首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
冯利  张胜军  朱国华  李沐霏  刘劲松 《色谱》2017,35(4):466-471
基于搅拌棒吸附萃取(SBSE)技术建立了气相色谱-质谱测定地表水中16种多环芳烃(PAHs)的分析方法。该法采用多搅拌吸附棒同时富集,依次热脱附冷聚焦后进样的方式有效解决了搅拌棒吸附时间长、富集水样体积小等问题。优化后的结果表明,在0.2~10 ng/L范围内(萘为0.5~10 ng/L范围),16种PAHs的线性关系良好,相关系数(r)均0.99,方法检出限(MDL)为0.03~0.20 ng/L(萘为0.50 ng/L)。用该方法对钱塘江流域地表水进行测定,共检测出11种PAHs,含量为0.13~1.57 ng/L,不同添加水平下的加标回收率为75.6%~108.9%。该法可应用于地表水样品中该类物质的超痕量检测。  相似文献   

2.
A simple procedure based on stir bar sorptive extraction (SBSE) and high-performance liquid chromatography-fluorescence detection (HPLC-FLD) is presented for the determination of 15 polycyclic aromatic hydrocarbons (PAHs) in herbal tea prepared with Mate leaves (Ilex paraguariensis St. Hil.). The influence of methanol and salt addition to the samples, the extraction time, the desorption time and the number of desorption steps, as well as the matrix effect, were investigated. Once the SBSE method was optimised (10 mL of Mate tea, 2h extraction at room temperature followed by 15 min desorption in 160 microL of an acetonitrile (ACN)-water mixture), analytical parameters such as repeatability (< or = 10.1%), linearity (r2 > or = 0.996), limit of detection (LOD, 0.1-8.9 ng L(-1) ), limit of quantitation (LOQ, 0.3-29.7 ng L(-1) and absolute recovery (24.2-87.0%) were determined. For calibration purposes, a reference sample was firstly obtained by removing the analytes originally present in the lowest contaminated Mate tea studied (via SBSE procedure) and then spiked at 1-1200 ng L(-1)range. The proposed methodology proved to be very convenient and effective, and was successfully applied to the analysis of 11 Mate tea samples commercialised in Brazil. The results of the commercial Mate tea samples found by the SBSE approach were compared with those obtained by liquid-liquid extraction (LLE), showing good agreement.  相似文献   

3.
A method suitable for the determination of unmetabolized polycyclic aromatic hydrocarbons (PAHs) excreted at trace levels (ng/L) in human urine for the monitoring of exposure of the general population to PAH contamination was developed. PAHs were determined, after enrichment by solid-phase extraction on polyurethane foam (PUF) chips, by HPLC with fluorescence detection. Different parameters affecting analyte extraction to the PUF, including urine salting-out and organic additives, and optimization of conditions for clean-up and desorption have been investigated. Optimized conditions were 40 mL acidified urine sample, added with magnesium sulfate, tetrahydrofuran and a 2 cm3 PUF chip, and extracted by shaking at 30 rpm for 1 h at ambient temperature. Desorption was performed, after a clean-up step with diluted sodium hydroxide, using a small amount of diethyl ether. The recovery of PAH congeners from spiked urines was >90% in the 2-100 ng/L range; the detection limit was 0.1-0.5 ng/L, depending on the considered PAH congener; day-to-day precision, at 50 ng/L native PAH content, was CV = 10-20%. The proposed technique provides a simple, economical and effective procedure for the determination of trace amounts of unmetabolized PAHs excreted in human urine spot samples.  相似文献   

4.
Stir bar sorptive extraction (SBSE) and thermal desorption followed by capillary gas chromatography coupled to mass spectrometry (SBSE-TD-GC-MS) was applied to the simultaneous determination of ultra-traces of 16 polycyclic aromatic hydrocarbons (PAHs), 12 polychlorinated biphenyls (PCBs), 6 phthalate esters (PEs) and 3 nonylphenols (NPs) in water samples. The parameters that could affect the sorption-desorption efficiency were studied. A Plackett-Burman design was used for the screening of the main effects of the experimental parameters related to the desorption step (desorption time, desorption temperature, desorption flow, cryo-focusing temperature and vent pressure). Afterwards, two central composite designs were used to find the optimal process settings for the extraction and desorption steps. The best analytical compromise conditions for the simultaneous determination of analytes from spiked water samples were found to be: sample volume (20 mL), sodium chloride addition (30%), methanol addition (20%), desorption time (10 min), desorption temperature (300 degrees C), desorption flow (23 mL min(-1)), cryo-focusing temperature (-50 degrees C) and vent pressure (7 psi). Remarkable recovery, repeatability and reproducibility were attained. Furthermore, excellent linearities (r(2) = 0.959-0.999) and low detection limits (0.1-10 ng L(-1)) were also achieved for the congeners studied. The proposed methodology was applied for the simultaneous determination of PAHs, PCBs, PEs and NPs in sea and estuarine waters. The influence of humic acids on the recovery was also studied.  相似文献   

5.
固相萃取搅拌棒萃取-气相色谱分析海水中的多环芳烃   总被引:21,自引:1,他引:21  
利用固相萃取搅拌棒(SBSE)萃取海水中的多环芳烃,然后用热解吸脱附-气相色谱分析。研究了萃取时间、添加NaCl浓度对萃取效率的影响。实验结果表明,SBSE方法对16种多环芳烃的萃取回收率分别在33.5%~122.4%之间;对标准样品的检出限为2.74-13.5ng/L;方法RSD为3.8%~13.1%。用此方法测定了大连海岸海水中的多环芳烃含量。  相似文献   

6.
A method for mercury analysis and speciation in drinking water was developed, which involved stir bar sorptive extraction (SBSE) with in situ propyl derivatization and thermal desorption (TD)-GC-MS. Ten millilitre of tap water or bottled water was used. After a stir bar, pH adjustment agent and derivatization reagent were added, SBSE was performed. Then, the stir bar was subjected to TD-GC-MS. The detection limits were 0.01 ng mL(-1) (ethylmercury; EtHg), 0.02 ng mL(-1) (methylmercury; MeHg), and 0.2 ng mL(-1) (Hg(II) and diethylmercury (DiEtHg)). The method showed good linearity and correlation coefficients. The average recoveries of mercury species (n=5) in water samples spiked with 0.5, 2.0, and 6.0 ng mL(-1) mercury species were 93.1-131.1% (RSD<11.5%), 90.1-106.4% (RSD<7.8%), and 94.2-109.6% (RSD<8.8%), respectively. The method enables the precise determination of standards and can be applied to the determination of mercury species in water samples.  相似文献   

7.

The commonly used solid-phase extraction (SPE) was compared with the recently developed stir bar sorptive extraction (SBSE) to determine EPA-PAHs from precipitation water samples. SPE was performed using C18 PAH-filled cartridges; magnetic stirring rods 10 mm long and coated with 0.5 mm (24 µL) polydimethylsiloxane were used for SBSE. Determination was performed by high performance liquid chromatography and fluorescence detection. The investigations were performed at a concentration level of 30 ng/L, adjusted to actual PAH concentration levels of precipitation water. The recoveries ranged between 54% (SBSE) and 20% (SPE) respectively and about 100%, while the standard deviation ( n = 5) varied in the range of 4.7-13.5% (SBSE) and 3.6-16.9% (SPE) except for the more volatile compounds acenaphthene and fluorene. The detection limits calculated were between 0.4 and 5.0 ng/L. Both techniques were applied to study the PAH contents of precipitation water of several polluted sites in the city of Halle (Saxony-Anhalt, Germany). The advantages and disadvantages of the methods used are discussed.  相似文献   

8.
A method for the analysis of trace polycyclic aromatic hydrocarbons(PAHs) in aqueous samples has been established by polydimethylsiloxane(PDMS) rod aided stir bar sorptive extraction(SBSE). The homemade PDMS rod has a size of 30 mm?3 mm o.d. with a volume of ca. 200 ?L, stable in thermal desorption process. The enriched PAHs by the PDMS rod were released in a homemade thermal desorption system coupled with gas chromatography. Experimental parameters for extraction of six PAHs were optimized including extraction time, pH, ionic strength and temperature of solution. The procedure has good recoveries of 80.0%―100.3% and very low limits of detection of 4.0―33 ng/L. PAHs in rain and river water were analyzed by this method.  相似文献   

9.
Solid-phase microextraction coupled to GC-MS was optimised for the determination of polycyclic aromatic hydrocarbons (PAHs), phthalate esters and polychlorinated biphenyls (PCBs) in water samples. A 30-microm polydimethylsiloxane fiber was immersed in a 30-ml water sample that contained the analytes of interest (PAHs, PCBs and phthalate esters) and the variables studied were extraction time (15-60 min), extraction temperature (30-90 degrees C), desorption time (1-5 min), desorption temperature (220-270 degrees C) and the addition of sodium chloride (0-9 g). The MultiSimplex programme based on the simplex algorithm was used to establish the optimal conditions. MultiSimplex allowed the simultaneous study of the variables mentioned above and considered the answers of all types of compounds studied in this work. Thus, the optimal conditions obtained allowed the simultaneous determination of PAHs, phthalate esters and PCBs. Furthermore, the accuracy and repeatability of the developed method were calculated from water samples spiked at known concentrations of the analytes. Finally, the optimised method was used to analyse water samples from different sampling points of the Urdaibai and Nerbioi-Ibaizabal estuaries (Biscay, Spain).  相似文献   

10.
Xie SM  Zhang M  Wang ZY  Yuan LM 《The Analyst》2011,136(19):3988-3996
Solid-phase extraction (SPE) is one of the most important techniques for sample preparation, purification, concentration and cleanup. Membranes made from synthetic organic polymers, cellulose, or glass fibers are used for sample pretreatment. In this work, we report that a porous metal membrane, the metal filter in HPLC, was used as a novel kind of solid-phase extraction adsorbent material. To evaluate the performance of the porous metal membrane for the SPE, naphthalene, fluorene, anthracene, phenanthrene, fluoranthene, pyrene, chrysene, perylene and benzo(a)pyrene were selected as analytes. Several parameters that affected the extraction efficiency such as the extraction time, the concentration of NaCl, the extraction temperature and the agitation speed were optimized. The experimental result indicates that the porous metal membrane possesses high adsorption ability to the tested polycyclic aromatic hydrocarbons (PAHs). Under the optimum conditions, the detection limits of the developed method were in the range of 0.03-0.082 μg L(-1) (S/N = 5), and excellent linear correlations between peak area and concentration of PAHs were found over the range of 0.1-60 μg L(-1). The precisions (RSD) for five replicate extractions of the PAHs from sample solutions were in the range of 2.6-5.0%. The recoveries of the PAHs from tap water and river water samples spiked with 9 PAHs (20 μg L(-1) of each individual PAH) ranged from 83.0% to 112.5%. The porous metal membrane is durable, simple, inexpensive, reproducible and has a high adsorption ability for use in SPE of PAHs.  相似文献   

11.
A method for determining 68 pesticides in river water using stir bar sorptive extraction (SBSE)-thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described. SBSE sampling was optimized for sample solution pH, salting-out and methanol addition. Although salting-out enhanced the ability of the method to extract most of the pesticides with low absolute recoveries, the absolute recoveries of four pesticides were not improved by salting-out. The detection limits of the method for the pesticides ranged from 0.2 to 20 ng/l. Analyte recoveries from a river water sample spiked with standards at 10 and 100 ng/l were 58.5–132.0% (RSD: 1.8–15.8%) and 61.0–121.3% (RSD: 1.4–20.2%), respectively.  相似文献   

12.
A robust procedure for the determination of 16 US EPA PAHs in both aqueous (e.g. wastewaters, industrial discharges, treated effluents) and solid samples (e.g. suspended solids and sludge) from a wastewater treatment plant (WWTP) is presented. Recovery experiments using different percentages of organic modifier, sorbents and eluting solvent mixtures were carried out in Milli-Q water (1000 mL) spiked with a mixture of the PAH analytes (100 ng/L of each analyte). The solid phase extraction (SPE) procedures applied to spiked waste water samples (1000 mL; 100 ng/L spiking level) permitted simultaneous recovery of all the 16PAHs with yields >70% (6-13% RSD). SPE clean up procedures applied to sewage and stabilized sludge extracts, showed percent recoveries in the range 73-92% (7-13% RSD) and 71-89% (7-12% RSD), respectively. The methods were used for the determination of PAHs in aqueous and solid samples from the WWTP of Fusina (Venice, Italy). Mean concentrations, as the sum of the 16PAHs in aqueous and suspended solid samples, were found to be approx. in the 1.12-4.62 microg/L range. Sewage and stabilized sludge samples contained mean PAH concentrations, as sum of 16 compounds, in the concentration range of 1.44-1.26 mg/kg, respectively. Extraction and clean up procedures for sludge samples were validated using EPA certified reference material IRM-104 (CRM No. 912). Instrumental analyses were performed by coupling HPLC with UV-diode array detection (UV-DAD) and fluorescence detection (FLD).  相似文献   

13.
This study describes the development of a new method for determining p-hydroxybenzoic esters (parabens) in house dust. This optimised method was based on the pressurised hot water extraction (PHWE) of house dust, followed by the acetylation of the extracted parabens, stir bar sorptive extraction (SBSE) with a polydimethylsiloxane stir bar, and finally analysis using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The combination of SBSE and PHWE allows the analytes to be preconcentrated and extracted from the aqueous extract in a single step with minimal manipulation of the sample. Furthermore the in situ acetylation of parabens prior to SBSE improved their extraction efficiency and their GC-MS signal. The method showed recoveries of between 40 and 80%, good linearity, repeatability and reproducibility (<10% RSD, at 100 ng g(-1), n=5), low limits of detection (from 1.0 ng g(-1) for propyl paraben to 2.1 ng g(-1) for methyl paraben) and quantification (from 3.3 ng g(-1) for propyl paraben to 8.5 ng g(-1) for methyl paraben). The proposed method was applied to the analysis of house dust samples. All the target parabens were found in the samples. Methyl and propyl parabens were the most abundant, with concentrations up to 2440 ng g(-1) and 910 ng g(-1), respectively. The high levels of parabens found in the samples confirm the importance of determining organic contaminants in indoor environments.  相似文献   

14.
A method for the determination of ultra-trace amounts of organochlorine pesticides (OCPs) in river water was developed by using stir bar sorptive extraction (SBSE) followed by thermal desorption and comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (SBSE-TD-GC×GC-HRTOF-MS). SBSE conditions such as extraction time profiles, phase ratio (β: sample volume/polydimethylsiloxane (PDMS) volume), and modifier addition, were examined. Fifty milli-liter sample including 10% acetone was extracted for 3 h using stir bars with a length of 20 mm and coated with a 0.5 mm layer of PDMS (PDMS volume, 47 μL). The stir bar was thermally desorbed and subsequently analyzed by GC×GC-HRTOF-MS. The method showed good linearity over the concentration range from 50 to 1000 pg L(-1) or 2000 pg L(-1) for all analytes, and the correlation coefficients (r(2)) were greater than 0.9903 (except for β-HCH, r(2)=0.9870). The limit of detection (LOD) ranged from 10 to 44 pg L(-1). The method was successfully applied to the determination of 16 OCPs at pg L(-1) to ng L(-1) in river water. The results agree fairly well with the values obtained by a conventional liquid-liquid extraction (LLE)-GC-HRMS (selected ion monitoring: SIM) method using large sample volume (20 L). The method also allows screening of non-target compounds, e.g. pesticides and their degradation products, polyaromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and pharmaceuticals and personal care products (PPCPs) and metabolites in the same river water sample, by using full spectrum acquisition with accurate mass in GC×GC.  相似文献   

15.
利用自制的以聚(乙烯基咪唑-二乙烯基苯)(VIDB)整体材料为涂层的固相萃取搅拌棒(VIDB-SBSE)萃取3种硝基呋喃类药物,然后与高效液相色谱-二极管阵列检测器联用建立了测定饲料和水样品中硝基呋喃类药物残留的方法。详细考察了萃取过程中萃取和解吸时间、样品基质的pH值以及离子强度等实验条件对萃取效率的影响。在最佳条件下,呋喃唑酮的线性范围为0.5~200μg/L,呋喃妥因和呋喃西林的线性范围为0.25~200μg/L,3种目标物的检出限(LO D)(S/N=3)在0.068~0.11μg/L之间,所建方法具有理想的日内和日间重现性(R SD值均小于6%)。在对饲料和实际水样的测定中,不同加标浓度呋喃唑酮、呋喃妥因和呋喃西林的回收率在80.6%~108%之间。研究表明,所建立的方法具有简便、灵敏、环境友好等特点。  相似文献   

16.
陈娜  张毅军  赵万里  陈军  张裕平 《色谱》2018,36(1):5-11
采用氯化胆碱-乙二醇低共熔溶剂(DES)作致孔剂,制备了聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)[poly(BMA-EDMA)]固相微萃取头,并与超高效液相色谱法(UPLC)结合测定了湖水中的3种多环芳烃(PAHs)。实验与不使用DES致孔剂的固相微萃取头和商品化聚二甲硅氧烷(PDMS)萃取头进行比较,含DES的poly(BMA-EDMA)固相微萃取头的富集效果最好。系统考察了萃取条件(萃取时间、萃取溶剂、解吸时间、解吸溶剂及离子强度)对水样中多环芳烃萃取效率的影响。在最优的实验条件下,3种多环芳烃类化合物(萘、联苯、菲)的线性范围为0.1~6.0 mg/L(r≥0.990 3),检出限为2.1~4.9μg/L,回收率为86.4%~111.3%,相对标准偏差(RSD,n=6)为11.2%~15.1%。该法操作简便,稳定性好,成本低,适用于实际环境水样中多环芳烃类化合物的测定。  相似文献   

17.
建立了磁性聚亚苯基共轭微孔聚合物富集/表面增强拉曼光谱法测定水样和土壤中4种多环芳烃的分析方法。待测物经磁性聚亚苯基共轭微孔聚合物吸附萃取,甲醇洗脱后进行SERS检测。结果表明,蒽、芘、荧蒽和苯[α]芘在0.1~10μg/L范围内与其SERS特征峰峰强呈良好的线性关系,检出限为0.03μg/L,回收率为71.6%~115.8%,相对标准偏差不大于13.7%。该分析方法灵敏度高,能够满足实际水样和土壤中4种多环芳烃同时检测的要求。  相似文献   

18.
A simple and sensitive method for the determination of polar aromatic amines (PAAs) was developed using stir bar sorptive extraction (SBSE) coupling to high-performance liquid chromatography. A hydrophilic poly(vinylimidazole-divinylbenzene) (VIDB) monolithic material was prepared and acted as SBSE coating. The influences of polymerization conditions for VIDB on the extraction efficiency were investigated using aniline and 2,4-dinitroaniline as detected solutes. To achieve optimum extraction performance for PAAs, several parameters including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. The results showed that under the optimized experimental conditions, the method showed good sensitivity and excellent recoveries, as well as advantages such as linearity, simplicity, low cost and high feasibility. The extraction performance of present method to the target compounds also compared with commercial SBSE which using polydimethylsiloxane as coating and other SBSE which based on monolithic materials. Finally, the proposed method was successfully applied to the determination of PAAs in lake and sea waters, and excellent recoveries of spiked target compounds in real samples were obtained.  相似文献   

19.
A method for the determination of seven alkylphenols and bisphenol A by stir bar sorptive extraction (SBSE) with in situ derivatization-thermal desorption (TD)-gas chromatography (GC)-mass spectrometry (MS) is described. SBSE was performed with in situ acetylation and without derivatization for comparison. For 4-tert-butylphenol and bisphenol A, in situ acetylation improved the responses in SBSE-TD-GC-MS. The method detection limits ranged from 0.1 to 3.2 ng/l. The recoveries of the analytes from a river water sample spiked with standards at 10 and 100 ng/l were 85.3-105.9% (R.S.D., 3.0-11.0%) and 88.3-105.8% (R.S.D., 1.6-8.3%), respectively.  相似文献   

20.
林福华  黄晓佳  袁东星  刘宝敏 《色谱》2010,28(5):507-512
以双酚A(BPA)为单体,利用整体材料“原位”聚合技术制备以分子印迹聚合物为涂层的吸附萃取搅拌棒(MIP-SBSE),然后与高效液相色谱(HPLC)-二极管阵列检测器联用,探讨其对环境水样BPA的选择萃取性能。优化萃取过程中吸附和解吸时间、解吸液种类以及基底pH值和离子强度对目标化合物的选择吸附性能。在最佳条件下,MIP-SBSE可对模板分子进行有效的选择吸附,线性范围为1.0~200 μg/L,检出限(S/N=3)和定量限(S/N=10)分别为0.28μg/L和0.94 μg/L。在实际水样分析中,具有良好的加标回收率,其值为96.0%~108.7%。研究结果表明,所建立的方法具有简便、灵敏和环境友好等特点。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号