首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fluorescent coordination polymers have drawn extensive attention in sensing applications. Herein, we report a carbazole-based one-dimensional coordination polymer [CdL(H2O)(DMF)2]·DMF ( CdL , H2L = 9H-carbazole-2,7-dicarboxylic acid, DMF = N,N-dimethylformamide). In CdL , each Cd2+ ion is four-bridged by carboxylates, which is further linked by the carbazole units to form a one-dimensional Cd–O–C chains along the c-axis. CdL displays high water stability in the pH range of 3–10. Luminescence experiments indicate that CdL could selectively detect Fe3+ during the concentration range of 0–0.1 mm in water with a Ksv of 8022 m −1 and picric acid (PA) within the concentration range of 0–0.05 mm in methanol solution with a Ksv of 17948 m −1 respectively. The above results reveal that CdL can be applied as a multiresponse luminescence sensor for selectively sensing for Fe3+ in water and PA in methanol solution.  相似文献   

2.
3.
A new fluorescent sensor capable of sensing Cr3+ has been synthesized. Complexing with Cr3+ triggers the formation of a highly fluorescent ring-open form which is pink in color. The sensor shows extremely high fluorescence enhancement upon complexation with Cr3+ and it can be used as a ‘naked eye’ sensor. Binding of Cr3+ was found to be reversible as the pink color disappears with excess EDTA.  相似文献   

4.
A pyrene based chemosensor was designed and synthesized. The pyrene fluorophore was connected with a pyridine unit through a Schiff base structure to give the sensor (L). L was tested with a variety of metal ions and exhibited high colorimetric selectivities for Cu2+ and Fe3+ over other ions. Upon binding with Cu2+ or Fe3+, L showed an obvious optical color change from colorless to pink for Cu2+ or orange for Fe3+ over a wide pH range from 3 to 12. Moreover, the fluorescence of L at 370 nm decreased sharply after bonding with Fe3+, while other metal ions including Cu2+ had no apparent interference. Thus, using such single chemosensor, Cu2+ and Fe3+ can be detected independently with high selectivity and sensitivity. The limits of detection toward Cu2+ and Fe3+ were 8.5 and 2.0 μM, respectively. DFT calculation results also proved the formation of stable coordination complexes and the phenomenon of fluorescence quenching by Fe3+. Furthermore, L was also successfully used as a bioimaging reagent for detection of Fe3+ in living cells.  相似文献   

5.
The synthesis of a novel, and highly selective Fe3+ ion sensor based on anthrone-spirolactam and its quinoline hybrid ligand is reported. The designed ligand displayed selective detection of Fe3+ ions with enhanced fluorescence emission. The complexation of Fe3+ ion led to a red shift of 32 nm from 420 nm to 452 nm, and a several fold increase in intensity with fluorescent green emission. The complexation (detection) of Fe3+ ions with ligand resulted in chelation enhanced fluorescence and intramolecular charge transfer through the inhibition of C=N isomerization. This hybrid sensor shows high sensitivity and selectivity, spontaneous response, and works on a wide pH range a minimum detection limit of 6.83 × 10−8 M. Importantly, the sensor works through the fluorescence turn-on mechanism that overcomes the paramagnetic effect of Fe3+ ions. The binding mechanism between the ligand and the Fe3+ ions was established from the Job's plot method, optical studies, Fourier transfor infrared spectroscopy, NMR titration, fluorescence life-time studies, and density functional theory optimization. The sensor displayed excellent results in the quantification of Fe3+ ions from real water samples. Furthermore, due to its biocompatibility nature, fluorescent spotting of Fe3+ ions in live cells revealed its bioimaging applications.  相似文献   

6.
《印度化学会志》2022,99(11):100754
Naked-eye colored chemo dosimeter based on vanilline based conjugated sensor was synthesized and characterized. The main point of this paper is that the solvent also affects on selectivity of metals. Vanilline based conjugate sensor exhibited high selectivity and sensitivity for detection of Ferric ions (Fe+3) in all (both polar and nonpolar) solvents according to absorbance which can be observed by naked eye. The selectivity was more prominent in nonpolar or less polar solvent due to solubility factor of ions and sensor but not for polar. The detection of limit of the synthesized probes was shown up to 0.84 ppm. The dielectric constant of solvents affected on the complex formation of ligand with transition metal ions. A filter paper strip system was used for rapid monitoring of detection by color variation.  相似文献   

7.
Zhang JR  Huang WT  Xie WY  Wen T  Luo HQ  Li NB 《The Analyst》2012,137(14):3300-3305
Coupling T base with Hg(2+) to form stable T-Hg(2+)-T complexes represents a new direction in detection of Hg(2+). Here a graphene oxide (GO)-based fluorescence Hg(2+) analysis using DNA duplexes of poly(dT) that allows rapid, sensitive, and selective detection is first reported. The Hg(2+)-induced T(15)-(Hg(2+))(n)-T(15) duplexes make T(15) unable to hybridize with its complementary A(15) labelled with 6'-carboxyfluorescein (FAM-A(15)), which has low fluorescence in the presence of GO. On the contrary, when T(15) hybridizes with FAM-A(15) to form double-stranded DNA because of the absence of Hg(2+), the fluorescence largely remains in the presence of GO. A linear range from 10 nM to 2.0 μM (R(2) = 0.9963) and a detection limit of 0.5 nM for Hg(2+) were obtained under optimal experimental conditions. Other metal ions, such as Al(3+), Ag(+), Ca(2+), Ba(2+), Mg(2+), Zn(2+), Mn(2+), Co(2+), Pb(2+), Ni(2+), Cu(2+), Cd(2+), Cr(3+), Fe(2+), and Fe(3+), had no significant effect on Hg(2+) detection. Moreover, the sensing system was used for the determination of Hg(2+) in river water samples with satisfactory results.  相似文献   

8.
《中国化学快报》2023,34(4):107725
Extensive application of nuclear energy has caused widespread environmental uranium contamination. New detection approaches without complicated sample pretreatment and precision instruments are in demand for on-site and in-time determination of uranyl ions in environmental monitoring, especially in an emergency situation. In this work, a simple and effective fluorescent sensor (Z)-N'-hydroxy-4-(1,2,2-triphenylvinyl)benzimidamide (TPE-A) with aggregation-induced emission (AIE) character was established and studied. It could realize to detect UO22+ via quenching the fluorescence of its aggregation-induced emission, with good selectivity and sensitivity. Such strategy shows a wide linear range from 5.0 × 10?8 mol/L to 4.5 × 10?7 mol/L (R2 = 0.9988) with exceptional sensitivity reaching 4.7 × 10?9 mol/L, which is far below the limit for uranium in drinking water (30 μg/L, ca. 1.1 × 10?7 mol/L) stipulated by the WHO. A response time less than four minutes make it rapid for uranyl ion measurement. It was applied for detection of uranyl ion in spiked river water samples with recoveries in the range of 98.7%-104.0%, comparable to those obtained by ICP-MS. With the advantages of portable apparatus, rapid detection process and high sensitivity, TPE-A can serve as a promising fluorescent sensor for the detection of UO22+ in environmental water samples.  相似文献   

9.
《Tetrahedron》2019,75(30):3982-3992
A novel colorimetric and fluorometric dual-channel sensor DA with a favorable optical property and high specificity via a facile synthesis for Cu2+ was developed. DA showed a remarkably rapid response and high selectivity for Cu2+ over other metal ions with low detection limit of 15.1 nM. The sensing mechanism of DA for Cu2+ was based on the chelation-enhanced fluorescence quenching (CHEQ) mechanism, and further confirmed by optical measurements, FTIR, HRMS and DFT calculations. Importantly, DA for sensing Cu2+ possessed excellent sensing performances including colorimetric and fluorometric dual-mode detection, fast response, good reversibility, wide pH response range and strong anti-interference ability. Moreover, the DA could be not only applied to quantitatively detect Cu2+ in environmental water, food and drink samples, but also show highly colorimetric detection of Cu2+ on test strips and silica, indicating its possibility to be utilized as a convenient and low-cost sensor for environment and food monitoring.  相似文献   

10.
11.
Fluorescent conjugated polymer, poly(3-aminobenzoic acid), as a new class of fluorescence sensor for detection of trace amounts of water in organic solvents was developed. This sensor exhibits extraordinarily high sensitivity with a detection limit as low as 0.008 wt% for water in DMF.  相似文献   

12.
Yang MH  Thirupathi P  Lee KH 《Organic letters》2011,13(19):5028-5031
Synthesis of a novel pyrene derivative sensor (Py-Met) based on amino acid and its fluorescent behavior for Hg(II) in water was investigated. Upon Hg(II) binding, the Py-Met-bearing sulfonamide group exhibited a considerable excimer emission at 480 nm along with a decrease of monomer emission at 383 nm. Py-Met allows a selective and sensitive ratiometric detection of Hg(II) without any interference from other metal ions.  相似文献   

13.
In this research,a hydroxyl group functionalized metal-organic framework(MOF),UiO-66-(OH)2,was synthesized as a "on-off-on" fluore scent switching nanoprobe for highly sensitive and selective detection of Fe3+,ascorbic acid(AA) and acid phosphatase(ACP).UiO-66-(OH)2 emits yellow-green light under ultraviolet light,when Fe3+ was added,Fe3+ was chelated with hydroxyl group,the electrons in the excited state S_1 of the MOF transferred to the half-filled 3 d orbits of Fe3+,resulting in fluorescence quenching because of the nonradiative electron/hole recombination annihilation.AA could reduce Fe3+ to Fe2+,which can destroy the electron transfer between UiO-66-(OH)2 and Fe3+ after AA adding,resulted in nonoccurrence of the nonradiative electron transfer,leading to the recovery of UiO-66-(OH)2 fluorescence intensity.The probe can also be used to detect ACP based on the enzymolysis of 2-phospho-L-ascorbic acid(AAP) to produce AA.Benefitting from the hydroxyl group and the characteristics of UiO-66,including the high porosity and large surface area,the developed UiO-66-(OH)2 showed extensive advantages as a fluorescent probe for detection of multi-component,such as high sensitivity and selectivity,colorimetric detection,fast response kinetics and easy to operate,economical and secure.This is the first time to use active group functionalized MOFs as a multicomponent sensor for these three substances detection.  相似文献   

14.
Fluoride anion (F?) affects environmental, biological, and chemical processes significantly. Therefore, its detection has received increasing attention, and sensitive, effective, and convenient probes for F? detection need to be developed urgently. In this work, two perylene tetra-(alkoxycarbonyl) (PTAC) based colorimetric and ratiometric probes, P1 and P2, were developed for the detection of F?. The interactions between F? and these two probes were investigated by absorption, electrochemistry, 1H NMR, and density functional methods. Both the two probes were complexed with F? with a ratio of 1:1. The detection limits of P1 and P2 were 0.22 μM and 0.87 μM, respectively. It was worth noting that the absorption peak of P1 showed a 190 nm red shift when sensing F?, and P1 is the largest red shift value reported in F? probes based on PTAC derivatives. This phenomenon was resulted from the unique configuration and deprotonation of P1 that can promote the intramolecular charge transfer (ICT). This strategy provides an example for the development of other ion probes based on D-A type ICT mechanism.  相似文献   

15.
Solution studies showed a selective interaction between the new synthesized ionophore, 2-[(thiophen-2-yl)methyleneamino]isoindoline-1,3-dione (TMID) and Fe(III) ion. Therefore, TMID was used as an iron selective ion-carrier in a plasticized liquid membrane sensor. The linear response range of the proposed electrode was 1.0 × 10?6–1.0 × 10?2 M. The Nernstian slope of 20.1 ± 0.3 mV/decade, and a detection limit of 5 × 10?7 M was obtained. The sensor could be used in the pH range of 2.3–4.8, and the response time was about 10 s. The lifetime of the electrode was at least 7 weeks. The sensor accuracy was investigated in two ways: (i) with the potentiometric titration of a Fe3+ solution with EDTA and (ii) with Fe(III) monitoring in some cationic mixtures. Finally, the newly fabricated electrode was effectively applied as an indicator electrode for the direct Fe3+ determination in real samples.  相似文献   

16.
Arsenic contamination is a leading environmental problem. As such, levels of this toxic metalloid must be constantly monitored by reliable and low-cost methodologies. Because the currently accepted upper limit for arsenic in water is 10 ppb, very sensitive and selective detection strategies must be developed. Herein we describe the synthesis and characterization of a fluorescent chemical probe, namely, ArsenoFluor1, which is the first example of a chemosensor for As(3+) detection in organic solvents at 298 K. AF1 exhibits a 25-fold fluorescence increase in the presence of As(3+) at λ(em) = 496 nm in THF, which is selective for As(3+) over other biologically relevant ions (such as Na(+), Mg(2+), Fe(2+), and Zn(2+)) and displays a sub-ppb detection limit.  相似文献   

17.
A polymeric membrane ion-selective electrode for determination of heparin is described in this paper.Protamine is incorporated into the organic membrane phase and functions as sensing element for selective recognition of heparin.The proposed membrane electrode exhibits high selectivity for heparin over lipophilic anions such as thiocyanide and salicylate.The potentiometric response to the concentration of heparin is Unear in the range of 0.01-0.4 U/mL and a lower detection limit of 0.005 U/mL can be achieved.  相似文献   

18.
Fe(2+) and Fe(3+) as a redox pair showing different effects on a water-soluble conjugated polymer PPESO(3) is definitely an interesting and useful phenomenon in view of signal transduction and has been utilized to develop sensitive assays of hydrogen peroxide and glucose.  相似文献   

19.
Biochar (BC) has been widely used as a low-cost adsorbent for the removal of contaminants from water and soil. However, the adsorption ability of BC towards heavy metal oxyanions (e.g., Cr(VI)) is relatively low due to the negatively charged surface of BC. In this study, pristine BC was impregnated with Fe3+ to improve its Cr(VI) adsorption capability. Fe3+-impregnated BC (Fe3+-BC) was successfully synthesized by a simple impregnation method and used for the removal of Cr(VI) from aqueous solution. Various factors affecting the adsorption, such as impregnation ratio, pH, adsorbent dosage, contact time, temperature, and the presence of humic acid, were investigated in detail. Results showed that Fe3+-BC had strong adsorption ability to Cr(VI) with a maximum adsorption capacity of 197.80 mg/g, which were not only significantly higher than that of the pristine BC, but also were superior to many previously reported adsorbents. It was favorable for Cr(VI) adsorption under the condition of acidic and high temperature. The adsorption data obeyed Sips and Langmuir isotherms and the kinetic data were well described by the pseudo-first-order kinetic model. The results herein revealed that the Fe3+-impregnated BC had a good potential as a highly efficient material for adsorption of Cr(VI) from aqueous solution.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏