首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Evolutionary factor analysis (EFA) and rank annihilation factor analysis (RAFA) were applied to resolve the two-way equilibrium spectrophotometric data belonging to the complexes of Fe(III), Al(III) and V(V) with morin (3,5,7,20,40-penta hydroxy flavone) as chelating agent in triton X-100 micellar media. Then, partial least square regression combined with genetic algorithm for wavelength selection (GA-PLS) was used for simultaneous determination of the metal ions. The parameters controlling behavior of the system were investigated and optimum conditions were selected. The predictive abilities of partial least squares regression (PLS) and genetic algorithm-partial least squares regression (GA-PLS) were examined in simultaneous determination of ternary mixtures of metal ions over the concentration range of 17.0-170.0ngml(-1), 25.0-180.0ngml(-1) and 40.0-325.0ngml(-1) for Fe(III), Al(III) and V(V), respectively. The relative standard errors for prediction of the ions in synthetic mixtures were lower than 5% and the mean recoveries in the tap water spiked samples were 104.2 and 101.7% for PLS and GA-PLS, respectively.  相似文献   

2.
丛湧  薛英 《物理化学学报》2013,29(8):1639-1647
对89 个苯并异噻唑和苯并噻嗪类丙型肝炎病毒(HCV) NS5B聚合酶非核苷抑制剂进行了定量构效关系(QSAR)研究. 采用遗传算法组合偏最小二乘(GA-PLS)和线性逐步回归分析(LSRA)两种特征选择方法选择最优描述符子集, 然后建立多元线性回归和偏最小二乘线性回归模型. 并首次尝试使用遗传算法耦合支持向量机方法(GA-SVM)对两种特征选择方法所选的描述符子集分别建立非线性支持向量机回归模型. 三种机器学习方法所建模型均得到比较满意的预测效果. 采用LSRA所选的6 个描述符建立的三个QSAR模型对于测试集的相关系数为0.958-0.962, GA-SVM法给出最好的预测精度(0.962). 采用GA-PLS所选的7个描述符建立的三个QSAR模型对于测试集的相关系数为0.918-0.960, 偏最小二乘回归模型的结果最好(0.960). 本工作提供了一种有效的方法来预测丙型肝炎病毒抑制剂的生物活性, 该方法也可以扩展到其他类似的定量构效关系研究领域.  相似文献   

3.
4.
Simultaneous multicomponent analysis is usually carried out by multivariate calibration models such as partial least squares (PLS) that utilize the full spectrum. It has been demonstrated by both experimental and theoretical considerations that better results can be obtained by a proper selection of the spectral range to be included in calculations. A genetic algorithm is one of the most popular methods for selecting variables for PLS calibration of mixtures with almost identical spectra without loss of prediction capacity. In this work, a simple and precise method for rapid and accurate simultaneous determination of sulfide and sulfite ions based on the addition reaction of these ions with new fuchsin at pH 8 and 25°C by PLS regression and using a genetic algorithm (GA) for variable selection is proposed. The concentrations of sulfide and sulfite ions varied between 0.05–2.50 and 0.15–2.00 μg/mL, respectively. A series of synthetic solutions containing different concentrations of sulfide and sulfite were used to check the prediction ability of GA-PLS models. The root mean square error of prediction with PLS on the whole data set was 0.19 μg/mL for sulfide and 0.09 μg/mL for sulfite. After the application of GA, these values were reduced to 0.04 and 0.03 μg/mL, respectively. The text was submitted by the authors in English.  相似文献   

5.
6.
In this study, the simultaneous determination of paracetamol, ibuprofen and caffeine in pharmaceuticals by chemometric approaches using UV spectrophotometry has been reported as a simple alternative to using separate models for each component. Spectra of paracetamol, ibuprofen and caffeine were recorded at several concentrations within their linear ranges and were used to compute the calibration mixture between wavelengths 200 and 400 nm at an interval of 1 nm in methanol:0.1 HCl (3:1). Partial least squares regression (PLS), genetic algorithm coupled with PLS (GA-PLS), and principal component-artificial neural network (PC-ANN) were used for chemometric analysis of data and the parameters of the chemometric procedures were optimized. The analytical performances of these chemometric methods were characterized by relative prediction errors and recoveries (%) and were compared with each other. The GA-PLS shows superiority over other applied multivariate methods due to the wavelength selection in PLS calibration using a genetic algorithm without loss of prediction capacity. Although the components show an important degree of spectral overlap, they have been determined simultaneously and rapidly requiring no separation step. These three methods were successfully applied to pharmaceutical formulation, capsule, with no interference from excipients as indicated by the recovery study results. The proposed methods are simple and rapid and can be easily used in the quality control of drugs as alternative analysis tools.  相似文献   

7.
In this work, different approaches for variable selection are studied in the context of near-infrared (NIR) multivariate calibration of textile. First, a model-based regression method is proposed. It consists in genetic algorithm optimisation combined with partial least squares regression (GA-PLS). The second approach is a relevance measure of spectral variables based on mutual information (MI), which can be performed independently of any given regression model. As MI makes no assumption on the relationship between X and Y, non-linear methods such as feed-forward artificial neural network (ANN) are thus encouraged for modelling in a prediction context (MI-ANN). GA-PLS and MI-ANN models are developed for NIR quantitative prediction of cotton content in cotton-viscose textile samples. The results are compared to full-spectrum (480 variables) PLS model (FS-PLS). The model requires 11 latent variables and yielded a 3.74% RMS prediction error in the range 0-100%. GA-PLS provides more robust model based on 120 variables and slightly enhanced prediction performance (3.44% RMS error). Considering MI variable selection procedure, great improvement can be obtained as 12 variables only are retained. On the basis of these variables, a 12 inputs ANN model is trained and the corresponding prediction error is 3.43% RMS error.  相似文献   

8.
Simultaneous multicomponent analysis is usually carried out using multivariate calibration models, such as the partial least squares (PLS) one, that utilize the full spectrum. It has been shown by both experimental and theoretical considerations that better results can by obtained by proper selection of the spectral range to be included in calculations. A genetic algorithm (GA) is one of the most popular methods for selecting variables for PLS calibration of mixtures with almost identical spectra without loss of predictive capability. In this work, a simple and precise method for rapid and accurate simultaneous determination of sulfide and sulfite ions based on the addition reaction of these ions with new fuchsin at pH 8 and 25°C using PLS regression and GA for variable selection is proposed. The concentrations of sulfide ions varied between 0.05–2.50 and 0.15–2.00 μg/mL, respectively. A series of model solutions containing different concentrations of sulfide and sulfite were used to check the predictive ability of GA-PLS models. The root mean square error of prediction with PLS on the whole data set was 0.19 μg/mL for sulfide and 0.09 μg/mL for sulfite. After the application of GA, these values reduced to 0.04 and 0.03 μg/mL, respectively. The text was submitted by the authors in English.  相似文献   

9.
10.
偏最小二乘法—流动注射pH梯度技术用于同时测定铜和钴   总被引:1,自引:0,他引:1  
以PAR作显色剂,用流动注射pH梯度技术测定多个不同pH下的吸光度,以偏最小二乘法建立校正模型并预测,对Cu~(2+)、Co~(2+)二元素进行了同时测定,其计算结果优于主成分回归及多元线性回归法。  相似文献   

11.
The quantitative predictive abilities of the new and simple bivariate spectrophotometric method are compared with the results obtained by the use of multivariate calibration methods [the classical least squares (CLS), principle component regression (PCR) and partial least squares (PLS)], using the information contained in the absorption spectra of the appropriate solutions. Mixtures of the two drugs Nifuroxazide (NIF) and Drotaverine hydrochloride (DRO) were resolved by application of the bivariate method. The different chemometric approaches were applied also with previous optimization of the calibration matrix, as they are useful in simultaneous inclusion of many spectral wavelengths. The results found by application of the bivariate, CLS, PCR and PLS methods for the simultaneous determinations of mixtures of both components containing 2-12microgml(-1) of NIF and 2-8microgml(-1) of DRO are reported. Both approaches were satisfactorily applied to the simultaneous determination of NIF and DRO in pure form and in pharmaceutical formulation. The results were in accordance with those given by the EVA Pharma reference spectrophotometric method.  相似文献   

12.
13.
The application of chemometrics to analyze the information of the cis/trans structure of alkenes in infrared spectra (IR) is introduced. For data from the OMNIC IR spectral database, two feature selection methods, Fisher ratios and genetic algorithm-partial least squares (GA-PLS), and two classification methods, support vector machine (SVM) and probabilistic neural network (PNN), have been used to obtain optimization classifiers. At last, some spectra from other IR databases are used to evaluate the optimization classifiers. It has been demonstrated that both the SVM and PNN optimization classifiers could give preferable predictive results about the cis and trans structures of alkene.  相似文献   

14.
Differential Pulse Voltammetry has been used for the simultaneous determination of cysteine, tyrosine and trptophan on the unmodified glassy carbon electrode. In the analysis of these analytes in the same samples, the main difficulty is the high degree of overlapping of voltammograms. The relationships between the currents and the concentrations are complex and highly nonlinear. The predictive ability of principal component regression (PCR), partial least squares regression (PLS), genetic algorithm‐partial least squares regression (GA‐PLS) and principal component‐artificial neural networks (PC‐ANNs) were examined for simultaneous determination of three amino acids. For a regression model, everything that could not help in constructing the model may be considered as noise without further specification. PC‐ANN and GA‐PLS use significant data and show superiority over other applied multivariate methods. The proposed method was also applied satisfactorily to determination of analytes in some synthetic samples.  相似文献   

15.
Ghasemi J  Niazi A  Leardi R 《Talanta》2003,59(2):311-317
Genetic algorithm (GA) is a suitable method for selecting wavelengths for PLS (partial least squares) calibration of mixtures with almost identical spectra without loss of prediction capacity using spectrophotometric method. The method is based on the development of the reaction between the analytes and Zincon at pH 9. A series of synthetic solution containing different concentrations of copper and zinc were used to check the prediction ability of the GA-PLS models. The RMSD for copper and zinc with GA and without GA were 0.0407 and 0.0865, 0.2147 and 0.3005, respectively. Calibration matrices were 0.05-1.8 and 0.05-1.5 μg ml−1 for copper and zinc, respectively. This procedure allows the simultaneous determination of cited ions in natural, tap and waste waters good reliability of the determination was proved.  相似文献   

16.
偏最小二乘法及主组分回归法用于药物组分的测定   总被引:9,自引:1,他引:9  
刘家宝  任英 《分析化学》1990,18(10):887-892
本文研究了多元校准方法——偏最小二乘法(PLS)和主组份回归法(PCR)在药物多组份光度分析中的应用,获得了较满意的结果。而且在系列校准样品的实验设计、交叉证实法确定最佳因子数以及空缺组份体系的分析等方面进行了探讨。  相似文献   

17.
In this work we evaluated the use of different variable selection techniques combined with partial least‐squares regression (PLS) – genetic algorithm PLS (GA‐PLS), interval PLS (iPLS), and synergy interval PLS (siPLS) – in the simultaneous determination of Cd(II), Cu(II), Pb(II) and Zn(II) by anodic stripping voltammetry at a bismuth film. Generally, variable selection provided an improvement in prediction results when compared to full‐voltammogram PLS. The use of interval selection based algorithms have shown to be most adequate than the selection of discrete variables by GA. Excellent analytical performances were obtained despite the inherent complexity of the simultaneous determination.  相似文献   

18.
线性特征选择方法可提升定量构效关系(QSAR)模型的预测能力,但易忽略特征(理化属性)与分子活性间的非线性关系。本文提出基于支持向量回归(SVR)的逐步非线性回归(SSNR)特征选择算法并用于降血压药物血管紧张素转化酶(ACE)抑制肽的QSAR研究。首先以具有不同背景的5组分子描述符分别表征肽序列,以SSNR实施特征选择,再通过智能一致性模型(ICM)对各组描述符对应子模型的预测活性进行加权整合,获得最终活性预测值。在ACE抑制二肽与三肽两个数据上的应用结果表明,SSNR获得的特征子集结合ICM策略可有效提升模型预测能力(二肽的平均Q■为0.675±0.002,三肽为0.663±0.013),优于遗传算法-偏最小二乘(0.538±0.049、0.599±0.047)与逐步线性回归(0.583±0.041、0.675±0.010)。最后基于抑制活性已知肽序列预测所有活性未知肽的活性,分析了高活性肽及其氨基酸偏好性,为人工合成潜在高活性ACE抑制肽提供可能的序列组合。  相似文献   

19.
以普通玉米籽粒为试验材料,在应用遗传算法结合偏最小二乘回归法对近红外光谱数据进行特征波长选择的基础上,应用偏最小二乘回归法建立了特征波长测定玉米籽粒中淀粉含量的校正模型.试验结果表明,基于11个特征波长所建立的校正模型,其校正误差(RMSEC)、交叉检验误差(RMSECV)和预测误差(RMSEP)分别为0.30%、0.35%和0.27%,校正数据集和独立的检验数据集的预测值与实际测定值之间的相关系数分别达到0.9279和0.9390,与全光谱数据所建立的预测模型相比,在预测精度上均有所改善,表明应用遗传算法和PLS进行光谱特征选择,能获得更简单和更好的模型,为玉米籽粒中淀粉含量的近红外测定和红外光谱数据的处理提供了新的方法与途径.  相似文献   

20.
Ternary mixtures of thiamin, riboflavin and pyridoxal have been simultaneously determined in synthetic and real samples by applications of spectrophotometric and least-squares support vector machines. The calibration graphs were linear in the ranges of 1.0 - 20.0, 1.0 - 10.0 and 1.0 - 20.0 microg ml(-1) with detection limits of 0.6, 0.5 and 0.7 microg ml(-1) for thiamin, riboflavin and pyridoxal, respectively. The experimental calibration matrix was designed with 21 mixtures of these chemicals. The concentrations were varied between calibration graph concentrations of vitamins. The simultaneous determination of these vitamin mixtures by using spectrophotometric methods is a difficult problem, due to spectral interferences. The partial least squares (PLS) modeling and least-squares support vector machines were used for the multivariate calibration of the spectrophotometric data. An excellent model was built using LS-SVM, with low prediction errors and superior performance in relation to PLS. The root mean square errors of prediction (RMSEP) for thiamin, riboflavin and pyridoxal with PLS and LS-SVM were 0.6926, 0.3755, 0.4322 and 0.0421, 0.0318, 0.0457, respectively. The proposed method was satisfactorily applied to the rapid simultaneous determination of thiamin, riboflavin and pyridoxal in commercial pharmaceutical preparations and human plasma samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号