首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In recent years, the sensor array has attracted much attention in the field of complex system analysis on the basis of its good selectivity and easy operation. Many optical colorimetric sensor arrays are designed to analyze multi-target analytes due to the good sensitivity of optical signal. In this review, we introduce the targeting analytes, sensing mechanisms and data processing methods of the optical colorimetric sensor array based on optical probes (including organic molecular probes, polymer materials and nanomaterials). The research progress in the detection of metal ions, anions, toxic gases, organic compounds, biomolecules and living organisms (such as DNA, amino acids, proteins, microbes and cells) and actual sample mixtures are summarized here. The review illustrates the types, application advantages and development prospects of the optical colorimetric sensor array to help broad readers to understand the research progress in the application of chemical sensor array.  相似文献   

2.
Optical fibres provide a universal sensing platform as they are easily integrated with a multitude of different sensing schemes. Such schemes enable the preparation of a multitude of sensors from relatively straightforward pH sensors, to more complex ones, including artificial olfaction sensors, high-density oligonucleotide arrays, and high-throughput cell-based arrays. Imaging fibre bundles comprised of thousands of fused optical fibres are the basis for an optically connected, individually addressable parallel sensing platform. Fibre optic imaging bundles possess miniature feature sizes (3-10 micron diameter fibres), allowing high-density sensor packing (approximately 2 x 10(7) sensors per cm2). Imaging fibre bundles transmit coherent images enabling combined imaging and sensing, relating the responses monitored by the sensor to observable physical changes. The individual fibre cores can also be selectively etched to form a high-density microwell array capable of housing complementary sized microsensors. The miniature feature sizes facilitate a faster response and more sensitive measurement capabilities. The platform is extremely versatile in its sensing design, allowing the sensing scheme to be tailored to fit the experimental design, whether for monitoring single analytes or more complex multiplexed assays. A number of sensing schemes and applications are described in this review.  相似文献   

3.
Tang Y  Tao Z  Bukowski RM  Tehan EC  Karri S  Titus AH  Bright FV 《The Analyst》2006,131(10):1129-1136
The objective of this research is to develop arrays of tuned chemical sensors wherein each sensor element responds to a particular target analyte in a unique manner. By creating sol-gel-derived xerogels that are co-doped with two luminophores at a range of molar ratios, we can form suites of sensor elements that can exhibit a continuum of response profiles. We trained an artificial neural network (ANN) to "learn" to identify the optical outputs from these xerogel-based sensor arrays. By using the ANN in concert with our tailored sensor arrays we obtained a 5-10 fold improvement in accuracy and precision for quantifying O2 in unknown samples. We also explored the response characteristics of these types of sensor elements after they had been contacted with rat plasma/blood. Contact with plasma/blood caused approximately 15% of the luminophore molecules within the xerogels to become non-responsive to O2. This behavior is consistent with rat albumin blocking certain pore sub-populations within the mesoporous xerogel matrix thereby limiting O2 access to the luminophores.  相似文献   

4.
The focus of this study was to demonstrate that, in the luminescent sensors, the signal transduction may possibly be the most important part in the sensing process. Rational design of fluorescent sensor arrays for cations utilizing extended conjugated chromophores attached to 8-hydroxyquinoline is reported. All of the optical sensors utilized in the arrays comprise the same 8-hydroxyquinoline (8-HQ) receptor and various conjugated chromophores to yield a different response to various metal cations. This is because the conjugated chromophores attached to the receptor are partially quenched in their resting state, and upon the cation coordination by the 8-HQ, the resulting metalloquinolinolate complex displays a change in fluorescence. A delicate balance of conjugation, fluorescence enhancement, energy transfer, and a heavy metal quenching effect results in a fingerprint-like pattern of responses for each sensor-cation complex. Principal component analysis (PCA) and linear discriminant analysis (LDA) are used to demonstrate the contribution of individual sensors within the array, information that may be used to design sensor arrays with the smallest number of sensor elements. This approach allows discriminating between 10 cations by as few as two or even one sensor element. Examples of arrays comprising various numbers of sensor elements and their utility in qualitative identification of Ca(2+), Mg(2+), Cd(2+), Hg(2+), Co(2+), Zn(2+), Cu(2+), Ni(2+), Al(3+), and Ga(3+) ions are presented. A two-member array was found to identify 11 analytes with 100% accuracy. Also the best two of the sensors were tested alone and both were found to be able to discriminate among the samples with 99% and 96% accuracy, respectively. To illustrate the utility of this approach to a real-world application, identification of enhanced soft drinks based on their Ca(2+), Mg(2+), and Zn(2+) cation content was performed. The same approach to reducing array elements was used to construct three- and two-member arrays capable of identifying these complex analytes with 100% accuracy.  相似文献   

5.
Nowadays there exists a large variety of ion sensors based on polymeric or solid-state membranes that can be used in a sensor array format in many analytical applications. This review aims at providing a critical overview of the distinct approaches that were developed to build and use potentiometric sensor arrays based on different transduction principles, such as classical ion-selective electrodes (ISEs) with polymer or solid-state membranes, solid-contact electrodes (SCE) including coated wire electrodes (CWE), ion-sensitive field-effect transistors (ISFETs) and light addressable potentiometric sensors (LAPS). Analysing latest publications on potentiometric sensor arrays development and applications certain problems are outlined and trends are discussed.  相似文献   

6.
Here we demonstrate design, fabrication, and testing of electronic sensor array based on single-walled carbon nanotubes (SWNTs). Multiple sensor elements consisting of isolated networks of SWNTs were integrated into Si chips by chemical vapor deposition (CVD) and photolithography processes. For chemical selectivity, SWNTs were decorated with metal nanoparticles. The differences in catalytic activity of 18 catalytic metals for detection of H(2), CH(4), CO, and H(2)S gases were observed. Furthermore, a sensor array was fabricated by site-selective electroplating of Pd, Pt, Rh, and Au metals on isolated SWNT networks located on a single chip. The resulting electronic sensor array, which was comprised of several functional SWNT network sensors, was exposed to a randomized series of toxic/combustible gases. Electronic responses of all sensor elements were recorded and the sensor array data was analyzed using pattern-recognition analysis tools. Applications of these small-size, low-power, electronic sensor arrays are in the detection and identification of toxic/combustible gases for personal safety and air pollution monitoring.  相似文献   

7.
Reddy K  Guo Y  Liu J  Lee W  Oo MK  Fan X 《Lab on a chip》2012,12(5):901-905
We developed and characterized a rapid, sensitive and integrated optical vapor sensor array for micro-gas chromatography (μGC) applications. The sensor is based on the Fabry-Pérot (FP) interferometer formed by a micrometre-thin vapor-sensitive polymer layer coated on a silicon wafer. The thickness and the refractive index of the polymer vary in response to the vapor analyte, resulting in a change in the reflected intensity of the laser impinged on the sensor. In our study, four different polymers were coated on four wells pre-etched on a silicon wafer to form a spatially separated sensor array. A CMOS imager was employed to simultaneously monitor the polymers' response, thus enabling multiplexed detection of a vapor analyte passing through the GC column. A sub-second detection time was demonstrated. In addition, a sub-picogram detection limit was achieved, representing orders of magnitude improvement over the on-chip vapor sensors previously reported.  相似文献   

8.
9.
An application of gas sensors for rapid bioanalysis is presented. An array of temperature-modulated semiconductor sensors was used to characterize the headspace above a cell culture. Recombinant Saccharomyces cerevisiae yeast cells, able to respond to 17-estradiol by producing a reporter protein, were used as a model system. Yeast cells had the DNA sequence of the human estrogen receptor stably integrated into the genome, and contained expression plasmids carrying estrogen-responsive sequences and the reporter gene lac-Z, encoding the enzyme -galactosidase. The sensor-response profiles showed small but noticeable discrimination between cell samples induced with 17-estradiol and non-induced cell samples. The sensor array was capable of detecting changes in the volatile organic compound composition of the headspace above the cultured cells, which can be associated with metabolic changes induced by a chemical compound. This finding suggests the possibility of using cross-selective gas-sensor arrays for analysis of drugs or bioactive molecules through their interaction with cell systems, with the advantage of providing information on their bioavailability.  相似文献   

10.
Planar waveguide optical ring resonators have shown great potential as compact and sensitive biochemical sensors. Advances in integrated optics based on Si technologies have allowed researchers to integrate multiple micron-sized ring resonator sensors with other optical and fluidic functions on Si chips using mass production techniques. Recent demonstrations of clinically relevant analyte detection by MRR sensor arrays have moved this technology closer to commercialization. Here, a survey of the development of microring sensor arrays for lab-on-a-chip applications is presented and illustrated with state-of-the-art examples.  相似文献   

11.
Interest in the use of the optical properties of chemical indicators is growing steadily. Among the optical methods that can be used to capture changes in sensing layers, those producing images of large-area devices are particularly interesting for chemical sensor array development. Until now, few studies addressed the characterization of image sensors from the point of view of their chemical sensor application. In this paper, a method to evaluate such performance is proposed. It is based on the simultaneous measurement of absorption events in a metalloporphyrin layer with an image sensor and a quartz microbalance (QMB). Exploiting the well-known behaviour of QMB, comparison of signals enables estimation of the minimum amount of absorbed molecules that the image sensor can detect. Results indicate that at the single pixel level a standard image sensor (for example a webcam) can easily detect femtomoles of absorbed molecules. It should therefore be possible to design sensor arrays in which the pixels of images of large-area sensing layers are regarded as individual chemical sensors providing a ready and simple method for large sensor array development.  相似文献   

12.
Changes in colors of an array of optical sensors that responds in full pH range were recorded using a CCD camera. The data of the camera were transferred to the computer through a capture card. Simple software was written to read the specific color of each sensor. In order to associate sensor array responses with pH values, a number of different mathematics and chemometrics methods were investigated and compared. The results show that the use of “Microsoft Excel's Solver” provides results which are in very good agreement with those obtained with chemometric methods such as artificial neural network (ANN) and partial least square (PLS) methods.  相似文献   

13.
Ratiometric fluorescence-based sensors are widely sought after because they can effectively convert even relatively small changes in optical output into a strong and easy-to-read signal. However, ratiometric sensor molecules are usually difficult to make. We present a proof-of-principle experiment that shows that efficient ratiometric sensing may be achieved by an array of two chromophores, one providing an on-to-off response and the second yielding an off-to-on response in a complementary fashion. In the case that both chromophores emit light of different color, the result is a switching of colors that may be utilized in the same way as from a true ratiometric probe. The chromophore array comprises two sensor elements: i) a polyurethane membrane with embedded N-anthracen-9-yl-methyl-N-7-nitrobenzoxa-[1,2,5]diazo-4-yl-N',N'-dimethylethylenediamine hydrochloride and ii) a membrane with N,N-dimethyl-N'-(9-methylanthracenyl)ethylenediamine. A combination of photoinduced electron transfer (PET) and fluorescence resonance energy transfer (FRET) allows for green-to-blue emission switching in the presence of Zn(II) ions. The sensing experiments carried out with different Zn(II) salts at controlled pH revealed that the degree of color switching in the individual sensor elements depends on both the presence of Zn(II) ions and the counter anion. These results suggest that sensing of both cations and anions may perhaps be extended to different cation-anion pairs.  相似文献   

14.
We report a new, solid-state, integrated optical array sensor platform. By using pin printing technology in concert with sol-gel-processing methods, we form discrete xerogel-based microsensor elements that are on the order of 100 μm in diameter and 1 μm thick directly on the face of a light emitting diode (LED). The LED serves as the light source to excite chemically responsive luminophores sequestered within the doped xerogel microsensors and the analyte-dependent emission from within the doped xerogel is detected with a charge coupled device (CCD). We overcome the problem of background illumination from the LED reaching the CCD and the associated biasing that results by coating the LED first with a thin layer of blue paint. The thin paint layer serves as an optical filter, knocking out the LEDs red-edge spectral tail. The problem of the spatially-dependent fluence across the LED face is solved entirely by performing ratiometric measurements. We illustrate the performance of the new sensor scheme by forming an array of 100 discrete O2-responsive sensing elements on the face of a single LED. The combination of pin printing with an integrated sensor and light source platform results in a rapid method of forming (∼1 s per sensor element) reusable sensor arrays. The entire sensor array can be calibrated using just one sensor element. Array-to-array reproducibly is <8%. Arrays can be formed using single or multiple pins with indistinguishable analytical performance.  相似文献   

15.
Optical array‐based sensors are attractive candidates for the detection of various bio‐analytes due to their convenient fabrication and measurements. For array‐based sensors, multichannel arrays are more advantageous and used frequently in many electronic sensors. But most reported optically array based sensors are constructed on a single channel array. This difficulty is mainly instigated from the overlap in optical responses. In this report we have used nano‐graphene oxide (nGO) and suitable fluorophores as sensor elements to construct a multichannel sensor array for the detection of protein analytes. By using the optimized multichannel array we are able to detect different proteins and mixtures of proteins with 100 % classification accuracy at sub‐nanomolar concentration. This modified method expedites the sensing analysis as well as minimizes the use of both analyte and sensor elements in array‐based protein sensing. We have also used this system for the single channel array‐based sensing to compare the sensitivity and the efficacy of these two systems for other applications. This work demonstrated an intrinsic trade‐off associated with these two methods which may be necessary to balance for array‐based analyte detections.  相似文献   

16.
The fluorophore, Nile Red, effectively works as a polarity-sensitive fluorescence probe. We have designed a new nucleoside modified by Nile Red for examining the change in the polarity of the microenvironment surrounding DNA. We synthesized a Nile Red nucleoside (1), formed by replacing nucleobases with Nile Red, through the coupling of a 2-hydroxylated Nile Red derivative and 1,2-dideoxyglycan. This nucleoside showed a high solvatofluorochromicity. The fluorescence of 1 incorporated into DNA was greatly shifted to shorter wavelength by the addition of beta-cyclodextrin. The photophysical function of the Nile Red nucleoside will be a good optical indicator for monitoring the change in the micropolarity properties at a specific site on target sequences with interaction between DNA and DNA-binding molecules.  相似文献   

17.
Piezoelectric quartz crystal sensors were developed using lipids with various properties for highly sensitive detection of chemical vapors. Lipids with varying lengths of alkyl chains were coated onto 10 MHz AT-cut quartz crystal resonators and the response of these modified crystals to chemical vapors were measured. It was shown that hydrophilic compounds, such as ethanol and methanol, could be recognized efficiently by lipids having shorter alkyl chains, whereas lipids with longer alkyl chains showed affinity to more hydrophobic vapors, such as toluene, hexane and cyclohexane. Frequency changes caused by adsorption of alcohols could be enhanced when cholesterol was co-immobilized in the lipid layer. To confirm the assumption that the sensor-response might be affected by the properties of lipids derived from acyl chains, we have examined the effects of two types of newly synthesized unusual lipids on sensor response. When lipids having one triple bond each at different positions on their alkyl chains were coated onto quartz crystals separately, lower responses were observed compared to responses obtained for a sensor with immobilized, saturated phosphatidylcholine. Lipids containing -branched acyl chains, however, showed good affinity for organic vapors, and sensor responses improved 4–5-fold. Moreover, these sensors were shown to have sensitivity of the same order as the humans' sense of smell (10−5–10−6 w/w in liquid paraffin) when measured using standard odorants (isovaleric acid, skatole, etc.) for an olfactometry established in Japan.  相似文献   

18.
It is shown that the sensor arrays can acquire more information on a given sample than an individual sensor. The main classes of gas-sensing materials include metal-oxide semiconductors. Gas sensors based on chemiresistive semiconducting metal-oxides have many potential benefits including, their very low cost, fast response, recovery time, simple electronic interface, ease of use, and ability to detect a large analytes. Recent advances in gas sensor arrays have shown the capability to incorporate nanomaterial based cross-reactive array. In this way it is possible to increase the surface/volume ratio of the sensing layer. Therefore the surface scattering is better influenced by adsorbed species and change in sensor conductivity is higher. Also the sensitivity of semiconductor oxide materials can be improved by using of nanoparticles. Gas sensor arrays based on nanotechnology can rapidly, sensitively, and selectively detect target molecules.  相似文献   

19.
Gas sensor arrays often lack discrimination power to different analytes and robustness to interferants, limiting their success outside of research laboratories. This is primarily due to the widely sensitive (thus weakly-selective) nature of the constituent sensors. Here, the effect of orthogonality on array accuracy and precision by selective sensor design is investigated. Therefore, arrays of (2–5) selective and non-selective sensors are formed by systematically altering array size and composition. Their performance is evaluated with 60 random combinations of ammonia, acetone and ethanol at ppb to low ppm concentrations. Best analyte predictions with high coefficients of determination (R2) of 0.96 for ammonia, 0.99 for acetone and 0.88 for ethanol are obtained with an array featuring high degree of orthogonality. This is achieved by using distinctly selective sensors (Si:MoO3 for ammonia and Si:WO3 for acetone together with Si:SnO2) that improve discrimination power and stability of the regression coefficients. On the other hand, arrays with collinear sensors (Pd:SnO2, Pt:SnO2 and Si:SnO2) hardly improve gas predictions having R2 of 0.01, 0.86 and 0.28 for ammonia, acetone and ethanol, respectively. Sometimes they even exhibited lower coefficient of determination than single sensors as a Si:MoO3 sensor alone predicts ammonia better with a R2 of 0.68.
Graphical abstract Conventional arrays (red) with weakly-selective sensors span a significantly smaller volume in the analyte space than arrays containing distinctly-selective sensors (orthogonal array, green). Orthogonal arrays feature better accuracy and precision than conventional arrays in mixtures of ammonia, acetone and ethanol.
  相似文献   

20.
This article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted of five commercially available gas sensors: three metal oxide semiconductor (MOS) chemical sensors and two electrochemical ones. To calibrate and validate the matrix, odor concentrations were determined within the composting yard using the field olfactometry technique. Five mathematical models (e.g., multiple linear regression and principal component regression) were used as calibration methods. Two methods were used to extract signals from the matrix: maximum signal values from individual sensors and the logarithm of the ratio of the maximum signal to the sensor baseline. The developed models were used to determine the predicted odor concentrations. The selection of the optimal model was based on the compatibility with olfactometric measurements, taking the mean square error as a criterion and their accordance with the proposed OAQII. For the first method of extracting signals from the matrix, the best model was characterized by RMSE equal to 8.092 and consistency in indices at the level of 0.85. In the case of the logarithmic approach, these values were 4.220 and 0.98, respectively. The obtained results allow to conclude that gas sensor arrays can be successfully used for air quality monitoring; however, the key issues are data processing and the selection of an appropriate mathematical model.  相似文献   