首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
For measurement of biomarkers from polycyclic aromatic hydrocarbon (PAH) exposure, an analytical method is described quantifying hydroxylated PAH (OH-PAH) in urine samples. This method determined monohydroxy metabolites of naphthalene, fluorene, phenanthrene, fluoranthene, pyrene, chrysene, benzo[c]phenanthrene, and benz[a]anthracene. The sample preparation consisted of enzymatic hydrolysis, solid-phase extraction and derivatization with a silylating reagent. Five carbon-13 labeled standards were used for isotope dilution. Analytes were separated by gas chromatography (GC) and quantified with high-resolution mass spectrometry (HRMS). This method produced good recoveries (41-70%), linearity, and specificity. Data were corrected for blank levels from the naphthalene, fluorene, and phenanthrene metabolites. Method detection limits ranged from 2 ng L(-1) for 1-hydroxypyrene to 43.5 ng L(-1) for 1-hydroxynaphthalene. Using quality control charts from two urine pools, the method can be readily applied to biomonitoring PAH exposure.  相似文献   

2.
3.
The occurrence of polycyclic aromatic hydrocarbons (PAHs) in nine edible oils of three categories of oil samples, such as soy bean oil, mustard oil and coconut oil, has been studied to determine the contamination degree of this type of oil samples. Eight major carcinogenic polycyclic aromatic hydrocarbons (PAHs), such as naphthalene, anthracene, phenanthrene, fluorene, pyrene, crysene, benzo(a)pyrene and benzo(a)anthracene, were identified and quantified in the extract of edible oils collected from Bangladeshi Markets by gas chromatography and mass spectroscopy. All of the carcinogenic PAHs are not present in the edible oils. A few of the carcinogenic PAHs are present in the oils but it is within the permissible limit. The results for the recoveries of naphthalene, fluorene, phenanthrene, anthracene, pyrene, crysene, benzo(a)anthracene and benzo(a)pyrene were in the range of 56–84%. The limit of detection (LOD) of the GC–MS method, established at signals three times that of the noise for naphthalene, fluorene, phenanthrene, anthracene, pyrene, crysene, benzo(a)anthracene and benzo(a)pyrene, was 2.0–2.5 ng, respectively.  相似文献   

4.
This paper presents the phosphorescence characterization of polycyclic aromatic hydrocarbons (PAHs) on solid-surface for obtaining new flow-through phosphorescence optosensors for PAHs-based on-line, immobilized onto a non-ionic resin solid support coupled to a continuous flow system and the applications for the selective determination of benzo(a)pyrene (BaP). The phosphorescent characterization of 15 PAHs, described as major pollutants by the Environmental Protection Agency (EPA) (naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, chrysene, benzo(a)anthracene, benzo(k)fluoranthene, benzo(b)fluoranthene, benzo(a)pyrene, indeno(1,2,3-cd)pyrene, benzo(g,h,i)perylene and dibenzo(a,h)anthracene) has been carried out. The experimental variables (heavy atom, deoxygenation and organic solvent in samples) for obtaining different possibilities for developing mono and multi-parameter PAH sensors and the conditions for PAH screening have been carefully studied and the experimental conditions to determination of BaP in presence of other PAHs in water samples have been optimized.  相似文献   

5.
Three online solid phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) method examples are presented where two different types of chromatographic columns or solvent systems were coupled to meet specific analytical objectives: (i) SPE of target analytes by restricted access media from high ionic strength urine matrix was coupled with reversed phase LC-MS/MS conditions accommodating high ionization potentials of the analytes (urinary bisphenol A and other phenolic derivatives); (ii) strong cation exchange SPE of analytes of diverse polarity and pK(a) was coupled with reversed phase LC-MS/MS analysis (urinary atrazine metabolites); (iii) pre-concentration of low pg per sample analytes by weak anion exchange SPE was hyphenated with ion pair LC-MS analysis (intracellular nucleotide triphosphate analogs). With these examples we suggest a conductive generic work flow for the development of online SPE-LC-MS methods and show how advanced commercial LC devices and software allow for the design of complex yet highly versatile analytical separation systems suited to the unique physicochemical properties of the target analytes.  相似文献   

6.
A sensitive and reliable analytical method was developed for the simultaneous extraction of PAHs and total fats and their determination in the human milk. The method involved a liquid-liquid extraction of PAHs and fats, followed by the gravimetric determination of the latter. PAHs were separated from lipids by size exclusion chromatography eluting with methylene chloride and analysed by gaschromatography coupled with mass spectrometry (GC/MS). The recovery of analytes was in the range of 42-101% and agreed well with their boiling temperatures (R2=0.779). Precision of the method was found between 7.6 and 19%. Quantification and detection limits for individual PAHs ranged from 0.011 to 0.032 and from 0.006 to 0.022 microg/Kg milk (wet weight), respectively. Quantification limit for the total fat determination was 0.26 g/Kg milk (wet weight). This procedure, applied to milk samples of ten healthy, non-smoking, Italian primiparae, living in rural or low-traffic zones, allowed for the identification and quantitative determination of naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo(a)anthracene, benzo(b)fluoranthene and benzo(k)fluoranthene in the mean concentration range 0.114-6.95 microg/Kg milk (wet weight). The most volatile compounds, which were not investigated elsewhere, were found at much higher concentrations than those observed for the others. No relation was found between PAH and total fat concentrations.  相似文献   

7.
焦炉烟气中全量多环芳烃分析方法   总被引:5,自引:1,他引:5  
张兰英  徐景梅 《分析化学》1997,25(11):1264-1269
报道了利用处在制串联采样装置。优选出了比较理想的前处理方法,并用此方法对焦炉烟气中的全量多环芳烃进行了研究。滤膜颗粒物中的多环芳烃有6途中 ,聚氨酯泡沫吸附剂中有49种。  相似文献   

8.
This paper presents the characterization of polycyclic aromatic hydrocarbons (PAHs) in solid-surface fluorescence as the first step for obtaining new optical sensors for PAHs screening. The fluorescence properties of the EPA-PAHs (naphthalene, acenaphthene, acenaphthylene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, chrysene, benzo[a]anthracene, benzo[k]fluoranthene, benzo[b]fluoranthene, benzo[a]pyrene, indeno [1,2,3-cd]pyrene, benzo[g,h,i]perylene and dibenzo[a,h]anthracene) on five types of solid-surfaces were evaluated. The experimental variables (pH and percentage of organic solvent in samples) were studied, obtaining different possibilities for making individual sensors for some of these PAHs and the best conditions for developing sensors for PAH screening were also studied.  相似文献   

9.
Barbeau D  Maître A  Marques M 《The Analyst》2011,136(6):1183-1191
Many workers and also the general population are exposed to polycyclic aromatic hydrocarbons (PAHs), and benzo[a]pyrene (BaP) was recently classified as carcinogenic for humans (group 1) by the International Agency for Research on Cancer. Biomonitoring of PAHs exposure is usually performed by urinary 1-hydroxypyrene (1-OHP) analysis. 1-OHP is a metabolite of pyrene, a non-carcinogenic PAH. In this work, we developed a very simple but highly sensitive analytical method of quantifying one urinary metabolite of BaP, 3-hydroxybenzo[a]pyrene (3-OHBaP), to evaluate carcinogenic PAHs exposure. After hydrolysis of 10 mL urine for two hours and concentration by automated off-line solid phase extraction, the sample was injected in a column-switching high-performance liquid chromatography fluorescence detection system. The limit of quantification was 0.2 pmol L(-1) (0.05 ng L(-1)) and the limit of detection was estimated at 0.07 pmol L(-1) (0.02 ng L(-1)). Linearity was established for 3-OHBaP concentrations ranging from 0.4 to 74.5 pmol L(-1) (0.1 to 20 ng L(-1)). Relative within-day standard deviation was less than 3% and relative between-day standard deviation was less than 4%. In non-occupationally exposed subjects, median concentrations for smokers compared with non-smokers were 3.5 times higher for 1-OHP (p<0.001) and 2 times higher for 3-OHBaP (p<0.05). The two urinary biomarkers were correlated in smokers (ρ=0.636; p<0.05; n=10) but not in non-smokers (ρ=0.09; p>0.05; n=21).  相似文献   

10.
S-phenylmercapturic acid is widely accepted as a specific biomarker for the evaluation of benzene exposure. Here, we describe a fast, specific and sensitive high-performance liquid achromatography coupled with tandem mass spectrometry (LC-MS/MS) method that has been developed and validated for the determination of S-phenylmercapturic acid in human urine. Isotope-labeled S-phenylmercapturic acid-d5 was used as internal standard to improve the method ruggedness. The fully automated solid-phase extraction method on a 96-well Oasis MAX (mix-mode anion exchange) plate was employed to clean up the urine samples before analysis. The rapid LC-MS/MS analysis of extracted samples was achieved on a Genesis C18 column with a run time of only 3 min. Negative electrospray ionization with multiple reaction monitoring (ESI-MRM) mode was used to detect S-phenylmercapturic acid (m/z 238 --> 109) and S-phenylmercapturic acid -d5 (m/z 243 --> 114). The method fulfils all the standard requirements of method validation. The calibration curve was linear within the concentration range 0.400-200 ng/mL. The method performed accurately and precisely in validation with <7.5% relative error and <6.5% relative standard deviation of quality control samples. The method efficacy was also verified by the analysis of urine samples from 12 smokers and 12 non-smokers. With the fully automated sample cleanup procedure and the fast LC-MS/MS analysis, a sample analysis throughput of 384 samples per day could be achieved.  相似文献   

11.
Volatile organic compounds (VOCs) are ubiquitous in the environment, originating from many different natural and anthropogenic sources, including tobacco smoke. Long-term exposure to certain VOCs may increase the risk for cancer, birth defects, and neurocognitive impairment. Therefore, VOC exposure is an area of significant public health concern. Urinary VOC metabolites are useful biomarkers for assessing VOC exposure because of non-invasiveness of sampling and longer physiological half-lives of urinary metabolites compared with VOCs in blood and breath. We developed a method using reversed-phase ultra high performance liquid chromatography (UPLC) coupled with electrospray ionization tandem mass spectrometry (ESI/MSMS) to simultaneously quantify 28 urinary VOC metabolites as biomarkers of exposure. We describe a method that monitors metabolites of acrolein, acrylamide, acrylonitrile, benzene, 1-bromopropane, 1,3-butadiene, carbon-disulfide, crotonaldehyde, cyanide, N,N-dimethylformamide, ethylbenzene, ethylene oxide, propylene oxide, styrene, tetrachloroethylene, toluene, trichloroethylene, vinyl chloride and xylene. The method is accurate (mean accuracy for spiked matrix ranged from 84 to104%), sensitive (limit of detection ranged from 0.5 to 20 ng mL−1) and precise (the relative standard deviations ranged from 2.5 to 11%). We applied this method to urine samples collected from 1203 non-smokers and 347 smokers and demonstrated that smokers have significantly elevated levels of tobacco-related biomarkers compared to non-smokers. We found significant (p < 0.0001) correlations between serum cotinine and most of the tobacco-related biomarkers measured. These findings confirm that this method can effectively quantify urinary VOC metabolites in a population exposed to volatile organics.  相似文献   

12.
4‐(Methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone (NNK) is a carcinogenic nitrosamine produced upon curing tobacco. It is present in tobacco smoke and undergoes metabolism to 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanol (NNAL) in the lungs. NNAL undergoes further uridine diphosphate glucuronosyltransferase (UGT)‐mediated metabolism to give N‐ and O‐glucuronide metabolites, which together with free (non‐conjugated) NNAL are then excreted in the urine. The ability to conduct validated analyses of free and conjugated NNAL in human urine is important in order to assess inter‐individual differences in lung cancer risk from exposure to cigarette smoke. The use of stable isotope dilution (SID) methodology in combination with liquid chromatography/multiple reaction monitoring/mass spectrometry (LC/MRM‐MS) provides the highest bioanalytical specificity possible for such analyses. We describe a novel derivatization procedure, which results in the formation of a pre‐ionized N‐propyl‐NNAL derivative. The increased LC/MS sensitivity arising from this derivative then makes it possible to analyze free NNAL in only 0.25 mL urine. This substantial reduction in urine volume when compared with other methods that have been developed will help preserve the limited amounts of stored urine samples that are available from on‐going longitudinal biomarker studies. The new high sensitivity SID LC/MRM‐MS assay was employed to determine free and conjugated NNAL concentrations in urine samples from 60 individual disease‐free smokers. Effects of inter‐individual differences in urinary creatinine clearance on NNAL concentrations were then assessed and three metabolizer phenotypes were identified in the 60 subjects from the ratio of urinary NNAL glucuronides/free NNAL. Poor metabolizers (PMs, 14 subjects) with a ratio of NNAL glucuronides/free NNAL <2 (mean = 1.3), intermediate metabolizers (IMs, 36 subjects) with a ratio between 2 and 5 (mean = 3.4), and extensive metabolizers (EMs, 10 subjects) with a ratio >5 (mean = 11.1). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Diesel fuels from different parts of the UK have been analyzed for polycyclic aromatic hydrocarbons (PAH), nitrogen-containing PAH, and sulfur-containing PAH using capillary column GC with simultaneous parallel triple detection. The concentrations of polyaromatic compounds (PAC) were high and showed considerable variability amongst the fuels. The PAH are mainly naphthalene, fluorene, and phenanthrene and their alkylated homologs; the PANH are mainly carbazole and its methyl derivatives; the PASH are mainly dibenzothiophene and its methyl derivatives.  相似文献   

14.
A pressurized liquid extraction (PLE) method has been optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil samples and it was compared with ultrasonic extraction. The extraction step was followed by gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS/MS) analysis. Parameters such as type of solvent, extraction time, extraction temperature and number of extractions were optimized. There were no significant differences among the two extraction methods although better extraction efficiencies were obtained when PLE was used, minimizing extraction time and solvent consumption. PLE procedure was validated, obtaining limits of detection (LODs) ranging from 0.02 to 0.75 μg kg−1 and limits of quantification (LOQs) ranging from 0.07 to 2.50 μg kg−1 for the selected PAHs. Recoveries were in the range of 59-110%, except for naphthalene, which was the most volatile PAH. Finally, the method was applied to real soil samples from Southeast of Spain. PAHs concentrations were low, and phenanthrene, pyrene, fluorene, benzo[a]pyrene and chrysene were the most frequently detected analytes in the samples.  相似文献   

15.
建立了固相萃取-液相色谱-串联质谱同时测定尿中2-羟基萘、1-羟基萘、2-羟基芴、3-羟基菲、1-羟基芘等9种多环芳烃代谢物的液相色谱-串联质谱测定方法。尿样中结合态的多环芳烃代谢物在β-葡萄糖苷酸酶-芳基硫酸酯酶缓冲液(pH 5.0)作用下,于37℃水浴中避光水解4 h后,以C18固相萃取小柱富集、净化,以甲醇洗脱,采用Waters Symmetry C18色谱柱,流动相为乙腈-0.2%氨水(72∶27,V/V)等度淋洗分离后进入质谱测定。在喷雾电压4 kV,毛细管温度300℃下,以3-羟基菲13C为内标,采用SRM模式负离子扫描方式测定,内标法定量。9种多环芳烃代谢物在尿中的线性范围为0.90~100μg/L;相关系数为0.9970~0.9990;回收率为79.0%~119.8%;相对标准偏差为4.3%~12.4%;检出限为0.04~0.90μg/L;结果表明,本方法可用于尿中9种多环芳烃代谢物的测定。  相似文献   

16.
We describe a sensitive and rapid method to assay urinary cotinine levels among non-smokers using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) and its application in studies assessing exposures to second hand smoke (SHS). Cotinine was initially extracted from 1 ml of urine with methylene chloride by using a liquid-liquid extraction Chem Elut™ column. The extracted sample was further separated by using a BetaBasic C18 column (1 mm × 150 mm, 3 μm) with isocratic elution (60:40 acetonitrile and 5 mM ammonium acetate at pH 5), and then examined using a triple quadrupole mass spectrometer with an electrospray ionization (ESI) source in multiple-reaction-monitoring (MRM) mode. The elution of cotinine from the LC column took approximately 2.3 min and the detection of cotinine by ESI/MS/MS provided a limit of detection (LOD) of 0.3 ng/ml. The ESI/MS/MS detection was able to easily distinguish between cotinine and nicotine. This method, validated using a cotinine concentration range from 0.8 to 102.4 ng/ml, was successfully applied in a cross-sectional study examining differences in levels and sources of second hand smoke (SHS) exposure among non-smokers. Self-reported measures of SHS exposure were significantly associated with urinary cotinine levels. This urinary cotinine assay using LC-ESI/MS/MS provides a robust, high throughput and very sensitive method for the evaluation of SHS exposure for use in epidemiologic and clinical research studies.  相似文献   

17.
《Analytical letters》2012,45(14):3077-3092
ABSTRACT

The application of trap and desorption GC/MS to monitoring of sixteen PAHs in the exhaust emissions from motorcycles was investigated. The time of sampling and analysis for one sample is in 40 minutes. The relative standard deviations were estimated from 20% to 34% for monitoring the total concentrations of PAHs from the emissions of motorcycles. The PAH concentrations appeared to show distinct variations with the stroke, engine size and the aging of motorcycles. The predominate of PAHs in the emissions of motorcycle were naphthalene, fluorene, anthracene, fluoranthene and pyrene. Naphthalene exhibited the highest concentration that was obtained over 79% of the total concentration of sixteen PAHs in the emissions of the over nine years old motorcycles.  相似文献   

18.
The triplet-triplet absorption spectra of various aromatic compounds in benzene solution were studied by pulse radiolysis. It has been found that methylation of naphthalene characteristic absorption band in this group of compounds at 430±10 nm (naphthalene, 2-methylnaphthalene, 2,6-dimethylaphthalene, anthracene, phenanthrene, pyrene and fluorene); new bands appeared with phenanthrene and pyrene at 495 and 525 nm respectively. The decay remains of the first order in the whole group with similar rate constant values. Diphenyl and 1,1-dinaphthyl show significant changes in their T-T spectra in comparison with the preceding group of compounds. T-T spectrum of o-terphenyl differs significanly from those of p-and m-isomers, which can be caused by greater overlapping of electron orbitals in o-isomer molecule. Aromatic ketones show a complex picture both in spectra and decay kinetics.  相似文献   

19.
A polarization fluoroimmunoassay for cotinine, a major metabolite of nicotine, has been adapted for fully automated screening of urine samples on the Abbott TDx analyser. The method has sensitivity and specificity suitable for the discrimination of active smokers from non-smokers (including passive smokers) by application of a cut-off at 0.5 mg l-1 of total urinary cotinine. Most active smokers' urine gave results over 1 mg l-1, whereas apparent levels in non-smokers were 0.08 mg l-1 or lower. A result for one sample can be obtained in about 5 min and a throughput of 80 samples h-1 can be maintained for large-scale screening applications.  相似文献   

20.
A gas chromatographic-tandem mass spectrometric (GC-MS/MS) method for the simultaneous determination of the three well-known endocrine disruptors, bisphenol A, daidzein and genistein, as well as of four human pesticide metabolites which are supposed to have proper endocrine activity or which are metabolites of endocrine-disrupting compounds, viz., 1- and 2-naphthol, 2-isopropoxyphenol and 3,5,6-trichloropyridinol, has been developed and validated. The method involves enzymatic cleavage of the conjugates using β-glucuronidase/arylsulfatase followed by solid-phase extraction and derivatisation with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide. Isotopically labelled internal standards were used for all analytes, to achieve best analytical error correction. The method proved to be both sensitive and reliable in human urine with detection limits ranging from 0.1 to 0.6 μg/L for all analytes. Precision and repeatability was determined to range from 1 to 15 %. Compared with other published analytical procedures, the present method enables the simultaneous determination of a couple of phenolic agents with competitive or improved analytical reliability. Thus, the present method is suitable for a combined monitoring of the exposure to prominent xenobiotics with effects on the human endocrine system (bisphenol A, carbaryl, chlorpyrifos, chlorpyrifos-methyl, naphthalene, propoxur, triclopyr) and phytoestrogens (daidzein, genistein) in population studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号