum and brain specimens. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A new pre‐column derivative high‐performance liquid chromatography (HPLC) method for determination of d ‐glucose with 3‐O‐methyl‐d ‐glucose (3‐OMG) as the internal standard was developed and validated in order to study the gluconeogenesis in HepG2 cells. Samples were derivatized with 1‐phenyl‐3‐methy‐5‐pyrazolone at 70°C for 50 min. Glucose and 3‐OMG were extracted by liquid–liquid extraction and separated on a YMC‐Triart C18 column, with a gradient mobile phase composed of acetonitrile and 20 mm ammonium acetate solution containing 0.09% tri‐ethylamine at a flow rate of 1.0 mL/min. The eluate were detected using a UV detector at 250 nm. The assay was linear over the range 0.39–25 μm (R2 = 0.9997, n = 5) and the lower limit of quantitation was 0.39 μm (0.070 mg/mL). Intra‐ and inter‐day precision and accuracy were <15% and within ±3%, respectively. After validation, the HPLC method was applied to investigate the gluconeogenesis in Dulbecco's modified Eagle medium (DMEM) cultured HepG2 cells. Glucose concentration was determined to be about 1–2.5 μm in this gluconeogenesis assay. In conclusion, this method has been shown to determine small amounts of glucose in DMEM successfully, with lower limit of quantitation and better sensitivity when compared with common commercial glucose assay kits. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
The potent phosphodiesterase 4 inhibitor ASP3258 contains a carboxylic acid moiety and a naphthyridine ring and is a novel therapeutic agent for asthma and chronic obstructive pulmonary disease. To support the drug development of ASP3258, we developed and validated a simple method for its determination in rat plasma. Following the addition of the analog AS1406604‐00 as an internal standard, plasma samples were processed using C18‐bonded solid‐phase extraction cartridges under acidic conditions and injected into a high‐performance liquid chromatography system with fluorescence detection. Chromatographic separation was achieved on a Shiseido Capcell Pak C18 UG120 column (3.0 × 150 mm, 5 µm) with a mobile phase consisting of acetonitrile–0.5% acetic acid (50:50, v/v). HPLC eluent was monitored with a fluorescence detector set at a wavelength of 315 nm for excitation and 365 nm for emission. The calibration curve was linear over a range of 2.5–250 ng/mL. Validation data demonstrated that the method is selective, sensitive and accurate. In addition, the present method was successfully applied to rat plasma samples from a pharmacokinetic study. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号