首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel method for the separation and preconcentration of Se(IV)/ Se(VI) with algae and determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed. The Se(VI) is extracted with algae from the solution containing Se(IV)/Se(VI) at pH 5.0, and the remaining Se(IV) is then preconcentrated pH 1.0. The detection limits (3σ, n = 11) of 0.16 μg L–1 for Se(IV) and 0.14 μg L–1 for Se(VI) are obtained using 40 mL of solution. At the 2.0 μg L–1 level the relative standard deviation is 2.6% for Se(IV) and 2.3% for Se(VI). The method has been applied to the determination of Se(IV)/Se(VI) in sediment and water samples. Analytical recoveries of Se(IV) and Se(VI) added to samples are ¶97 ± 5% and 102 ± 6% (95% confidence), respectively.  相似文献   

2.
A new method for the simultaneous separation and determination of four arsenic species [As(III), As(V), monomethylarsonic acid and dimethylarsinic acid], three selenium species [Se(IV), Se(VI) and selenomethionine] as well as Sb(III) and Sb(V) is presented. The speciation was achieved by on-line coupling of anion exchange high-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). Chromatographic parameters such as the composition and pH of the mobile phase were optimised. Limits of detection are below 4.5 μg L–1 (as element) for Sb(III) and the selenium species and below 0.5 μg L–1 for the other species. Precisions of retention times were better than 2% RSD and of peak areas better than 8% RSD for all the species investigated. Received: 13 January 1999 / Accepted: 4 March 1999  相似文献   

3.
A sensitive and non chromatographic analytical procedure for the separation of inorganic selenium species in natural water has been performed. A combination of APDC coprecipitation and determination by an absolute thin layer Energy dispersive X-ray fluorescence spectrometry method was used. The influence of various analytical parameters such as element concentration, oxidation states and pH on the recoveries of Se (IV) was examined. The presence of organic matter and bicarbonate anions, typical components in Cuban groundwater samples, was also tested. Negligible matrix effects were observed. At pH 4 a 100% recovery was found for Se (IV). The coprecipitation recovery of the oxidized selenium species (Se (VI)) was null for the selected concentration range (5–100 μg L−1). When the Se (VI) was reduced by heating the solution with 4 mol L−1 HCl, quantitative recovery was also obtained. The determination of total selenium was conducted by the application of the oxidation–reduction process and the analytical procedure for Se (IV). Se (VI) content was calculated as the difference between total selenium and Se (IV). The detection limit was 0.13 μg L−1. The relative standard deviation was lower than 3.5% for 5 μg L−1 of Se (IV). The trueness of the method was verified by using standardized hydride generation-atomic absorption spectrometry technique. The results obtained using the EDXRF technique were in good agreement with the ones determined by HG-AAS. The proposed method was applied to the determination of Se (IV) in surface water and groundwater samples.  相似文献   

4.
Determination of Se(IV) and Se(VI) in high saline media was investigated by cathodic stripping voltammetry (CSV). The voltammetric method was applied to assay selenium in seawater, hydrothermal and hemodialysis fluids. The influence of ionic strength on selenium determination is discussed. The CSV method was based on the co-electrodeposition of Se(IV) with Cu(II) ions and Se(VI) determined by difference after sample UV-irradiation for photolytic selenium reduction. UV-irradiation was also used as sample pre-treatment for organic matter decomposition. Detection limit of 0.030 μg L−1 (240 s deposition time) and relative standard deviation (RSD) of 6.19% (n = 5) for 5.0 μg L−1 of Se(IV) were calculated. Linear calibration range for selenium was observed from 1.0 to 100.0 μg L−1. Concerning the pre-treatment step, best results were obtained by using 60 min UV-irradiation interval in H2O2/HCl medium. Se(VI) was reduced to the Se(IV) electroactive species with recoveries between 91.7% and 112.9%. Interferents were also investigated.  相似文献   

5.
An on-line system is proposed consisting of an anion-exchange chromatographic column, microwave-induced thermooxidation of trimethylselenium in the presence of persulphate, and microwave-induced thermoreduction of Se(VI) to Se(IV) in HCl medium, followed by hydride generation and atomic absorption for the determination of trimethylselenium (TMeSe), Se(IV) and Se(VI). Trimethylselenium is eluted in the dead volume of an anion-exchange column (Hamilton PRP-X-100), before elution of Se(IV) and Se(VI). Optimum chromatographic conditions have been obtained using 100 mmol L–1 phosphate buffer (pH=6.8) H2PO 4 /HPO 4 2– as the mobile phase. Recoveries were around 100%, absolute detection limits were 1.1, 1.4 and 2.2 ng for TMeSe, Se(IV) and Se(VI), respectively. Precision was lower than 10% in all cases. The method has been applied to tap water.  相似文献   

6.
Summary An ion-chromatographic procedure is described for the determination of selenium (VI) at μg L−1 level in the presence of anions and heavy metal ions. Maximum permissible concentrations and effects from each interfering substance were investigated for the Se concentration range 12.5–1,000 μg L−1. The method, optimized for the detection of SeO 4 2− , gives results suitable for speciation analysis. Total selenium can be determined after complete conversion to selenate ion by oxidation with KMnO4. The detection limit of selenium is 4.8 μg L−1 (0.96 ng for 200 μL sample). Paper presented at the 41st Pittsburgh Conference, New York, March 5–9, 1990.  相似文献   

7.
A continuous flow atomic absorption spectrometric system was used to develop an efficient on-line preconcentration-elution procedure for the determination of iodide traces. Chromium (VI) is introduced into the flow system and is reduced to chromium (III) in acid medium proportionally to the iodide present in the sample. The Cr(III) reduced by iodide is retained on a minicolumn packed with a poly(aminophosphonic acid) chelating resin, while unreduced Cr(VI) is not retained. Reduced Cr(III) is preconcentrated by passing the sample containing iodide through the system during 3 min, and is then eluted with 0.5 mol L–1 hydrochloric acid and determined by flame atomic absorption spectrometry (FAAS). The detection limit (3σ) obtained is 2.5 μg L–1. Other ions typically present in waters do not interfere. The proposed method allows the determination of iodide in the range 6–220 μg L–1 with a relative standard deviation of 2.7% at a rate of 17 samples h–1. The method has been applied to the determination of iodide in tap and sea waters. Received: 16 September 1999 / Revised: 15 November 1999 / Accepted: 19 November 1999  相似文献   

8.
Neutron activation analysis using shortlived77mSe (T=17.5 s) preceded by chemical pre-collection of Se on activated carbon (AC) has been applied to the fractional determination of Se(IV) and Se(VI) in natural water samples such as river water and sea water. Two chemical procedures were adopted: adsorption of Se(IV)/Bismuthiol-II complex on AC and adsorption of Se(VI)/Bismuthiol-II on AC after reduction of Se(VI) to Se(IV). It was shown that Se(IV) and Se(VI) can be determined at a <g l–1 (ppb) level in natural waters by the present method.  相似文献   

9.
Summary A rapid, selective and sensitive method has been developed for the simultaneous determination of selenate [Se(VI)] and selenite [Se(IV)] at trace levels by single-column ion chromatography. p-Hydroxybenzoic acid (4 mM) at pH 8.0 was used as the eluent. A low capacity resin-based anion-exchange column was employed for the separation with conductometric detection for quantification. The method requires minimal sample pretreatment. Resolution (Rs) between Se(VI)/Se(IV) was 6.76. Chloride, nitrate and sulfate did not interfere with selenium separation. The detection limits for Se(VI) and Se(IV) were 0.06 μg/ml and 0.110 μg/ml, respectively. The relative standard deviation using a 500-μl loop was 0.90 to 1.86% for Se(VI) and Se(IV), respectively. The method was applied to analyze seleniferous soil samples.  相似文献   

10.
Numerous commonly used analytical methods allow only determination of a total amount of selenium in a given sample. Electroanalytical methods as well as those based on hydride generation or on formation of piazselenol allow only determination of Se(IV). To determine Se(VI) by these procedures, present alone or in mixtures with Se(IV), it is first necessary to convert Se(VI) to Se(IV). Such conversion is effective in the presence of excess of halides in acidic media or by photoreduction. In the often used conversion of Se(VI) in the presence of chlorides or less frequently of that of bromides, it has been assumed that the halide ion acts as a reducing agent. Kinetic studies of conversion of Se(VI) in acidic solutions containing an excess of bromide ions indicated that the rate determining first step of the reaction with Se(VI) is a nucleophilic substitution of the OH2+ group in the protonated form of H2SeO4 by bromide ions. For the overall reaction with rate −d[Se(VI)]/dt = k1[H+][Br]1.15[Se(IV)] the rate constant 1 × 10−3 L2 mol−2 s−1 was found. The following formation of Se(IV) from the bromo derivative is a fast reaction probably resulting in elimination of HBrO.  相似文献   

11.
 Parameters for the reduction of Se(VI) to Se(IV) in HCl medium by heating in a microwave oven have been optimized. The reduction resulted to be quantitative applying 100% power, corresponding to 600 W heating for 2 min in 6 mol/L or for 3 min in 4 mol/L HCl. The behavior of selenomethionine and selenocystine under the optimized reduction conditions was studied in order to evaluate a possible interference of these selenium species in the determination of Se(VI). The final determination of Se(IV), and Se(VI) were done by hydride generation-atomic absorption spectrometry. The analytical merits of the method are reported. The method was applied to the selective determination of Se(IV), and Se(VI) in spiked river and lake water. Received: 6 December 1996/Revised: 1 April 1997/Accepted: 3 April 1997  相似文献   

12.
A new, sensitive and very simple spectrofluorimetric biparameter sensor is described for the determination of salicylamide and/or salicylic acid in pharmaceutical preparations. The method integrates the transitory retention and fluorescence detection of both compounds on Sephadex QAE A-25 resin packed into a conventional flow-through cell. A monochannel manifold with two alternative carriers is used. At pH 2.0 (first carrier) salicylic acid is selectively retained on the solid support and after developing the analytical signal it is desorbed. At pH 11.0 (second carrier) both salicylic acid and salicylamide are simultaneously and transitorily retained on the solid, the analytical signal now corresponding to both analytes. The monochromators were tuned at 260 (excitation) and 415 (emission) nm, respectively. The calibration graph for salicylamide is linear over the range 0.01 to 0.32 μg mL–1 and for salicylic acid from 0.04 to 1.0 μg mL–1 in the presence of each other. The relative standard deviation and the sampling frequency for the determination of salicylamide (0.20 μg mL–1) and salicylic acid (0.50 μg mL–1) were 1.1% and 35 h–1, and 0.9% and 45 h–1, respectively. Good results on application to individual determination or mixture resolution in pharmaceutical samples testify to the usefulness of the proposed sensor. Received: 20 April 1999 / Revised: 7 June 1999 / Accepted: 12 June 1999  相似文献   

13.
A sensitive and simple analytical method has been developed for determination of Sb(III), Sb(V), Se(IV), Se(VI), Te(IV), Te(VI), and Bi(III) in garlic samples by using hydride-generation–atomic-fluorescence spectrometry (HG–AFS). The method is based on a single extraction of the inorganic species by sonication at room temperature with 1 mol L−1 H2SO4 and washing of the solid phase with 0.1% (w/v) EDTA, followed by measurement of the corresponding hydrides generated under two different experimental conditions directly and after a pre-reduction step. The limit of detection of the method was 0.7 ng g−1 for Sb(III), 1.0 ng g−1 for Sb(V), 1.3 ng g−1 for Se(IV), 1.0 ng g−1 for Se(VI), 1.1 ng g−1 for Te(IV), 0.5 ng g−1 for Te(VI), and 0.9 ng g−1 for Bi(III), in all cases expressed in terms of sample dry weight.  相似文献   

14.
A smart fully automated system is proposed for determination of thorium and uranium in a wide concentration range, reaching environmental levels. The hyphenation of lab-on-valve (LOV) and multisyringe flow injection analysis (MSFIA), coupled to a long path length liquid waveguide capillary cell, allows the spectrophotometric determination of thorium and uranium in different types of environmental sample matrices achieving high selectivity and sensitivity levels. Online separation and preconcentration of thorium and uranium is carried out by means of Uranium and TEtraValents Actinides resin. The potential of the LOV–MSFIA makes possible the full automation of the system by the in-line regeneration of the column and its combination with a smart methodology is a step forward in automation. After elution, thorium(IV) and uranium(VI) are spectrophotometrically detected after reaction with arsenazo-III. We propose a rapid, inexpensive, and fully automated method to determine thorium(IV) and uranium(VI) in a wide concentration range (0–1,200 and 0–2,000 μg L-1 Th and U, respectively). Limits of detection reached are 5.9 ηg L-1 of uranium and 60 ηg L-1 of thorium. Different water sample matrices (seawater, well water, freshwater, tap water, and mineral water), and a channel sediment reference material which contained thorium and uranium were satisfactorily analyzed with the proposed method.  相似文献   

15.
This paper reports silica gel loaded with p-tert-butylcalix[8]arene as a new solid phase extractor for determination of trace level of uranium. Effective extraction conditions were optimized in column methods prior to determination by spectrophotometry using arsenazo(III). The results showed that U(VI) ions can be sorbed at pH 6 in a mini-column and quantitative recovery of U(VI) (>95–98%) was achieved by stripping 0.4 mol L−1 HCl. The sorption capacity of the functionalized sorbent is 0.072 mmol uranium(VI) g−1 modified silica gel. The relative standard deviation and detection limit were 1.2% (n = 10) for 1 μg uranium(VI) mL−1 solution and 0.038 μg L−1, respectively. The method was employed to the preconcentration of U(VI) ions from spiked ground water samples.  相似文献   

16.
Olive cake as low-cost abundantly available sorbent has been characterized by N2 at 77 K adsorption, porosity analysis, elemental analysis and IR spectra and has been used for preconcentrating of uranium(VI) and thorium(IV) ions prior to their determination spectrophotometrically. The optimum pH values for quantitative sorption of U(VI) and Th(IV) are 4–7 and 3–7, respectively. The enrichment factor for the preconcentration of U(VI) and Th(IV) were found to be 125 and 75 in the given order. The sorption capacity of olive cake is in the range of 2,260–15,000 μg g−1 for Th(IV) and in the range of 1,090–17,000 μg g−1 for U(VI) at pH 3–7. The sorbent exhibits good reusability and the uptake and stripping of the studied ions were fairly rapid. The elution of U(VI) and Th(IV) was performed with 0.3–1 M HCl/1–2 M HNO3 and 0.3–0.8 M HCl/1 M HNO3, respectively. The precision of the method was 1.8 RSD% for U(VI) and 2.5 RSD% for Th(IV) in a concentration of 1.00 μg mL−1 for 10 replicate analysis. The influence of some electrolytes and cations as interferents was discussed. Separation of U(VI) and Th(IV) from other metal ions in synthetic solution was achieved.  相似文献   

17.
A new, sensitive and very simple spectrofluorimetric biparameter sensor is described for the determination of salicylamide and/or salicylic acid in pharmaceutical preparations. The method integrates the transitory retention and fluorescence detection of both compounds on Sephadex QAE A-25 resin packed into a conventional flow-through cell. A monochannel manifold with two alternative carriers is used. At pH 2.0 (first carrier) salicylic acid is selectively retained on the solid support and after developing the analytical signal it is desorbed. At pH 11.0 (second carrier) both salicylic acid and salicylamide are simultaneously and transitorily retained on the solid, the analytical signal now corresponding to both analytes. The monochromators were tuned at 260 (excitation) and 415 (emission) nm, respectively. The calibration graph for salicylamide is linear over the range 0.01 to 0.32 μg mL–1 and for salicylic acid from 0.04 to 1.0 μg mL–1 in the presence of each other. The relative standard deviation and the sampling frequency for the determination of salicylamide (0.20 μg mL–1) and salicylic acid (0.50 μg mL–1) were 1.1% and 35 h–1, and 0.9% and 45 h–1, respectively. Good results on application to individual determination or mixture resolution in pharmaceutical samples testify to the usefulness of the proposed sensor. Received: 20 April 1999 / Revised: 7 June 1999 / Accepted: 12 June 1999  相似文献   

18.
 Simple, rapid, sensitive and selective methods for the determination of Cr(III) and W(VI) with flavonol derivatives in the presence of surface-active agents are proposed. In the pH ranges 3.4–4.2 and 1.9–2.5, the molar absorptivities of Cr(III)-morin-emulsifier S (EFA) and W(VI)-morin-polyvinylpyrrolidone (PVP) systems are 1.13×105 and 2.13×104 L mol−1 cm−1 at 435 and 415 nm, respectively. The Cr(III)-quercetin-PVP and W(VI)-quercetin-cetylpyridinium bromide (CPB) systems are formed in the pH ranges 4–4.6 and 2.2–2.8 with molar absorptivities 1.02×105 and 9.02×104 L. mol−1 cm−1 at 441 and 419 nm, respectively. The linear dynamic ranges for the determination of Cr(III) and W(VI) with morin in the presence of EFA and PVP are 0.03–0.46 and 0.71–8.1 μg mL−1, respectively. The corresponding ranges with quercetin are 0.04–0.54 and 0.14–2.1 μg mL−1 of Cr(III) and W(VI), respectively. The r.s.d (n = 10) for the determination of 0.25 and 3.7 μg mL−1 of Cr(III) and W(VI) with morin and their detection limits are 0.88 and 0.99% and 0.016 and 0.63 μg mL−1, respectively. Using quercetin, the r.s.d (n = 10) for 0.22 and 1.2 μg mL−1 of Cr(III) and W(VI) and their detection limits are 0.92 and 0.91% and 0.015 and 0.08 μg mL−1, respectively. The critical evaluation of the proposed methods is performed by statistical analysis of the experimental data. The proposed methods are applied to determine Cr in steel, non-ferrous alloys, wastewater and mud filtrate and to the determination of W in steel. Received March 8, 1999. Revision January 21, 2000.  相似文献   

19.
The application of an ion-guiding gas-filled hexapole collision/reaction cell in ICP-MS has been studied to characterize the analytical figures of merit that can be achieved with this approach. For the elements investigated, application of a buffer and a reaction gas resulted in improved sensitivities which are lowest for Be with about 7 · 107 cps per μg mL–1 and highest for Ba with about ?6 · 108 cps per μg mL–1. Relative standard deviations (RSD) < 0.1% were obtained. Application of the reaction gas H2 was used to suppress polyatomic ions caused by argon. The reduction amounted up to four orders of magnitude so that elements such as Ca, K, Cr, Fe, As and Se could be analyzed in nitric and hydrochloric acid or in methanol. Detection limits of 6 pg mL–1 for Cr in 2% methanol, 23 pg mL–1 for As and 9 pg mL–1 for Se in 0.28 M HCl were achieved. For other elements detection limits ?< 1 pg mL–1 were realized in the medium and high mass range. Accuracy was proved using the NIST 1643d standard reference material. Received: 10 May 1999 / Revised: 4 June 1999 / Accepted: 12 June 1999  相似文献   

20.
A rapid, accurate, and precise method is described for the determination of Pb in wine using continuous-flow hydride generation atomic fluorescence spectrometry (CF-HGAFS). Sample pretreatment consists of ten-fold dilution of wine followed by direct plumbane generation in the presence of 0.1 mol L−1 HCl and 1% m/v K3[Fe(CN)6] with 1% m/v NaBH4 as reducing agent. An aqueous standard calibration curve is recommended for Pb quantification in wine sample. The method provides a limit of detection and a limit of quantification of 0.3 μg L−1 and 1 μg L−1, respectively. The relative standard deviation varies between 2–6% (within-run) and 4–11% (between-run) at 3–30 μg L−1 Pb levels in wine. Good agreement has been demonstrated between results obtained by CF-HGAFS and direct electrothermal atomic absorption spectrometry in analyses of red and white wines within the concentration range of 9.2–25.8 μg L−1 Pb.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号