首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Urinary concentrations of 5-aminolaevulinic acid (ALA) and porphobilinogen (PBG) are elevated in patients with acute hepatic porphyrias, especially during acute attacks. Current assays require lengthy sample pre-treatment and derivatisation steps. We report here a rapid, sensitive and specific hydrophilic interaction liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, for the direct and simultaneous quantitation of ALA and PBG in urine following simple dilution with acetonitrile and centrifugation prior to injection. ALA and PBG were detected using selected reaction monitoring mode, following positive electrospray ionisation. Urine samples (N?=?46) from active and latent mutation-confirmed acute hepatic porphyria patients and normal subjects (N?=?45) were analysed and the results compared with those of a commercially available spectrophotometric method. The validated calibration range was 3-3000?μmol/L for ALA and 2-2000?μmol/L for PBG. For both analytes, imprecision (relative standard deviation) was less than 5% and accuracy (percentage nominal concentrations) was between 88 and 109%. The lower limit of quantitation was 0.1 μmol/L for both analytes. The calculated LC-MS/MS and spectrophotometric results from patient samples compared well [Pearson correlation (r2) of 0.99 and 0.95, for ALA and PBG, respectively]. The method was successfully applied to the measurement of ALA and PBG in urine samples for the screening, biochemical diagnosis and treatment monitoring of patients with acute hepatic porphyrias.  相似文献   

2.
We document the presence of a previously unknown species in the urine of patients with acute intermittent porphyria (AIP). The compound was fully characterised by liquid chromatography tandem mass spectrometry. Interpretation of both full spectrum acquisition and product ion spectra acquired in positive and negative ionisation modes by quadrupole time of flight MS allowed for the identification of a condensation product arising from porphobilinogen (PBG, increased in the urine of AIP patients) and indolyl‐3‐acryloylglycine (IAG, derived from indolylacrylic acid and present in human urine). The structure was unequivocally confirmed through comparison between the selected reaction monitoring chromatograms obtained from the urinary species and the condensation product qualitatively synthesised in the laboratory. Owing to the large amounts of both PBG and IAG in urine of AIP patients, the possible ex vivo formation of PBG‐IAG in urine samples was evaluated. The product was spontaneously formed at room temperature, at 4 °C and even during storage at ?20 °C when spiking a control sample with PBG. A positive correlation was found between PBG and PBG‐IAG in samples collected from AIP patients. However, no correlation was found between PBG‐IAG and IAG. Purified PBG‐IAG did not form the characteristic chromogen after application of p‐dimethylaminobenzaldehyde in HCl, thus suggesting that the current techniques used to measure PBG in urine of AIP patients based on Ehlrich's reaction do not detect this newly characterised PBG‐IAG fraction. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
A simple HPLC method has been developed to measure imatinib and N‐desmethylimatinib (norimatinib) in plasma or serum at concentrations attained during therapy. Adaptation of this method to LC‐MS/MS also allows dasatinib assay. A small sample volume (100 μL HPLC‐UV, 50 μL LC‐MS/MS) is required and analysis time is <5 min in each case. Detection was by UV (270 nm) or selective reaction monitoring (two transitions per analyte) tandem mass spectrometry. Assay calibration was linear (0.05–10 mg/L imatinib, 0.01–2.0 mg/L norimatinib and 1–200 µg/L dasatinib), with acceptable accuracy (86–114%) and precision (<14% RSD) for both methods. A comparison between whole blood and plasma confirmed that plasma is the preferred sample for imatinib and norimatinib assay. For dasatinib, although whole blood concentrations were slightly higher, plasma is still the preferred sample. Despite considerable variation in the (median, range) plasma imatinib and norimatinib concentrations in patient samples [1.66 (0.02–4.96) and 0.32 (0.01–0.99) mg/L, respectively, N = 104], plasma imatinib was >1 mg/L (suggested target for response) in all but one sample from patients achieving complete molecular response. As to dasatinib, the median (range) plasma dasatinib concentration was 13 (2‐143) µg/L (N = 33). More observations are needed to properly assess the potential role of therapeutic drug monitoring in guiding treatment with dasatinib. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
Carbamazepine is an antiepileptic drug widely used for the treatment of epilepsy. In the National Institute of Neurology, monitoring has been performed using the technique chemiluminescent microparticle immunoassay (CMIA) in an automated way during the last five years. The aim of this study was to develop a simple and rapid HPLC analytical method coupled to DAD‐UV detection for the determination of plasma concentrations of carbamazepine and compare its feasibility with those used in routine analysis. The developed HPLC method was fully validated and the applicability of the proposed method was verified through the analysis of plasma samples of patients and later compared with the quantification of the same plasma samples with the CMIA method. The limit of quantification obtained was 0.5 μg/mL. The mean value for recovery was 99.05% and the coefficient of variation (CV) was 5.6%. The precision and accuracy of this method were within the acceptable limits; inter‐ and intraday CV values were <10%. The correlation between the CMIA method and the developed HPLC method was very good (r ≈ 0.999). A Bland–Altman plot showed no significant bias between the results. The HPLC‐DAD method may be an alternative to determine and monitoring the carbamazepine levels in human plasma or serum. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
A simple, sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated to determine the concentrations of 7‐hydroxymitragynine in rat plasma. Following a single‐step liquid–liquid extraction of plasma samples using chloroform, 7‐hydroxymitragynine and the internal standard (tryptoline) were separated on an Acquity UPLCTM BEH C18 (1.7 µm, 2.1 × 50 mm) column using an isocratic elution at a flow rate of 0.2 mL/min. The mobile phase consisted of 0.1% acetic acid in water and 0.1% acetic acid in acetonitrile (10:90, v/v). The run time was 2.5 min. The analysis was carried out under the multiple reaction‐monitoring mode using positive electrospray ionization. Protonated ions [M + H]+ and their respective product ions were monitored at the following transitions: 415 → 190 for 7‐hydroxymitragynine and 173 → 144 for the internal standard. The calibration curve was linear over the range of 10–4000 ng/mL (r2 = 0.999) with a lower limit of quantification of 10 ng/mL. The extraction recoveries ranged from 62.0 to 67.3% at concentrations of 20, 600 and 3200 ng/mL). Intra‐ and inter‐day assay precisions (relative standard deviation) were <15% and the accuracy was within 96.5–104.0%. This validated method was successfully applied to quantify 7‐hydroxymitragynine in rat plasma following intravenous administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
The major metabolite of duloxetine is a glucuronide conjugate of 4‐hydroxy duloxetine (4‐HD). However, interestingly, there have been no reports determining concentrations of 4‐HD and no fully validated method has been established for measuring duloxetine and 4‐HD in rat plasma. We developed a method for the simultaneous quantification of duloxetine and its metabolite in rat plasma using high‐performance liquid chromatography tandem mass spectrometry. Duloxetine and 4‐HD were analyzed on a reverse‐phase C18 analytical column after protein precipitation of the plasma sample with methanol, using carbamazepine as an internal standard. The isocratic mobile phase of 5 mm ammonium acetate–methanol (4:6, v/v) was eluted at 0.4 mL/min. Quantification was performed on a triple‐quadrupole mass spectrometer using electrospray ionization, and the ion transition monitored in selective reaction monitoring mode. The coefficient of variation for assay precision was <18.0%, and the accuracy was 84.0–118.0%. This method was successfully used to measure the concentrations of duloxetine and its metabolite in plasma following the oral administration of a single 40 mg/kg dose in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
A simple and sensitive gas chromatography–electron ionization–mass spectrometry (GC‐EI‐MS) method using dried plasma spot testing cards was developed for determination of valproic acid and gabapentin concentrations in human plasma from patients receiving in‐home medical care. We have proposed that a simple, easy and dry sampling method is suitable for in‐home medical patients for therapeutic drug monitoring. Therefore, in the present study, we used recently developed commercially available easy handling cards: Whatman FTA DMPK‐A and Bond Elut DMS. In‐home medical care patients can collect plasma using these simple kits. The spots of plasma on the cards were extracted into methanol and then evaporated to dryness. The residues were trimethylsilylated using N‐methyl‐N‐trimethylsilyltrifluoroacetamide. For GC‐EI‐MS analysis, the calibration curves on both cards were linear from 10 to 200 µg/mL for valproic acid, and from 0.5 to 10 µg/mL for gabapentin. Intra‐ and interday precisions in plasma were both ≤13.0% (coefficient of variation), and the accuracy was between 87.9 and 112% for both cards within the calibration curves. The limits of quantification were 10 µg/mL for valproic acid and 0.5 µg/mL for gabapentin on both cards. We believe that the present method will be useful for in‐home medical care. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
Therapeutic drug monitoring may be crucial in selected clinical conditions for the management of HIV infection. In recent years, new antiretrovirals have been introduced and in particular elvitegravir (EVG) is now recommended for first‐line and simplification treatment as well as dolutegravir (DTG) and rilpivirine (RPV). The aim of this study was to develop and validate a high‐performance liquid chromatography–ultraviolet (HPLC‐UV) method for determining EVG and new antiretrovirals DTG and RPV in human plasma. Solid‐phase extraction was applied to a 600 μL plasma sample. Chromatographic separation of the three drugs and internal standard was achieved with a gradient of acetonitrile and phosphate buffer on a C18 reverse‐phase analytical column with a 20 min analytical run time. EVG and DTG were detected at 265 nm and RPV at 290 nm. Mean intra‐ and inter‐day precisions were < 10%; the mean accuracy was <15%. Extraction recovery ranged between 105 and 82% for the drugs analyzed. Calibration curves were optimized according to the expected ranges of drug concentrations in patients; the coefficient of determination was >0.997 for all drugs. This method allows for monitoring EVG, DTG and RPV in the plasma of HIV‐positive patients using HPLC‐UV.  相似文献   

9.
A simple sample treatment procedure and sensitive liquid chromatography–tandem mass spectrometry method were developed for the simultaneous quantification of the concentrations of human immunodeficiency virus‐1 integrase strand transfer inhibitors – raltegravir, dolutegravir and elvitegravir – in human plasma and cerebrospinal fluid (CSF). Plasma and CSF samples (20 μL each) were deproteinized with acetonitrile. Raltegravir‐d3 was used as the internal standard. Chromatographic separation was achieved on an XBridge C18 column (50 × 2.1 mm i.d., particle size 3.5 μm) using acetonitrile–water (7:3, v/v) containing 0.1% formic acid as the mobile phase at a flow rate of 0.2 mL/min. The run time was 5 min. Calibration curves for all three drugs were linear in the range 5–1500 ng/mL for plasma and 1–200 ng/mL for CSF. The intra‐ and inter‐day precision and accuracy of all three drugs in plasma were coefficient of variation (CV) <12.9% and 100.0 ± 12.2%, respectively, while those in CSF were CV <12.3% and 100.0 ± 7.9%, respectively. Successful validation under the same LC–MS/MS conditions for both plasma and CSF indicates this analytical method is useful for monitoring the levels of these integrase strand transfer inhibitors in the management of treatment of HIV‐1 carriers.  相似文献   

10.
A simultaneous, selective, sensitive and rapid liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of gefitinib, erlotinib and afatinib in 250 μL samples of human blood plasma. Diluted plasma samples were extracted using a liquid‐phase extraction procedure with tert‐butyl methyl ether. The three drugs were separated by high‐performance liquid chromatography using a C18 column and an isocratic mobile phase running at a flow rate of 0.2 mL/min for 5 min. The drugs were detected using a tandem mass spectrometer with electrospray ionization using imatinib as an internal standard. Calibration curves were generated over the linear concentration range of 0.05–100 nm in plasma with a lower limit of quantification of 0.01 or 0.05 nm for all compounds. Finally, the validated method was applied to a clinical pharmacokinetic study in patients with nonsmall‐cell lung cancer (NSCLC) following the oral administration of afatinib. These results indicate that this method is suitable for assessing the risks and benefits of chemotherapy in patients with NSCLC and is useful for therapeutic drug monitoring for NSCLC treatment. As far as we know, this is the first report on LC‐MS/MS method for the simultaneous quantification of NSCLC tyrosine kinase inhibitor plasma concentrations including afatinib. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
A capillary zone electrophoresis/electrospray ionisation mass spectrometry (CZE/ESI-MS) method has been developed for the separation and detection of 5-aminolaevulinic acid (ALA) and porphobilinogen (PBG). Capillaries were 70 cm long with an inner diameter of 75 micrometer and outer diameter of 375 micrometer. The buffer used was aqueous ammonium acetate (50mM, pH 5.2) with a co-axial 'make-up' flow of methanol/aqueous 0.1% formic acid (1:1 v/v) at a flowrate of 6 microL/min. A voltage of 20 kV was used for CZE and an ESI voltage of 3.5 kV. Full scan data was acquired over the range m/z 100-500 in positive ion mode, from which selected ion electropherograms were extracted; at m/z 132 for the protonated molecular ion of ALA and m/z 210 for the methylenepyrrolenine fragment ion of PBG. The protonated molecular ion of PBG, m/z 227, was found to be too facile to monitor, easily losing ammonia in the electrospray source and better sensitivity was achieved by monitoring the resulting fragment ion. The detection limits were circa 100 attomoles of ALA and 10 attomoles of PBG at a signal-to-noise ratio (S/N) better than 10, providing sufficient sensitivity for clinical use and offering advantages over existing techniques.  相似文献   

12.
The therapeutic drug monitoring of paroxetine could be used to optimize the pharmacological treatment of depressed patients. A simple and sensitive high‐performance liquid chromatography procedure was developed for the determination of paroxetine in serum. After simple pretreatment of serum (50 μL) with acetonitrile and o‐phthalaldehyde, paroxetine was derivatized with 4‐(5,6‐dimethoxy‐2‐phthalimidinyl)‐2‐methoxyphenylsulfonyl chloride at 70°C for 20 min in borate buffer (0.1 mol/L, pH 8.0) to produce a fluorescent product. The derivative was separated on a reversed‐phase column at 40°C for stepwise elution with (A) acetic acid (10 mmol/L) and (B) acetonitrile. The flow rate was 1.0 mL/min. The fluorescence intensity was monitored at excitation and emission wavelengths of 320 and 400 nm, respectively. The within‐day and day‐to‐day relative standard deviations were 3.0–3.4 and 2.7–8.3%, respectively. The detection limit of paroxetine was 8.3 fmol at a signal‐to‐noise ratio of 3. As the proposed method that only requires a small quantity of serum (50 μL) is simple, sensitive and reproducible, it would be useful for clinical and biochemical research as well as drug monitoring. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
An ultra‐high‐performance liquid chromatography–tandem mass spectrometry (UHPLC‐MS/MS) method for the analysis of cefazolin and cefalothin in human plasma (total and unbound), urine and peritoneal dialysate has been developed and validated. Total plasma concentrations are measured following protein precipitation and are suitable for the concentration range of 1–500 µg/mL. Unbound concentrations are measured from ultra‐filtered plasma acquired using Centrifree® devices and are suitable for the concentration range of 0.1–500 µg/mL for cefazolin and 1–500 µg/mL for cefalothin. The urine method is suitable for a concentration range of 0.1–20 mg/mL for cefazolin and 0.2–20 mg/mL for cefalothin. Peritoneal dialysate concentrations are measured using direct injection, and are suitable for the concentration range of 0.2–100 µg/mL for both cefazolin and cefalothin. The cefazolin and cefalothin plasma (total and unbound), urine and peritoneal dialysate results are reported for recovery, inter‐assay precision and accuracy, and the lower limit of quantification, linearity, stability and matrix effects, with all results meeting acceptance criteria. The method was used successfully in a pilot pharmacokinetic study with patients with peritoneal dialysis‐associated peritonitis, receiving either intraperitoneal cefazolin or cefalothin. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
A simple, sensitive and specific high‐performance liquid chromatography mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of β‐hydroxy‐β‐methyl butyrate (HMB) in small volumes of rat plasma using warfarin as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. A simple liquid–liquid extraction process was used to extract HMB and IS from rat plasma. The total run time was 3 min and the elution of HMB and IS occurred at 1.48 and 1.75 min respectively; this was achieved with a mobile phase consisting of 0.1% formic acid in a water–acetonitrile mixture (15:85, v/v) at a flow rate of 1.0 mL/min on a Agilent Eclipse XDB C8 (150 × 4.6, 5 µm) column. The developed method was validated in rat plasma with a lower limit of quantitation of 30.0 ng/mL for HMB. A linear response function was established for the range of concentrations 30–4600 ng/mL (r > 0.998) for HMB. The intra‐ and inter‐day precision values for HMB were acceptable as per Food and Drug Administration guidelines. HMB was stable in the battery of stability studies, viz. bench‐top, autosampler freeze–thaw cycles and long‐term stability for 30 days in plasma. The developed assay method was applied to a bioavailability study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
A sensitive and reliable GC‐MS method was developed and validated for the simultaneous determination of ascaridole, p‐cymene and α‐terpinene in rat plasma using naphthalene as internal standard. The plasma samples were extracted with ethyl acetate. Chromatographic separation was carried out on a HP‐5MS capillary analytical column (30 m × 0.25 mm, 0.25 µm) and detection was performed on a quadrupole mass spectrometer detector operated under selected ion monitoring mode. The method showed excellent linearity over the investigated concentration range (r > 0.99) with the limit of quantitation down to 50, 10 and 5 ng/mL for ascaridole, p‐cymene and α‐terpinene, respectively. The intra‐day and inter‐day precisions (RSD) were <11.3%, and the accuracy was between 90.7 and 113.8%. The method was successfully applied to investigate the pharmacokinetics of Chenopodium ambrosioides L. following oral administration to rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
A reliable high‐throughput ultra‐high performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated for oleanolic acid (OA) determination in rat plasma and liver tissue using glycyrrhetic acid as the internal standard (IS). Plasma and liver homogenate samples were prepared using solid‐phase extraction. Chromatographic separation was achieved on a C18 column using an isocratic mobile phase system. The detection was performed by multiple reaction monitoring mode via positive electrospray ionization interface. The calibration curves showed good linearity (R2 > 0.9997) within the tested concentration ranges. The lower limit of quantification for plasma and liver tissue was ≤0.75 ng/mL. The intra‐ and inter‐day precision and accuracy deviations were within ±15% in plasma and liver tissue. The mean extraction recoveries ranged from 80.8 to 87.0%. In addition, the carryover, matrix effect, stability and robustness involved in the method were also validated. The method was successfully applied to the plasma and hepatic pharmacokinetics of OA after oral administration to rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
Levetiracetam is an antiepileptic drug for the treatment of psychiatric patients. In this study, a selective, straightforward, and rapid online heart‐cutting liquid chromatography method was developed for the therapeutic drug monitoring of levetiracetam. This method allows for the determination of levetiracetam in human plasma without complex sample preparation. The mobile phases consisted of 30 mM aq. orthophosphoric acid solution/methanol (70:30) at a flow rate of 1 mL/min for the first system and 10 mM aq. orthophosphoric acid solution/methanol (55:45) at a flow rate of 1 mL/min for the second system. The first separation was carried out on a GL Sciences Intersil ODS‐3 column (4.6 mm × 150 mm, 3 µm) and the second separation was carried out on a Restek Ultra PFPP column (4.6 mm × 150 mm, 5 µm). The detection was carried out at 205 nm for both systems. The method was validated for selectivity and linearity, which were in the 6–60 µg/mL range. Intra‐ and interassay accuracies were <112.6%, and the intra‐ and interassay precisions were <6.4% for all quality control samples. The lower limit of quantitation was 6 µg/mL. The developed method was successfully applied for therapeutic drug monitoring of plasma samples from patients.  相似文献   

18.
The anticancer drug capecitabine and its metabolites [including the active metabolite 5‐fluorouracil (5‐FU)] display high pharmacokinetic inter‐patient variability. Such variability, which may lead to treatment failure or toxicity, could need drug concentration measurement to individualize dosing regimen. However, usual assay methods are often long and fastidious. A simultaneous and cost‐effective method was thus developed for the determination of the concentrations of these compounds in human plasma. Compounds were extracted via a classic liquid–liquid extraction. Chromatographic analysis was performed on a C18 reverse phase column with detection by atmosphere pressure chemical ionization LC‐MS/MS. Our method allows a good chromatographic separation of the compounds and was fully validated following Food and Drug Administration (FDA) recommendations (good selectivity, no carry‐over, linearity of the calibration curves without weighting, deviations from nominal concentrations of standard samples lower than 15%, intra‐ and inter‐assay precision and accuracy lower than 15%). Recovery and stability were also acceptable following the FDA guidelines. A matrix effect impairing the determination of 5‐FU was avoided by using a stable isotopic derivative of 5‐FU as internal standard. Interestingly, this method allows detection of TetraHydroUridine, an inhibitor of ex vivo degradation of metabolites, which is essential for the stability, the adequate conditioning of blood samples and for good laboratory practice, essential in routine determination. This method seems usable to routinely determine concentrations of capecitabine and its metabolites in blood and may be helpful in further studies aiming at performing therapeutic drug monitoring. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
In this study, we developed a method for the determination of PF‐04620110 (2‐{(1r,4r)‐4‐[4‐(4‐amino‐5‐oxo‐7,8‐dihydropyrimido[5,4‐f][1,4]oxazepin‐6(5H)‐yl)phenyl]cyclohexyl}acetic acid), a novel diacylglycerol acyltransferase 1 (DGAT‐1) inhibitor, in rat plasma and validated it using liquid chromatography–tandem mass spectrometry (LC‐MS/MS). Rat plasma samples were processed following a protein precipitation method by using acetonitrile and were then injected into an LC‐MS/MS system for quantification. PF‐04620110 and imipramine (internal standard) were separated using a Hypersil Gold C18 column, with a mixture of acetonitrile and 10 mm ammonium formate (90:10, v/v) as the mobile phase. The ion transitions monitored in positive‐ion mode [M + H]+ of multiple‐reaction monitoring were m/z 397.0 → 260.2 for PF‐04620110 and m/z 280.8 → 86.0 for imipramine. The detector response was specific and linear for PF‐04620110 at concentrations within the range 0.05–50 µg/mL and the signal‐to‐noise ratios for the samples were ≥10. The intra‐ and inter‐day precision and accuracy of the method matched the acceptance criteria for assay validation. PF‐04620110 was stable under various processing and/or handling conditions. PF‐04620110 concentrations in the rat plasma samples could be measured up to 24 h after intravenous or oral administration of PF‐04620110, suggesting that the assay is useful for pharmacokinetic studies in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
A rapid and sensitive liquid chromatography–isotope dilution tandem mass spectrometry method was developed and validated for quantification of itraconazole (ITZ) and its active metabolite hydroxyitraconazole (OH‐ITZ ) in human plasma. The plasma samples were extracted with tert‐butyl methyl ether and two isotope‐labeled internal standards (D5‐itraconazole and D5‐hydroxyitraconazole) were used. The chromatographic separation was performed on a Capcell Pak C18 MG III (100 × 2 mm, 5 µm, Shiseido). The protonated ions of analytes were detected in positive ionization in multiple reaction monitoring mode. The plasma method has a lower limit of quantification of 1 ng/mL with a linearity range of 1–500 ng/mL for ITZ and OH‐ITZ using 100 µL of plasma. The recoveries of the method were found to be 69.47–71.98% for ITZ and 75.68–82.52% for OH‐ITZ. The intra‐ and inter‐batch precision was less than 11% for all quality control samples at concentrations of 2.5, 200 and 400 ng/mL. These results indicate that the method was efficient with a short run time (4.5 min) and acceptable accuracy, precision and sensitivity.The validated method was successfully applied to analysis of human plasma samples in pharmacokinetics study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号