首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The objective of this study was to compare the pharmacokinetic parameters of zaltoprofen and those of its sodium salt in rats. Zaltoprofen, a potent non‐steroidal anti‐inflammatory agent, was virtually insoluble in water, but its sodium salt had excellent water solubility. To investigate the effect of aqueous solubility differences upon their pharmacokinetic parameters, minicapsules containing the drug powders were administrated orally to rats, and blood samples were taken via the common carotid artery. A column‐switching high‐performance liquid chromatographic analytical procedure was developed and validated for the quantitation of zaltoprofen in rat plasma samples. Our study demonstrated that the time required to reach maximum plasma concentration (Tmax) of zaltoprofen sodium was significantly reduced and its maximum plasma concentration (Cmax) was increased 1.5‐fold, relative to the values for zaltoprofen. It is anticipated that the sodium salt of zaltoprofen will allow the rapid onset of the drug's action in the treatment of inflammatory diseases. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
A sequential online extraction, clean‐up and separation system for the determination of betaine, l ‐carnitine and choline in human urine using column‐switching ion chromatography with nonsuppressed conductivity detection was developed in this work. A self‐packed pretreatment column (50 × 4.6 mm, i.d.) was used for the extraction and clean‐up of betaine, l ‐carnitine and choline. The separation was achieved using self‐packed cationic exchange column (150 × 4.6 mm, i.d.), followed by nonsuppressed conductivity detection. Under optimized experimental conditions, the developed method presented good analytical performance, with excellent linearity in the range of 0.60–100 μg mL−1 for betaine, 0.75–100 μg mL−1 for l ‐carnitine and 0.50–100 μg mL−1 for choline, with all correlation coefficients (R2) >0.99 in urine. The limits of detection were 0.15 μg mL−1 for betaine, 0.20 μg mL−1 for l ‐carnitine and 0.09 μg mL−1 for choline. The intra‐ and inter‐day accuracy and precision for all quality controls were within ±10.32 and ±9.05%, respectively. Satisfactory recovery was observed between 92.8 and 102.0%. The validated method was successfully applied to the detection of urinary samples from 10 healthy people. The values detected in human urine using the proposed method showed good agreement with the measurement reported previously.  相似文献   

3.
A novel online column‐switching chiral high‐performance liquid chromatography method was developed and validated for the simultaneous determination of naftopidil (NAF) and its O‐desmethyl metabolites (DMN) enantiomers in rat feces. Direct and multiple injections of supernatant from rat feces homogenate were allowed through the column‐switching system. Analyte extraction was performed on the Capcell Pak mixed‐functional column by acetonitrile–phosphate buffer (pH 7.4; 10 mm ; 8:92, v/v) flowing at 1 mL/min. Separation of NAF and DMN enantiomers was achieved on the Chiralpak IA column by methanol–acetonitrile–acetate buffer (pH 5.3; 5 mm ; 45:33:22, v/v/v) flowing at 0.5 mL/min. The analytes were measured with a fluorescence detector at 290 nm (λex) and 340 nm (λem). The validated method showed a good linearity [22.5–15,000 ng/mL for (+)‐/(?)‐NAF; 35–25,000 ng/mL for (+)‐/(?)‐DMN] and the lowest limits of quantification for NAF and DMN enantiomers were 22.5 and 35 ng/mL, respectively. Both intra‐ and inter‐day variations were <10%. The assay was successfully applied to the fecal excretion of NAF and DMN enantiomers in rat after single oral administration of (±)‐NAF. Nonstereoselective excretion of (+)‐ and (?)‐NAF was found in feces, while stereoselective excretion of (+)‐ and (?)‐DMN was observed with higher excretion levels of (+)‐DMN, indicating that there may exist stereoselective metabolism for NAF enantiomers. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
Lysosomal storage disorders comprise a group of rare genetic diseases in which a deficit of specific hydrolases leads to the storage of undegraded substrates in lysosomes. Impaired enzyme activities can be assessed by MS/MS quantification of the reaction products obtained after incubation with specific substrates. In this study, a column‐switching HPLC‐MS/MS method for multiplex screening in dried blood spot of the lysosomal enzymes activities was developed. Mucopolysaccharidosis type I, Fabry, Gaucher, Krabbe, Niemann–Pick A/B and Pompe diseases were simultaneously assayed. Dried blood spots were incubated with substrates and internal standards; thereafter, supernatants were collected with minor manipulations. Samples were injected, trapped into an online perfusion column and, by a six‐port valve, switched online through the C18 analytical column to perform separation of metabolites followed by MS/MS analysis. A total of 1136 de‐identified newborn screening samples were analyzed to determine references for enzymes activity values. As positive controls, we analyzed dried blood spots from three patients with Pompe, one with Fabry, one with Krabbe disease and two with MPS I, and in all cases the enzyme activities were below the cutoff values measured for newborns, except for an MPS I patient after successful hematopoietic stem cell transplantation. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
A column‐switching liquid chromatography/electrospray ionization tandem mass spectrometry to determine paclitaxel and its metabolites, 6α‐hydroxypaclitaxel and p‐3′‐hydroxypaclitaxel, in human plasma was developed. The analytical system had a Shim‐Pack MAYI‐ODS (10 × 4.6 mm i.d.) trapping column with deproteinization ability that concentrates analytes and removes water‐soluble components. This method covered a linearity range of 5–5000 ng/mL of concentrations in plasma for paclitaxel, a range of 0.87–870 ng/mL for 6α‐hydroxypaclitaxel and a range of 0.87–435 ng/mL for p‐3′‐hydroxypaclitaxel. The intra‐day precision and inter‐day precision of analysis were less than 11.1%, and the accuracy was within ±14.4% at concentrations of 5, 50, 500 and 5000 ng/mL for paclitaxel, 0.87, 8.7, 87 and 870 ng/mL for 6α‐hydroxypaclitaxel, and 0.87, 8.7, 87 and 435 ng/mL for p‐3′‐hydroxypaclitaxel. The total run time was 30 min. Our method was successfully applied to clinical pharmacokinetic investigation. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
Lansoprazole, a selective proton pump inhibitor, has a chiral benzimidazole sulfoxide structure and is used for the treatment of gastric acid hypersecretory related diseases. To investigate its stereoselective pharmacokinetics, a column‐switching liquid chromatography with tandem mass spectrometry method was developed for the determination of lansoprazole enantiomers in dog plasma using (+)‐pantoprazole as an internal standard. After a simple protein precipitation procedure with acetonitrile, matrix components left behind after sample preparation were further eliminated from the sample by reversed‐phase chromatography on a C18 column. The fluent was fed to a chiral column for the separation of lansoprazole enantiomers. Baseline separation of lansoprazole enantiomers was achieved on a Chiralcel OZ‐RH column using acetonitrile/0.1% formic acid in water (35:65, v/v) as the mobile phase at 40°C. The linearity of the calibration curves ranged from 3 to 800 ng/mL for each enantiomer. Intra‐ and inter‐day precisions ranged from 2.1 to 7.3% with an accuracy of ±1.7% for (+)‐lansoprazole, and from 1.6 to 6.9% with an accuracy of ±3.5% for (–)‐lansoprazole, respectively. The validated method was successfully applied for the stereoselective pharmacokinetic study of lansoprazole in beagle dog after intravenous infusion.  相似文献   

7.
The application of ion chromatography with the single pump cycling‐column‐switching technique was described for the analysis of trace inorganic anions in weak acid salts within a single run. Due to the hydrogen ions provided by an anion suppressor electrolyzing water, weak acid anions could be transformed into weak acids, existing as molecules, after passing through the suppressor. Therefore, an anion suppressor and ion‐exclusion column were adopted to achieve on‐line matrix elimination of weak acid anions with high concentration for the analysis of trace inorganic anions in weak acid salts. A series of standard solutions consisting of target anions of various concentrations from 0.005 to 10 mg/L were analyzed, with correlation coefficients r ≥ 0.9990. The limits of detection were in the range of 0.67 to 1.51 μg/L, based on the signal‐to‐noise ratio of 3 and a 25 μL injection volume. Relative standard deviations for retention time, peak area, and peak height were all less than 2.01%. A spiking study was performed with satisfactory recoveries between 90.3 and 104.4% for all anions. The chromatographic system was successfully applied to the analysis of trace inorganic anions in five weak acid salts.  相似文献   

8.
A simple method for the determination of betaine, l ‐carnitine, and choline in human urine was developed based on column‐switching ion chromatography coupled with nonsuppressed conductivity detection by using a self‐packed column. A pretreatment column (50 mm × 4.6 mm, id) packed with poly(glycidyl methacrylate‐divinylbenzene) microspheres was used for the extraction and cleanup of analytes. Chromatographic separation was achieved within 10 min on a cationic exchange column (150 mm × 4.6 mm, id) using maleic anhydride modified poly(glycidyl methacrylate‐divinylbenzene) as the particles for packing. The detection was performed by ion chromatography with nonsuppressed conductivity detection. Parameters including column‐switching time, eluent type, flow rates of eluent, and interfering effects were optimized. Linearity (r 2 ≥ 0.99) was obtained for the concentration range of 0.50–100, 0.75–100, and 0.25–100 μg/mL for betaine, l ‐carnitine, and choline, respectively. Detection limits were 0.12, 0.20, and 0.05 μg/mL for betaine, l ‐carnitine, and choline, respectively. The intra‐ and interday accuracy and precision for all quality controls were within ±10.11%. Satisfactory recovery was observed between 92.5 and 105.0%. The validated method was successfully applied for the determination of betaine, l ‐carnitine, and choline in urine samples from healthy people.  相似文献   

9.
The levels of kynurenic acid, an endogenous antagonist of α7 nicotinic acetylcholine and N‐methyl‐D ‐aspartate receptors, were measured in microdialysis samples obtained from the prefrontal cortices of rats using column‐switching high‐performance liquid chromatography with fluorescence detection. When the perfusate was constantly infused at a rate of 1.0 μ/min, the in vitro recovery of kynurenic acid through the dialysis membrane was approximately 20.4%, and the precision was within 1.31%. Endogenous kynurenic acid in the microdialysis sample was clearly detected using column‐switching high‐performance liquid chromatography. As an application study, N‐acetyl‐L ‐aspartic acid, an endogenous metabolite and precursor of N‐acetyl‐L ‐aspartyl‐L ‐glutamic acid, which is an agonist of metabotropic glutamate receptors, was infused for 120 min through the microdialysis probe. The kynurenic acid level significantly increased during the infusion of N‐acetyl‐L ‐aspartic acid, suggesting that kynurenic acid might have some association with N‐acetyl‐L ‐aspartic acid in vivo. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
An automated analyzer for vancomycin in rat plasma by column-switching high-performance liquid chromatography (HPLC) with UV detection was developed. The method includes in-line extraction of vancomycin by ion-exchange cartridge column and a separation on a reversed-phase column with UV detection at 215 nm. Plasma samples were diluted by mobile phase solution and directly injected to HPLC. Vancomycin was quantitatively recovered from rat plasma samples. The separation was completed within 15 min. The calibration curve was linear over the range from 0.5 to 100 microg/mL with the detection and quantification limits of 0.5 microg/mL (2.5 ng on column; signal-to-noise ratio = 3). The values of precision in intra- and inter-day assays (n = 3) were less than 1.92 and 3.69%, respectively. This method does not require time-consuming pre-treatment and is suitable for the routine assay of plasma samples.  相似文献   

11.
An effective column‐switching counter‐current chromatography (CCC) protocol combining stepwise elution mode was successfully developed for simultaneous and preparative separation of anti‐oxidative components from ethyl acetate extract of traditional Chinese herbal medicine Rubia cordifolia. The column‐switching CCC system was interfaced by a commercial low‐pressure six‐port switching valve equipped with a sample loop, allowing large volume introduction from the first dimension (1st‐D) to the second dimension (2nd‐D). Moreover, to extend the polarity window, three biphasic liquid systems composed of n‐hexane/ethyl acetate/methanol/water (1:2:1:2, 2:3:2:3, 5:6:5:6 v/v) were employed using stepwise elution mode in the 1st‐D. By valve switching technique the whole interested region of 1st‐D could be introduced to second dimension for further separation with the solvent system 5:5:4:6 v/v. Using the present column‐switching CCC protocol, 500 mg of crude R. cordifolia extract were separated, producing milligram‐amounts of four anti‐oxidative components over 90% pure. Structures of purified compounds were identified by 1H and 13C NMR.  相似文献   

12.
A simple and sensitive high‐performance liquid chromatographic (HPLC) method was developed for determination of amrubicin and its metabolite amrubicinol in human plasma. After protein precipitation with methanol without evaporation procedure, large volume samples were injected and separated by two monolithic columns with a guard column. The mobile phase consisted of tetrahydrofuran–dioxane–water (containing 2.3 mM acetic acid and 4 mM sodium 1‐octanesulfonate; 2:6:15, v/v/v). Wavelengths of fluorescence detection were set at 480 nm for excitation and 550 nm for detection. Under these conditions, linearity was confirmed in the 2.5–5000 ng/mL concentration range of both compounds. The intra‐ and inter‐day precision and intra‐ and inter‐day accuracy for both compounds were less than 10%. The method was successfully applied to a clinical pharmacokinetic study of amrubicin and amrubicinol in cancer patients. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A rapid and sensitive reversed‐phase high‐performance liquid chromatographic (RP‐HPLC) method was developed to investigate pharmacokinetics of columbianadin, one of the main bioactive constituents in the roots of Angelica pubescens f. biserrata, in rat plasma after intravenous administration to rats at two doses of 10 and 20 mg/kg. The method involves a plasma clean‐up step using liquid–liquid extraction by diethyl ether, followed by RP‐HPLC separation and detection. Separation of columbianadin was performed on an analytical Diamonsil? ODS C18 column, with a mobile phase of MeOH–H2O (85 : 15, v/v) at a flow‐rate of 1.0 mL/min, and UV detection was set at 325 nm. The retention time of columbianadin and scoparone (internal standard) was 6.7 and 3.5 min, respectively. The calibration curve was linear over the range of 0.2–20.0 μg/mL (r2 = 0.9986) in rat plasma. The lower limits of detection and quantification were 0.05 and 0.1 μg/mL, respectively. The extraction recovery from plasma was in the range of 81.61–89.93%. The intra‐ and inter‐day precisions (relative standard deviation) were between 1.01 and 9.33%, with accuracies ranging from 89.76 to 109.22%. The results indicated that the method established was suitable for the determination and pharmacokinetic study of columbianadin in rat plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
A simple and sensitive column‐switching HPLC‐UV method was developed for the simultaneous determination of aripiprazole, a novel atypical antipsychotic drug, and its active metabolite, dehydroaripiprazole in human plasma. Aripiprazole, its active metabolite and 7‐[5‐[4‐(3‐chloro‐2‐methylphenyl)‐1‐piperazinyl]pentyloxy]‐3,4‐dihydro‐2(1H)‐quinolinone (OPC‐14558) as an internal standard were extracted from 1 mL of plasma using a mixture of chloroform/n‐heptane (3:7, v/v), and the extract was injected into a column I (TSK BSA‐ODS/S precolumn, 5 μm) for cleanup and column II (C18 STR ODS‐II analytical column, 5 μm) for separation. Peaks were detected with an UV detector set at a wavelength of 254 nm, and the total time for chromatographic separation was ~20 min. Mean absolute recoveries were 74.0 and 74.7% for aripiprazole and dehydroaripiprazole, respectively. Intra‐ and inter‐day CVs were less than 7.5 and 7.1% for aripiprazole concentrations ranging from 2 to 600 ng/mL, and 9.2 and 4.5% for dehydroaripiprazole concentrations ranging from 2 to 160 ng/mL. The validated concentration ranges for this method were 1–500 ng/mL and the limits of detection were 0.5 ng/mL for both aripiprazole and dehydroaripiprazole. This method was applied to pharmacokinetic study in human volunteers and patients taking aripiprazole.  相似文献   

15.
Sildenafil is a selective inhibitor of phosphodiesterase type 5 enzyme. A simple and sensitive LC‐MS assay was developed to determine the concentration of sildenafil in human plasma. Sildenafil and omeprazole (internal standard) were extracted from the plasma with diethyl ether. The extract was evaporated under nitrogen and the residue was constituted with ACN and injected onto Novapak C18 column (75×3.9 mm, 4 μm). The mobile phase consisted of 90% ACN plus 10% ammonium acetate (20 mM) containing 0.02% formic acid and was delivered isocratically at a flow rate of 0.2 mL/min. Sildenafil and omeprazole were monitored using a positive electrospray mode with single‐ion recording set at m/z 475 and 346, respectively, which are consistent with [M+H]+ molecular ions, and the run time was less than 5 min. The detection limit of sildenafil was 0.5 ng/mL, and the calibration curve was linear between 0.5 and 2000 ng/mL (R2>0.99). Within‐ and between‐day coefficients of variation were less than 7%. This method has been successfully used to measure sildenafil plasma concentrations in a beagle dog model following an oral administration of the drug.  相似文献   

16.
17.
A simple, accurate and selective column‐switching high‐performance liquid chromatography (HPLC) method was developed and validated for simultaneous quantification of six beta ‐blockers (metoprolol, timolol, bisoprolol, propranolol, carvedilol and nebivolol), three of their metabolites (α ‐hydroxy metoprolol, N‐ desisopropyl propranolol and 4′‐hydroxy carvedilol 4‐HCAR), three antipsychotics (olanzapine, clozapine and quetiapine) and three of their metabolites (N‐ desmethyl olanzapine, N‐ desmethyl clozapine and N‐ desalkyl quetiapine) in human serum. After pretreatment on a Merck LiChrospher RP‐4 ADS column (25 μm), drugs were separated on a Phenomenex Gemini Phenyl Hexyl 110 A column (250 × 4.6 mm, 5 μm) using a gradient mixture of acetonitrile and potassium dihydrogen phosphate buffer pH 3.1 (containing 10% methanol) as a mobile phase at a flow rate of 1 mL/min. The total analysis time was 40 min. For detection of the analytes, four different UV wavelengths were used: 215, 226, 242 and 299 nm. The method was validated according to the guidelines of the Society of Toxicology and Forensic Chemistry in terms of selectivity, linearity, accuracy, precision and stability and successfully applied for the analysis of the 15 described analytes in human serum.  相似文献   

18.
A rapid and simple reverse‐phase high‐performance liquid chromatography (RP‐HPLC) was developed and validated for the quantification of kirenol in rat plasma after oral administration. Kirenol and darutoside (internal standard, IS) were extracted from rat plasma using Cleanert™ C18 solid‐phase extraction (SPE) cartridge. Analysis of the extraction was performed on a Thermo ODS‐2 Hypersil C18 reversed‐phase column with a gradient eluent composed of acetonitrile and 0.1% phosphoric acid. The flow rate was 1.0 mL/min and the detection wavelength was set at 215 nm. The calibration curve was linear over the range of 9.756–133.333 µg/mL (r2 = 0.9991) in rat plasma. The lower limits of detection and quantification were 2.857 and 9.756 µg/mL, respectively. The intra‐ and inter‐day precisions (relative standard deviation, RSD) were between 2.24 and 4.46%, with accuracies ranging from 91.80 to 102.74%. The extraction recovery ranged from 98.16 to 107.62% with RSD less than 4.81%. Stability studies showed that kirenol was stable in preparation and analytical process. The present method was successfully applied to the pharmacokinetic study of kirenol in male Sprague–Dawley rats after oral administration at a dose of 50 mg/kg. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
A sensitive HPLC method was developed and validated for the determination of sildenafil concentrations in rat plasma (200 μL) using a liquid–liquid extraction procedure and paroxetine as an internal standard. In order to eliminate interferences and improve the peak shape, a back‐extraction into an acidic solution was utilized. Chromatographic separation was achieved on a cyanopropyl bonded‐phase column with a mobile phase composed of 50 m m potassium dihydrogen phosphate buffer (pH 4.5) and acetonitrile (75:25, v/v), pumped at the flow rate of 1 mL/min. A UV detector was set at 230 nm. A calibration curve was constructed within a concentration range from 10 to 1500 ng/mL. The limit of detection was 5 ng/mL. The inter‐ and intra‐day precisions of the assay were in the ranges 2.91–7.33 and 2.61–6.18%, respectively, and the accuracies for inter‐ and intra‐day runs were within 0.14–3.92 and 0.44–2.96%, respectively. The recovery of sildenafil was 85.22 ± 4.54%. Tests confirmed the stability of sildenafil in plasma during three freeze–thaw cycles and during long‐term storage at ?20 and ?80°C for up to 2 months. The proposed method was successfully applied to a pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
Dimethylacetamide (DMA) is a solvent used in the preparation of intravenous busulfan, an alkylating agent used in blood or marrow transplantation. DMA may contribute to hepatic toxicity, so it is important to monitor its clearance. The aim of this study was to develop an HPLC‐UV assay for measurement of DMA in human plasma. After precipitation of plasma proteins with acetonitrile followed by dilution (1:4) with water, the extract was injected onto the HPLC and detected at 195 nm. Separation was performed using a Cogent‐HPS 5 μm C18 column (250 × 4.6 mm) preceded by a Brownlee 7 μm RP18, pre‐column (1.5 cm × 3.2 mm). The mobile phase was 25 mm sodium phosphate buffer (pH 3), containing 2.5% (v /v) acetonitrile and 0.0005% (v /v) sodium‐octyl‐sulfonate. Using a flow rate of 1 mL/min, the retention times of DMA and the internal standard (IS), 2‐chloroacetamide, were 9.5 and 3.5 min, respectively. Peak area ratio (DMA:IS) was a linear function of concentration from 1 to 1000 μg/mL. There was excellent intraday precision (<5% for 5–700 μg/mL DMA), accuracy (<3% deviation from the true concentration) and recovery (74–98%). The limits of detection and quantification were 1 and 5 μg/mL, respectively. In eight children who received intravenous busulfan, DMA concentrations ranged from 110 to 438 μg/mL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号