Initially, a poly (glycidyl methacrylate-co-acrylamide-co-methylenebisacrylamide) monolith was prepared in the 100 μm i.d. capillary, and then was grafted with polyethylenimine (Mw, ∼25,000) for adsorbing Cu2+, followed by chelating trypsin. As a result, efficient digestion for BSA (100 ng/μL) was completed within 50 s via such immobilized enzyme reactor (IMER); yielding 47% sequence coverage by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis. Compared with the conventional method for preparing the metal-ion chelated IMER, the regeneration of such IMER can be achieved facilely by the respective 30 min desorption and re-adsorption of trypsin, and 51% sequence coverage was obtained for 50 s BSA digestion after regeneration. BSA down to femtomole was also efficiently digested by the prepared regenerable IMER. Meanwhile, after the consecutive digestion of myoglobin and BSA, there was not any mutual interference for both during MALDI-TOF MS identification, indicating the low nonspecific adsorption of such regenerable IMER. To test the applicability of regenerable IMER for complex sample profiling, proteins (150 ng) extracted from Escherichia coli were digested within 80 s by the regenerable IMER and further analyzed by nanoreversed phase liquid chromatography–electrospray ionization–mass spectrometry successfully, showing its practicability for the high throughput analysis of complex samples.  相似文献   

2.
肖鹏  李大雷  满燕  耿利娜  吕雪飞  邓玉林 《色谱》2012,30(11):1127-1132
将核酸适配体作为胰蛋白酶固定化介质,制备了一种新型的微流控芯片酶反应器,并与高效液相色谱-串联质谱联用,搭建了在线分析平台;分别使用标准蛋白及混合蛋白样品对芯片的酶解效率及联用平台的分析能力进行了初步评价。结果表明,5 ng肌红蛋白经该平台分析后肽段覆盖率可达到37%;对500 ng混合蛋白进行3次平行分析,肽段覆盖率及相对标准偏差分别为44.3%、6.5%(牛血清白蛋白), 65.0%、2.7%(肌红蛋白)和62.0%、5.6%(细胞色素c);初步实验表明,该在线分析平台具有检测灵敏度高、重现性好、酶解效率高的特点,有望在蛋白质组学分析中发挥重要作用。  相似文献   

3.
The preparation and characterization of a miniaturized trypsin reactor using on-line coupling with an ESI-TOF mass spectrometer are described. L-1-Tosylamido-2-phenylethyl chloromethyl ketone-trypsin was covalently immobilized on poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith prepared in a 75 microm ID fused silica capillary resulting in a bioreactor with high local concentration of the proteolytic enzyme. Covalent immobilization of trypsin on this support was performed using the epoxide functional groups in either a one- or a multistep reaction. For on-line protein digestion-MS analysis the bioreactor was coupled with the mass spectrometer using a liquid junction microelectrospray interface. The performance of the reactor was tested using an on-line flow through the system with flow rates of 50-300 nL/min. The resulting protein consumption was in the atto- to low femtomole range. Proteolytic activity was characterized in a wide range of conditions with respect to the flow rate, pH, and temperature. Complete protein digestion was achieved in less than 30 s at 25 degrees C with the sequence coverage of 80% (cytochrome c), which is comparable to 3 h digestion in solution at 37 degrees C. Besides the good performance at laboratory temperature, the immobilized trypsin in the bioreactor also performed well at lower pH compared to the standard in-solution protocols.  相似文献   

4.
Fast and effective protein digestion is a vital process for mass spectrometry (MS) based protein analysis. This study introduces a porous polymer membrane enzyme reactor (PPMER) coupled to nanoflow liquid chromatography-tandem MS (nLC-ESI-MS/MS) for on-line digestion and analysis of proteins. Poly (styrene-co-maleic anhydride) (PS-co-MAn) was fabricated by the breath figure method to make a porous polymer membrane in which the MAn group was covalently bound to enzyme. Based on this strategy, microscale PPMER (μPPMER) was constructed for on-line connection with the nLC-ESI-MS/MS system. Its capability for enzymatic digestion with bovine serum albumin (BSA) was evaluated with varied digestion periods. The on-line proteolysis of BSA and subsequent analysis with μPPMER-nLC-ESI-MS/MS revealed that peptide sequence coverage increased from 10.3% (digestion time 10 min) to 89.1% (digestion time 30 min). μPPMER can efficiently digest proteins due to the microscopic confinement effect, showing its potential application in fast protein identification and protease immobilization. Applications of on-line digestion using μPPMER with human plasma and urinary proteome samples showed that the developed on-line method yielded equivalent or better performance in protein coverage and identified more membrane proteins than the in-solution method. This may be due to easy accommodation of hydrophobic membrane proteins within membrane pores.  相似文献   

5.
A microfluidic device is described in which an electrospray interface to a mass spectrometer is integrated with a capillary electrophoresis channel, an injector and a protein digestion bed on a monolithic substrate. A large channel, 800 microm wide, 150 microm deep and 15 mm long, was created to act as a reactor bed for trypsin immobilized on 40-60 microm diameter beads. Separation was performed in channels etched 10 microm deep, 30 microm wide and about 45 mm long, feeding into a capillary, attached to the chip with a low dead volume coupling, that was 30 mm in length, with a 50 microm i.d. and 180 microm o.d. Sample was pumped through the reactor bed at flow rates between 0.5 and 60 microL/min. The application of this device for rapid digestion, separation and identification of proteins is demonstrated for melittin, cytochrome c and bovine serum albumin (BSA). The rate and efficiency of digestion was related to the flow rate of the substrate solution through the reactor bed. A flow rate of 1 or 0.5 microL/min was found adequate for complete consumption of cytochrome c or BSA, corresponding to a digestion time of 3-6 min at room temperature. Coverage of the amino acid sequence ranged from 92% for cytochrome c to 71% for BSA, with some missed cleavages observed. Melittin was consumed within 5 s. In contrast, a similar extent of digestion of melittin in a cuvet took 10-15 min. The kinetic limitations associated with the rapid digestion of low picomole levels of substrate were minimized using an integrated digestion bed with hydrodynamic flow to provide an increased ratio of trypsin to sample. This chip design thus provides a convenient platform for automated sample processing in proteomics applications.  相似文献   

6.
The goal of this paper was to develop an in-line immobilized enzyme reactor (IMER) integrated into a capillary electrophoresis platform. In our research, we created the IMER by adsorbing trypsin onto the inner surface of a capillary in a short section. Enzyme immobilization was possible due to the electrostatic attraction between the oppositely charged fused silica capillary surface and trypsin. The reactor was formed by simply injecting and removing trypsin solution from the capillary inlet (~1–2 cms). We investigated the factors affecting the efficiency of the reactor. The main advantages of the proposed method are the fast, cheap, and easy formation of an IMER with in-line protein digestion capability. Human tear samples were used to test the efficiency of the digestion in the microreactor.  相似文献   

7.
A platform for rapid on-line protein digestion of protein mixtures for direct infusion to a mass spectrometer is presented. A mixture of protein A, staphylococcal enterotoxin B and cytochrome c was used as a model mixture injected on a gel filtration column and a trypsin reactor which were connected in series to a micro liquid chromatography (microLC) system. The peptides in the column eluate were analyzed with ESI tandem mass spectrometry, utilizing information dependent acquisition (IDA). In one step, the proteins in the mixture (microM concentrations) were concomitantly desalted, separated, digested and identified with an overall analysis time of less than 40 min. Protein sequence coverage of 78-95% for the involved substances was achieved.  相似文献   

8.
Zhang P  Gao M  Zhu S  Lei J  Zhang X 《Journal of chromatography. A》2011,1218(47):8567-8571
In this report, laser radiation (808nm) for the first time was employed to enhance the efficiency of proteolysis through immobilized enzyme reactor (IMER). IMER based monolithic support was prepared in the fused-silica capillary via a simple two-step procedure including acryloylation on trypsin surface and in situ aqueous polymerization/immobilization. The feasibility and high efficiency of the laser-assisted IMER were demonstrated by the digestion of bovine serum albumin (BSA), cytochrome c (Cyt-c) and β-casein. The digestion process was achieved in 60s. The peptides were identified by MALDI-TOF-MS, yielding the sequence coverage of 33% for BSA, 73% for Cyt-c and 22% for β-casein. The comparisons between the in-solution digestion and on IMER reaction with/without laser assistance were made. To further confirm its efficiency in proteome analysis, the laser-assisted IMER was also applied to the analysis of one fraction of human serum sample through two-dimensional (2-D) separation of strong anion exchange/reversed-phase liquid chromatography (SAX/RPLC). After a database search, 49 unique peptides corresponding to 5 proteins were identified. The results showed that the laser-assisted IMER provides a promising platform for the high-throughput protein identification.  相似文献   

9.
A study was initiated to construct a micro-reactor for protein digestion based on trypsin-coated fused-silica capillaries. Initially, surface plasmon resonance was used both for optimization of the surface chemistry applied in the preparation and for monitoring the amount of enzyme that was immobilized. The highest amount of trypsin was immobilized on dextran-coated SPR surfaces which allowed the covalent coupling of 11 ng mm−2 trypsin. Fused-silica capillaries were modified in a similar manner and the resulting open-tubular trypsin-reactors having a pH optimum of pH 8.5, display a high activity when operated at 37 °C and are stable for at least two weeks when used continuously. Trypsin auto-digestion fragments, sample carry-over, and loss of signal due to adsorption of the protein were not observed. On-line digestion without prior protein denaturation, followed by micro-LC separation and photodiode array detection, was tested with horse-heart cytochrome C and horse skeletal-muscle myoglobin. The complete digestion of 20 pmol μL−1 horse cytochrome C was observed when the average residence time of the protein sample in a 140 cm ×50 μm capillary immobilized enzyme reactor (IMER) was 165 s. Mass spectrometric identification of the injected protein on the basis of the tryptic peptides proved possible. Protein digestion was favorable with respect to reaction time and fragments formed when compared with other on-line and off-line procedures. These results and the easy preparation of this micro-reactor provide possibilities for miniaturized enzyme-reactors for on-line peptide mapping and inhibitor screening.  相似文献   

10.
《Analytical letters》2012,45(5):868-878
Efficient protein digestion is a key step for successful mass spectrometry identification. However, traditional in-solution digestion suffers some drawbacks, such as autolysis of protease, long analysis times and lack of control. Recently, specific single-stranded nucleic acids, aptamers, screened from random sequence pools, have been performed high affinity for targets. In this paper, we have developed a novel enzyme reactor, which immobilized chymotrypsin based on aptamer-grafted silica beads. Mixed proteins, which consist of bovine serum albumin, myoglobin, and cytochrome c, were used as samples, to evaluate the digestion performance of the enzymatic reactor. With the use of this novel tool, proteins were digested in 40 min to an extent similar to that achieved with soluble enzyme at 37°C after 16 h. Moreover, enzymatic reactor regeneration was carried out through chymotrypsin elution and re-immobilization. The advanced characteristics of the aptamer-based chymotrypsin reactor demonstrated that aptamers could serve as novel materials for rapid and efficient enzyme immobilization and application in protein studies.  相似文献   

11.
Yao C  Qi L  Hu W  Wang F  Yang G 《Analytica chimica acta》2011,692(1-2):131-137
A new kind of immobilized trypsin reactor based on sub-micron skeletal polymer monolith has been developed. Covalent immobilization of trypsin on this support was performed using the epoxide functional groups in either a one- or a multi-step reaction. The proteolytic activity of the immobilized trypsin was measured by monitoring the formation of N-α-benzoyl-L-arginine (BA) which is the digestion product of a substrate N-α-benzoyl-L-arginine ethyl ester (BAEE). Results showed that the digestion speed was about 300 times faster than that performed in free solution. The performance of such an enzyme reactor was further demonstrated by digesting protein myoglobin. It has been found that the protein digestion could be achieved in 88 s at 30°C, which is comparable to 24 h digestion in solution at 37°C. Furthermore, the immobilized trypsin exhibits increased stability even after continuous use compared to that in free solution. The present monolithic enzyme-reactor provides a promising platform for the proteomic research.  相似文献   

12.
Liming Wei  Pengyuan Yang 《Talanta》2010,80(3):1298-1151
Immobilization of enzyme on detonation nanodiamond (dND, 3-10 nm) and its application for efficient proteolysis have been demonstrated. By evaluation of the Michaelis constant (Km) and maximum velocity (Vmax) of immobilized enzyme, its activity was not impaired significantly by immobilization. And enzyme immobilized on dNDs exhibited much better thermal and chemical stabilities than its free counterpart and maintained high activity even after 10 times reuse. The efficient proteolysis by trypsin immobilized on dNDs (dND-trypsin) is demonstrated with the digestion of myoglobin (or other model protein) in a short time (5 min). Large numbers of identified peptides obtained by dNDs-trypsin enable a higher degree of sequence coverage and more positive identification of proteins than those obtained by in-solution digestion and the commercial immobilized trypsin beads, respectively. Moreover, immobilization of peptide-N-glycosidase F (PNGase F) on dNDs was realized and resulted in faster sequential glycosidase digestion of glycopeptides in less than 10 min.  相似文献   

13.
利用毛细管作为酶固定化的载体,将酶直接键合到毛细管内壁,制成毛细管纳升反应器,结合质谱分析水解产物,获得了蛋白质的肽谱.实验发现,以毛细管为反应器后,蛋白质肽谱分析所需量大大减少,只需10-13mol,甚至几个10-15mol的量就可满足分析要求.  相似文献   

14.
Off-line digestion of proteins using immobilized trypsin beads is studied with respect to the format of the digestion reactor, the digestion conditions, the comparison with in-solution digestion and its use in complex biological samples. The use of the filter vial as the most appropriate digestion reactor enables simple, efficient and easy-to-handle off-line digestion of the proteins on trypsin beads. It was shown that complex proteins like bovine serum albumin (BSA) need much longer time (89 min) and elevated temperature (37 degrees C) to be digested to an acceptable level compared to smaller proteins like cytochrome c (5 min, room temperature). Comparing the BSA digestion using immobilized trypsin beads with conventional in-solution digestion (overnight at 37 degrees C), it was shown that comparable results were obtained with respect to sequence coverage (>90%) and amount of missed cleavages (in both cases around 20 peptides with 1 or 2 missed cleavages were detected). However, the digestion using immobilized trypsin beads was considerable less time consuming. Good reproducibility and signal intensities were obtained for the digestion products of BSA in a complex urine sample. In addition to this, peptide products of proteins typically present in urine were identified.  相似文献   

15.
合成了甲基丙烯酸缩水甘油酯-纤维素复合膜,并以此膜为基质共价键合固定化胰蛋白酶,以N-苯甲酰-L-精氨酰乙酯(BAEE)为底物,应用高效液相色谱系统测定了酶固定化膜柱的催化反应特性。研究结果表明:温度、pH值、离子强度、有机溶剂及蛋白变性剂等都对固定化酶的活力有一定的影响。在最适条件下,固定化胰蛋白酶的活力为17800U/g干膜,蛋白载量为3.6mg/g(≈0.15μmol/g)干膜,活性回收率达到52%.固定化酶表现出较高的使用和储藏稳定性,在40℃下,水解BAEE底物24h活力无显着变化。固定化酶膜柱在4℃冷藏保存100d仍保存90%以上的水解活力。固定化酶反应器被应用于蛋白质酶解的肽谱实验。  相似文献   

16.
Wang C  Jemere AB  Harrison DJ 《Electrophoresis》2010,31(22):3703-3710
We describe a microfluidic device in which integrated tryptic digestion, SPE, CE separation and electrospray ionization for MS are performed. The chip comprised of 10 × 30 μm channels for CE, and two serially connected 150?μm deep, 800?μm wide channels packed with 40 to 60 μm diameter beads, loaded with either immobilized trypsin, reversed-phase packing or both. On-chip digestion of cytochrome c using the trypsin bed showed complete consumption of the protein in 3 min, in contrast to the 2 h required for conventional solution phase tryptic digestion. SPE of 0.25 μg/mL solutions of the peptides leu-enkephalin, angiotensin II and LHRH gave concentration enhancements in the range of 4.4-12, for a ten times nominal volume ratio. A 100 nM cytochrome c sample concentrated 13.3 times on-chip gave a sequence coverage of 85.6%, with recovery values ranging from 41.2 to 106%. The same sample run without SPE showed only five fragment peaks and a sequence coverage of 41.3%. When both on-chip digestion and SPE (13.3 volume ratio concentration enhancement) were performed on 200 nM cytochrome c samples, a sequence coverage of 76.0% and recovery values of 21-105% were observed. Performing on-chip digestion alone on the same sample gave only one significant fragment peak. The above digestion/peptide concentration step was compared to on-chip protein concentration by SPE followed by on-chip digestion with solution phase trypsin. Both procedures gave similar recovery results; however, much larger trypsin autodigestion interference in the latter approach was apparent.  相似文献   

17.
以石英毛细管作为酶固定化的载体, 在毛细管内壁上逐步合成树枝形大分子聚酰胺-胺(PAMAM), 再通过交联剂戊二醛将胰蛋白酶直接键合到该大分子的末端氨基上, 并对酶固定化条件进行了优化, 制备了多层酶反应器. 利用该酶反应器对马心细胞色素C等蛋白质进行了酶切, 并对酶切的条件进行了优化. 实验结果表明, 该固定化酶反应器具有较高的酶切效率、良好的重现性和稳定性, 可用于蛋白质组学的研究.  相似文献   

18.
Wang T  Ma J  Wu S  Yuan H  Zhang L  Liang Z  Zhang Y 《Electrophoresis》2011,32(20):2848-2856
An integrated platform with the combination of protein and peptide separation was established via online protein digestion, by which proteins were first separated by CIEF, online digested by a trypsin immobilized enzyme microreactor, trapped and desalted by two parallel trap columns, separated by nanoreversed-phase and finally identified by MS. In such a platform, two hollow fiber membrane interfaces were used. One was applied to supply catholyte and electric contact, and another to supply adjustment buffer to improve the compatibility of protein separation and tryptic digestion. A poly(octadecyl acrylate-co-ethylene dimethacrylate) monolithic column served as the trap column to capture sample and to remove the ampholytes from CIEF. A hybrid silica monolith-based immobilized trypsin microreactor was used for online protein digestion. To evaluate the performance of such a platform, a 4-protein mixture with a loading amount of only 0.29?μg, was analyzed, and sequence coverages for BSA, myoglobin, β-lactoglobulin and ribonuclease A were 8, 26, 10 and 54%, respectively. Furthermore, such an integrated platform was successfully applied for the analysis of proteins extracted from Escherichia coli, and 101 proteins were positively identified. We anticipate that the integrated platform developed herein will provide a promising tool for low-abundance protein identification with the combination of top-down and bottom-up approaches.  相似文献   

19.
Sim TS  Kim EM  Joo HS  Kim BG  Kim YK 《Lab on a chip》2006,6(8):1056-1061
We have carried out a simultaneous thermal denaturation and trypsin digestion of proteins using a temperature-controllable microreactor. This is a simple and rapid sample preparation technique for use before matrix-assisted laser desorption ionization time-of-flight mass spectrometry. In contrast to a conventional sample preparation method, which involves several chemical treatments, our sample preparation was performed using only trypsin digestion with the thermal denaturation of the target protein. Optimization of the reactor operational parameters for trypsin digestion using a temperature-controllable microreactor was carried out. The entire trypsin digestion procedure took about 11 min, and consisted of 1 min for the thermal denaturation of the sample protein (3 microl, 0.2 microM) at 85 degrees C, and 10 min for digestion of the protein at 37 degrees C. The resulting sequence coverage ranged from 24% to 57%, which was sufficient for practical protein identification.  相似文献   

20.
A nanoreactor based on mesoporous silicates is described for efficient tryptic digestion of proteins within the mesochannels. Cyano-functionalized mesoporous silicate (CNS), with an average pore diameter of 18 nm, is a good support for trypsin, with rapid in situ digestion of the model proteins, cytochrome c and myoglobin. The generated peptides were analyzed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Proteolysis by trypsin-CNS is much more efficient than in-solution digestion, which can be attributed to nanoscopic confinement and concentration enrichment of the substrate within the mesopores. Proteins at concentrations of 2 ng muL(-1) were successfully identified after digestion for 20 min. A biological complex sample extracted from the cytoplasm of human liver tissue was digested by using the CNS-based reactor. Coupled with reverse-phase HPLC and MALDI-TOF MS/MS, 165 proteins were identified after standard protein data searching. This nanoreactor combines the advantages of short digestion time with retention of enzymatic activity, providing a promising way to advance the development of proteomics.  相似文献   